Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “polycarbonates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

212 records · Page 12

Calibration and Validation of the SHERLOC Instrument Operating in Jezero Crater, Mars

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemistry (SHERLOC) is an instrument onboard the Mars 2020 Perseverance rover. It consists of a spectrometer that measures deep ultraviolet (DUV) resonance Raman and native fluorescence photons generated through surface interactions with a 248.6 nm pulsed laser. Two microscopic imagers, the Autofocus Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering (WATSON), provide high-resolution context images of SHERLOC targets. The ACI is co-boresighted with the spectrometer. To ensure proper calibration, the SHERLOC calibration target (SCT) is mounted on the front of the rover and consists of ten different materials. The SCT was designed, fabricated, assembled, and tested by Jacobs Technology, Inc., and NASA Johnson Space Center. The dimensions of the calibration target housing are 150 x 89 x 33 mm and it weighs ~437 g. The ten targets are arranged in two rows; the first six are hard targets (AlGaN for Raman and fluorescence, diffuse transmission target, a slice of the SaU008 Mars meteorite, an intensity maze, and polycarbonate over geocache coin) and the remaining four are soft-goods targets (Vectran, Ortho-Fabric, Teflon, and nGimat-coated Teflon). The hard targets calibrate the spectrometer’s Raman and fluorescence spectral accuracy, ambient light reflection, and Raman response curve, while the soft-goods targets are spacesuit materials that function as human exploration targets, some of which are also used for spectral calibration. SHERLOC also has an internal calibration target consisting of AlGaN on sapphire (275 nm) located inside the ACI opaque dust cover to ensure proper instrument functioning between calibration target analyses. Initial SHERLOC, ACI, and WATSON calibration and validation on Mars was performed using the internal calibration target on sols 59, 83, 98, and 141; WATSON imaging of the SCT on sols 26 and 62, and SHERLOC spectroscopy and ACI imaging of the SCT on sol 59. These early data provide initial insights into instrument performance and the stability and degradation of the calibration target materials relative to the Martian surface and dust environment. Early observations also have implications for future astronaut spacesuit materials.

Trevor G Graff↗

Remodeling BioSentinel’s Microbial Metabolism Measurement System

BioSentinel, the first biological CubeSat beyond low Earth orbit, will investigate how Saccharomyces cerevisiae responds to ionizing radiation using optical measurements of a colorimetric metabolic indicator dye (alamarBlue). To map optical data to more detailed metabolic measurements, a microbial culture system for ground testing was designed consisting of a 400 mL beaker and a rubber stopper with pass-through holes for its five sensor probes (electrical conductivity, pH, oxidation-reduction potential, dissolved oxygen, optical density). The initial design had several drawbacks. It was only partially reusable due to its one-time sealants: Teflon tape and parafilm. A steady increase in oxygen levels within the sensor’s testingdata indicated the design was not sufficiently airtight. Degradation of the rubber stopper’s elasticity due to sterilization and reinsertion of the probes led to poor robustness and eventual replacement. The vessel’s large headspace didn’t reproduce flight conditions and a large culture volume required more reagents. The system has been redesigned to contain a rigid, biocompatible polycarbonate disc lid that allows for threaded inserts. The culture vessel’s height will be reduced from 110 mm to 65 mm to decrease overhead space and material costs. A more reliable seal will be achieved with a gasket and clamps. The optical probe records absorbance at four wavelengths to characterize cell density and alamarBlue dye ratios. A pneumatically operated plunger draws media through the hollow interior of the probe. Currently, deformation of the silicone on the plunger causes asymmetrical movement and a drift from its initial state. Designs are being developed to limit the plunger’s travel for a more accurate measurement cycle. The remodeled system is under construction and will be tested for leaks and accuracy. The measurements collected will be used to provide additional insight into the optical data returned from the BioSentinel mission.

Astrobiology↗

Exploration Helmet Permanent Anti-fog Study

For the current Extravehicular Mobility Unit (EMU) spacesuit, an astronaut applies an anti-fog solution to the interior of the helmet bubble before each EVA. However, the anti-fog solution has been reported to cause eye discomfort during at least seven EMU EVAs when the anti-fog solution contacted the crew member’s eyes. During STS-100, astronaut Chris Hadfield reported the eye irritation temporarily blinded him during his spacewalk. In addition, the wipe on anti-fog solution is a consumable that needs to be accounted for and a supply launched for missions. To solve this, the Exploration EMU (xEMU) pressure bubble investigated using a permanent anti-fog coating during Design Verification and Test (DVT) human in the loop (HITL) events. Chosen for previous use in Constellation Space Suit develop, HTAF-601, a water based permanent anti-fog solution, was tested. However, major issues have arisen with further HITL testing with the coating. Cleaning the helmet has been a challenge to avoid damaging the permanent anti-fog coating. NASA has completed a set of different methods for cleaning the anti-fog to try to document a preferred method. It was found isopropyl alcohol (IPA) cannot be used to clean the interior of the helmet because it will strip and delaminate the permanent anti-fog coating. Even with using a very gentle cleaning method of flushing with distilled or DI water and dabbing at facial oils, the permanent anti-fog starts to delaminate consistently after 50 hours manned pressurized time (MPT). Finally, the HTAF-601 coating is being discontinued by the vendor. Due to these issues, further investigation is being completed evaluating two solvent based anti-fog solutions: Exxene’s HCF-100 and FSI’s Visgard 106-94. Each coating will be evaluated on polycarbonate samples for application consistency, steam cycles (mimicking breath cycles), cleaning durability, haze, and light transmission. This study will determine if either coating is a viable option to pursue as a permanent anti-fog for spacesuit helmet applications.

spacesuit↗

Evaluation of Long Term Microbial Regrowth in Slosh Water Tanks From the International Space Station

The NASA Launch Services Program (LSP) maintained the SPHERES-Slosh experiment aboard the International Space Station (ISS) between 2013 and 2019. The purpose of the Slosh experiment was to examine how liquids move inside fuel tanks in a microgravity environment. These tanks were similar to water storage tanks planned for use aboard future space systems, where large dormant periods between crew-use will provide similar conditions for biological growth or chemical leaching. The water within the SLOSH tanks remained undisturbed for over five years after testing concluded, providing a unique sample for stored water under microgravity conditions without prior protocols for microbial control such as sterilization or addition of biocides. The Slosh storage tanks were returned to Kennedy Space Center (KSC) aboard SpaceX CRS-18 mission in November 2019. Upon return of the tanks, the water within each tank was analyzed to determine how the water chemistry and biology changed during its tenure in microgravity. The data obtained and described within this publication provided a basis and reasoning for planning water storage and purification treatment methods aboard ISS, Gateway, and future space habitats. Results demonstrated that low microbial concentrations were present within the water, as expected since no biocide treatment was employed, yet no extensive biofilm formation was observed after 5 years even in the presence of microbial food sources such as the polycarbonate structure and food color additives. This experimentation demonstrates that future biofilm studies should be performed on this type of experimental setup with proper controls aboard ISS to examine microbial regrowth to improve microbial control within space water systems.

Luke B. Roberson↗

Exploration Helmet Permanent Anti-Fog Study

For the current Extravehicular Mobility Unit (EMU) spacesuit, an astronaut applies an antifog solution to the interior of the helmet bubble before each EVA. However, the anti-fog solution has been reported to cause eye discomfort during at least seven EMU EVAs when the anti-fog solution contacted the crew member’s eyes. During STS-100, astronaut Chris Hadfield reported the eye irritation temporarily blinded him during his spacewalk. In addition, the wipe on anti-fog solution is a consumable that needs to be accounted for and a supply launched for missions. To solve this, NASA has tested different permanent anti-fog coatings. However, major issues have arisen with Human in the Loop (HITL) testing with the coatings. Cleaning and removing Valsalva devices which use pressure sensitive adhesives have been challenges to avoid damaging the permanent anti-fog coating. Due to these issues, further investigation is being completed evaluating two solvent based anti-fog solutions: Exxene’s HCF-100 and FSI’s Visgard 106-94. Each coating will be evaluated on polycarbonate samples for application consistency, steam cycles (mimicking breath cycles), cleaning durability, haze, and light transmission. This study will determine if either coating is a viable option to pursue as a permanent anti-fog for spacesuit helmet applications.

spacesuit↗

Effect of Roughness on Transition on the BOLT-1a Geometry in Supersonic Flow

Infrared thermography measurements on an 8.8% scale BOLT-1a model were made in the NASA Langley Probe Calibration Tunnel for freestream unit Reynolds numbers from 7.7 × 10^ -6 /m to 30.7 × 10^ -6 /m, a freestream Mach number of 3.5, and nominal angle of attack of 0 degrees. The model was printed from polycarbonate and tested before and after fine-grit sanding to evaluate the effect of surface roughness on transition. Global surface roughness measurements were obtained using a 3D optical profilometer. The temperature distributions on the upper and lower experimental surfaces of the test article were simultaneously captured using two infrared cameras. Prior to testing, the facility’s freestream environment was characterized. At a freestream unit Reynolds number of approximately 17 × 10^ -6 /m, the nozzle-wall boundary layer began to transition non-uniformly, inducing transition on the model. The boundary-layer state was determined by analyzing Stanton number distributions computed from the surface temperature measurements. The present supersonic conditions that were examined on BOLT-1a were found to display both similarities and disparities in comparison to previous hypersonic experiments.

boundary layer transition↗

Space Environmental Effects on Additively Manufactured Materials – Results from MISSE-9 and MISSE-10

The NASA Marshall Space Flight Center (MSFC) Space Environmental Effects (SEE) and Contamination Control (CC) teams prepared and characterized MISSE-9 and MISSE-10’s additively manufactured (AM) materials samples to investigate the effect of ultraviolet (UV) radiation, thermal cycling, outgassing, and temperature and provide data on the durability of these samples. Materials studied were polyetherimide (Ultem 1010 and 9085), electrostatic dissipative polyetherketoneketone (ESD-PEKK), also known commercially as Antero 840CN03, polycarbonate biocompatible per ISO 10993 USP Class VI (PC-ISO), and Inconel 718. Some samples were manufactured at MSFC, while 3D printer manufacturers Stratasys and Made In Space, Inc. (MIS) (now Redwire) participated in this effort to compare different vendors and printing setups. Results from nondestructive analyses and tensile testing are presented.

additive manufacturing↗

Exploration Helmet Permanent Anti-Fog Study

For the current Extravehicular Mobility Unit (EMU) spacesuit, an astronaut applies an antifog solution to the interior of the helmet bubble before each EVA. However, the anti-fog solution has been reported to cause eye discomfort during at least seven EMU EVAs when the anti-fog solution contacted the crew member’s eyes. During STS-100, astronaut Chris Hadfield reported the eye irritation temporarily blinded him during his spacewalk. In addition, the wipe on anti-fog solution is a consumable that needs to be accounted for and a supply launched for missions. To solve this, NASA has tested different permanent anti-fog coatings. However, major issues have arisen with Human in the Loop (HITL) testing with the coatings. Cleaning and removing Valsalva devices which use pressure sensitive adhesives have been challenges to avoid damaging the permanent anti-fog coating. Due to these issues, further investigation is being completed evaluating two solvent based anti-fog solutions: Exxene’s HCF-100 and FSI’s Visgard 106-94. Each coating will be evaluated on polycarbonate samples for application consistency, steam cycles (mimicking breath cycles), cleaning durability, haze, and light transmission. This study will determine if either coating is a viable option to pursue as a permanent anti-fog for spacesuit helmet applications.

spacesuit↗

Hermes LunarG Executive Summary

Hermes LunarG is a flight-proven research platform that can measure the effects of lunar gravity on different types of astromaterials using Blue Origin's reusable sub-orbital flight system. Hermes LunarG is part of the Strata-1 family of experiments that leverages International Space Station (ISS) flight hardware to investigate particle dynamics. The platform is a single payload locker consisting of four clear, polycarbonate tubes containing different regolith simulant materials. Onboard the New Shephard, once lunar gravity conditions are achieved, the payload releases the simulants to move freely in the tubes. The payload will capture images and sensor data to illustrate the dust settling effects and behavior of lunar regolith simulant in this environment. Funded by NASA STMD (Space Technology Mission Directorate) GCD (Game Changing Development) Program, the project has been developed by NASA, T STAR (Texas Space Technology Applications and Research) and Texas A&M's SOAR (Sub-Orbital Astromaterial Research) team to deliver a platform that will further address gaps in dust mitigation and improve the understanding of regolith in lunar gravity.

regolith↗

Beyond BioSentinel: Iterative Development of Automated Microfluidics

NASA Ames has flown a series of Bio-CubeSats that performed biology experiments supported by automated fluidic systems. Since Genesat-1 in 2006, these payloads have increased in complexity and functionality, building upon previous successes, and applying lessons learned. BioSentinel was the most recent of this series, launched into heliocentric orbit onboard Artemis-1 in 2022. This presentation will discuss how the fluidic technology developed for these Bio-CubeSat missions, including the multi-layer polycarbonate manifolds at the heart of the BioSentinel BioSensor, have spurred the development of several additional projects. Most directly is the modified BioSensor that will be a part of LEIA, which will perform its Lunar biology experiment onboard a Commercial Lunar Payload Services lander. Several search-for-life manifolds have been designed to prepare samples from icy moons for downstream analyses. Two early career Polaris projects are developing fluidics to perform genetic sequencing on samples from multigenerational cell culture and to extract and quantify target miRNAs to support astronaut radiation health assessment. Improving the readiness of these systems has been accelerated by adopting the established flight heritage and microgravity-compatibility of the Bio-CubeSat fluidic hardware and designs, while focusing development efforts on the integration of novel functionalities and components.

microfluidics↗

Preliminary Measurements on the BOLT Geometry in the Supersonic Low Disturbance Tunnel

Experiments were performed in the Mach 3.5 Supersonic Low Disturbance Tunnel on the BOundary-Layer Transition (BOLT) geometry. The goal of this campaign was to assess changes to the transition front by varying the freestream noise and the model surface quality. The model was printed of polycarbonate and is 30% scale of the flight geometry. It was tested under noisy and quiet conditions at different streamwise positions in the tunnel and was also tested before and after improvements were made to the model surface through sanding and gap reduction. Pitch and yaw angles were nominally zero. The model surface temperature was measured using infrared thermography and thermocouples as the unit Reynolds number was swept from 4.75 – 15.8 × 10 6 m −1 . Boundary-layer transition was observed near the midspan of the model for unit Reynolds numbers above 10×10 6 m −1 in quiet flow, while transition was already observed on the shoulders below 5×10 6 m −1 in noisy flow. The model surface enhancements improved the symmetry of the transition front for quiet flow but made only slight differences for noisy flow. In quiet flow, the impact of streamwise positioning on transition was more significant on the model shoulders compared to the central region. The difference in the shoulder heating was likely due to variation in noise radiated from the nozzle sidewalls. The total temperature and initial wall temperatures were near 300 K and 293 K, respectively, which generally resulted in negative convective heat-flux values into the model. Hot-wire anemometry was also utilized to characterize the freestream and to conduct a planar survey near the base of the model for the 7.92 × 10 6 m −1 quiet condition. The survey captured the thickening of the boundary layer at the centerline and the vortical nature of the flow outboard of it. Spectral analysis of the mass-flux fluctuations near the midspan demonstrates that the boundary layer is laminar and suggests that the thick boundary layer caused the relatively warm centerline observed in the infrared images.

boundary layer transition↗

Preliminary Measurements on the BOLT Geometry in the Supersonic Low Disturbance Tunnel

Experiments were performed in the Mach 3.5 Supersonic Low Disturbance Tunnel on the BOundary-Layer Transition (BOLT) geometry. The goal of this campaign was to assess changes to the transition front by varying the freestream noise and the model surface quality. The model was printed of polycarbonate and is 30% scale of the flight geometry. It was tested under noisy and quiet conditions at different streamwise positions in the tunnel and was also tested before and after improvements were made to the model surface through sanding and gap reduction. Pitch and yaw angles were nominally zero. The model surface temperature was measured using infrared thermography and thermocouples as the unit Reynolds number was swept from 4.75 -- 15.8 x 10^6 m^{-1}. Boundary-layer transition was observed near the midspan of the model for unit Reynolds numbers above 10 x 10^6 m^{-1} in quiet flow, while transition was already observed on the shoulders below 5 x 10^6 m^{-1} in noisy flow. The model surface enhancements improved the symmetry of the transition front for quiet flow but made only slight differences for noisy flow. In quiet flow, the impact of streamwise positioning on transition was more significant on the model shoulders compared to the central region. The difference in the shoulder heating was likely due to variation in noise radiated from the nozzle sidewalls. The total temperature and initial wall temperatures were near 300 K and 293 K, respectively, which generally resulted in negative convective heat-flux values into the model. Hot-wire anemometry was also utilized to characterize the freestream and to conduct a planar survey near the base of the model for the 7.92 x 10^6 m^{-1} quiet condition. The survey captured the thickening of the boundary layer at the centerline and the vortical nature of the flow outboard of it. Spectral analysis of the mass-flux fluctuations near the midspan demonstrates that the boundary layer is laminar and suggests that the thick boundary layer caused the relatively warm centerline observed in the infrared images.

boundary layer transition↗

3D Printed Materials Characterization for Rapid Prototyping and Plant Growth

Through KSC IRTD funding in 2022, this project brought a list of 18, 3D printed filaments into formal characterization testing to provide a reference for their behaviors under relevant applications. The project format set up a series of tests to expose 3D printed specimens. A total of 1,989 individual 3D printed test specimens were sent across KSC to be scrutinized by three laboratories to fulfill a multidisciplinary assessment of each material TRL. Testing started with 18 materials. Initially, seed germination assays in the PPA, sample materials were enclosed in petri dishes with lettuce seeds on damp germination paper. No significant impacts on lettuce seed germination were observed in this testing. Next, sample coupons were printed and sent for materials testing to the KSC Analysis/Mechanical and Environmental Testing Laboratory, where they were subjected to 14- and 30-day soak periods in solutions used to provide nutrients to plants or to sanitize hardware before and after use. Following a long soak typical of a 30-day plant growout in Hoagland’s solution, 14 materials gained more than 10% of their own mass. This indicated an increased potential for leaching or providing conditions that are not food safe. Materials that exceeded 15% absorption by mass were eliminated from further testing. Based off this result, the team continued with a core list of nine filaments to fulfill Tensile, Flexural, Biofilm formation, and plant growth testing. Those materials were PLA (Raise3D), ABS (Raise3D), PETG (PolyethyleneTerephthalate Glycol) (Raise3D), ASA (Acrylonitrile Styrene Acrylate) (Raise3D), PC (Polycarbonate) (Raise3D), TPU (Thermoplastic polyurethane)-95 (Raise3D), PLA Copper (Gizmodorks), PP (Polypropylene) (Braskem), and HIPS (High Impact Polystyrene) (Gizmodorks). Testing also quantified the spectral impact of using different color 3D printed surfaces in a growth chamber. The material used for spectral testing was PLA. Printing employed a standard surface texture representative of all materials. It was shown through Tensile Testing (ASTM D638-22) that the breaking force of a 3D printed part greatly varied depending on layer orientation. This is common through all materials, and demonstrates that the strength of a 3D printed component can be maximized by layering the material normal to the primary force on the part. Four-point flexural testing (ASTM D790) provided quantities of interest, Flexural modulus, Flexural strength, Flexural stress, and strain at break within a 5% strain limit from each of nine materials. Biofilm formation testing was conducted in the Molecular and Microbiological Laboratory. Testing completed on specimens from each material showed equal formation on the surface. Additional plant growth testing was conducted in the PPA beyond the initial germination testing. The final assessment documents that three materials (PLA, ABS, and PC) have reached TRL 6 through extensive testing, and ultimate end-to-end applied use in experimental or testing conditions (flight and ground). TRL 5 materials (ASA, TPU-95, PLA Copper, PP, PETG, and HIPS) have all been successfully applied in Research and Development for crop growth applications and are ready to be applied in formal testing. TRL 4 materials Nylon910, PLA Carbon Fiber, PPA CF, PPA Glass Fiber (GF), NinjaFlex, and P-filament 721 are materials that were able to be printed and tested, but have yet to show data meeting applied requirements. TRL 3 NylonX, Flex TPE-185, and Nylon were unable to be reliably printed to fulfill testing. These results provide researchers with reference for materials to use during plant growth experimentation, and also set a standard for future characterization work applying 3D printing and materials to testing, research, and experimentation.

Gioia Massa↗

Durable Anti-Reflective and Anti-Fog Coatings Produced by Aerosol Impact Driven Assembly

The Exploration Extravehicular Mobility Unit’s (xEMU) helmet is a complex assembly designed to accomplish several tasks to protect and enable astronauts. In addition to maintaining a suitable environment for the wearer, it must also allow for appropriate mobility and provide a wide and undistorted view of the surroundings. A critical component of the helmet’s optical system is the anti-fog coating. While previous versions of the anti-fog coating have provided suitable anti-fog performance, they have been difficult to apply, lacked mechanical or chemical durability, or resulted in unanticipated failures (e.g., outgassing of eye-irritating materials during use). This work describes the use of a new coating technology, aerosol impact-driven assembly (AIDA), to develop a next-generation permanent anti-fog coating for the xEMU helmet. AIDA’s unique ability to tune both the refractive index and surface roughness of films was used to deposit a thin, transparent (>85% transmittance of visible light), and hydrophilic (contact angle <10°) anti-fog coating. The coating’s abrasion resistance and chemical resistance was evaluated and it was found that the coating maintained both its anti-fog and anti-reflective functionally. Finally, the scalability of the process was demonstrated by successfully coating the polycarbonate blanks used to form the helmet’s bubble.

Spacesuit↗