Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phase correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Tensor power spectrum with holonomy corrections in loop quantum cosmology

In this paper we consider tensor perturbations produced at a bounce phase in the presence of holonomy corrections. Here, the bounce phase and holonomy corrections originate from loop quantum cosmology. We rederive formulas for the corrections of a model with scalar field content. Background dynamics with a free scalar field and multifluid potential are considered. Because the considerations are semiclassical, effects of quantum fluctuations of the background dynamics are not taken into account. Quantum and classical backreaction effects are also neglected. To find the spectrum of the gravitational waves, both analytical approximations and numerical investigations are performed. We have found analytical solutions on superhorizontal and subhorizontal regimes and derived the corresponding tensor power spectra. Also, the occupation number n{sub k} and the parameter {omega}{sub gw} were derived in the subhorizontal limit, leading to the extremely low present value of {omega}{sub gw}. The final results are the numerical power spectra of the gravitational waves produced in the presence of quantum holonomy corrections. The spectrum obtained has two UV and IR branches where P{sub T}{proportional_to}k{sup 2}; however, they have different prefactors. The spectrum connecting these regions is in the form of oscillations. We have found good agreement between the numerical spectrum and the spectrum obtained from the analytical model. The obtained spectrum can be directly applied as an initial condition for the inflationary modes. Based on our results, we discuss implications on the CMB radiation, in particular, on B-type polarization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonsingular cosmology with a scale-invariant spectrum of cosmological perturbations from Lee-Wick theory

We study the cosmology of a Lee-Wick type scalar field theory. First, we consider homogeneous and isotropic background solutions and find that they are nonsingular, leading to cosmological bounces. Next, we analyze the spectrum of cosmological perturbations which result from this model. Unless either the potential of the Lee-Wick theory or the initial conditions are finely tuned, it is impossible to obtain background solutions which have a sufficiently long period of inflation after the bounce. More interestingly, however, we find that in the generic noninflationary bouncing cosmology, perturbations created from quantum vacuum fluctuations in the contracting phase have the correct form to lead to a scale-invariant spectrum of metric inhomogeneities in the expanding phase. Since the background is nonsingular, the evolution of the fluctuations is defined unambiguously through the bounce. We also analyze the evolution of fluctuations which emerge from thermal initial conditions in the contracting phase. The spectrum of gravitational waves stemming from quantum vacuum fluctuations in the contracting phase is also scale-invariant, and the tensor to scalar ratio is not suppressed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transceivers and receivers for discrete-variable quantum key distribution

Various technologies for performing discrete-variable (DV) quantum key distribution (QKD) with integrated electro-optical circuits are described herein. An integrated DV-QKD system uses Mach-Zehnder modulators (MZMs) to modulate a polarization of photons at a transmitter and select a photon polarization measurement basis at a receiver. A transmitter of a DV-QKD system further uses phase shifters to correct for non-idealities of the MZM in output provided to a polarization beam splitter. A receiver of a DV-QKD system can use phase shifters between a polarization beam splitter and an MZM to correct for non-idealities of the polarization beam splitter and the MZM on the receiver side.

Lentine, Anthony L.↗

Neutrino oscillations in the gravitational field

We calculate the gravitational correction to the phase difference between neutrino mass eigenstates for the spherically symmetric gravitational field described by the Schwarzschild metric. This correction was calculated in a number of works, but the results of these works differ from each other. Our result does not coincide with the results ever published. In this work, we make calculations in the simplest way and verify our result by several tests.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CERN Large hadron collider optics model, measurements, and corrections

Optics stability during all phases of operation is crucial for the LHC. Tools and procedures have been developed for rapid checks of beta beating, dispersion, and linear coupling, as well as for prompt optics corrections. Important optics errors during the different phases of the beam commissioning were observed and locally corrected using the segment-by-segment technique. The most relevant corrections at injection have been corroborated with dedicated magnetic measurements.

43 PARTICLE ACCELERATORS↗

Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum improvement of the NCC value by 100% and of the RMSD value by 81%. The corresponding maximum improvements for the registration-based approach were 20% and 40%. In phases with very rapid motion the registration-based algorithm obtained better image quality, while the image quality of the MAM algorithm was superior in phases with less motion. The image quality improvement of the MAM optimization was visually confirmed for the different clinical cases. Conclusions: The proposed method allows a software-based best-phase image quality improvement in coronary CT angiography. A short scan data interval at the target heart phase is sufficient, no additional scan data in other cardiac phases are required. The algorithm is therefore directly applicable to any standard cardiac CT acquisition protocol.

60 APPLIED LIFE SCIENCES↗

Berry-like phases in structured atoms and molecules

Quantum mechanical phases arising from a periodically varying Hamiltonian are considered. These phases are derived from the eigenvalues of a stationary, 'dressed' Hamiltonian that is able to treat internal atomic or molecular structure in addition to the time variation. In the limit of an adiabatic time variation, the usual Berry phase is recovered. For more rapid variation, nonadiabatic corrections to the Berry phase are recovered in perturbation theory, and their explicit dependence on internal structure emerges. Simple demonstrations of this formalism are given, to particles containing interacting spins, and to molecules in electric fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous dual-wavelength reflection digital holography applied to the study of the porous coal samples

We present a simultaneous dual-wavelength phase-imaging digital holographic technique demonstrated on porous coal samples. The use of two wavelengths enables us to increase the axial range at which the unambiguous phase imaging can be performed, but also increases the noise. We employ a noise reduction 'fine map' algorithm, which uses the two-wavelength phase map as a guide to correct a single-wavelength phase image. Then, the resulting noise of a fine map is reduced to the level of single-wavelength noise. A comparison to software unwrapping is also presented. A simple way of correcting a curvature mismatch between the reference and the object beams is offered.

01 COAL, LIGNITE, AND PEAT↗

Effects of bulk viscosity at freezeout

We investigate particle spectra and elliptic flow coefficients in relativistic heavy-ion collisions by taking into account the distortion of phase space distributions by bulk viscosity at freezeout. We first calculate the distortion of phase space distributions in a multicomponent system with Grad's 14-moment method. We find some subtle issues when macroscopic variables are matched with microscopic momentum distributions in a multicomponent system, and we develop a consistent procedure to uniquely determine the corrections to the phase space distributions. Next, we calculate particle spectra by using the Cooper-Frye formula to see the effect of the bulk viscosity. Despite the relative smallness of the bulk viscosity, we find that it is likely to have a visible effect on particle spectra and elliptic flow coefficients. This indicates the importance of taking into account bulk viscosity together with shear viscosity to constrain the transport coefficients with better accuracy from comparison with experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine Learning Potentials with the Iterative Boltzmann Inversion: Training to Experiment

Methodologies for training machine learning potentials (MLPs) with quantum-mechanical simulation data have recently seen tremendous progress. Experimental data have a very different character than simulated data, and most MLP training procedures cannot be easily adapted to incorporate both types of data into the training process. Here, we investigate a training procedure based on iterative Boltzmann inversion that produces a pair potential correction to an existing MLP using equilibrium radial distribution function data. By applying these corrections to an MLP for pure aluminum based on density functional theory, we observe that the resulting model largely addresses previous overstructuring in the melt phase. Interestingly, the corrected MLP also exhibits improved performance in predicting experimental diffusion constants, which are not included in the training procedure. The presented method does not require autodifferentiating through a molecular dynamics solver and does not make assumptions about the MLP architecture. Our results suggest a practical framework for incorporating experimental data into machine learning models to improve the accuracy of molecular dynamics simulations.

36 MATERIALS SCIENCE↗

SiC MOSFET Based Single Phase Active Boost Rectifier with Power Factor Correction for Wireless Power Transfer Applications

Wireless Power Transfer (WPT) technology is a novel research area in the charging technology that bridges the utility and the automotive industries. There are various solutions that are currently being evaluated by several research teams to find the most efficient way to manage the power flow from the grid to the vehicle energy storage system. There are different control parameters that can be utilized to compensate for the change in the impedance due to variable parameters such as battery state-of-charge, coupling factor, and coil misalignment. This paper presents the implementation of an active front-end rectifier on the grid side for power factor control and voltage boost capability for load power regulation. The proposed SiC MOSFET based single phase active front end rectifier with PFC resulted in >97% efficiency at 137mm air-gap and >95% efficiency at 160mm air-gap.

active rectifier↗

Formation of a non-Gaussian intensity profile in a waveguide quasi-optical resonator with an aspherical reflector

A method of phase conjugation for formation of non-Gaussian light beams with the specified transverse intensity distribution in waveguide quasi-optical resonators is described. The method is based on the correction of the phase of the fundamental resonator mode by changing the shape of one of the reflectors. The possibility of producing beams with the super-Gaussian and doughnut-like intensity profiles in a waveguide resonator with an aspherical mirror is shown theoretically. The region of geometrical parameters of the resonator is found for which the difference between the phase functions of aspherical and convex spherical resonators is small. The existence of beams with the super-Gaussian intensity profile at the output of a waveguide submillimetre ({lambda} = 0.4326 mm) resonator with a convex spherical mirror is confirmed experimentally. (waveguides and resonators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical synchronization system for femtosecond X-ray sources

Femtosecond pump/probe experiments using short X-Ray and optical pulses require precise synchronization between 100 meter-10 km separated lasers in a various experiments. For stabilization in the hundred femtosecond range a CW laser is amplitude modulated at 1-10 GHz, the signal retroreflected from the far end, and the relative phase used to correct the transit time with various implementations. For the sub-10 fsec range the laser frequency itself is upshifted 55 MHz with an acousto-optical modulator, retroreflected, upshifted again and phase compared at the sending end to a 110 MHz reference. Initial experiments indicate less than 1 fsec timing jitter. To lock lasers in the sub-10 fs range two single-frequency lasers separated by several teraHertz will be lock to a master modelocked fiber laser, transmit the two frequencies over fiber, and lock two comb lines of a slave laser to these frequencies, thus synchronizing the two modelocked laser envelopes.

47 OTHER INSTRUMENTATION↗

Attosecond transient absorption instrumentation for thin film materials: Phase transitions, heat dissipation, signal stabilization, timing correction, and rapid sample rotation

We present an extreme ultraviolet (XUV) transient absorption apparatus tailored to attosecond and femtosecond measurements on bulk solid-state thin-film samples, specifically when the sample dynamics are sensitive to heating effects. The setup combines methodology for stabilizing sub-femtosecond time-resolution measurements over 48 h and techniques for mitigating heat buildup in temperature-dependent samples. Single-point beam stabilization in pump and probe arms and periodic time-zero reference measurements are described for accurate timing and stabilization. A hollow-shaft motor configuration for rapid sample rotation, raster scanning capability, and additional diagnostics are described for heat mitigation. Heat transfer simulations performed using a finite element analysis allow comparison of sample rotation and traditional raster scanning techniques for 100 Hz pulsed laser measurements on vanadium dioxide, a material that undergoes an insulator-to-metal transition at a modest temperature of 340 K. Experimental results are presented confirming that the vanadium dioxide (VO 2 ) sample cannot cool below its phase transition temperature between laser pulses without rapid rotation, in agreement with the simulations. The findings indicate the stringent conditions required to perform rigorous broadband XUV time-resolved absorption measurements on bulk solid-state samples, particularly those with temperature sensitivity, and elucidate a clear methodology to perform them.

47 OTHER INSTRUMENTATION↗

Generalized perturbations in neutrino mixing

We derive here expressions for the neutrino mixing parameters that result from complex perturbations on (1) the Majorana neutrino mass matrix (in the basis of charged lepton mass eigenstates) and on (2) the charged lepton mass matrix, for arbitrary initial (unperturbed) mixing matrices. In the first case, we find that the phases of the elements of the perturbation matrix, and the initial values of the Dirac and Majorana phases, strongly impact the leading order corrections to the neutrino mixing parameters and phases. For experimentally compatible scenarios wherein the initial neutrino mass matrix has μ-τ symmetry, we discovef that the Dirac phase can take any value under small perturbations. Similarly, in the second case, perturbations to the charged lepton mass matrix can generate large corrections to the mixing angles and phases of the PMNS matrix. As an demonstration of our generalized procedure, we apply it to a situation in which nonstandard scalar and nonstandard vector interactions simultaneously affect neutrino oscillations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Predicting ptychography probe positions using single-shot phase retrieval neural network

Ptychography is a powerful imaging technique that is used in a variety of fields, including materials science, biology, and nanotechnology. However, the accuracy of the reconstructed ptychography image is highly dependent on the accuracy of the recorded probe positions which often contain errors. These errors are typically corrected jointly with phase retrieval through numerical optimization approaches. When the error accumulates along the scan path or when the error magnitude is large, these approaches may not converge with satisfactory result. We propose a fundamentally new approach for ptychography probe position prediction for data with large position errors, where a neural network is used to make single-shot phase retrieval on individual diffraction patterns, yielding the object image at each scan point. The pairwise offsets among these images are then found using a robust image registration method, and the results are combined to yield the complete scan path by constructing and solving a linear equation. We show that our method can achieve good position prediction accuracy for data with large and accumulating errors on the order of 10 2 pixels, a magnitude that often makes optimization-based algorithms fail to converge. For ptychography instruments without sophisticated position control equipment such as interferometers, our method is of significant practical potential.

47 OTHER INSTRUMENTATION↗

Studies of a proton phase beam monitor for range verification in proton therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and are directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a phase beam monitor can be performed. A first prototype of phase beam monitor was tested at GSI Darmstadt, where measurements of the energy profile of the ion bunches were performed. At the ELBE accelerator Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Oncoray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗