A Framework for the Relative and Absolute Performance Evaluation of Automated Spectroscopy Systems

The development of high-speed, high-performance gamma-ray spectroscopy algorithms is critical to the success of many automated threat detection systems. In response to this need a proliferation of such algorithms has taken place. With this proliferation comes the necessary and non-trivial task of validation. There is (and always will be) insufficient experimental data to determine performance of spectroscopy algorithms over the relevant factor space at any reasonable precision. In the case of gamma-ray spectroscopy, there are hundreds of radioisotopes of interest, which may come in arbitrary admixtures, there are many materials of unknown quantity, which may be found in the intervening space between the source and the detection system, and there are also irregular variations in the detector systems themselves. All of these factors and more should be explored to determine algorithm/system performance. This paper describes a statistical framework for the performance estimation and comparison of gamma-ray spectroscopy algorithms. The framework relies heavily on data of increasing levels of artificiality to sufficiently cover the factor space. At each level rigorous statistical methods are employed to validate performance estimates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental demonstration and performance evaluation of a complex fenestration system for daylighting and thermal harvesting

Two significant design strategies for mitigating building energy consumption are daylight redirection and solar energy harvesting. Effective daylighting implementation enhances the amount of useful natural light within a space and offsets the need for electric lighting. Solar energy harvesting systems can mitigate energy costs from mechanical systems by managing incoming thermal loads or capturing solar energy that can be used to supplement thermal systems in the building. While there are many available façade-based technologies that can perform daylighting or solar thermal energy harvesting, there remains a limitation in available systems that can perform both of them simultaneously. This paper, describes the design and experimental demonstration of a Liquid Filled Prismatic Louver (LFPL) system, which combines both energy-saving strategies. The LFPL system was installed in a south-facing room in New York City and evaluated for indoor daylight penetration and potential for thermal energy harvesting. Daylight redirection is achieved through the prismatic louver geometry and proper orientation, whereas thermal energy harvesting is achieved through IR absorption from the liquid (e.g., water) within the prisms. Daylighting performance was evaluated by illuminance measurements at key locations within the space, whereas thermal harvesting performance was evaluated through temperature measurements and thermal imaging analysis. We show that the LFPL system, with all prismatic elements oriented at the same angle, achieve a 2-fold and 8-fold enhancement in daylight redirection to the ceiling, for prism orientations of 10° and 20°, respectively. We also demonstrate the system’s capability to adjust to specific lighting needs, within the space, through the dynamic individual orientation of prismatic elements; thus, achieving a concentrated ceiling illuminance enhancement of ~100 times and ~200 times at 2.5 and 4.3 m away from the window sill, providing workplane illuminance enhancement of 6 and 2 times more than in the case of the control room with regular windows. Furthermore, we illustrate a reduction of potential heating loads at locations close to the window from the combination of infrared absorption in the water volume and the redirection of the incoming solar radiation, leading to a reduction of the workplane temperature by an average of 7–10 °C.

14 SOLAR ENERGY↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

Neutronics and Fuel Performance Evaluation of Accident Tolerant Fuel under Normal Operation Conditions

This report details the analysis of neutronics and fuel performance analysis for enhanced accident tolerance fuel, with Monte Carlo reactor physics code Serpent and INL’s fuel performance code BISON, respectively. The purpose is to evaluate two of the most promising candidate materials, FeCrAl and Silicon Carbide (SiC), as the fuel cladding under normal operating conditions. Substantial neutron penalty is identified when FeCrAl is used as monolithic cladding for current oxide fuel. From the reactor physics standpoint, application of the FeCrAl alloy as coating layer on surface of zircaloy cladding is possible without increasing fuel enrichment. Meanwhile, SiC brings extra reactivity and the neutron penalty is of no concern. Application of either FeCrAl or SiC could be favorable from the fuel performance standpoint. Detailed comparison between monolithic cladding and hybrid cladding (cladding + coating) is discussed. Hybrid cladding is more practical based on the economics evaluation during the transition from current UO 2 /zircaloy to Accident Tolerant Fuel (ATF) system. However, a few issues remain to be resolved, such as the creep behavior of FeCrAl, coating spallation, inter diffusion with zirconium, etc. For SiC, its high thermal conductivity, excellent creep resistance, low thermal neutron absorption cross section, irradiation stability (minimal swelling) make it an excellent candidate materials for future nuclear fuel/cladding system.

99 GENERAL AND MISCELLANEOUS↗

Conserving asphalt resources: Rethinking rejuvenator performance evaluation through peptizing efficiency

Timely rejuvenation and restoration of asphalt are essential conservation practices that help preserve and extend the service life of roads, bridges, driveways, and parking lots. The performance of asphalt rejuvenators is often assessed based on their diffusion rates and softening power, yet these metrics alone fail to capture true rejuvenation potential. Here, this study integrates density functional theory (DFT) modeling with experimental analysis to show that rejuvenation effectiveness is primarily governed by molecular interactions with oxidized asphaltene nanoaggregates. DFT results revealed that amide- and unsaturated-chain compounds, such as hexadecanamide, oleic acid, and 9,17-octadecadienal, act cooperatively to disrupt π–π stacking and exfoliate asphaltene layers, reducing binding strength and enhancing dispersion. Unlike bulky, rigid molecules that remain trapped, these components remain mobile and repeatedly interact with multiple aggregation sites. Experimental validation using rheometry and FTIR confirmed that such molecularly compatible rejuvenators restore the binder flexibility and polydispersity, even when diffusion is relatively slow. Building on this mechanistic foundation, six rejuvenators (A2, A5, A7, A8, A9, and A10) were evaluated using a three-metric performance framework encompassing cracking resistance (Glover–Rowe parameter), UV stability, and surface hydrophobicity. Among the six rejuvenators evaluated, A9 exhibited the highest overall performance, reducing the Glover–Rowe cracking parameter by 85% (from 351 kPa to 53 kPa), demonstrating the greatest resistance to UV-induced aging with a stability index of 4.17 h·kPa⁻¹, and increasing surface hydrophobicity to a contact angle of 103.6°. Its superior performance is primarily attributed to its amide- and unsaturated-chain components, which act cooperatively to disrupt π–π stacking interactions and exfoliate asphaltene layers, thereby promoting molecular deagglomeration and enhancing long-term durability. These results shift the criteria for selecting rejuvenators: effective candidates must pair the electronic capability to unlock aged asphaltenes with sufficient structural stability to resist secondary aging and restore hydrophobicity. Restoring hydrophobicity is critical, as aging reduces the asphalt’s water repellency and increases water diffusion, which in turn accelerates moisture-related damage; consequently, a high-performing rejuvenator must effectively restore the binder’s hydrophobic characteristic. Collectively, these findings provide a framework for the rational design of next-generation of bio-based rejuvenators that enhance pavement longevity and promote long-term sustainability.

Aging↗

Performance evaluation of CFRP-rubber shock absorbers

In the present work a numerical investigation on the energy absorbing capability of dedicated structural components made of a carbon fiber reinforced polymer and an emulsion polymerised styrene butadiene rubber is reported. The shock absorbers are devices designed to absorb large amounts of energy by sacrificing their own structural integrity. Their aim is to cushion the effects of an impact phenomenon with the intent to preserve other structures from global failure or local damaging. Another important role of shock absorbers is reducing the peak of the acceleration showed during an impact phenomenon. This effect is of considerable interest in the case of vehicles to preserve passengers’ safety. Static and dynamic numerical results are compared with experimental ones in terms of mean crushing forces, energy and peak crushing. The global performance of the absorbers has been evaluated by referencing to a proposed quality index.

36 MATERIALS SCIENCE↗

CBP Toolbox Version 3.0 “Beta Testing” Performance Evaluation

One function of the Cementitious Barriers Partnership (CBP) is to assess available models of cement degradation and to assemble suitable models into a “Toolbox” that would be made available to members of the partnership, as well as the DOE Complex. To this end, SRNL and Vanderbilt University collaborated to develop an interface using the GoldSim software to the STADIUM @ code developed by SIMCO Technologies, Inc. and LeachXS/ORCHESTRA developed by Energy research Centre of the Netherlands (ECN). Release of Version 3.0 of the CBP Toolbox is planned in the near future. As a part of this release, an increased level of quality assurance for the partner codes and the GoldSim interface has been developed. This report documents results from evaluation testing of the ability of CBP Toolbox 3.0 to perform simulations of concrete degradation applicable to performance assessment of waste disposal facilities. Simulations of the behavior of Savannah River Saltstone Vault 2 and Vault 1/4 concrete subject to sulfate attack and carbonation over a 500- to 1000-year time period were run using a new and upgraded version of the STADIUM @ code and the version of LeachXS/ORCHESTRA released in Version 2.0 of the CBP Toolbox. Running both codes allowed comparison of results from two models which take very different approaches to simulating cement degradation. In addition, simulations of chloride attack on the two concretes were made using the STADIUM @ code. The evaluation sought to demonstrate that: 1) the codes are capable of running extended realistic simulations in a reasonable amount of time; 2) the codes produce “reasonable” results; the code developers have provided validation test results as part of their code QA documentation; and 3) the two codes produce results that are consistent with one another. Results of the evaluation testing showed that the three criteria listed above were met by the CBP partner codes. Therefore, it is concluded that the codes can be used to support performance assessment. This conclusion takes into account the QA documentation produced for the partner codes and for the CBP Toolbox.

97 MATHEMATICS AND COMPUTING↗

SU-C-BRB-04: Characteristics and Performance Evaluation of the First Commercial MLC for a Robotic Delivery System

Purpose: To assess characteristics and performance of the “Incise™” MLC (41 leaf pairs, 2.5mm width, FFF linac) mounted on the robotic SRS/SBRT platform “CyberKnife M6™” in a pre-clinical 5 months (11/2014–03/2015) test period. Methods: Beam properties were measured with unshielded diodes and EBT3 film. The CyberKnife workspace for MLC was analyzed by transforming robot node coordinates (cranial / body paths) into Euler geometry. Bayouth tests for leaf / bank position accuracy were performed in standard (A/P) and clinically relevant non-standard positions, before and after exercising the MLC for 10+ minutes. Total system and delivery accuracy were assessed in End-to-End tests and dosimetric verification of exemplary plans. Stability over time was evaluated in Picket-Fence-and adapted Winston-Lutz-tests (AQA) for different collimator angles. Results: Penumbrae (80–20%, with 100%=2*dose at inflection point; SAD 80cm; 10cm depth) parallel / perpendicular to leaf motion were 2.87/2.64mm for the smallest (0×76×0.75cm{sup 2}) and 5.34/4.94mm for the largest (9.76×9.75cm{sup 2}) square field. MLC circular field penumbrae exceeded fixed cones by 10–20% (e.g. 60mm: 4.0 vs. 3.6mm; 20mm: 3.6 vs. 2.9mm). Interleaf leakage was <0.5%. Clinically accessible workspace with MLC covered (non-coplanar) gantry angles of [-113°;+112°] (cranial) and [-108°;+102°] (body), and collimator angles of [-100°;+107°] (cranial) and [-91°;+100°] (body). Average leaf position offsets were ≤0.2mm in 14 standard A/P Bayouth tests and ≤0.6mm in 8 non-standard direction tests. Pre-test MLC exercise increased jaggedness (range ±0.3mm vs. ±0.5mm) and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.39±0.06mm in 6 End-to-End tests. Picket-Fence and AQA showed no adverse trends during the test period. Conclusion: The Incise™ MLC for CyberKnife M6™ displayed high accuracy and mechanical stability over the test period. The specific CyberKnife geometry and performance after exercise demand dedicated QA measures. This work is in part funded by a research grant from Accuray Inc, Sunnyvale, USA. Erasmus MC Cancer Institute also has research collaborations with Elekta AB, Stockholm, Sweden. C Fuerweger has previously received speaker honoraria from Accuray Inc, Sunnyvale, USA.

60 APPLIED LIFE SCIENCES↗

Formulation and Performance Evaluation of Epoxy Sealant Systems for Double-Shell Tank Bottom Refurbishment

The performance of epoxy sealants used in the refurbishment of double-shell tank (DST) systems requires balancing processability, thermomechanical stability, and adhesion to cementitious substrates. This study incorporates Heloxy 8 as a reactive diluent into Westlake 862 epoxy to tailor workability and cured-state properties. Rheological time-sweep analysis demonstrates that increasing the diluent content significantly reduces complex viscosity and extends workability, thereby improving pumpability and flow for large-area applications. However, the targeted 2-hour processing window is not fully achieved. Differential scanning calorimetry (DSC) confirms that all formulations cure at room temperature to glass transition temperatures ( T g ) at least 20 °C above the maximum DST operating temperature (27 °C), thereby ensuring service in the glassy regime. Dynamic mechanical analysis (DMA) reveals formulation-dependent reductions in tan delta and increases in storage modulus, indicating increasingly elastic and mechanically stable networks with diluent incorporation. Pull-off adhesion testing shows that modified formulations (70–90% Westlake epoxy) exhibit significantly higher adhesion strengths than the unmodified system. Grout cohesive failure indicates that interfacial bonding exceeds substrate strength. Collectively, these results demonstrate that controlled reactive diluent incorporation enables optimization of processing behavior, interfacial adhesion, and thermomechanical performance, supporting the suitability of the modified epoxy systems as durable sealant layers for cementitious barrier applications in hazardous waste containment infrastructure.

Differential scanning calorimetry↗

Thrust stand for vertically oriented electric propulsion performance evaluation

A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A noncontact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivots with oscillatory motion attenuated by a passive, eddy-current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN level thrusts, while those tests conducted on a 200 lbm thruster yielded a resolution of roughly 2.5 mN at thrust levels of 0.5 N and greater.

42 ENGINEERING↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comprehensive assessment of metrology techniques for heliostat efficiency and performance evaluation

Concentrating solar power plants, specifically central receiver type systems and their heliostat field, are struggling with negative reputation in the USA, due to perceived underperformance and reliability issues. This is in part due to a lack of standards for performance assessment as well as overly simplified techno-economical models. A better understanding of influences and losses along the solar radiation path from the sun, across the solar collector to the receiver, increases the fidelity of heliostat efficiency assessment as well as solar field performance predictions. Such data are currently scarce and require a complete set of metrology capabilities to evaluate direct solar irradiance, sun shape, atmospheric attenuation, reflectance, collector shape, slope errors and total beam dispersion. In preparation for establishing a 3rd party metrology platform in collaboration with Sandia National Labs, NLR conducted a scoping study on available metrology. We present an extensive overview of techniques and commercial systems for each category. Our work includes an analysis to increase understanding of strengths and limitations of the many techniques used for surface shape and slope measurement. This applies to a controlled, indoor or outdoor laboratory environment assessing a single heliostat.

14 SOLAR ENERGY↗

PTT System Performance Evaluation in 3-D Imaging of Calibrated Defects: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Research activity in this project is aimed at developing pulsed thermal tomography (PTT) architecture and algorithms for in-service non-destructive examination (NDE) of additively manufactured (AM) reactor components and materials. Recent advances in AM technology could allow cost-efficient fabrication of parts for operating reactors. However, because of stringent safety requirements, long-term performance of AM reactor components needs to be investigated before AM is widely accepted. Because of the complex shapes and significant surface roughness of components due to layer-by-layer welding process in AM, conventional methods might not be useful for in-service NDE of AM components. PTT is ideally suited for in-service NDE of AM metallic components because the method is non-contact, and offers high resolution #-D imaging of material flaws. The objective of this report is to provide initial evaluate of PTT performance sin detecting calibrated flaws in reactor structural materials. Preliminary COMSOL models were developed to conduct super computing simulations of PTT. In the experimental studies, high strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The calibrated defects were created in the form of flat bottom holes (FBH) drilled in metallic plates. The diameters of FBH's varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanic drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. In addition, a 2/3in-thick Inconel 718 nozzle plate produced with additive manufacturing method was imaged with PTT. It was shown that PTT can scan through the plate in approximately 20s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Versatile Simulated Data Transport Layer for in Situ Workflows Performance Evaluation

In situ processing does not only allow scientific applications to face the explosion in data volume and velocity but also to address the time constraints of many simulation-analysis workflows by providing scientists with early insights about their applications at runtime. Multiple frameworks implement the concept of a data transport layer (DTL) to enable such in situ workflows. These tools are very versatile, directly or indirectly access the data generated on the same node, another node of the same compute cluster, or a completely distinct node, and allow data publishers and subscribers to run on the same computing resources or not. This versatility puts on researchers the onus of taking key decisions related to resource allocation and how to transport data to ensure the most efficient execution of their in situ workflows. However, domain scientists and workflow practitioners lack the appropriate tools to assess the respective performance of particular design and deployment options. In this paper we introduce a versatile simulated DTL designed to provide researchers with insights on the respective performance of different execution scenarios of in situ workflows. This open-source, standalone library builds on the SimGrid toolkit and can be linked to any SimGrid-based simulator. It facilitates the evaluation of the performance behavior, at scale, of different data transport configurations and the study of the effects of resource allocation strategies. We demonstrate the scalability, versatility, and accuracy of this simulated DTL by reproducing the execution of two synthetic benchmarks and of a real-world in situ workflow composed of an MPI application and a parallel data analysis. Results of simulations run on a single core show that the proposed library can simulate the interactions of tens of thousands of simulated processes deployed on two interconnected commodity clusters in a few seconds, and the execution by a thousand simulated processes of an in situ workflow in less than three minutes.

Suter, Fred [ORNL] (ORCID:0000000319021955)↗

Performance Evaluation of an Intelligent Sensor Platform for Radiation Monitoring Applications

Accurate, rugged, and reliable radiation detection systems are important for area and environmental monitoring applications. The desire for spectroscopic capability has increased in monitoring aspects of the nuclear fuel cycle to provide fast characterization of the radiation profile of a situation, such as the planned or unplanned release of material. The reduction or elimination of having to conduct sampling for laboratory analysis can result in significant cost savings for an industry, government agency, or regulatory body. A new system, comprised of a NaI:Tl scintillator and a G-M tube, has been designed and tested, taking into account the following end-user requirements: ease-of-use, capability to network and supervise multiple units, compact form factor, low power consumption, versatility, and stability. The detector sizes were selected to accommodate a dose rate up to 1 Sv/hr. Several algorithms and analysis routines have been developed to incorporate these key needs without sacrificing on accuracy, dynamic range, nuclide identification, and sensitivity. This presentation will introduce the major hardware and software components of the platform, as well as the user interface and data analysis workflow. Key features of the hardware include an environmentally robust housing, low power signal processing electronics, patented LED-based gain stabilization, and an embedded processor for unattended instrument management and data analysis. New and improved algorithms for determining scintillator gamma dose rates, total integrated dose, and nuclide identification will be introduced. The two detector elements were modeled with MCNP and validated experimentally. The results of the radiological testing shall be presented including energy resolution, throughput, dose response, and minimum detectable activities. The dose response has been evaluated in simulations and with measurements to ensure accurate response with respect to energy spectrum of the dose field and direction of the incident radiation. Spectroscopy evaluations, such as nuclide detection probability and false alarm rates, were performed and comparisons to existing algorithms shall also be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗