From thermal catalysis to plasma catalysis: a review of surface processes and their characterizations

The use of atmospheric pressure plasma to enhance catalytic chemical reactions involves complex surface processes induced by the interactions of plasma-generated fluxes with catalyst surfaces. Industrial implementation of plasma catalysis necessitates optimizing the design and realization of plasma catalytic reactors that enable chemical reactions that are superior to conventional thermal catalysis approaches. This requires the fundamental understanding of essential plasma-surface interaction mechanisms of plasma catalysis from the aspect of experimental investigation and theoretical analysis or computational modeling. In addition, experimental results are essential to validate the relative theoretical models and hypotheses of plasma catalysis that was rarely understood so far, compared to conventional thermal catalysis. This overview focuses on two important application areas, nitrogen fixation and methane reforming, and presents a comparison of important aspects of the state of knowledge of these applications when performed using either plasma-catalysis or conventional thermal catalysis. We discuss the potential advantage of plasma catalysis over thermal catalysis from the aspects of plasma induced synergistic effect and in situ catalyst regeneration. In-situ/operando surface characterization of catalysts in plasma catalytic reactors is a significant challenge since the high pressure of realistic plasma catalysis systems preclude the application of many standard surface characterization techniques that operate in a low-pressure environment. Here, we present a review of the status of experimental approaches to probe gas-surface interaction mechanisms of plasma catalysis, including an appraisal of demonstrated approaches for integrating surface diagnostic tools into plasma catalytic reactors.

54 ENVIRONMENTAL SCIENCES↗

Analysis Methods for Electron Radiography Based on Laser-Plasma Accelerators

Analysis methods are presented for determining the resolution of both contact and projected electron radiography based on a laser-plasma accelerator. A means to determine the field strength of the electric/magnetic fields generated when a laser is incident on an object of interest is also out-lined. Broad radiography results are reported and future plans for the diagnostic technique are outlined.

43 PARTICLE ACCELERATORS↗

Ion temperature and rotation fluctuation measurements with ultra-fast charge exchange recombination spectroscopy (UF-CHERS) in the DIII-D tokamak

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

Truong, D. D. (ORCID:0000000285732539)↗

A novel method to measure ion density in ICF experiments using x-ray spectroscopy of cylindrical tracers

The indirect drive approach to inertial confinement fusion has undergone important advances in the past few years. Improvements in temperature and density diagnostic methods are leading to more accurate measurements of the plasma conditions inside the Hohlraum and therefore to more efficient experimental designs. The implementation of dot spectroscopy has proven to be a versatile approach to extracting space- and time-dependent electron temperatures. In this method, a microdot of a mid-Z material is placed inside the Hohlraum and its K-shell emission spectrum is used to determine the plasma temperature. However, radiation transport of optically thick lines acting within the cylindrical dot geometry influences the outgoing spectral distribution in a manner that depends on the viewing angle. This angular dependence has recently been studied in the high energy density regime at the OMEGA laser facility, which allowed us to design and benchmark appropriate radiative transfer models that can replicate these geometric effects. By combining these models with the measurements from the dot spectroscopy experiments at the National Ignition Facility, we demonstrate here a novel technique that exploits the transport effects to obtain time-resolved measurements of the ion density of the tracer dots, without the need for additional diagnostics. Furthermore, we find excellent agreement between experiment and simulation, opening the possibility of using these geometric effects as a density diagnostic in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave diagnostic for the determination of the electron temperature of a low density shock-heated argon plasma

The diffraction, defocusing and beam bending effects of microwaves transmitted through a bounded shock-heated argon plasma with low electron density are investigated with the purpose of developing an accurate method for electron temperature (Te) determination. This report describes the evaluation technique and presents results for an argon plasma with pressure between 3 and 10 torr, and T2 between 5500 and 9500 K. The electron temperature values obtained have a range of uncertainty between -20% and +10% only. The electron temperature is equal or lower by approximately 1000 K in comparison to the heavy particle temperature (T2).

Schneider, C. P.↗

Validation of the strike point position estimation with the local expansion method for MAST upgrade on the DIII-D tokamak

A local expansion method has been proposed for estimating the strike point position for the advanced divertor configuration on the MAST Upgrade tokamak. The paper discusses the application and assesses the performance of the technique on a long-legged divertor plasma configuration on an operating device - the DIII-D tokamak. A comparison of the spatial location of the outer strike point estimated with the local expansion method against the plasma boundary reconstruction and divertor diagnostics on the DIII-D tokamak is reported. A good agreement with the equilibrium reconstruction and diagnostic data is achieved with respect to estimation of the spatial location of the outer strike point for the long-legged divertor plasma discharge.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Variable frequency VLF signals in the magnetosphere Associated phenomena and plasma diagnostics

Coherent variable-frequency signals (ramps) extending from 1 to 8 kHz, injected into the magnetosphere from Siple Station, Antarctica (L=4.3), exhibit upper and lower cutoffs when received at the conjugate station, Roberval, Quebec. Ramp group delay measurements and ionospheric sounding data are used to determine the cold plasma density and L shell of the propagation path. Relationships among f, df/dt, and the 'phase equator' for gyroresonance are calculated using second-order resonance equations generalized to relativistic electrons. The concept thereby introduced is used to develop a diagnostic technique which, for an assumed g(alpha)(v exp -n) electron distribution, provides an estimate of the energy dependence n. Additional aspects of the magnetospheric response to ramp injection, such as emission triggering, curvature due to dispersion, and amplitude saturation, are discussed.

Carlson, C. R.↗

XRIPL

XRIPL is a library of tools for processing x-ray radiographs and extracting contours of interest within the image using computer vision techniques. Features include spatial calibration, denoising, background and attenuation correction through pseudo-flatfielding, watershed segmentation, contour processing, and visualization. The details of the XRIPL analysis pipeline are published in the Proceedings of the 23rd Topical Conference on High-Temperature Plasma Diagnostics Proceedings (LA-UR-20-30133) [1]. [1] P. M. Kozlowski, Y. Kim, B. M. Haines, H. F. Robey, T. J. Murphy, H. M. Johns, and T. S. Perry. Use of Computer Vision for analysis of image data sets from high temperature plasma experiments. Review of Scientific Instruments 92, 033532 (2021) https://doi.org/10.1063/5.0040285

Kozlowski, Pawel↗

Proton damage in (Y,Lu,Gd) 3 (Al,Ga) 5 O 12 :Ce mixed garnet scintillators

Scintillators are vital components for nuclear instrumentation and its applications, including plasma diagnostics and imaging. As yields in controlled fusion experiments increase, the radiation tolerance of scintillator candidates for use in instrumentation is of particular importance. High radiation exposure can damage scintillating materials and alter the optical properties. The effects of radiation damage in Ce-doped mixed garnet ceramics over the compositional range (Y,Gd,Lu) 3 (Al,Ga) 5 O 12 are investigated using optical techniques. The samples were exposed to 200 keV protons to an accumulated fluence of 10 16 protons per square centimeter, then characterized using diffuse reflectance spectroscopy (DRS). DRS with visible light can assess the radiation tolerance of opaque poly-crystalline samples, which can be easily sintered from powders and thus offer distinct advantages in characterization compared to single crystals. Qualitative trends in induced absorption are presented as a function of composition, and the ideal cerium dopant concentration for Y 2 LuAl 5 O 12 is determined to be 0.60–0.75 mol.%.

47 OTHER INSTRUMENTATION↗

Physics of Solar Prominences: I-Spectral Diagnostics and Non-LTE Modelling

This review paper outlines background information and covers recent advances made via the analysis of spectra and images of prominence plasma and the increased sophistication of non-LTE (i.e. when there is a departure from Local Thermodynamic Equilibrium) radiative transfer models. We first describe the spectral inversion techniques that have been used to infer the plasma parameters important for the general properties of the prominence plasma in both its cool core and the hotter prominence-corona transition region. We also review studies devoted to the observation of bulk motions of the prominence plasma and to the determination of prominence mass. However, a simple inversion of spectroscopic data usually fails when the lines become optically thick at certain wavelengths. Therefore, complex

Labrosse, N.↗

Transition region response of the symmetric double probe and its application in the lower ionosphere

The technique is discussed of the symmetric double-probe which readily lends itself to the in situ measurement of plasma temperature in the ionospheric D-region because it can lead to meaningful results under relatively high collision frequencies where the Langmuir probe has been observed to fail. It is shown that the modification to the original collision-free double-probe theory of Johnson and Malter for the determination of electron temperature is never greater than + or - 12%, with a value of (8 + or - 2)% nominally applicable in the case of D-region diagnostics. This technique was successfully operated on a Nike-Cajun payload flown at mid-day from White Sands, New Mexico to an apogee of 78.5 km. The associated electronics and deployed double-probe configuration are presented, and a current-voltage characteristic collected in the ascent stage at 73.7 km is briefly discussed. The values of electron temperature indicated by the sampled data are approximately 30% higher than those predicted by theory for the anticipated state of thermal equilibrium with the ambient neutrals.

Szuszczewicz, E. P.↗

The FOXSI Solar Sounding Rocket Campaigns

The Focusing Optics X-ray Solar Imager (FOXSI) is, in its initial form, a sounding rocket experiment designed to apply the technique of focusing hard X-ray (HXR) optics to the study of fundamental questions about the high-energy Sun. Solar HXRs arise via bremsstrahlung from energetic electrons and hot plasma produced in solar flares and thus are one of the most direct diagnostics of flare-accelerated electrons and the impulsive heating of the solar corona. Previous missions have always been limited in sensitivity and dynamic range by the use of indirect (Fourier) imaging due to the lack of availability of direct focusing optics, but technological advances now make direct focusing accessible in the HXR regime (as evidenced by the NuSTAR spacecraft and several suborbital missions). The FOXSI rocket experiment develops and optimizes HXR focusing telescopes for the unique scientific requirements of the Sun. To date, FOXSI has completed two successful flights on 2012 November 02 and 2014 December 11 and is funded for a third flight. This paper gives a brief overview of the experiment, which is sensitive to solar HXRs in the 4-20 keV range, describes its first two flights, and gives a preview of plans for FOXSI-3.

Glesener, Lindsay↗

Argon/UF6 plasma experiments: UF6 regeneration and product analysis

An experimental and analytical investigation was conducted to aid in developing some of the technology necessary for designing a self-critical fissioning uranium plasma core reactors (PCR). This technology is applicable to gaseous uranium hexafluoride nuclear-pumped laser systems. The principal equipment used included 1.2 MW RF induction heater, a d.c. plasma torch, a uranium tetrafluoride feeder system, and batch-type fluorine/UF6 regeneration systems. Overall objectives were to continue to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure, gaseous UF6; and to continue development of complementary diagnostic instrumentation and measurement techniques to characterize the effluent exhaust gases and residue deposited on the test chamber and exhaust system components. Specific objectives include: a development of a batch-type UF6 regeneration system employing pure high-temperature fluorine; development of a ruggedized time-of-flight mass spectrometer and associated data acquisition system capable of making on-line concentration measurements of the volatile effluent exhaust gas species in a high RF environment and corrosive environment of UF6 and related halide compounds.

Roman, W. C.↗

Augmenting machine learning of Grad–Shafranov equilibrium reconstruction with Green's functions

This work presents a method for predicting plasma equilibria in tokamak fusion experiments and reactors. The approach involves representing the plasma current as a linear combination of basis functions using principal component analysis of plasma toroidal current densities (J t ) from the EFIT-AI equilibrium database. Then utilizing EFIT's Green's function tables, basis functions are created for the poloidal flux (ψ) and diagnostics generated from the toroidal current (J t ). Similar to the idea of a physics-informed neural network (NN), this physically enforces consistency between ψ, J t , and the synthetic diagnostics. First, the predictive capability of a least squares technique to minimize the error on the synthetic diagnostics is employed. The results show that the method achieves high accuracy in predicting ψ and moderate accuracy in predicting J t with median R 2 = 0.9993 and R 2 = 0.978, respectively. A comprehensive NN using a network architecture search is also employed to predict the coefficients of the basis functions. The NN demonstrates significantly better performance compared to the least squares method with median R 2 = 0.9997 and 0.9916 for J t and ψ, respectively. The robustness of the method is evaluated by handling missing or incorrect data through the least squares filling of missing data, which shows that the NN prediction remains strong even with a reduced number of diagnostics. Additionally, the method is tested on plasmas outside of the training range showing reasonable results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Diagnostics by Antenna Impedance Measurements

The impedance of an electrically short antenna immersed in a plasma provides an excellent in situ diagnostic tool for electron density and other plasma parameters. By electrically short we mean that the wavelength of the free-space electromagnetic wave that would be excited at the driving frequency is much longer than the physical size of the antenna. Probes using this impedance technique have had a long history with sounding rockets and satellites, stretching back to the early 1960s. This active technique could provide information on composition and temperature of plasmas for comet or planetary missions. Advantages of the impedance probe technique are discussed and two classes of instruments built and flown by SDL-USU for determining electron density (the capacitance and plasma frequency probes) are described.

Swenson, C. M.↗