Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photon statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Avalanche photodiode photon counting receivers for space-borne lidars

Avalanche photodiodes (APD) are studied for uses as photon counting detectors in spaceborne lidars. Non-breakdown APD photon counters, in which the APD's are biased below the breakdown point, are shown to outperform: (1) conventional APD photon counters biased above the breakdown point; (2) conventional APD photon counters biased above the breakdown point; and (3) APD's in analog mode when the received optical signal is extremely weak. Non-breakdown APD photon counters were shown experimentally to achieve an effective photon counting quantum efficiency of 5.0 percent at lambda = 820 nm with a dead time of 15 ns and a dark count rate of 7000/s which agreed with the theoretically predicted values. The interarrival times of the counts followed an exponential distribution and the counting statistics appeared to follow a Poisson distribution with no after pulsing. It is predicted that the effective photon counting quantum efficiency can be improved to 18.7 percent at lambda = 820 nm and 1.46 percent at lambda = 1060 nm with a dead time of a few nanoseconds by using more advanced commercially available electronic components.

Sun, Xiaoli↗

Variability analysis in low count rate sources

A method, based on the chi-square statistics, is described for detecting pulselike time variability in low count rate sources observed with photon-counting instruments. This method can be used even in the presence of observational gaps, takes full advantage of the filtering effect due to binning with different bin sizes, and takes into account the arbitrariness introduced by the binning phase. The procedure developed to limit the dependence of the results on the binning phase and ensure statistically correct results is described along with the application of the proposed procedure to a model of a variable source. Monte Carlo simulations are used to show how the method can be used to derive the characteristic variability time scales and that the method is more sensitive than the nonparametric Kolmogorov-Smirnov test in detecting variability to a given confidence level.

Collura, A.↗

A non-Markovian model of avalanche gain statistics for a solid-state photomultiplier

A solid-state photomultiplier (SSPM) capable of continously detecting individual photons of wavelength between 0.4 and 28 microns has recently been disclosed (Petroff et al., 1987). The initial response of the SSPM to single photon is a fast, high-amplitude current pulse of between 10,000 and 100,000 electrons. A phenomenological model of the SSPM avalanche process is presented which successfully predicts the shape of the observed pulse-amplitude distribution by including small history-dependent effects on the carrier transport. The model clarifies the consequences of the electric field strength and the scattering of the electrons for the development of the avalanche in the SSPM.

Laviolette, Randall A.↗

Multiyear Statistics of 2-D Shortwave Radiative Effects at Three ARM Sites

This study examines the importance of horizontal photon transport effects, which are not considered in the 1-D calculations of solar radiative heating used by most atmospheric dynamical models. In particular, the paper analyzes the difference between 2-D and 1-D radiative calculations for 2-D vertical cross-sections of clouds that were observed at three sites over 2- to 3-year periods. The results show that 2-D effects increase multiyear 24-hour average total solar absorption by about 4.1 W/sq m, 1.2 W/sq m, and 0.3 W/sq m at a tropical, mid-latitude, and arctic site, respectively. However, 2-D effects are often much larger than these average values, especially for high sun and for convective clouds. The results also reveal a somewhat unexpected behavior, that horizontal photon transport often enhances solar heating even for oblique sun. These findings underscore the need for fast radiation calculation methods that can allow atmospheric dynamical simulations to consider the inherently multidimensional nature of shortwave radiative processes.

Varnai, Tamas↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ^(2) method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ^(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ^(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

Shinya Yamada↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Double-pion electroproduction off protons in deuterium: Quasifree cross sections and final-state interactions

Here, the single-differential and fully integrated cross sections for quasi-free $π^+π^-$ electroproduction off protons bound in deuterium have been extracted for the first time. The experimental data were collected at Jefferson Laboratory with the CLAS detector. The measurements were performed in the kinematic region of the invariant mass W from 1.3 GeV to 1.825 GeV and photon virtuality Q 2 from 0.4 GeV2 to 1.0 GeV 2 . Sufficient experimental statistics allow for narrow binning in all kinematic variables, while maintaining a small statistical uncertainty. The extracted cross sections were compared with the corresponding cross sections off free protons, which allowed us to obtain an estimate of the contribution from events in which interactions between the final-state hadrons and the spectator neutron took place.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon counting processor for laser velocimetry

In some of the more difficult applications of laser Doppler velocimetry such as in combustion research, transonic flow, transverse wind, and others, the optical signals are too small for classical detection methods. This paper summarizes the theory, experimental prototype hardware, and test results for a new type of high-speed photon-correlation signal processor which is being developed for weak laser velocimeter signals and other photon-resolved signals. The new system may also be considered to be a statistical digital frequency discriminator. It uses full multiplication with 10-nsec delay time and has the potential for extension to the measurement of the velocity correlations and spectra.

Mayo, W. T., Jr.↗

Sources of noise in magneto-optical readout

The various sources of noise which are often encountered in magneto-optical readout systems are analyzed. Although the focus is on magneto-optics, most sources of noise are common among the various optical recording systems and one can easily adapt the results to other media and systems. A description of the magneto-optical readout system under consideration is given, and the standard methods and the relevant terminology of signal and noise measurement are described. The characteristics of thermal noise, which originates in the electronic circuitry of the readout system, are described. The most fundamental of all sources of noise, the shot noise, is considered, and a detailed account of its statistical properties is given. Shot noise, which is due to random fluctuations in photon arrival times, is an ever-present noise in optical detection. Since the performance of magneto-optical recording devices in use today is approaching the limit imposed by the shot noise, it is important that the reader have a good grasp of this particular source of noise. A model for the laser noise is described, and measurement results which yield numerical values for the strength of the laser power fluctuations are presented. Spatial variations of the disk reflectivity and random depolarization phenomena also contribute to the overall level of noise in readout; these and related issues are treated. Numerical simulation results describing some of the more frequently encountered sources of noise which accompany the recorded waveform itself, namely, jitter noise and signal-amplitude fluctuation noise are presented.

Mansuripur, M.↗

An Algorithm for Detection of Ground and Canopy Cover in Micropulse Photon-Counting Lidar Altimeter Data in Preparation of the ICESat-2 Mission

The Ice, Cloud and Land Elevation Satellite-II (ICESat-2) mission has been selected by NASA as a Decadal Survey mission, to be launched in 2016. Mission objectives are to measure land ice elevation, sea ice freeboard/ thickness and changes in these variables and to collect measurements over vegetation that will facilitate determination of canopy height, with an accuracy that will allow prediction of future environmental changes and estimation of sea-level rise. The importance of the ICESat-2 project in estimation of biomass and carbon levels has increased substantially, following the recent cancellation of all other planned NASA missions with vegetation-surveying lidars. Two innovative components will characterize the ICESat-2 lidar: (1) Collection of elevation data by a multi-beam system and (2) application of micropulse lidar (photon counting) technology. A micropulse photon-counting altimeter yields clouds of discrete points, which result from returns of individual photons, and hence new data analysis techniques are required for elevation determination and association of returned points to reflectors of interest including canopy and ground in forested areas. The objective of this paper is to derive and validate an algorithm that allows detection of ground under dense canopy and identification of ground and canopy levels in simulated ICESat-2-type data. Data are based on airborne observations with a Sigma Space micropulse lidar and vary with respect to signal strength, noise levels, photon sampling options and other properties. A mathematical algorithm is developed, using spatial statistical and discrete mathematical concepts, including radial basis functions, density measures, geometrical anisotropy, eigenvectors and geostatistical classification parameters and hyperparameters. Validation shows that the algorithm works very well and that ground and canopy elevation, and hence canopy height, can be expected to be observable with a high accuracy during the ICESat-2 mission. A result relevant for instrument design is that even the two weaker beam classes considered can be expected to yield useful results for vegetation measurements (93.01-99.57% correctly selected points for a beam with expected return of 0.93 mean signals per shot (msp9) and 72.85% - 98.68% for 0.48 msp (msp4)). Resampling options affect results more than noise levels. The algorithm derived here is generally applicable for analysis of micropulse lidar altimeter data collected over forested areas as well as other surfaces, including land ice, sea ice and land surfaces.

Herzfeld, Ute C.↗

Gamma-Ray Emission in Dissipative Pulsar Magnetospheres: from Theory to Fermi Observations

We compute the patterns of gamma-ray emission due to curvature radiation in dissipative pulsar magnetospheres. Our ultimate goal is to construct macrophysical models that are able to reproduce the observed gamma-ray light curve phenomenology recently published in the Second Fermi Pulsar Catalog. We apply specific forms of Ohm's law on the open field lines using a broad range for the macroscopic conductivity values that result in solutions ranging, from near-vacuum to near-force-free. Using these solutions, we generate model gamma-ray light curves by calculating realistic trajectories and Lorentz factors of radiating particles under the influence of both the accelerating electric fields and curvature radiation reaction. We further constrain our models using the observed dependence of the phase lags between the radio and gamma-ray emission on the gamma-ray peak separation. We perform a statistical comparison of our model radio-lag versus peak-separation diagram and the one obtained for the Fermi standard pulsars. We find that for models of uniform conductivity over the entire open magnetic field line region, agreement with observations favors higher values of this parameter. We find, however, significant improvement in fitting the data with models that employ a hybrid form of conductivity, specifically, infinite conductivity interior to the light cylinder and high but finite conductivity on the outside. In these models the gamma-ray emission is produced in regions near the equatorial current sheet but modulated by the local physical properties. These models have radio lags near the observed values and statistically best reproduce the observed light curve phenomenology. Additionally, they also produce GeV photon cut-off energies.

stars↗

MicroBooNE investigations on the photon interpretation of the MiniBooNE low energy excess

The MicroBooNE experiment is a liquid argon time projection chamber with 85-ton active volume at Fermilab, operated from 2015 to 2020 to collect neutrino data from Fermilab's Booster Neutrino Beam. One of MicroBooNE's physics goals is to investigate possible explanations of the low-energy excess observed by the MiniBooNE experiment in $\nu_{\mu}\rightarrow \nu_{e}$ neutrino oscillation measurements. MicroBooNE has performed searches to test hypothetical interpretations of the MiniBooNE low-energy excess, including the underestimation of the photon background or instrinic $\nu_{e}$ background. This thesis presents MicroBooNE's searches for two neutral current (NC) single-photon production processes that contribute to the photon background of the MiniBooNE measurement: NC $\Delta$ resonance production followed by $\Delta$ radiative decay: $\Delta \rightarrow N\gamma$, and NC coherent single-photon production. Both searches take advantage of boosted decision trees to yield efficient background rejection, and a high-statistic NC $\pi^0$ measurement to constrain dominant background, and make use of MicroBooNE's first three years of data. The NC $\Delta \rightarrow N\gamma$ measurement yielded a bound on the $\Delta$ radiative decay process at 2.3 times the predicted nominal rate at 90\% confidence level(C.L.), disfavoring a candidate photon interpretation of the MiniBooNE low-energy excess as a factor of 3.18 times the nominal NC Δ radiative decay rate at the 94.8\% C.L. The NC coherent single photon measurement leads to the world's first experimental limit on the cross-section of this process below 1 GeV, of $1.49 \times 10^{-41} \text{cm}^2$ at 90\% C.L., corresponding to 24.0 times the nominal prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Classical H II regions in the Magellanic Clouds. 2: Stellar content

In this second in a series of papers on the nature of classical H II regions in the Magellanic Clouds I investigate the properties of the underlying stellar content of the nebulae. Particular emphasis is placed on identifying and classifying the ionizing source(s) for each H II region. With the exception of the LMC H II regions DEM 20 and DEM 8c, I find that all of the objects in this sample are ionized by more than one O or B star. Even the faintest H II regions reflect the formation of a handful of massive, albeit early B type, stars. Typically, one star accounts for 60% - 70% of the ionizing photons and 2 - 5 less massive stars provide the remaining 30% - 40%. From the statistics of the hottest stars in these H II regions, and from considering all the blue stars contained within each region, the distribution of massive stars with spectral type is consistent with results found in similar galactic H II regions.

Wilcots, Eric M.↗

Optical cycling on thorium monoxide for an improved test of fundamental symmetries

Optical cycling refers to repeated excitation and spontaneous emission on an electronic transition in an atom or molecule. Optical cycling in molecules can enable a wide range of quantum control and readout techniques, but unfortunately it has only been demonstrated on a small class of alkalilike or alkaline-earth-like molecules. Thorium monoxide (ThO), a molecule used in one of the most precise permanent electron electric dipole moment (eEDM) searches (ACME†) [Andreev et al., Nature (London) 562, 355 (2018)], does not fall into this category. In this work, we demonstrate the first optical cycling on this nonconventional class over a range of experimental parameter space, including laser intensity, polarization switching rate, and interaction time. We show that both the 𝐽 = 1 and 𝐽 = 2 rotational levels of ThO molecule are capable of cycling an average of 11(2) photons with a single laser, at scattering rates of 1.9⁢(6) × 10 6 and 2.3⁢(7) × 10 6 s −1 , respectively, before population is lost to other vibronic levels. We outline a scheme to apply this demonstrated optical cycling in an ACME-style eEDM measurement, improving the detection efficiency by over fourfold compared to noncycling fluorescence detection. This would lead to over a twofold enhancement in the statistical sensitivity of the eEDM search. This optical-cycling scheme can be further extended to scatter ∼100 photons, which would enable a wider range of quantum control and sensing using ThO molecules.

Atomic & molecular processes in external fields↗

X-ray observations of a flare in NGC4151 from OSO-8

The 2-60 keV flux from NGC4151 changed by a factor of two on a timescale of 1.5 days. No fluctuations were detected in excess of a factor of three on timescales less than four hours. During a total observation of approximately 11 days there were no statistically significant changes in spectral shape. The spectrum was fitted by a power law with photon index alpha approximately 1.42 + or - 0.06 and column density N sub H approximately 7.5 + or - 0.5 x 10 to the 22d power at/cu cm. A 2 sigma residual to this fit implies fluorescent Fe line emission with E. W. approximately 240 eV. Both synchrotron self-Compton and thermal Compton models are consistent with the X-ray data.

Mushotzky, R. F.↗

Cyclotron resonant scattering in gamma-ray bursts - Further analysis of GB880205

We have extended our previous work by exploring several plane-parallel slab geometries to model the formation of cyclotron line features. We calculated the Compton temperature T(C) as a function of column density Ne for each of the new geometries. We then fit the resulting spectra to GB880205 exactly as described in Wang et al. (1989). The results show that the addition of column depth below the photon source plane leads to a modest improvement in chi-squared which, although not statistically significant, is pleasing because these geometries are more physically realistic.

Freeman, P. E.↗

Signal detection amid noise with known statistics

Conventional methods of signal detection are based on the comparison of a local signal-to-noise ratio S/N to some threshold value. We present a new method that compares instead the histogram of the data with the one expected for background noise alone. Signals are detected from discrepancies between the two. We expect it to be applicable in the detection of signals from any data whose background statistics is known. To illustrate the method, we apply it to the case of photon-limited imaging data where the underlying background is Poissonian. Numerical simulations are used to check the efficiency of our method, finding that for signals with low S/N (less than 5), it detects signals with a higher degree of reliability than the conventional method.

Zepka, A. F.↗

EVAP: A two-photon imaging tool to study conformational changes in endogenous Kv2 channels in live tissues

A primary goal of molecular physiology is to understand how conformational changes of proteins affect the function of cells, tissues, and organisms. Here, we describe an imaging method for measuring the conformational changes of the voltage sensors of endogenous ion channel proteins within live tissue, without genetic modification. We synthesized GxTX-594, a variant of the peptidyl tarantula toxin guangxitoxin-1E, conjugated to a fluorophore optimal for two-photon excitation imaging through light-scattering tissue. We term this tool EVAP (Endogenous Voltage-sensor Activity Probe). GxTX-594 targets the voltage sensors of Kv2 proteins, which form potassium channels and plasma membrane–endoplasmic reticulum junctions. GxTX-594 dynamically labels Kv2 proteins on cell surfaces in response to voltage stimulation. To interpret dynamic changes in fluorescence intensity, we developed a statistical thermodynamic model that relates the conformational changes of Kv2 voltage sensors to degree of labeling. We used two-photon excitation imaging of rat brain slices to image Kv2 proteins in neurons. We found puncta of GxTX-594 on hippocampal CA1 neurons that responded to voltage stimulation and retain a voltage response roughly similar to heterologously expressed Kv2.1 protein. Our findings show that EVAP imaging methods enable the identification of conformational changes of endogenous Kv2 voltage sensors in tissue.

59 BASIC BIOLOGICAL SCIENCES↗