Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “polymer electrolyte membrane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Improved Anode for a Direct Methanol Fuel Cell

A modified chemical composition has been devised to improve the performance of the anode of a direct methanol fuel cell. The main feature of the modified composition is the incorporation of hydrous ruthenium oxide into the anode structure. This modification can reduce the internal electrical resistance of the cell and increase the degree of utilization of the anode catalyst. As a result, a higher anode current density can be sustained with a smaller amount of anode catalyst. These improvements can translate into a smaller fuel-cell system and higher efficiency of conversion. Some background information is helpful for understanding the benefit afforded by the addition of hydrous ruthenium oxide. The anode of a direct methanol fuel cell sustains the electro-oxidation of methanol to carbon dioxide in the reaction CH3OH + H2O--->CO2 + 6H(+) + 6e(-). An electrocatalyst is needed to enable this reaction to occur. The catalyst that offers the highest activity is an alloy of approximately equal numbers of atoms of the noble metals platinum and ruthenium. The anode is made of a composite material that includes high-surface-area Pt/Ru alloy particles and a proton-conducting ionomeric material. This composite is usually deposited onto a polymer-electrolyte (proton-conducting) membrane and onto an anode gas-diffusion/current-collector sheet that is subsequently bonded to the proton-conducting membrane by hot pressing. Heretofore, the areal density of noble-metal catalyst typically needed for high performance has been about 8 mg/cm2. However, not all of the catalyst has been utilized in the catalyzed electro-oxidation reaction. Increasing the degree of utilization of the catalyst would make it possible to improve the performance of the cell for a given catalyst loading and/or reduce the catalyst loading (thereby reducing the cost of the cell). The use of carbon and possibly other electronic conductors in the catalyst layer has been proposed for increasing the utilization of the catalyst by increasing electrical connectivity between catalyst particles. However, the relatively low density of carbon results in thick catalyst layers that impede the mass transport of methanol to the catalytic sites. Also, the electrical conductivity of carbon is less than 1/300th of typical metals. Furthermore, the polymer-electrolyte membrane material is acidic and most metals are not chemically stable in contact with it. Finally, a material that conducts electrons (but not protons) does not contribute to the needed transport of protons produced in the electro-oxidation reaction.

Valdez, Thomas↗

Membrane Pretreatment and Cell Conditioning for Proton Exchange Membrane Water Electrolysis

As the research community studying proton exchange membrane water electrolysis (PEMWE) grows, it is important to develop methods that achieve transparent, reproducible research. Reproducibility of performance and durability is a challenge facing the PEMWE field, as the published literature includes a wide spread of results obtained with nominally similar materials. Prior round-robin performance benchmarking efforts [1] have identified inadequate cell conditioning as a major source of variation in apparent cell performance. Inadequate pre-treatment and conditioning can lead to instability in initial performance and adds ambiguity to durability measurements. However, excessively prolonged conditioning procedures limit the throughput of testing and the pace of research. Pretreatment and conditioning methods vary significantly across the research literature, but little systematic investigation is available into the mechanisms of these procedures or how procedural differences may impact results. This presentation will discuss investigations into the effects of membrane pre-treatment and operating procedures during cell conditioning on initial performance and catalyst-specific accelerated stress tests, with the aim of recommending procedures to enable clear, reproducible, and high-throughput research. Methods investigated include the use of hydrogen peroxide, acids, and hydration at elevated temperature for membrane pretreatment, and conditioning procedures such as current or voltage holds and cycling. The investigations cover both the impacts of these procedures on cell performance and stability as well as underlying mechanisms and processes taking place in the cell materials.

cell↗

Effect of hydration on morphology of thin phosphonate block copolymer electrolyte membranes studied by electron tomography

The morphological changes of phosphonate polypeptoid electrolyte membranes, poly-N-(2-ethyl)hexylglycine-block-poly-N-phosphonomethylglycine (pNeh m -b-pNpm n ), in hydrated and dry states were characterized by cryogenic transmission electron microscopy (cryo-TEM) and cryogenic electron tomography (cryo-ET). The analysis of 3D tomograms revealed that the pNeh 9 -b-pNpm 9 thin films absorbed a large amount of water, resulting in the formation of membranes that were nearly flat and giant multicompartment vesicles dispersed in the water phase. A simple lamellar phase appeared when the films were dried. In contrast, pNeh 18 -b-pNpm 18 thin films absorbed little water and formed small highly curved unilamellar and multilamellar vesicles. Water was located mainly outside the closely-packed vesicles. When water was removed by drying, the walls of adjacent vesicles collapsed to form honeycomb-like capsules. Here, the changes in domain size reflected changes in chain conformations. The pNpm9 blocks were saturated by water and fully extended, while pNpm 18 blocks were neither saturated by water nor fully extended. In addition, the thicknesses of hydrophobic blocks in the hydrated films of both pNeh 9 -b-pNpm 9 and pNeh 18 -b-pNpm 18 were smaller than those in the dry films, reflecting an increase of the average distance between the neighboring junctions of polypeptoid molecules.

36 MATERIALS SCIENCE↗

Highly Durable and Active Pt/Sb-Doped SnO 2 Oxygen Reduction Reaction Electrocatalysts Produced by Atomic Layer Deposition

Platinum supported on mixed-metal oxides (MMOs) are a class of active and durable cathode catalysts for proton exchange membrane fuel cell (PEMFC) due to a combination of the high oxidative stability of the supports and strong-metal-support interactions (SMSI) that enable them to exceed the activity of Pt/C. Herein, we solve a significant remaining challenge with Pt/MMO systems, namely the relatively low surface area and porosity. This is achieved by dispersing nearly-uniform Pt clusters using atomic layer deposition (ALD) on highly conductive (6.2 S/cm) and stable antimony doped tin dioxide (ATO) support. ALD-Pt/ATO exhibited significantly higher electrochemically active surface area (ECSA) (74 m 2 /g) and oxygen reduction reaction (ORR) catalytic activity (102 mA/mg Pt at 0.9 V vs. RHE) compared to Pt/ATO synthesized using ethylene glycol (ECSA=31 m 2 /g Pt , mass activity=52 mA/mg Pt at 0.9 V vs. RHE) and formic acid reduction methods (ECSA=28 m 2 /g Pt , mass activity=46 mA/mg Pt at 0.9 V vs. RHE). Further characterization showed that wet chemical methods resulted in poorer Pt particle dispersion, poor control over Pt particle size distribution and chemical degradation of the support (during Pt deposition). Given the near-ideal Pt particle size distribution of the ALD-Pt/ATO, particle size growth and loss of ECSA was found to be minimal over the course of rigorous potential cycling. Thus, after 10,000 potential cycles between 1V and 1.5V vs. RHE, ALD-Pt/ATO and other Pt/ATOs were found to retain 100% of their initial ECSA compared to 57.6% retention for Pt/C. Upon testing in a H 2 /air PEMFC, following 1,000 potential cycles, the change in ALD-Pt/ATO performance was negligible while Pt/C exhibited a 68.2% loss of initial peak power density. Thus, ALD-Pt/ATO is an active and highly durable ORR electrocatalyst in PEMFCs under start-up-shut down conditions.

25 ENERGY STORAGE↗

Understanding water management in platinum group metal-free electrodes using neutron imaging

Platinum group metal-free (PGM-free) catalysts are a low-cost alternative to expensive PGM catalysts for polymer electrolyte fuel cells. However, due to the low volumetric activity of PGM-free catalysts, the catalyst layer thickness of the PGM-free catalyst electrode is an order of magnitude higher than PGM based electrodes. The thick PGM-free electrodes suffer from increased transport resistance and poor water management, which ultimately limits the fuel cell performance. This manuscript presents the study of water management in the PGM-free electrodes to understand the transport limitations and improve fuel cell performance. Here, in-operando neutron imaging is performed to estimate the water content in different components across the fuel cell thickness. Water saturation in thick PGM electrodes, with similar catalyst layer thickness to PGM-free electrodes, is lower than in the PGM-free electrodes irrespective of the operating conditions, due to high water retention by PGM-free catalysts. Improvements in fuel cell performance are accomplished by enhancing water removal from the flooded PGM-free electrode in three ways: (i) enhanced water removal with a novel microporous layer with hydrophilic pathways incorporated through hydrophilic additives, (ii) water removal through anode via novel GDL in the anode, and (iii) lower water saturation in PGM-free electrode structures with increased catalyst porosity.

25 ENERGY STORAGE↗

Mass transport limitations in polymer electrolyte water electrolyzers using spatially-resolved current measurement

Here this work utilizes spatially-resolved current measurements to provide insight into mass transport limitations in electrolyzers that are not observable from traditional polarization measurement. In this study, two types of flow-fields (parallel and triple-serpentine) and two types of diffusion media (patterned porous thin titanium foil LGDLs and Ir-coated titanium felt PTLs) were examined. A non-uniform current distribution dominated by mass transport limitations was observed to be instigated by the restriction of liquid water transport to catalyst sites. Additionally, conditions are revealed which yield similar polarization performance but dissimilar current distributions. In such cases, the transport limitations for different architectures and porous media affect polarization in different regions of the active area. Furthermore, the triple-serpentine flow-field used in this study performs better than the parallel flow-field under mass transport limited operating conditions. This indicates that the parallel flow-field used in this study is more susceptible to starvation than the triple-serpentine flow-field for the electrolyzer studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Production of Renewable Natural Gas from Waste Carbon Dioxide Sources (CRADA Final Report)

This CRADA provides new funding from SoCalGas and DOE's BETO and FCTO Offices focused hydrogen mass transfer limitations in H2@Scale processes. The project leverages the existing hydrogen production capabilities at the Energy Systems Integration Facility (ESIF) and SoCalGas' 700 L bioreactor system designed, built, and delivered to NLR under the first phase of this CRADA. This Joint Work Statement will cover new hardware modifications between NLR's electorlyzer stack and the SoCalGas bioreactor located outdoors. The new hardware and controls will provide researchers with the tools needed to obtain preliminary experimental data for a non-provisional application due in July 2019. The IP being developed is expected to improve the productivity of the bioreactor and would have wider impacts on other end-use processes using pressurized hydrogen (H2). In addition, this new funding enhances an existing BETO Biopower award by developing a 10-15 kW electrolyzer that is scalable to the MW-class with reduced capital cost and higher efficiency aimed at improving H2 mass transfer to downstream processes, like biomethanation. Finally due to the close-coupling between the electrolyzer stack and bioreactor, R&D will focus on cell retention, nutrient maintenance, optimal water management and process controls.

08 HYDROGEN↗

Advanced fuel cell concepts for future NASA missions

Studies of primary fuel cells for advanced all electric shuttle type vehicles show an all fuel cell power system with peak power capability of 100's of kW to be potentially lighter and have lower life cycle costs than a hybrid system using advanced H2O2 APU's for peak power and fuel cells for low power on orbit. Fuel cell specific weights of 1 to 3 lb/kW, a factor of 10 improvement over the orbiter power plant, are projected for the early 1990's. For satellite applications, a study to identify high performance regenerative hydrogen oxygen fuel cell concepts for geosynchronous orbit was completed. Emphasis was placed on concepts with the potential for high energy density (Wh/lb) and passive means for water and heat management to maximize system reliability. Both alkaline electrolyte and polymer membrane fuel cells were considered.

Stedman, J. K.↗

Understanding and Manipulating Counterion Condensation within Charged Polymer Electrolytes for Selective and Low Resistant Membrane Separations

Polymeric ion-exchange membranes are found at the heart of numerous electrochemical systems spanning separations (electrodialysis and membrane capacitive deionization) and energy conversion and storage (flow batteries, fuel cells, and electrolyzers). The ion-exchange membrane separators need to be ion conducting but electron insulating, and in many scenarios selective for a particular ion to conduct. Because of their polymeric nature, the molecular architectures of ion-exchange membranes lack the molecular precision found in many inorganic materials. Plus, they contain numerous structural defects that impede ionic transport. As a result of their poor structure, it has been difficult to carefully probe the underlying physics that governs ion transport in ion-exchange membranes. We investigated counterion condensation phenomena in ion-exchange membranes and correlated it to bulk ionic charge transport and selectivity in precisely defined and long-range ordered materials afforded through the principles of directed self-assembly. A multi-faceted approach spanning i.) advanced metrology, two-dimensional atomic force microscopy, x-ray scattering, and ion-exchange equilibria, and ii.) molecular simulations (classical molecular dynamics and ab-inito molecular dynamics) that bridge multiple time and length scales, were employed to correlate the extent of counterion condensation to ionic conductivity and selectivity. After uncovering the extent of the condensation phenomena in this project, new macromolecular chemistries were employed to manipulate the ion pairing interactions of the condensed counterions to tethered ions on the polymer backbone so more facile and selective conduction rates can be attained. The research has aided in the rational design of polymeric ion-exchange membrane separators with high current density for electrochemical systems and subsequently better energy efficiency.

36 MATERIALS SCIENCE↗

Regenerative fuel cell study for satellites in GEO orbit

The results of a 12 month study to identify high performance regenerative hydrogen-oxygen fuel cell concepts for geosynchronous satellite application are summarized. Emphasis was placed on concepts with the potential for high energy density and passive means for water and heat management to maximize system reliability. Both polymer membrane and alkaline electrolyte fuel cells were considered, with emphasis on the alkaline cell because of its high performance, advanced state of development, and proven ability to operate in a launch and space environment. Three alkaline system concepts were studied. Results indicate that using near term technology energy densities between 46 and 52 watt-hour/lb can be achieved at efficiencies of 55 percent. Using advanced light weight cell construction which was achieved in experimental cells, composite tankage material for the reactant gases and the reversible stack concept, system energy densities of 115 watt-hours/lb can be projected.

Vandine, Leslie↗

Regenerative fuel cell study for satellites in GEO orbit

Summarized are the results of a 12-month study to identify high performance regenerative hydrogen-oxygen fuel cell concepts for geosynchronous satellite application. Emphasis was placed on concepts with the potential for high energy density (W-hr/lb) and passive means for water and heat management to maximize system reliability. Both polymer membrane and alkaline electrolyte fuel cells were considered, with emphasis on the alkaline cell because of its high performance, advanced state of development, and proven ability to operate in a launch and space environment. Three alkaline system concepts were studied. The first, the integrated design, utilized a configuration in which the fuel cell and electrolysis cells are alternately stacked inside a pressure vessel. Product water is transferred by diffusion during electrolysis and waste heat is conducted through the pressure wall, thus using completely passive means for transfer and control. The second alkaline system, the dedicated design, uses a separate fuel cell and electrolysis stack so that each unit can be optimized in size and weight based on its orbital operating period. The third design was a dual function stack configuration, in which each cell can operate in both fuel cell and electrolysis mode, thus eliminating the need for two separate stacks and associated equipment. Results indicate that using near term technology energy densities between 46 and 52 W-hr/lb can be achieved at efficiencies of 55 percent. System densities of 115 W-hr/lb are contemplated.

Levy, Alexander↗

Regenerative fuel cell study for satellites in GEO orbit

The results of a 12 month study to identify high performance regenerative hydrogen-oxygen fuel cell concepts for geosynchronous satellite application are summarized. Emphasis was placed on concepts with the potential for high energy density and passive means for water and heat management to maximize system reliability. Both polymer membrane and alkaline electrolyte fuel cells were considered, with emphasis on the alkaline cell because of its high performance, advanced state of development, and proven ability to operate in a launch and space environment. Three alkaline system concepts were studied. Results indicate that using near term technology energy densities between 46 and 52 watt-hour/lb can be achieved at efficiencies of 55 percent. Using advanced light weight cell construction which was achieved in experimental cells, composite tankage material for the reactant gases and the reversible stack concept, system energy densities of 115 watt-hours/lb can be projected.

Van Dine, Leslie↗

Electrocatalytic Reduction of Carbon Dioxide to Methane

A room-temperature electrocatalytic process that effects the overall chemical reaction CO2 + 2H2O yields CH4 + 2O2 has been investigated as a means of removing carbon dioxide from air and restoring oxygen to the air. The process was originally intended for use in a spacecraft life-support system, in which the methane would be vented to outer space. The process may also have potential utility in terrestrial applications in which either or both of the methane and oxygen produced might be utilized or vented to the atmosphere. A typical cell used to implement the process includes a polymer solid-electrolyte membrane, onto which are deposited cathode and anode films. The cathode film is catalytic for electrolytic reduction of CO2 at low overpotential. The anode film is typically made of platinum. When CO2 is circulated past the cathode, water is circulated past the anode, and a suitable potential is applied, the anode half-cell reaction is 4H2O yields 2O2 + 8H(+) + 8e(-). The H(+) ions travel through the membrane to the cathode, where they participate in the half-cell reaction CO2 + 8H(+) + 8e(-) yields CH4 + 2H2O.

Sammells, Anthony F.↗

Elucidating Polymer Binder Entanglement in Freestanding Sulfide Solid-State Electrolyte Membranes

This study advances the development of flexible, sheet-type sulfide solid-state electrolytes (SSEs) for use in all-solid-state batteries, emphasizing the important and previously insufficiently investigated role of polymer binder entanglement. Here, the molecular weight of polymer binders is pivotal in crafting robust, freestanding SSE films. Our research uncovers a dual impact: higher molecular weight binders bolster the structural integrity of SSE films but elevate grain boundary resistance and diminish critical current density, whereas lower molecular weight poly(isobutylene) films, despite their more uniform distribution, lack the essential strain hardening or strength for sustained active material contact. Crucially, full cells employing higher molecular weight binders demonstrate improved discharge capacity retention, contrasting sharply with the notable capacity degradation in lower molecular weight cells. Our findings not only deepen the comprehension of binder influences in solid-state batteries but also chart a course for refining all-solid-state battery technologies, a key stride for the future of energy storage solutions.

25 ENERGY STORAGE↗

Studies on Methanol Crossover in Liquid-Feed Direct Methanol Pem Fuel Cells

The performance of liquid feed direct methanol fuel cells using various types of Nafion membranes as the solid polymer electrolyte have been studied. The rate of fuel crossover and electrical performance has been measured for cells with Nafion membranes of various thicknesses and equivalent weights. The crossover rate is found to decrease with increasing thickness and applied current. The dependence of crossover rate on current density can be understood in terms of a simple linear diffusion model which suggests that the crossover rate can be influenced by the electrode structure in addition to the membrane. The studies suggest that Nafion EW 1500 is a very promising alternate to Nafion EW 1100 for direct methanol fuel cells.

Methanol Pem Fuel↗