Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Acoustic positioning and orientation prediction

A method is described for use with an acoustic positioner, which enables a determination of the equilibrium position and orientation which an object assumes in a zero gravity environment, as well as restoring forces and torques of an object in an acoustic standing wave field. An acoustic standing wave field is established in the chamber, and the object is held at several different positions near the expected equilibrium position. While the object is held at each position, the center resonant frequency of the chamber is determined, by noting which frequency results in the greatest pressure of the acoustic field. The object position which results in the lowest center resonant frequency is the equilibrium position. The orientation of a nonspherical object is similarly determined, by holding the object in a plurality of different orientations at its equilibrium position, and noting the center resonant frequency for each orientation. The orientation which results in the lowest center resonant frequency is the equilibrium orientation. Where the acoustic frequency is constant, but the chamber length is variable, the equilibrium position or orientation is that which results in the greatest chamber length at the center resonant frequency.

Barmatz, Martin B.↗

Weak positive cloud-to-ground flashes in Northeastern Colorado

The frequency distributions of the peak magnetic field associated with the first detected return stroke of positive and negative cloud-to-ground (CG) flashes were studied using lightning data from northeastern Colorado. These data were obtained during 1985 with a medium-to-high gain network of three direction finders (DF's). The median signal strength of positive flashes was almost two times that of the negatives for flashes within 300 km of the DF's, which have an inherent detection-threshold bias that tends to discriminate against weak signals. This bias increases with range, and affects the detection of positive and negative flashes in different ways, because of the differing character of their distributions. Positive flashes appear to have a large percentage of signals clustered around very weak values that are lost to the medium-to-high gain Colorado Detection System very quickly with increasing range. The resulting median for positive signals could thus appear to be much larger than the median for negative signals, which are more clustered around intermediate values. When only flashes very close to the DF's are considered, however, the two distributions have almost identical medians. The large percentage of weak positive signals detected close to the DF's has not been explored previously. They have been suggested to come from intracloud discharges and thus are improperly classified as CG flashes. Evidence in hand, points to their being real positive, albeit weak CG flashes. Whether or not they are real positive ground flashes, it is important to be aware of their presence in data from magnetic DF networks.

Lopez, Raul E.↗

A radio/optical reference frame. 5: Additional source positions in the mid-latitude southern hemisphere

We report new accurate radio position measurements for 30 sources, preliminary positions for two sources, improved radio postions for nine additional sources which had limited previous observations, and optical positions and optical-radio differences for six of the radio sources. The Very Long Baseline Interferometry (VLBI) observations are part of the continuing effort to establish a global radio reference frame of about 400 compact, flat spectrum sources, which are evenly distributed across the sky. The observations were made using Mark III data format in four separate sessions in 1988-89 with radio telescopes at Tidbinbilla, Australia, Kauai, USA, and Kashima, Japan. We observed a total of 54 sources, including ten calibrators and three which were undetected. The 32 new source positions bring the total number in the radio reference frame catalog to 319 (172 northern and 147 southern) and fill in the zone -25 deg greater than delta greater than -45 deg which, prior to this list, had the lowest source density. The VLBI positions have an average formal precision of less than 1 mas, although unknown radio structure effects of about 1-2 mas may be present. The six new optical postion measurements are part of the program to obtain positions of the optical counterparts of the radio reference frame source and to map accurately the optical on to the radio reference frames. The optical measurements were obtained from United States Naval Observatory (USNO) Black Birch astrograph plates and source plates from the AAT, and Kitt Peak National Observatory (KPNO) 4 m, and the European Southern Observatory (ESO) Schmidt. The optical positions have an average precision of 0.07 sec, mostly due to the zero point error when adjusted to the FK5 optical frame using the IRS catalog. To date we have measured optical positions for 46 sources.

Russell, J. L.↗

Body position does not affect the hemodynamic response to venous air embolism in dogs

Current therapy for massive venous air embolism (VAE) includes the use of the left lateral recumbent (LLR) position. This recommendation is based on animal studies, conducted 50 years ago, which looked primarily at survival. Little is known, however, about the concomitant hemodynamic response after VAE in various body positions. The purpose of this study was to investigate the hemodynamic and cardiovascular changes in various body positions after VAE. Twenty-two mechanically ventilated supine mongrel dogs received a venous air infusion of 2.5 mL/kg at a rate of 5 mL/s. One minute after the infusion, 100% oxygen ventilation was commenced and the body position of the dogs was changed to either the LLR (n = 6), the LLR with the head 10 deg down (LLR-10 deg; n = 6) or the right lateral recumbent (RLR; n = 5) position. Five dogs were maintained in the supine position (SUP; n = 5). One dog died in every group except in the SUP group, where all the dogs recovered. There were no significant differences among the various body positions in terms of heart rate, mean arterial pressure, pulmonary artery pressure, central venous pressure, left ventricular end-diastolic pressure, or cardiac output. The acute hemodynamic changes occurring during the first 5-15 min after VAE recovered to 80% of control within 60 min. Our data suggest that body repositioning does not influence the cardiovascular response to VAE. Specifically, our data do not support the recommendation of repositioning into the LLR position for the treatment of VAE.

Mehlhorn, Uwe↗

Integration of the Shuttle RMS/CBM Positioning Virtual Environment Simulation

Constructing the International Space Station, or other structures, in space presents a number of problems. In particular, payload restrictions for the Space Shuttle and other launch mechanisms prohibit assembly of large space-based structures on Earth. Instead, a number of smaller modules must be boosted into orbit separately and then assembled to form the final structure. The assembly process is difficult, as docking interfaces such as Common Berthing Mechanisms (CBMS) must be precisely positioned relative to each other to be within the "capture envelope" (approximately +/- 1 inch and +/- 0.3 degrees from the nominal position) and attach properly. In the case of the Space Station, the docking mechanisms are to be positioned robotically by an astronaut using the 55-foot-long Remote Manipulator System (RMS) robot arm. Unfortunately, direct visual or video observation of the placement process is difficult or impossible in many scenarios. One method that has been tested for aligning the CBMs uses a boresighted camera mounted on one CBM to view a standard target on the opposing CBM. While this method might be sufficient to achieve proper positioning with considerable effort, it does not provide a high level of confidence that the mechanisms have been placed within capture range of each other. It also does nothing to address the risk of inadvertent contact between the CBMS, which could result in RMS control software errors. In general, constraining the operator to a single viewpoint with few, if any, depth cues makes the task much more difficult than it would be if the target could be viewed in three-dimensional space from various viewpoints. The actual work area could be viewed by an astronaut during EVA; however, it would be extremely impractical to have an astronaut control the RMS while spacewalking. On the other hand, a view of the RMS and CBMs to be positioned in a virtual environment aboard the Space Shuttle orbiter or Space Station could provide similar benefits more safely and conveniently with little additional cost. In order to render and view the RMS and CBMs in a virtual world, the position and orientation of the end effector in three-dimensional space must be known with a high degree of accuracy. A precision video alignment sensor has been developed which can determine the position and orientation of the controlled element relative to the target CBM within approximately one-sixteenth inch and 0.07 angular degrees. Such a sensor could replace or augment the boresighted camera mentioned above. The computer system used to render the virtual world and the position tracking systems which might be used to monitor the user's movements (in order to adjust the viewpoint in virtual space) are small enough to carry to orbit. Thus, such a system would be feasible for use in constructing structures in space.

Dumas, Joseph D.↗

Body position does not affect the hemodynamic response to venous air embolism in dogs

Current therapy for massive venous air embolism (VAE) includes the use of the left lateral recumbent (LLR) position. This recommendation is based on animal studies, conducted 50 yr ago, which looked primarily at survival. Little is known, however, about the concomitant hemodynamic response after VAE in various body positions. The purpose of this study was to investigate the hemodynamic and cardiovascular changes in various body positions after VAE. Twenty-two mechanically ventilated supine mongrel dogs received a venous air infusion of 2.5 mL/kg at a rate of 5 mL/s. One minute after the infusion, 100% oxygen ventilation was commenced and the body position of the dogs was changed to either the LLR (n = 6), the LLR with the head 10 degrees down (LLR-10 degrees; n = 6) or the right lateral recumbent (RLR; n = 5) position. Five dogs were maintained in the supine position (SUP; n = 5). One dog died in every group except in the SUP group, where all the dogs recovered. There were no significant differences among the various body positions in terms of heart rate, mean arterial pressure, pulmonary artery pressure, central venous pressure, left ventricular end-diastolic pressure, or cardiac output. The acute hemodynamic changes occurring during the first 5-15 min after VAE recovered to 80% of control within 60 min. Our data suggest that body repositioning does not influence the cardiovascular response to VAE. Specifically, our data do not support the recommendation of repositioning into the LLR position for the treatment of VAE.

Non-NASA Center↗

Inductive Linear-Position Sensor/Limit-Sensor Units

A new sensor provides an absolute position measurement. A schematic view of a motorized linear-translation stage that contains, at each end, an electronic unit that functions as both (1) a non-contact sensor that measures the absolute position of the stage and (2) a non-contact equivalent of a limit switch that is tripped when the stage reaches the nominal limit position. The need for such an absolute linear position-sensor/limit-sensor unit arises in the case of a linear-translation stage that is part of a larger system in which the actual stopping position of the stage (relative to the nominal limit position) must be known. Because inertia inevitably causes the stage to run somewhat past the nominal limit position, tripping of a standard limit switch or other limit sensor does not provide the required indication of the actual stopping position. This innovative sensor unit operates on an electromagnetic-induction principle similar to that of linear variable differential transformers (LVDTs)

Alhom, Dean↗

Gondola for High Altitude Planetary Science (GHAPS) Telescope Secondary Mirror Positioning Hexapod Issues and Alternatives

Active positioning of the GHAPS secondary telescope mirror is desired to correct for rigid body deflections due to temperature variations and gravity sag in the telescope structure that may impact optical performance. The current design concept for the secondary mirror mount uses a Commercial-Off -the-Shelf hexapod for mirror positioning and fine adjustment. The Hexapod specification states that motions as small as 0.1 microns along the optical axis and 2 microns perpendicular to the optical axis will cause optical aberrations that will require correction by repositioning the secondary mirror. In addition, the secondary mirror mount and positioning system must survive a 15g shock of parachute opening and landing during the instrument recovery operation. The secondary mirror positioning system must operate at a minimum specified temperature of -50 C. The telescope operates in the IR and the secondary mirror mount and positioning device is in the metering path between the primary and secondary mirrors. I2R losses in positioning system actuator devices, which may cause heating of the positioning system and secondary mirror, must be minimized due to the previously mentioned alignment sensitivity and the viewing spectrum of interest. The GHAPs project was cancelled on June 30, 2017. The purpose of this study is to address some of the issues identified with the hexapod secondary mirror positioning system and identify alternative approaches. This information may be used if the project is re-started at a later date.

Gondola Mirror Hexapo↗

A Trilateration Scheme for Relative Positioning

We introduce a trilateration scheme that evaluates the 3-dimensional (3-D) relative position between a reference spacecraft and a target spacecraft using raw-range measurements from a distance baseline of known locations, which we call “anchors”. The anchors can be antennas of a ground-based network (e.g., Deep Space Network (DSN) or Near Earth Network (NEN) stations), or satellites of a spacebased network (e.g., global positioning system (GPS) or tracking and data relay satellite (TDRS)). We define raw-range as the range that includes all the systematic errors that occur during range measurements. A unique feature of this approach is that accurate relative position is derived from a “differencing function” of raw-range measurements of the reference spacecraft and target spacecraft, thereby eliminating most of the systematic errors, such as media effects, ephemeris errors, instrument delays, clock bias, etc. There can be an arbitrary number of target spacecraft, and relative positioning of target spacecraft with respect to the reference spacecraft can be done simultaneously. In this paper, we first assume an idealized system in which clocks on the reference and target spacecraft are synchronized, with clocks of the anchors synchronized as well. We develop a novel iterative algorithm that computes the relative position of the target spacecraft with respect to the reference spacecraft. We illustrate the relative positioning method using the scenario of a network of three ground stations (i.e., the anchors) at Goldstone, California, USA, Madrid, Spain, and Marlargue, Argentina tracking two spacecraft at geosynchronous orbit distance. We demonstrate that the algorithm converges to submeter accuracy in estimating the relative position, in the presence of random errors and systematic errors in raw-range measurements, and in the presence of angular errors in estimating the pointing vectors between the anchors and the reference spacecraft. Next, we relax the requirement of perfect time synchronization between spacecraft, and show that by using an additional anchor, one can estimate and remove the clock biases between the reference and target spacecraft. We add a ground station at Kourou to the above example of three ground stations of Goldstone, Madrid, and Marlargue, and demonstrate that the updated algorithm also converges to meter-level accuracy (submeter in some cases) in the presence of clock biases in addition to the random errors, systematic errors, and angular errors as shown in the above case. We compare this scheme with a similar trilateration scheme for relative positioning scheme first proposed by Montenbruck in 2002.

Cheung, Kar-Ming↗

Improvements to GNSS Positioning in Challenging Environments by 3DMA Lidar Informed Selective Satellites Usage

The use of global navigation satellite systems (GNSS) for position estimation tends to yield poor results when operating inside of an urban canyon due to large obstructions (e.g., buildings) that disrupt signals as they travel from a satellite to a receiver resulting in a position estimate that may significantly fluctuate in magnitude and direction. Identifying and removing signals that are non-line-of-sight (NLOS) to the receiver and only using signals that are line-of-sight (LOS) can improve the estimated position. However, quickly and accurately determining the LOS status of each measurement can be challenging without additional information about the operating environment. Use of publicly available lidar data can be used to incorporate techniques, such as 3D-mapping-aided (3DMA), to estimate the LOS status of satellites and augment the position solution accordingly. To complicate the issue, the error on the GNSS position estimate in an urban canyon is often so large that is it not sufficient to use as an approximate location for LOS prediction. That is, at times the calculated GNSS solution is not representative of the true location and cannot be used to accurately predict which satellites are within LOS due to the difference in the physical geometry associated with the two locations. This paper explores the use of a GNSS/inertial fused position solution as the initial position estimate for predicting which satellites are within LOS in an urban environment and the impact that removal of predicted NLOS satellites has on the GNSS position solution.

GPS↗

Impact of Stress-Activated Positive Holes on the Redox Timing in Organisms Living at the Surface of Rocks: Unlocking Nature's Secrets

Squeezing and deforming igneous and/or high-grade metamorphic rocks activates electronic charge carriers known as positive holes, h•, that are defect electrons in the O2– sublattice. Similar to h• in semiconductors the h• in rocks affect electrical and thermal properties. They produce electrochemical reactions, localized electrical signals, and currents. In this study, we explore the effects of positive holes on the electron flow in the electron transport chain (ETC) of organisms living at the surface of rocks such as gabbro or granite. We found that positive holes, h•, disrupt the temporal coordination in vivo governed by oscillating reduction-oxidation reactions, known as the redox cycle. Positive holes affect the timing of the redox cycle by interacting with molecules in vivo, leading to the formation of superoxide anions and hydroxyl radicals. Thus, we observed that positive holes significantly impede the growth of yeast Saccharomyces cerevisiae (i.e., colony size) and delay the sprouting of broccoli and chia seeds. Additionally, positive holes were found to exert discernible impacts on plant development such as stem length and leaf size. Our findings highlight the intricate interplay between positive holes, redox timing, and biological processes, shedding light on the potentially significant role of positive holes in influencing the growth and development of organisms in tectonically stressed rock environments. Understanding these effects has implications for a broader understanding of redox biology and of how environmental factors can influence cellular development in natural settings.

Redox Timing in Organisms↗

A Wire Position Monitor System for the 1.3 FHZ Tesla-Style Cryomodule at the Fermilab New-Muon-Lab Accelerator

The first cryomodule for the beam test facility at the Fermilab New-Muon-Lab building is currently under RF commissioning. Among other diagnostics systems, the transverse position of the helium gas return pipe with the connected 1.3 GHz SRF accelerating cavities is measured along the {approx}15 m long module using a stretched-wire position monitoring system. An overview of the wire position monitor system technology is given, along with preliminary results taken at the initial module cooldown, and during further testing. As the measurement system offers a high resolution, we also discuss options for use as a vibration detector. An electron beam test facility, based on superconducting RF (SRF) TESLA-style cryomodules is currently under construction at the Fermilab New-Muon-Lab (NML) building. The first, so-called type III+, cryomodule (CM-1), equipped with eight 1.3 GHz nine-cell accelerating cavities was recently cooled down to 2 K, and is currently under RF conditioning. The transverse alignment of the cavity string within the cryomodule is crucial for minimizing transverse kick and beam break-up effects, generated by the high-order dipole modes of misaligned accelerating structures. An optimum alignment can only be guaranteed during the assembly of the cavity string, i.e. at room temperatures. The final position of the cavities after cooldown is uncontrollable, and therefore unknown. A wire position monitoring system (WPM) can help to understand the transverse motion of the cavities during cooldown, their final location and the long term position stability after cryo-temperatures are settled, as well as the position reproducibility for several cold-warm cycles. It also may serve as vibration sensor, as the wire acts as a high-Q resonant detector for mechanical vibrations in the low-audio frequency range. The WPM system consists out of a stretched-wire position detection system, provided with help of INFN-Milano and DESY Hamburg, and RF generation and read-out electronics, developed at Fermilab.

43 PARTICLE ACCELERATORS↗

Self-calibrating solar position sensor

A sun positioning sensor and method of accurately tracking the sun are disclosed. The sensor includes a position sensing diode and a disk having a body defining an aperture for accepting solar light. An extension tube having a body that defines a duct spaces the position sensing diode from the disk such that the solar light enters the aperture in the disk, travels through the duct in the extension tube and strikes the position sensing diode. The extension tube has a known length that is fixed. Voltage signals indicative of the location and intensity of the sun are generated by the position sensing diode. If it is determined that the intensity values are unreliable, then historical position values are used from a table. If the intensity values are deemed reliable, then actual position values are used from the position sensing diode.

14 SOLAR ENERGY↗

Beam Position and Phase Monitor - Wire Mapping System

The Los Alamos Neutron Science Center (LANSCE) deploys many cylindrical beam position and phase monitors (BPPM) throughout the linac to measure the beam central position, phase and bunched-beam current. Each monitor is calibrated and qualified prior to installation to insure it meets LANSCE requirements. The BPPM wire mapping system is used to map the BPPM electrode offset, sensitivity and higher order coefficients. This system uses a three-axis motion table to position the wire antenna structure within the cavity, simulating the beam excitation of a BPPM at a fundamental frequency of 201.25 MHz. RF signal strength is measured and recorded for the four electrodes as the antenna position is updated. An effort is underway to extend the systems service to the LANSCE facility by replacing obsolete electronic hardware and taking advantage of software enhancements. This paper describes the upgraded wire positioning system's new hardware and software capabilities including its revised antenna structure, motion control interface, RF measurement equipment and Labview software upgrades. The main purpose of the wire mapping system at LANSCE is to characterize the amplitude response versus beam central position of BPPMs before they are installed in the beam line. The wire mapping system is able to simulate a beam using a thin wire and measure the signal response as the wire position is varied within the BPPM aperture.

43 PARTICLE ACCELERATORS↗

Position Verification for the Prostate: Effect on Rectal Wall Dose

Purpose: To evaluate the effect of gold marker (GM)-based position correction on the cumulative dose in the anorectal wall compared with traditional bony anatomy (BA)-based correction, taking into account changes in anorectal shape and position. Methods and Materials: A total of 20 consecutive prostate cancer patients, treated with curative external beam radiotherapy, were included. Four fiducial GMs were implanted in the prostate. Positioning was verified according to the shift in BA and GMs on daily electronic portal images. Position corrections were determined using on- and off-line position verification protocols according to the position of the GMs (GM-on and GM-off) and BA (BA-off). For all patients, intensity-modulated radiotherapy plans were made for the GM (8-mm planning target volume margin) and BA (10-mm planning target volume margin) protocols. The dose distribution was recomputed on 11 repeat computed tomography scans to estimate the accumulated dose to the prostate and anorectal wall while considering internal organ motion. Results: The dose that is at least received by 99% of the prostate was, on average, acceptable for all protocols. The individual patient data showed the best coverage for both GM protocols, with >95% of the prescribed dose for all patients. The anorectal wall dose was significantly lower for the GM protocols. The dose that is at least received by 30% of the rectal wall was, on average, 54.6 Gy for GM-on, 54.1 Gy for GM-off, and 58.9 Gy for BA-off (p <.001). Conclusion: Position verification with GM and reduced planning target volume margins yielded adequate treatment of the prostate and a lower rectal wall dose, even when accounting for independent movement of the prostate and anorectal wall.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bolus-dependent dosimetric effect of positioning errors for tangential scalp radiotherapy with helical tomotherapy

The dosimetric effect of errors in patient position is studied on-phantom as a function of simulated bolus thickness to assess the need for bolus utilization in scalp radiotherapy with tomotherapy. A treatment plan is generated on a cylindrical phantom, mimicking a radiotherapy technique for the scalp utilizing primarily tangential beamlets. A planning target volume with embedded scalplike clinical target volumes (CTVs) is planned to a uniform dose of 200 cGy. Translational errors in phantom position are introduced in 1-mm increments and dose is recomputed from the original sinogram. For each error the maximum dose, minimum dose, clinical target dose homogeneity index (HI), and dose-volume histogram (DVH) are presented for simulated bolus thicknesses from 0 to 10 mm. Baseline HI values for all bolus thicknesses were in the 5.5 to 7.0 range, increasing to a maximum of 18.0 to 30.5 for the largest positioning errors when 0 to 2 mm of bolus is used. Utilizing 5 mm of bolus resulted in a maximum HI value of 9.5 for the largest positioning errors. Using 0 to 2 mm of bolus resulted in minimum and maximum dose values of 85% to 94% and 118% to 125% of the prescription dose, respectively. When using 5 mm of bolus these values were 98.5% and 109.5%. DVHs showed minimal changes in CTV dose coverage when using 5 mm of bolus, even for the largest positioning errors. CTV dose homogeneity becomes increasingly sensitive to errors in patient position as bolus thickness decreases when treating the scalp with primarily tangential beamlets. Performing a radial expansion of the scalp CTV into 5 mm of bolus material minimizes dosimetric sensitivity to errors in patient position as large as 5 mm and is therefore recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flexible positioning of a large area detector using an industrial robot

The DIAD beamline for Dual Imaging and Diffraction at Diamond Light Source has opted to use an industrial robot to position its Dectris Pilatus 2M CdTe diffraction detector. This setup was chosen to enable flexible positioning of the detector in a quarter-sphere around the sample position whilst reliably holding the large weight of 139 kg of detector, detector mount and cabling in a stable position. Metrology measurements showed that the detector can be positioned with a linear repeatability of <19.7 µm and a rotational repeatability of <16.3 µrad. The detector position stays stable for a 12 h period with <10.1 µm of movement for linear displacement and <3.8 µrad for rotational displacement. X-ray diffraction from calibration samples confirmed that the robot is sufficiently stable to resolve lattice d-spacings within the instrumental broadening given by detector position and beam divergence.

36 MATERIALS SCIENCE↗

An accuracy assessment of different rigid body image registration methods and robotic couch positional corrections using a novel phantom

Purpose: Image guided radiotherapy (IGRT) using cone beam computed tomography (CBCT) images greatly reduces interfractional patient positional uncertainties. An understanding of uncertainties in the IGRT process itself is essential to ensure appropriate use of this technology. The purpose of this study was to develop a phantom capable of assessing the accuracy of IGRT hardware and software including a 6 degrees of freedom patient positioning system and to investigate the accuracy of the Elekta XVI system in combination with the HexaPOD robotic treatment couch top. Methods: The constructed phantom enabled verification of the three automatic rigid body registrations (gray value, bone, seed) available in the Elekta XVI software and includes an adjustable mount that introduces known rotational offsets to the phantom from its reference position. Repeated positioning of the phantom was undertaken to assess phantom rotational accuracy. Using this phantom the accuracy of the XVI registration algorithms was assessed considering CBCT hardware factors and image resolution together with the residual error in the overall image guidance process when positional corrections were performed through the HexaPOD couch system. Results: The phantom positioning was found to be within 0.04 ({sigma}= 0.12) Degree-Sign , 0.02 ({sigma}= 0.13) Degree-Sign , and -0.03 ({sigma}= 0.06) Degree-Sign in X, Y, and Z directions, respectively, enabling assessment of IGRT with a 6 degrees of freedom patient positioning system. The gray value registration algorithm showed the least error in calculated offsets with maximum mean difference of -0.2({sigma}= 0.4) mm in translational and -0.1({sigma}= 0.1) Degree-Sign in rotational directions for all image resolutions. Bone and seed registration were found to be sensitive to CBCT image resolution. Seed registration was found to be most sensitive demonstrating a maximum mean error of -0.3({sigma}= 0.9) mm and -1.4({sigma}= 1.7) Degree-Sign in translational and rotational directions over low resolution images, and this is reduced to -0.1({sigma}= 0.2) mm and -0.1({sigma}= 0.79) Degree-Sign using high resolution images. Conclusions: The phantom, capable of rotating independently about three orthogonal axes was successfully used to assess the accuracy of an IGRT system considering 6 degrees of freedom. The overall residual error in the image guidance process of XVI in combination with the HexaPOD couch was demonstrated to be less than 0.3 mm and 0.3 Degree-Sign in translational and rotational directions when using the gray value registration with high resolution CBCT images. However, the residual error, especially in rotational directions, may increase when the seed registration is used with low resolution images.

60 APPLIED LIFE SCIENCES↗