Impact Testing of Heat Source Exemplars

This report details the heat source impact testing performed at the Shock Thermodynamics Applied Research Facility (STAR). The purpose of these tests were to measure the impact behavior of a heated Ta-10W tantalum/tungsten alloy heat source exemplar. Each exemplar resembled a cylinder with a rectangular through-hole orthogonal to the cylinder axis-of-symmetry. In each test, the exemplar was impacted by a hardened steel impactor accelerated using the STAR air gun. The exemplars were impacted perpendicular to the through-hole and at an an angle to the cylindrical axis-of-symmetry. The exemplar bar stock source, impact angle, and impact velocity were varied throughout the testing series. High-speed video was used to measure dynamic impact behavior while photon doppler velocimetry (PDV) and shorting pins were used to measure the impact velocity. Foam support structures were used to thermally isolate the exemplar and provide a support structure which was non-perturbative to the impact event. Soft-catch techniques were used to minimize secondary impacts and enable recovery for detailed post-shot analysis. Results indicate positive correlation between exemplar fracture and the variables of impact velocity and impact angle. Exemplar fracture occurred consistently along a single corner of the through-hole.

36 MATERIALS SCIENCE↗

Evaluation of Thermolytic Hydrogen Generation Rate Models at High-Temperature/High-Hydroxide Regimes

This report describes the results of testing performed to extend the applicable ranges of temperature and hydroxide concentration for use within the Glycolate and Global Total Organic Carbon (TOC) Hydrogen Generation Rate (HGR) expressions. Seven experimental conditions (six simulants of the 242-25H Evaporator system chosen as a D-optimal set of experiments and a single test conducted at an elevated boiling point of 170 °C) were investigated in the presence of sodium glycolate and Xiameter TM AFE-1010. Glycolate was employed to study the extension of the Glycolate Thermolytic HGR expression while Xiameter TM AFE-1010 was employed to study the extension of the Global TOC Thermolytic HGR expression. The following conclusions were derived from this testing: The Glycolate Thermolytic HGR expression may be confidently used to predict thermolytic HGRs from glycolate at temperatures as high as 170 °C and hydroxide concentrations as high as 23 M.; The hydroxide and temperature-dependence predicted by the Global TOC Thermolytic HGR expression has been confirmed at temperatures as high as 170 °C and hydroxide concentrations as high as 23 M, suggesting that the Global TOC Thermolytic HGR expression may be used at these ranges.; Methane was observed from tests with Xiameter TM AFE-1010 at production rates higher than those observed for hydrogen. These rates were observed at temperatures higher than 100 °C.; Preliminary models suggest that increasing hydroxide/temperature causes an increase in Methane Generation Rate (MGR) from Xiameter TM AFE-1010. The following recommendations are based on this testing: The existing equations for thermolytic HGR from glycolate and non-glycolate organics should be used at Concentration, Storage, and Transfer Facilities (CSTF) storage and evaporation conditions, including temperatures and hydroxide concentrations exhibited in the 242-25H Evaporator.; Further investigation should be made into the influence of methylsilanes on CSTF flammability. This investigation should include: determination of the types of methylsilanes historically added to the CSTF, determination of methane formation rates from each type of methylsilane, and determination of the extent of degradation of methylsilanes in CSTF waste.; Characterization techniques should be developed by Savannah River National Laboratory (SRNL) to assist in the speciation of methylsilane-containing waste in the CSTF.; Additional testing with radioactive waste should be performed to determine the MGRs possible in radioactive waste and better inform model predictions made from testing with simulants.

08 HYDROGEN↗

Enhancing Modeling and Simulation for Effective Protection Strategies

This report was created by Sandia National Laboratories (SNL) to document the principles and methodology of performance data collection and integration with modeling and simulation tools to better facilitate the performance evaluation of physical protection systems (PPS). Results and conclusions from the use of modeling and simulation tools are only as good as the data employed by the tools when conducting analysis. Acquiring the performance testing data necessary to ensure effective evaluation can be a complex and sometimes daunting process. It is the desire of the organization to provide guidance that eases the burdens associated with pursuit of these objectives. This document draws heavily upon longstanding principles of systems engineering that have been developed and employed by SNL in the discipline of security since the 1970s. The scope of this document is constrained to the testing of system components and integration of data that is applicable within the context of PPS performance analysis using two tools that have been developed by SNL, PathTrace© and Scribe3D©. For guidance related to testing and evaluation more broadly, the manuals and reports referenced by this document can be consulted.

42 ENGINEERING↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Setups for eliminating static charge of the ATLAS18 strip sensors

Abstract Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration to beable to track charged particles produced at the High-Luminosity LHC, started in 2020 and is expected tocontinue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-psilicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced sensors are measured upon their delivery at several institutes participating in a complex Quality Control (QC) program. The QC tests performed on each individual sensor check the overall integrity and quality of the sensor.During the QC testing of ATLAS18 strip sensors, an increased number of sensors thatfailed the electrical tests was observed. In particular, IV measurements indicated an early breakdown,while large areas containing several tens or hundreds of neighbouring strips with low interstrip isolationwere identified by the Full strip tests, and leakage current instabilities were measured in a long-term leakage current stability setup. Moreover, a high surface electrostatic charge reaching a level of several hundreds of volts per inch was measured on a large number of sensors and on the plastic sheets, whichmechanically protect these sensors in their paper envelopes. Accumulated data indicates a clearcorrelation between observed electrical failures and the sensor charge-up.To mitigate the above-described issues, the QC testing sites significantly modified the sensor handlingprocedures and introduced sensor recovery techniques based on irradiation of the sensor surface with UVlight or application of intensive flows of ionized gas. In this presentation, we will describe the setupsimplemented by the QC testing sites to treat silicon strip sensors affected by static charge andevaluate the effectiveness of these setups in terms of improvement of the sensor performance.

Instruments & Instrumentation↗

Distributed Fiber Optics Measurements of Rock Deformation and Failure in Triaxial Tests

The implementation of distributed strain measurement methods in triaxial and uniaxial tests have demonstrated the development of strain localization, even at early stages. This implies that single point measurement methods are location dependent. The use of distributed methods is required not only to improve the interpreted constitutive parameters obtained from triaxial tests, but also to understand the implications of strain localization in the failure process. Here, this work uses optical fibers in triaxial tests. The developed distributed measurement method was implemented on granite, gabbro, and sandstone samples and tested under different confining pressures, reaching 200 MPa on the granite sample. Using a temporal resolution of 0.25 Hz and 5 mm of spatial resolution, the strain evolution at over 300 locations at the sample surface was measured during testing. When compared to point sensing methods, the use of optical fiber greatly increases the number of measurements at the surface of the sample, and their interpolation provides the entire deformation of the sample surface. In all the tests performed, strain localizations were revealed before failure. A three-dimensional interpretation of a test, combining an optical scan of the sample and the distributed measurements, show good correlation between the fractures and the strain localization.

58 GEOSCIENCES↗

Soil Desiccation Treatability Testing at BC Waste Disposal Cribs

During Hanford’s production period, low-level waste products generated from chemical processing of uranium fuel rods were discharged directly to the ground through a system of cribs and trenches located in the 200-BC-1 Operable Unit (OU). The site consists of 6 cribs and 20 trenches that received more than 117,000 m3 of radioactive liquid waste discharged to the soil. These unlined infiltration galleries held volumes of liquid waste while it seeped into the ground, with the understanding that the 100 m (330 ft) thick vadose zone in the area would effectively capture the effluent and prevent groundwater impacts. A conceptual model showing the operation of cribs and trenches is shown in Figure 1. Data show effluent from the 26 cribs and trenches containing about 410 curies of Technetium-99 (Tc-99) is primarily located between 30 m and 70 m (98 ft and 230 ft) depth (Corbin et al., 2005; Ward et al., 2004). Despite no evidence indicating that the contamination has reached the groundwater at BC cribs and trenches, the mobility of Tc-99 had been demonstrated in laboratory tests and was recognized as a threat to groundwater at the site. Using data from numerical models, laboratory analyses, field investigations, and information on historical discharges, the EPA and Ecology identified Tc-99 and U contamination of the vadose zone as a remediation priority. The U.S. DOE was notified by EPA and Ecology regarding risks associated with Tc-99 contamination in a letter requesting development of a strategy for improved methods to understand the nature and extent of vadose zone contamination, specifically Tc-99, and to develop remedial options for addressing such contamination. To develop the appropriate technology for characterizing, remediating, and monitoring the deep vadose zone Tc-99 contamination, the U.S. DOE worked with the EPA and Ecology to create a Treatability Test Plan under a Remedial Investigation/Feasibility Study (RI/FS) for the Hanford 200 Areas. Under this RI/FS, it was determined that a treatability test for soil desiccation should be carried out as it was identified as a promising in-situ treatment technology for mitigating risks posed by Tc-99 contamination to the groundwater table. The BC Cribs and Trenches site was identified as a representative site for Tc-99 and U contamination and selected for the soil desiccation treatability test. In this chapter, we summarize the overlying regulatory framework of RI/FS and treatability tests and illustrate how development and experimentation supported the evaluation of selected remedies. We briefly discuss the RI/FS for the 200 Areas of the Hanford Site and focus on the soil desiccation treatability testing performed at the BC cribs and trenches site under the Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau (DVZ-TT). The DVZ-TT is one component of the remedial investigation/feasibility study for the Hanford 200 Areas and represents the underlying regulatory framework that drives site operations towards records of decision and site closure.

Mangel, Adam R.↗

Test Report for DPP-1 Regulatory Compliance Testing. Volume 1 - Main Report

Consolidated Nuclear Security, LLC (CNS), the management and operating contractor for the Y-12 National Security Complex (Y-12) for the National Nuclear Security Administration (NNSA), is currently responsible for the regulatory testing of a new Type B fissile material shipping package called the Defense Programs Package (DPP)-1. The DPP-1 is a drum packaging with an inner liner and a removable lid. Both the drum body and the lid are filled with an impact-limiting, thermal-insulating material that protects the inner containment vessel (CV) during normal conditions of transport (NCT) and hypothetical accident conditions (HAC) as defined by 10 US code of Federal Regulations (CFR) 71. In fiscal year 2021, the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP), located at the National Transportation Research Center (NTRC), conducted Type B performance tests as prescribed in Title 10 Code of Federal Regulations Part 71 (10 CFR 71) on seven DPP-1 prototype units. This test report documents test unit (TU) preparation, pretest condition, conditioning of each TU, NCT and HAC testing, and posttest measurements and observations made of the damage resulting from these tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of the CTF subchannel code for modeling a large-break loss-of-coolant accident reflood transient

With increased industry interest in extending reactor operating cycles, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has been investigating the behavior of high-burnup fuel during design basis accidents such as the large-break loss-of-coolant accident (LBLOCA) with consideration for risk of fuel fragmentation, relocation, and dispersal (FFRD). As part of that activity, the NEAMS subchannel thermal/ hydraulics (T/H) code, CTF, is being used for modeling of LBLOCA and to determine the impact of subchannel resolution on results. Although CTF includes a wide range of models for LBLOCA conditions, the code has not been used for this application while maintained at Oak Ridge National Laboratory (ORNL) until now. Therefore, here, in this work, a preliminary assessment of several of these models was performed using openly available reflood experimental data from the Flooding Experiments in Blocked Arrays (FEBA) tests. One coarse mesh and one fine mesh model were set up in CTF for high and low flooding rate tests performed in the unblocked FEBA facility. A coarse TRACE model was set up to be as consistent as possible with the coarse CTF model to allow for code-to-code benchmarking. The assessment shows a tendency of the codes to over-predict peak cladding temperature (PCT) near the top of the bundle and to quench early. Advanced spacer grid models were shown to improve upper bundle predictions in CTF. The resolved CTF model over-predicted PCT by a larger degree in the center channels in the low-flooding rate test, and it is believed that the radiative heat transfer model, which was not used in this study, may be needed to correct this over-prediction. Finally, this work demonstrates the importance of the droplet model in determining quench time and vapor temperature and PCT prediction, which necessitates a more in-depth validation of these models in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improvement of mechanistic fuel-cladding chemical interaction modeling in BISON

This report describes work performed during FY2024 under the auspices of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program to inform and improve mechanistic models of fuel-cladding chemical interaction (FCCI) in metallic fuel. For fuel-side FCCI, atomistic simulations were performed to determine the diffusivity of iron (Fe) in the $\alpha$ and $\gamma$ phases of uranium (U). A model of liquid penetration of cladding due to melting of the fuel-side FCCI region was updated to account for the finite size of the FCCI region, and the model was validated through comparison with tests performed in the Fuel Behavior Test Apparatus (FBTA). For cladding wastage formation, a reduced-order model was improved by comparison with a multi-scale mechanistic model to better quantify the ROM parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of FTWC Vent System

A monitored exhaust system has been designed for use in venting the Flanged Tritium Waste Containers (FTWCs) at LANL. This system will provide controlled exhaust and emissions monitoring for the FTWCs, and also provide general area exhaust around the venting operations to measure any emissions which may bypass the primary vent system. A full description of the process and need for the system is described in the Pre-Construction Application for this project. This document describes the commissioning testing performed on the FTWC vent system to prepare it for use. The system has been tested and shown to meet ANSI standard requirements and is fully suitable for use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methane generation rates from Tank 50 simulant with methylmercury containing saltstone grout solids

This report documents the tests performed to address the requirements listed in the Technical Assistance Request, which resulted in a Test Plan to obtain the required information. To that end the results are documented herein to determine the capacity, and reaction time, for methylmercury (MeHg) contained within Tank 50 salt solution simulant (T50SS) to produce methane when mixed with saltstone dry feed ingredients, as individual components (cement, slag cement, and fly ash) or a combination of those components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-Term PCT of ILAW Glasses (Final Report FY2020)

About 50 million gallons of high-level mixed waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in a near-surface engineered facility – the Integrated Disposal Facility (IDF) – on the Hanford site, while the IHLW product is designed for deep geological disposal in a national facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The objective of the work described in this report is to perform testing, data collection, and analyses for the ILAW glass product for subsequent use in the performance assessment (PA) of the IDF to assess potential environmental risks associated with long-term storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2021 Long-Term PCT of ILAW Glasses

Approximately 54 to 56 million gallons of radioactive waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in a near-surface engineered facility – the Integrated Disposal Facility (IDF) – on the Hanford site, while the IHLW product is designed for deep geological disposal in a national facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The objective of the work described in this report is to perform testing, data collection, and analyses for the ILAW glass product for subsequent use in the performance assessment (PA) of the IDF to assess potential environmental risks associated with long-term storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Testing with Sludge Batch 10 Tank 40 Simulant

Savannah River Mission Completion (SRMC) requested that researchers at Savannah River National Laboratory (SRNL) perform testing designed to examine why the Defense Waste Processing Facility (DWPF) is not collecting elemental mercury in the Mercury Water Wash Tank (MWWT). In order for DWPF to recover mercury, mercuric oxide must first be reduced to elemental mercury. The elemental mercury must then be steam stripped, condense, and coalesce in the Mercury Water Wash Tank (MWWT) during chemical processing in the Sludge Receipt and Adjustment Tank (SRAT). The efficiency of these steps was investigated in a series of laboratory scale SRAT experiments under the nitric-glycolic and nitric-formic flowsheets utilizing Momentive Y-17112 and Antifoam 747. Mercury speciation in the Slurry Mix Evaporator Condensate Tank (SMECT) and condensate streams was also examined. The key conclusions from these experiments are as follows: Mercury II Oxide may not be fully reduced to elemental mercury during acid addition at 93°C. Higher temperatures, i.e., boiling may be necessary to fully reduce Mercury II Oxide. The highest percent mercury recovery (71 %) in the MWWT was observed in the MS-NGA-17112 experiment (nitric-glycolic acid flowsheet with Momentive Y-17112), which is how DWPF is currently operating the SRAT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and Electric Power Research Institute (EPRI) [Abstract]

Carbon dioxide (CO 2 ) capture from flue gas generated by fossil fuel-fired power plants has been proposed as an efficient approach to limit CO 2 emissions to the atmosphere. Due to the high cyclic CO 2 sorption capacity, well-tuned adsorption chemistry and non-volatility, solid sorbents are widely studied for CO 2 capture processes such as pressure swing adsorption (PSA) and temperature swing adsorption (TSA). Realistic applications of traditional solid sorbent systems face many challenges since moisture and heat management are problematic and solid-solid heat exchange is inefficient. Recently, a novel solid sorbent system, the sorbent polymer composite (SPC), has been developed to overcome those challenges in an energy-saving CO 2 capture process using TSA membrane contactors. A SPC material is comprised of a powdered solid sorbent embedded into a hydrophobic and porous polymer matrix. It allows gases to permeate through and achieve full contact with the sorbents while rejecting water moisture in the CO 2 capture process. In this collaborative research, NETL will conduct performance testing of a novel SPC material and EPRI will conduct a cost analysis based on that performance data.

20 FOSSIL-FUELED POWER PLANTS↗

Risk Informed Timelines (RIT) v.1.0

Risk Informed Timelines (RIT) is a more modern and holistic method for understanding how access delay timelines are developed and utilized in physical security system evaluations. The software utilizes Bayesian methods to combine subject matter expert judgement and small performance test datasets in a consistent and defensible way. It allows a more holistic view of delay performance that provides distributions of task times and task success probabilities to account for tasks that, if failed, would result in failure of the attack. The RIT methodology is meant to enable security risk managers to begin the transition into more comprehensive delay timeline analysis. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-8294 O

Noel, ToddG.↗