Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photocathode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Single shot cathode transverse momentum imaging in high brightness photoinjectors

In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emittance per rms laser spot size, is proposed for photocathode rf guns. By tuning the gun solenoid focusing, the electrons’ transverse momenta at the cathode are imaged to a downstream screen, which enables a single shot measurement of both the rms value and the detailed spectra of the photoelectrons’ transverse momenta. Both simulations and proof of principle experiments are reported.

43 PARTICLE ACCELERATORS↗

Experimental Characterization of Photoemission from Plasmonic Nanogroove Arrays

Metal photocathodes are an important source of high-brightness electron beams, ubiquitous in the operation of both large-scale accelerators and table-top microscopes. When the surface of a metal is nanoengineered with patterns on the order of the optical wavelength, it can lead to the excitation and confinement of surface-plasmon-polariton waves that drive nonlinear photoemission. In this work, we aim to evaluate gold plasmonic nanogrooves as a concept for producing bright electron beams for accelerators via nonlinear photoemission. Here, we do this by first comparing their optical properties to numerical calculations from first principles to confirm our ability to fabricate these nanoscale structures. Their nonlinear photoemission yield is found by measuring emitted photocurrent as the intensity of their driving laser is varied. Finally, the mean transverse energy of this electron source is found using the solenoid-scan technique. Our data demonstrate the ability of these cathodes to provide a tenfold enhancement in the efficiency of photoemission over flat metals driven with a linear process. We find that these cathodes are robust and capable of reaching sustained average currents over 100 nA at optical intensities larger than 2 GW cm –2 with no degradation of performance. The emittance of the generated beam is found to be highly asymmetric, a fact we can explain with calculations involving the also asymmetric roughness of the patterned surface. These results demonstrate the use of nanoengineered surfaces as enhanced photocathodes, providing a robust air-stable source of high-average-current electron beams hopefully with great potential for industrial and scientific applications.

47 OTHER INSTRUMENTATION↗

Importance of bulk excitations and coherent electron-photon-phonon scattering in photoemission from PbTe(111): Ab initio theory with experimental comparisons

This paper presents a fully ab initio many-body photoemission framework that includes coherent three-body electron-photon-phonon scattering to predict the transverse momentum distributions and the mean transverse energies (MTEs) of bulk photoelectrons from single-crystal photocathodes. The need to develop such a theory stems from the lack of studies that provide complete understanding of the underlying fundamental processes governing the transverse momentum distribution of photoelectrons emitted from single crystals. For example, initial predictions based on density-functional theory calculations of effective electron masses suggested that the (111) surface of PbTe would produce very small MTEs (≤ 15 meV), whereas our experiments yielded MTEs ten to twenty times larger than these predictions and also exhibited a lower photoemission threshold than predicted. The ab initio framework presented in this paper correctly reproduces both the magnitude of the MTEs from our measurements in PbTe(111) and the observed photoemission below the predicted threshold. Our results show that both photoexcitations into states that propagate in the bulk of the material and coherent many-body electron-photon-phonon scattering processes, which initial predictions ignored, play surprisingly important roles in photoemission from PbTe(111). Lastly, from the lessons learned, we recommend a procedure for rapid computational screening of potential single-crystal photocathodes for applications in next-generation ultrafast electron diffraction and X-ray free-electron lasers, which will enable significant advances in condensed matter research.

36 MATERIALS SCIENCE↗

High-Brightness Continuous-Wave Electron Beams from Superconducting Radio-Frequency Photoemission Gun

Continuous-wave photoinjectors operating at high accelerating gradients promise to revolutionize many areas of science and applications. They can establish the basis for a new generation of monochromatic x-ray free electron lasers, high-brightness hadron beams, or a new generation of microchip production. In this Letter we report on the record-performing superconducting rf electron gun with CsK 2 Sb photocathode. The gun is generating high charge electron bunches (up to 10 nC / bunch ) and low transverse emittances, while operating for months with a single photocathode. As such, this achievement opens a new era in generating high-power beams with a very high average brightness.

43 PARTICLE ACCELERATORS↗

Improving the Operational Lifetime of the CEBAF Photo-Gun by Anode Biasing

The operating lifetime of GaAs-based photocathodes in DC high voltage electron photo-guns is dominated by the ionization rate of residual beamline gas molecules. In this work, experiments were performed to quantify the improvement in photocathode charge lifetime by biasing the photo-gun anode with a positive voltage, which repels ions generated downstream of the anode. The photo-cathode charge lifetime improved by almost a factor of two when the anode was biased compared to the usual grounded configuration. Simulations were performed using the particle tracking code General Particle Tracer (GPT) with a new custom element. The simulation results showed that both the number and energy of ions play a role in the pattern of QE degradation. The experiment results and conclusions supported by GPT simulations will be presented.

Yoskowitz, J. T.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Toward a long-lifetime polarized photoelectron gun for the Ce+BAF positron source

The addition of spin-polarized, continuous-wave (c.w.) positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) would provide a significant capability to the experimental nuclear physics program at Jefferson Lab. Based on bremsstrahlung and pair-production in a high-Z target, the positron source requires a 120 MeV spin-polarized c.w. electron beam of several milliamperes. While the beam dynamics of the high-current electron beam are tenable, sustaining this current for weeks of user operations requires an unprecedented charge lifetime from a high-polarization GaAs-based photocathode. A promising approach to exceed the kilocoulomb charge lifetime barrier is reducing the ion back-bombardment fluence at the photocathode. By increasing the laser size and managing the emittance growth with an adequate cathode/anode design, significantly enhanced charge lifetime may be achieved. Based upon a new simulation model that qualitatively explains the lifetime data previously measured at different spot sizes, we describe the practical implications on the parameter space available for a kilocoulomb-lifetime polarized photogun design.

Bruker, M.↗

Improved Electrostatic Design of the Jefferson Lab 300 kV DC Photogun and the Minimization of Beam Deflection

An electron beam with high bunch charge and high repetition rate is required for electron cooling of the ion beam to achieve the high luminosity required for the proposed electron-ion colliders. An improved design of the 300 kV DC high voltage photogun at Jefferson Lab was incorporated toward overcoming the beam loss and space charge current limitation experienced in the original design. To reach the bunch charge goal of ~ few nC within 75 ps bunches, the existing DC high voltage photogun electrodes and anode-cathode gap were modified to increase the longitudinal electric field (Ez) at the photocathode. The anode-cathode gap was reduced to increase the Ez at the photocathode, and the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the geometric asymmetry of the inverted insulator photogun. The electrostatic design and beam dynamics simulations were performed to determine the required modification. Beam-based measurement from the modified gun confirmed the reduction of the beam deflection, which is presented in this contribution.

Mamun, M. A.↗

Search for Lepton Number Violation in 136 Xe and 134 Xe Decay

The EXO-200/nEXO group at Stony Brook University led by Krishna Kumar searched for neutrinoless double beta decay of 134 Xe and 136 Xe via participation in the final phase of the EXO-200 experiment and calibration pre-R&D for the next generation nEXO concept. On EXO-200, we carried out an improved analysis in the search for 134 Xe using data from Phase-II running. On nEXO, we completed a paper on our first phase of measurements demonstrating the feasibility of using photoelectricity from a gold photocathode to produce controlled amounts of charged clusters in liquid xenon. This has set the stage to develop a new test stand to evaluate the stability of a gold photocathode in order to explore the sensitivity of this method to monitor long electron lifetimes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Platinum group metal-free (PGM-free) integrated tandem junction photoelectrochemical (PEC) water splitting devices (Final Technical Report)

This project involves using solar light, a photoabsorber, and a catalyst to split water and produce hydrogen. The Department of Energy (DOE) targets for integrated photoelectrochemical (PEC) cells emphasize cost (electrode cost < $200/m 2 ), performance (> 15% solar to hydrogen (STH) efficiency), and stability (> 6 months electrode lifetime), but most approaches skew toward one specific metric. This project exploited interfacial integration of platinum group metal-free (PGM-free) catalysts on the high performance and high value tandem solar cells to attain or exceed the DOE benchmark STH energy conversion efficiency and durability. This was investigated in two thrusts by developing two PEC devices for direct comparison: the first is a high-performance monolithic device based on state-of-the-art GaInP 2 /GaAs tandem solar cells developed at National Renewable Energy Laboratory (NREL), and the second is a high-value device based on earth-abundant wide band gap photoabsorber materials including oxynitride and hybrid organic-inorganic perovskite (HOIP) coupled with commercial narrow band gap silicon (Si). Both these devices were paired with electrocatalysts developed for this purpose at Rutgers University by adapting them to thin films on the photoabsorbers. These catalysts are based on the hydrogen evolution reaction (HER) catalysts (Ni 5 P 4 ), oxygen evolution reaction (OER) catalysts (LiCo 2 O 4 ) previously developed at Rutgers for high-efficiency electrolyzers. For using the high-performance tandem solar cell and Ni 5 P 4 catalysts, we achieved a durability of > 200 h at a STH efficiency of > 10%. For using the high-value wide band gap single junction solar cells on n + Si, we achieved 0.73 mA/cm 2 at 1.23V vs reversible hydrogen electrode (RHE) and -15.9 mA/cm 2 at 0V vs RHE using the oxynitride- and HOIP-based photoelectrodes, respectively. After comparing their photocurrent densities, we down selected the HOIP photoabsorber to couple Si for fabrication of a tandem photocathode. However, due to the COVID-19 pandemic, both the laboratories at Rutgers and NREL were locked down for three months and reopened only partially in 2020. The HOIP/Si tandem photocathode using robust nickel phosphide thin film catalysts cannot be developed within the project period, which is expected to achieve a STH efficiency of > 20%. Also, the low-cost LiCo 2 O 4 OER catalysts need to replace the benchmark IrO 2 for evaluation. Finally, techonomic analysis of full high-performance and high-value integrated PEC devices needs to be carried out for comparison in terms of cost.

08 HYDROGEN↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Toward a long-lifetime polarized photoelectron gun for the Ce+BAF positron source

The addition of spin-polarized, continuous-wave (c.w.) positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) would provide a significant capability to the experimental nuclear physics program at Jefferson Lab. Based on bremsstrahlung and pair-production in a high-Z target, the positron source requires a 120 MeV spin-polarized c.w. electron beam of several milliamperes. While the beam dynamics of the high-current electron beam are tenable, sustaining this current for weeks of user operations requires an unprecedented charge lifetime from a high-polarization GaAs-based photocathode. A promising approach to exceed the kilocoulomb charge lifetime barrier is reducing the ion back-bombardment fluence at the photocathode. By increasing the laser size and managing the emittance growth with an adequate cathode/anode design, significantly enhanced charge lifetime may be achieved. Based upon a new simulation model that qualitatively explains the lifetime data previously measured at different spot sizes, we describe the practical implications on the parameter space available for a kilocoulomb-lifetime polarized photogun design.

Bruker, M.↗

An R&D program for milliampere spin-polarized electron beams

The electron injector driving the positron conversion target for Ce+BAF requires a spin-polarized beam with at least 1 mA of average current. While the parameters are not unusual from a beam dynamics point of view, the high average current is challenging due to the finite charge lifetime of the GaAs-based high-polarization photocathodes, even when operated in state-of-the-art load-lock photo-guns. We discuss the dominant limitations and present a systematic experimental program at the Gun Test Stand aiming to overcome them. With a multi-pronged approach involving a redesign of the photo-gun electrodes and an optimized drive laser profile, we hope to demonstrate a charge lifetime in excess of 1 kC from a high-polarization photocathode, mitigating one of the main risks in the injector design.

Bruker, Max [Thomas Jefferson National Accelerator↗

LDRD for a high-current polarized-beam photogun

The electron accelerator driving the Ce+BAF conversion target requires a spin-polarized photogun capable of delivering a CW beam current of at least 1 mA. As the high beam current limits the useful operating time of the gun between photocathode reactivations due to ion back-bombardment, it is critical to increase the charge lifetime. A Jefferson Lab LDRD project aims to calibrate the simulation models needed to predict photocathode lifetime as a function of electrostatic optics and drive laser parameters in order to design a gun providing at least 1000 C charge lifetime. A prototype gun demonstrating the validity of the scaling predictions will be built and tested at the Gun Test Stand. I will describe the background and progress of this project and give an outlook on the expected performance.

Bruker, Max [Thomas Jefferson National Accelerator↗

New Simulations for Ion-Production and Back-Bombardment in GaAs Photo-guns

GaAs-based DC high voltage photo-guns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed high average current facilities that must operate at tens of milliamperes or more. Specifically, the operating lifetime is dominated by ion back-bombardment of the photocathode from ionized residual gas. While numerous experiments have been performed to characterize the operating lifetime under various conditions, detailed simulations of the ion back-bombardment mechanism that explains these experiments are lacking. Recently, a new user routine was implemented using the code General Particle Tracer (GPT) to simulate electron impact ionization of residual beam line gas and simultaneously track the incident electron, the ejected electron, and the newly formed ion. This new routine was benchmarked against analytical calculations and then applied to experiments performed at the CEBAF injector at the Thomas Jefferson National Accelerator Facility to study the effectiveness of limiting ions from entering the cathode-anode gap using a positively biased anode. These simulations were performed using detailed 3D field maps produced with CST Microwave Studio describing the photo-gun electrostatics. Discussion of the experiment and the application of this new GPT routine to model the experiments will be presented at the workshop.

Yoskowitz, Joshua↗

Electrostatic Design and Characterization of a 200 keV Photogun and Wien Spin Rotator

High-energy nuclear physics experiments at the Jefferson Lab Continuous Electron Beam Accelerator Facility (CEBAF) require high spin-polarization electron beams produced from strained super-lattice GaAs photocathodes activated to negative electron affinity in a high voltage photogun operating at 130 kV dc. A pair of Wien filter spin rotators in the injector provides precise control of the electron beam polarization at the end station target. An upgrade of the CEBAF injector to better support the upcoming Moller experiment requires increasing the electron beam energy to 200 keV, resulting in better transmission through injector apertures and improved photocathode lifetime. In addition, the energy increase is expected to reduce unwanted helicity correlated intensity and position systematics. These requirements led to the design of a shielding electrode described in this work, which minimizes the electric field at the triple-point junction and linearizes the potential along the insulator, thus reducing the risk of field emission induced insulator arcing. The Wien spin rotator design was modified for increasing the electric field from 1.6 to 2.7 MV/m and the magnetic field from 9.1 to 13 mT. The upgrades required detailed modeling in Solidworks, electrostatic simulations using CST, beam dynamics using GPT, device implementation, and in situ high voltage characterization of the world?s first 200 keV polarized photoelectron gun and compatible Wien filter spin rotator.

Palacios-Serrano, Gabriel↗

Opportunities for Bright Beam Generation at the Argonne Wakefield Accelerator (AWA)

Bright electron beams have played a critical role in many recent advances in accelerator technology. Producing bright beams via photo-emission is ultimately limited by the mean transverse energy (MTE), which is determined by the photocathode. This paper discusses the opportunity to generate bright electron beams using an upgraded version of the Argonne Wakefield Accelerator (AWA) photo-injector. The focus of this study is to examine the optimal configurations of the AWA photo-injector to produce 100 pC with a ∼100 nm transverse emittance (corresponding to a 5D brightness B5≥1015 A·m−2). The numerical optimization of the AWA photo-injector operating point, including realistic electromagnetic field maps, is presented for the different types of photocathodes under consideration.

Frame, Emily↗

Alkali semi-metal films and method and apparatus for fabricating them

Methods and systems for fabricating a film, such as, for example, a photocathode, having a tailored band structure and thin-film components that can be tailored for specific applications, such as, for example photocathode having a high quantum efficiency, and simple components fabricated by those methods.

Bhandari, Harish B.↗