Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

CMOS Active Pixel Sensor Star Tracker with Regional Electronic Shutter

The guidance system in a spacecraft determines spacecraft attitude by matching an observed star field to a star catalog....An APS(active pixel sensor)-based system can reduce mass and power consumption and radiation effects compared to a CCD(charge-coupled device)-based system...This paper reports an APS (active pixel sensor) with locally variable times, achieved through individual pixel reset (IPR).

active pixel sensor CCD↗

Estimating pixel-level uncertainty in ocean color retrievals from MODIS

The spectral distribution of marine remote sensing reflectance, R(rs), is the fundamental measurement of ocean color science, from which a host of bio-optical and biogeochemical properties of the water column can be derived. Estimation of uncertainty in these derived properties is thus dependent on knowledge of the uncertainty in satellite-retrieved R(rs) (u(c)(R(rs))) at each pixel. Uncertainty in R(rs), in turn, is dependent on the propagation of various uncertainty sources through the R(rs) retrieval process, namely the atmospheric correction (AC). A derivative-based method for uncertainty propagation is established here to calculate the pixel-level uncertainty in R(rs), as retrieved using NASA’s multiple-scattering epsilon (MSEPS) AC algorithm and verified using Monte Carlo (MC) analysis. The approach is then applied to measurements from the Moderate Resolution Imaging Spectroradiometer (MODIS) on the Aqua satellite, with uncertainty sources including instrument random noise, instrument systematic uncertainty, and forward model uncertainty. The uc(Rrs) is verified by comparison with statistical analysis of coincident retrievals from MODIS and in situ Rrs measurements, and our approach performs well in most cases. Based on analysis of an example 8-day global products, we also show that relative uncertainty in R(rs) at blue bands has a similar spatial pattern to the derived concentration of the phytoplankton pigment chlorophyll-a (chl-a), and around 7.3%, 17.0%, and 35.2% of all clear water pixels (chl-a ≤ 0.1 mg/cu.m) with valid u(c)(R(rs)) have a relative uncertainty ≤ 5% at bands 412 nm, 443 nm, and 488 nm respectively, which is a common goal of ocean color retrievals for clear waters. While the analysis shows that u(c)(R(rs)) calculated from our derivative-based method is reasonable, some issues need further investigation, including improved knowledge of forward model uncertainty and systematic uncertainty in instrument calibration.

Pixel-level uncertainty↗

Capacitively Coupled LAPPDs with 2D Pixelated Readout Planes for Time of Flight and Ring Imaging Cherenkov Applications

Large Area Picosecond Photon Detectors (LAPPDs) are micro-channel plate based photosensors featuring hundreds of square centimeters of sensitive area in a single package and capable of providing timing resolution on the order of 50 ps for single photon detection. However, LAPPDs currently do not exist in finely pixelated 2D readout configurations which, in addition to ighresolution timing, would also provide high spatial resolution required for Ring Imaging CHerenkov (RICH) detectors. One of the recent LAPPD models (Gen II) provides the opportunity to overcome the lack of pixellation by coupling an external readout to the sealed detector itself. The readout plane in this case is a simple printed circuit board (PCB) that can be laid out in a custom application-specific way for 1D or 2D sensitive area pixellation. This allows for a much shorter readout-plane prototyping cycle and provides unprecedented flexibility in choosing an appropriate segmentation that can be optimized for any particular detector need in terms of pad size, orientation, and shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing pixel tracklet searches for shorter lifetimes

Pixel tracklets, disappearing tracks reconstructed with only pixel hits, have proven to be a promising technique in LHC analyses to search for dark matter candidates at the LHC that belong to a nearly-degenerate electroweak multiplet. However, a Pseudo-Dirac electroweak doublet fermion, arguably the most interesting such possibility, has a shorter lifetime and therefore existing tracklet searches are less sensitive in this case. We assess the performance of a tracklet search optimized for shorter lifetimes by requiring only three pixel hits for the tracklet reconstruction, and by demanding an accompanying soft track for suppressing backgrounds. We estimate how far the sensitivity of existing searches can be extended into the region of parameter space with this optimized search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam

Here, we present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20-μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized n + sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron–Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AstroPix: A pixelated HVCMOS sensor for space-based gamma-ray measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25–700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 μ m. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 ± 3.2% at 59.5 keV and 94 ± 6 μ m depletion in a low-resistivity test silicon substrate.

Astrophysics instrumentation↗

Rapid sensing of hidden objects and defects using a single-pixel diffractive terahertz sensor

Abstract Terahertz waves offer advantages for nondestructive detection of hidden objects/defects in materials, as they can penetrate most optically-opaque materials. However, existing terahertz inspection systems face throughput and accuracy restrictions due to their limited imaging speed and resolution. Furthermore, machine-vision-based systems using large-pixel-count imaging encounter bottlenecks due to their data storage, transmission and processing requirements. Here, we report a diffractive sensor that rapidly detects hidden defects/objects within a 3D sample using a single-pixel terahertz detector, eliminating sample scanning or image formation/processing. Leveraging deep-learning-optimized diffractive layers, this diffractive sensor can all-optically probe the 3D structural information of samples by outputting a spectrum, directly indicating the presence/absence of hidden structures or defects. We experimentally validated this framework using a single-pixel terahertz time-domain spectroscopy set-up and 3D-printed diffractive layers, successfully detecting unknown hidden defects inside silicon samples. This technique is valuable for applications including security screening, biomedical sensing and industrial quality control.

Li, Jingxi (ORCID:0000000165958680)↗

Convolutional neural networks on the HEALPix sphere: a pixel-based algorithm and its application to CMB data analysis

We describe a novel method for the application of convolutional neural networks (CNNs) to fields defined on the sphere, using the Hierarchical Equal Area Latitude Pixelization scheme (HEALPix). Specifically, we have developed a pixel-based approach to implement convolutional and pooling layers on the spherical surface, similarly to what is commonly done for CNNs applied to Euclidean space. The main advantage of our algorithm is to be fully integrable with existing, highly optimized libraries for NNs (e.g., PyTorch, TensorFlow, etc.). We present two applications of our method: (i) recognition of handwritten digits projected on the sphere; (ii) estimation of cosmological parameter from simulated maps of the cosmic microwave background (CMB). The latter represents the main target of this exploratory work, whose goal is to show the applicability of our CNN to CMB parameter estimation. We have built a simple NN architecture, consisting of four convolutional and pooling layers, and we have used it for all the applications explored herein. Concerning the recognition of handwritten digits, our CNN reaches an accuracy of ~95%, comparable with other existing spherical CNNs, and this is true regardless of the position and orientation of the image on the sphere. For CMB-related applications, we tested the CNN on the estimation of a mock cosmological parameter, defining the angular scale at which the power spectrum of a Gaussian field projected on the sphere peaks. We estimated the value of this parameter directly from simulated maps, in several cases: temperature and polarization maps, presence of white noise, and partially covered maps. For temperature maps, the NN performances are comparable with those from standard spectrum-based Bayesian methods. For polarization, CNNs perform about a factor four worse than standard algorithms. Nonetheless, our results demonstrate, for the first time, that CNNs are able to extract information from polarization fields, both in full-sky and masked maps, and to distinguish between E and B -modes in pixel space. Lastly, we have applied our CNN to the estimation of the Thomson scattering optical depth at reionization ( τ ) from simulated CMB maps. Even without any specific optimization of the NN architecture, we reach an accuracy comparable with standard Bayesian methods. This work represents a first step towards the exploitation of NNs in CMB parameter estimation and demonstrates the feasibility of our approach.

79 ASTRONOMY AND ASTROPHYSICS↗

Alignment, orientation, and Coulomb explosion of difluoroiodobenzene studied with the pixel imaging mass spectrometry (PImMS) camera

Laser-induced adiabatic alignment and mixed-field orientation of 2,6-difluoroiodobenzene (C 6 H 3 F 2 I) molecules are probed by Coulomb explosion imaging following either near-infrared strong-field ionization or extreme-ultraviolet multi-photon inner-shell ionization using free-electron laser pulses. The resulting photoelectrons and fragment ions are captured by a double-sided velocity map imaging spectrometer and projected onto two position-sensitive detectors. The ion side of the spectrometer is equipped with a pixel imaging mass spectrometry camera, a time-stamping pixelated detector that can record the hit positions and arrival times of up to four ions per pixel per acquisition cycle. Thus, the time-of-flight trace and ion momentum distributions for all fragments can be recorded simultaneously. Finally, we show that we can obtain a high degree of one-and three-dimensional alignment and mixed-field orientation and compare the Coulomb explosion process induced at both wavelengths

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spitzer secondary eclipses of the dense, modestly-irradiated, giant exoplanet HAT-P-20b using pixel-level decorrelation

HAT-P-20b is a giant metal-rich exoplanet orbiting a metal-rich star. We analyze two secondary eclipses of the planet in each of the 3.6 and 4.5 μm bands of Warm Spitzer. We have developed a simple, powerful, and radically different method to correct the intra-pixel effect for Warm Spitzer data, which we call pixel-level decorrelation (PLD). PLD corrects the intra-pixel effect very effectively, but without explicitly using—or even measuring—the fluctuations in the apparent position of the stellar image. We illustrate and validate PLD using synthetic and real data and comparing the results to previous analyses. PLD can significantly reduce or eliminate red noise in Spitzer secondary eclipse photometry, even for eclipses that have proven to be intractable using other methods. Our successful PLD analysis of four HAT-P-20b eclipses shows a best-fit blackbody temperature of 1134 ± 29 K, indicating inefficient longitudinal transfer of heat, but lacking evidence for strong molecular absorption. We find sufficient evidence for variability in the 4.5 μm band that the eclipses should be monitored at that wavelength by Spitzer, and this planet should be a high priority for James Webb Space Telescope spectroscopy. All four eclipses occur about 35 minutes after orbital phase 0.5, indicating a slightly eccentric orbit. A joint fit of the eclipse and transit times with extant RV data yields ecosω=0.01352{sub −0.00057}{sup +0.00054} and establishes the small eccentricity of the orbit to high statistical confidence. HAT-P-20b is another excellent candidate for orbital evolution via Kozai migration or other three-body mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Baryon Acoustic Oscillations reconstruction with pixels

Gravitational non-linear evolution induces a shift in the position of the baryon acoustic oscillations (BAO) peak together with a damping and broadening of its shape that bias and degrades the accuracy with which the position of the peak can be determined. BAO reconstruction is a technique developed to undo part of the effect of non-linearities. We present and analyse a reconstruction method that consists of displacing pixels instead of galaxies and whose implementation is easier than the standard reconstruction method. We show that this method is equivalent to the standard reconstruction technique in the limit where the number of pixels becomes very large. This method is particularly useful in surveys where individual galaxies are not resolved, as in 21cm intensity mapping observations. We validate this method by reconstructing mock pixelated maps, that we build from the distribution of matter and halos in real- and redshift-space, from a large set of numerical simulations. We find that this method is able to decrease the uncertainty in the BAO peak position by 30-50% over the typical angular resolution scales of 21 cm intensity mapping experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterisation of the high dynamic range Large Pixel Detector (LPD) and its use at X-ray free electron laser sources

The STFC Rutherford Appleton Laboratory have delivered the Large Pixel Detector (LPD) for MHz frame rate imaging at the European XFEL. The detector system has an active area of 0.5 m × 0.5 m and consists of a million pixels on a 500 μm pitch. Sensors have been produced from 500 μm thick Hammamatsu silicon tiles that have been bump bonded to the readout ASIC using a silver epoxy and gold stud technique. Each pixel of the detector system is capable of measuring 10 5 12 keV photons per image readout at 4.5 MHz. In this paper results from the testing of these detectors at the Diamond Light Source and the Linac Coherent Light Source (LCLS) are presented. As a result, the performance of the detector in terms of linearity, spatial uniformity and the performance of the different ASIC gain stages is characterised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling radiation damage to pixel sensors in the ATLAS detector

Silicon pixel detectors are at the core of the current and planned upgrade of the ATLAS detector at the Large Hadron Collider (LHC) . As the closest detector component to the interaction point, these detectors will be subject to a significant amount of radiation over their lifetime: prior to the High-Luminosity LHC (HL-LHC) [1], the innermost layers will receive a fluence in excess of 1015 neq/cm2 and the HL-LHC detector upgrades must cope with an order of magnitude higher fluence integrated over their lifetimes. Simulating radiation damage is essential in order to make accurate predictions for current and future detector performance that will enable searches for new particles and forces as well as precision measurements of Standard Model particles such as the Higgs boson. We present a digitization model that includes radiation damage effects on the ATLAS pixel sensors for the first time. In addition to thoroughly describing the setup, we present first predictions for basic pixel cluster properties alongside early studies with LHC Run 2 proton-proton collision data.

Ducourthial, A.↗

Design of ePixM, a fully-depleted monolithic CMOS active pixel sensor for soft X-ray experiments at LCLS-II

The LCLS-II Free Electron Laser (FEL) will produce X-ray pulses with a repetition rate of up to 1 MHz and energies between 250 eV and 5 keV. Experiments conducted at LCLS-II will require 2D imaging detectors with a unique set of features, such as high-spatial resolution, low-noise performance, high-dynamic range and high-frame rates up to 1 MHz. We present the design of ePixM, a fully-depleted monolithic CMOS detector tailored for soft X-rays applications at high-repetition rates FEL. It consists of an array of 384×192 active pixel sensors, with a pixel size of 50×50 μm 2 and a total sensitive area of 2×1 cm 2 . ePixM has been designed in a 150 nm CMOS technology on high-resistivity substrate to achieve full depletion of the substrate. Each pixel includes a Charge Sensitive Amplifier (CSA) with gain auto-ranging capability and a noise-shaper performing Correlated Double Sampling (CDS). A novel technique named correlated pre-charging removes the excess noise introduced by the gain-switching mechanism. The performance of the design has been evaluated through post-layout simulations. The Equivalent Noise Charge (ENC) of 11.3 electrons enables single-photon detection at X-ray energies down to 250 eV, and the dynamic range exceeds 10 3 photons at 500 eV thanks to the auto-ranging circuitry.

47 OTHER INSTRUMENTATION↗

In-pixel automatic threshold calibration for the CMS Endcap Timing Layer readout chip

We present the implementation and verification of an in-pixel automatic threshold calibration circuit for the CMS Endcap Timing Layer (ETL) in the High-Luminosity LHC upgrade. The discriminator threshold of the ETL readout chip (ETROC) needs to be calibrated regularly to mitigate the circuit baseline change. Traditional methods need a lot of communication through a slow control system hence are time-consuming. This paper describes an in-pixel automatic scheme with improvements in operating time and usability. In this scheme, a sample-accumulation circuit is used to measure the average discriminator output. A binary successive approximation and linear combination scan are applied to find the equivalent baseline. The actual calibration procedure has been first implemented in FPGA firmware and tested with the ETROC front-end prototype chip (ETROC0). The calibration circuit has been implemented with Triple Modular Redundancy (TMR) and verified with Single Event Effects (SEEs) simulation. A complete calibration process lasts 35 ms with a 40 MHz clock. In the worst case, the dynamic and static power consumption are estimated to be 300 uW and 10.4 uW, respectively. The circuit design, implemented in a 65 CMOS technology, will be integrated into ETROC2, the next iteration of the ETROC with a 16 x16 pixel matrix.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of planar silicon pixel sensors with the RD53A readout chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Large Hadron Collider at CERN will undergo an upgrade inorder to increase its luminosity to7.5 × 10$^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosityduring this High-Luminosity running phase, starting around 2029,means a higher rate of proton-proton interactions, hence a largerionizing dose and particle fluence for the detectors. The currenttracking system of the CMS experiment will be fully replaced inorder to cope with the new operating conditions. Prototype planarpixel sensors for the CMS Inner Tracker with square50 μm × 50 μm and rectangular100 μm × 25 μm pixels read out by theRD53A chip were characterized in the lab and at the DESY-II testbeamfacility in order to identify designs that meet the requirements ofCMS during the High-Luminosity running phase. A spatial resolutionof approximately 3.4 μm (2 μm) is obtained using themodules with 50 μm × 50 μm(100 μm × 25 μm) pixels at the optimalangle of incidence before irradiation. After irradiation to a 1 MeVneutron equivalent fluence ofΦ$_{eq}$ = 5.3 × 10$^{15}$ cm$^{-2}$, a resolution of9.4 μm is achieved at a bias voltage of 800 V using a modulewith 50 μm × 50 μm pixel size. All modulesretain a hit efficiency in excess of 99% after irradiation tofluences up to 2.1 × 10$^{16}$ cm$^{-2}$. Further studies ofthe electrical properties of the modules, especially crosstalk, arealso presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD TM ) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The results of this test confirmed that the coarse-pixelated (2.5 × 2.5 cm 2 pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗