Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Comparative Mirror Cleaning Study: 'A Study on Removing Particulate Contamination'

The cleanliness of optical surfaces is recognized as an industry-wide concern for the performance of optical devices such as mirrors and telescopes, microscopes and lenses, lasers and interferometers, and prisms and optical filters. However, no standard has been established for optical cleaning and there is no standard definition of a 'clean' optical element. This study evaluates the effectiveness of commonly used optical cleaning techniques based on wafer configuration, contamination levels, and the number and size of removed particles. It is concluded that cleaning method and exposure time play a significant factor in obtaining a high removal percentage. The detergent bath and solvent rinse method displayed an increase in effective removal percentage as the contamination exposure increased. Likewise, CO2 snow cleaning showed a relatively consistent cleaning effectiveness. The results can help ensure mission success to flight projects developed for the NASA Origins Program. Advantages and disadvantages of each of the optical cleaning methods are described.

Houston, Karrie↗

Multisensor Instrument for Real-Time Biological Monitoring

The figure schematically depicts an instrumentation system, called a fiber optic-based integration system (FOBIS), that is undergoing development to enable real-time monitoring of fluid cell cultures, bioprocess flows, and the like. The FOBIS design combines a micro flow cytometer (MFC), a microphotometer (MP), and a fluorescence-spectrum- or binding-force-measuring micro-sensor (MS) in a single instrument that is capable of measuring multiple biological parameters simultaneously or sequentially. The fiber-optic-based integration system is so named because the MFC, the MP, and the MS are integrated into a single optical system that is coupled to light sources and photometric equipment via optical fibers. The optical coupling components also include a wavelength-division multiplexer and diffractive optical elements. The FOBIS includes a laserdiode- and fiber-optic-based optical trapping subsystem (optical tweezers ) with microphotometric and micro-sensing capabilities for noninvasive confinement and optical measurement of relevant parameters of a single cell or other particle. Some of the measurement techniques implemented together by the FOBIS have long been used separately to obtain basic understanding of the optical properties of individual cells and other organisms, the optical properties of populations of organisms, and the interrelationships among these properties, physiology of the organisms, and physical processes that govern the media that surround the organisms. For example, flow cytometry yields information on numerical concentrations, cross-sectional areas, and types of cells or other particles. Micro-sensing can be used to measure pH and concentrations of oxygen, carbon dioxide, glucose, metabolites, calcium, and antigens in a cell-culture fluid, thereby providing feedback that can be helpful in improving control over a bioprocess. Microphotometry (including measurements of scattering and fluorescence) can yield further information about optically trapped individual particles. In addition to the multifunctionality not previously available in a single biological monitoring system, the FOBIS offers advantages of low mass, sensitivity, accuracy, portability, low cost, compactness (the overall dimensions of the fully developed FOBIS sensor head are expected to be less than 1 by 1 by 2 cm), and immunity to electromagnetic interference at suboptical frequencies. FOBIS could be useful in a variety of laboratory and field settings in such diverse endeavors as medical, veterinary, and general biological research; medical and veterinary diagnosis monitoring of industrial bioprocesses; and analysis of biological contaminants in air, water, and food.

Zhang, Sean (Zhanxiang)↗

Stratified Diffractive Optic Approach for Creating High Efficiency Gratings

Gratings with high efficiency in a single diffracted order can be realized with both volume holographic and diffractive optical elements. However, each method has limitations that restrict the applications in which they can be used. For example, high efficiency volume holographic gratings require an appropriate combination of thickness and permittivity modulation throughout the bulk of the material. Possible combinations of those two characteristics are limited by properties of currently available materials, thus restricting the range of applications for volume holographic gratings. Efficiency of a diffractive optic grating is dependent on its approximation of an ideal analog profile using discrete features. The size of constituent features and, consequently, the number that can be used within a required grating period restricts the applications in which diffractive optic gratings can be used. These limitations imply that there are applications which cannot be addressed by either technology. In this paper we propose to address a number of applications in this category with a new method of creating high efficiency gratings which we call stratified diffractive optic gratings. In this approach diffractive optic techniques are used to create an optical structure that emulates volume grating behavior. To illustrate the stratified diffractive optic grating concept we consider a specific application, a scanner for a space-based coherent wind lidar, with requirements that would be difficult to meet by either volume holographic or diffractive optic methods. The lidar instrument design specifies a transmissive scanner element with the input beam normally incident and the exiting beam deflected at a fixed angle from the optical axis. The element will be rotated about the optical axis to produce a conical scan pattern. The wavelength of the incident beam is 2.06 microns and the required deflection angle is 30 degrees, implying a grating period of approximately 4 microns. Creating a high efficiency volume grating with these parameters would require a grating thickness that cannot be attained with current photosensitive materials. For a diffractive optic grating, the number of binary steps necessary to produce high efficiency combined with the grating period requires feature sizes and alignment tolerances that are also unattainable with current techniques. Rotation of the grating and integration into a space-based lidar system impose the additional requirements that it be insensitive to polarization orientation, that its mass be minimized and that it be able to withstand launch and space environments.

Chambers, Diana M.↗

HOE/lensless matched spatial filter wavelength-scaling correlator

A scaling correlator optical pattern recognition system is described in which a lensless matched spatial filter (with the second Fourier transform lens and the matched spatial filter recorded on the same plate) is used with a first Fourier transform lens that is also an holographic optical element. The matched spatial filter is recorded at one wavelength and correlation is obtained at a second wavelength. Experimental demonstration and output correlation SNR data are reported, together with a comparison of the system's noise level using conventional optics and holographic elements.

Shen, M.↗

Snapshot multifocal light field microscopy

Light field microscopy (LFM) is an emerging technology for high-speed wide-field 3D imaging by capturing 4D light field of 3D volumes. However, its 3D imaging capability comes at a cost of lateral resolution. In addition, the lateral resolution is not uniform across depth in the light field dconvolution reconstructions. To address these problems, here, we propose a snapshot multifocal light field microscopy (MFLFM) imaging method. The underlying concept of the MFLFM is to collect multiple focal shifted light fields simultaneously. We show that by focal stacking those focal shifted light fields, the depth-of-field (DOF) of the LFM can be further improved but without sacrificing the lateral resolution. Also, if all differently focused light fields are utilized together in the deconvolution, the MFLFM could achieve a high and uniform lateral resolution within a larger DOF. We present a house-built MFLFM system by placing a diffractive optical element at the Fourier plane of a conventional LFM. The optical performance of the MFLFM are analyzed and given. Both simulations and proof-of-principle experimental results are provided to demonstrate the effectiveness and benefits of the MFLFM. We believe that the proposed snapshot MFLFM has potential to enable high-speed and high resolution 3D imaging applications.

He, Kuan↗

Faint-object spectrograph optical bench

The Faint-Object Spectrograph (FOS) is one of five scientific instruments under development for use with the Optical Telescope Assembly (OTA) of NASA's Space Telescope. It is a dual-channel spectrograph operating with two independent 512-channel pulse-counting Digicons. The FOS will be employed in connection with the study of scientific questions associated with quasars, active galaxies, normal distant and local group galaxies, a wide class of objects within the Milky Way Galaxy and neighboring galaxies, and objects within the solar system. The FOS contains an optical bench which supports all optical elements. Dimensional stability was the primary design requirement for the optical bench. This led to the selection of a graphite/epoxy structure using laminates with very low coefficients of thermal expansion and high stiffness. The technical requirements are considered and details of fabrication are discussed.

Toth, J. M., Jr.↗

Solid-state information pattern discriminating switch

A maze-based switch generally having three functional blocks is disclosed. The first functional block handles communications by accepting an entered maze pattern from an external system controller and outputting the entered maze pattern (and optionally its directional complement) to the second functional block. The second functional block stores the maze pattern (and optionally its directional complement) to a permanent storage element and outputs the stored, entered maze pattern and its directional complement to a series of transistors in the third functional block. The third functional block is an electronic maze in which a correct maze pattern and its directional complement must be received by the transistors for the transistors to pass electrical power through the electronic maze to a connected element. The third functional block may alternatively be implemented with optical elements, optoelectronic elements, microelectromechanical elements, or elements formed by other microsystem technologies.

Galambos, Paul C.↗

Optical modeling for dynamics and control analysis

This paper presents a coordinate-free ray-trace analysis of optical beam trains consisting of mirrors, lenses and reference surfaces. The analysis leads to optical models that can be directly integrated with standard structure and control models for integrated instrument design, analysis and simulation. This capability is required for a coming generation of spaceborn optical instruments which use controlled optical elements supported by flexible structures. New results include analytic formulas for optical sensitivities as functions of structural and control geometric parameters. An example problem calculates a linear (small-motion) optical model, derives optical gains for small- and large-angle controlled mirrors, and shows the propagation of a wavefront.

Redding, David C.↗

Novel In-Space Manufacturing Concepts for the Development of Large Space Telescopes

There is a continuous demand for larger, lighter, and higher quality telescopes. Over the past several decades, we have seen the evolution from launchable 2 meter-class telescopes (such as Hubble), to today s demand for deployable 6 meter-class telescopes (such as JWST), to tomorrow s need for up to 150 meter-class telescopes. As the apertures continue to grow, it will become much more difficult and expensive to launch assembled telescope structures. To address this issue, we are seeing the emergence of new novel structural concepts, such as inflatable structures and membrane optics. While these structural concepts do show promise, it is very difficult to achieve and maintain high surface figure quality. Another potential solution to develop large space telescopes is to move the fabrication facility into space and launch the raw materials. In this paper we present initial in-space manufacturing concepts to enable the development of large telescopes. This includes novel approaches for the fabrication of both the optical elements and the telescope support structure. We will also discuss potential optical designs for large space telescopes and describe their relation to the fabrication methods. These concepts are being developed to meet the demanding requirements of DARPA s LASSO (Large Aperture Space Surveillance Optic) program which currently requires a 150 meter optical aperture with a 17 degree field of view.

Mooney, James T.↗

Development of an Optical Slice for an RF and Optical Software Defined Radio

A key component in the Integrated Radio and Optical Communications project at the National Aeronautics and Space Administration's (NASA) Glenn Research Center (GRC) is the radio frequency (RF) and optical software defined radio (SDR). A NASA RF SDR might consist of a general purpose processor to run the Space Telecommunications Radio System (STRS) Architecture for radio command and control, a reconfigurable signal processing device such as a field programmable gate array (FPGA) which houses the waveform, and a digital to analog converter for (DAC) transmitting data. Prior to development, SDR architecture trades on how to combine the RF and optical elements were studied. A modular architecture with physically separate RF and optical hardware slices was chosen and the optical slice of an SDR was designed and developed. The Harris AppSTAR("TM") platform, which consists of an FPGA processing platform with a mezzanine card targeted for RF communications, was used as the base platform in prototyping the optical slice. A serially concatenated pulse position modulation (SCPPM) optical waveform was developed. The waveform follows the standard described in the Consultative Committee for Space Data Systems (CCSDS) Optical Communions Coding and Synchronization Red Book. A custom optical mezzanine printed circuit board card was developed at NASA GRC for optical transmission. The optical mezzanine card replaces the DAC, which is used in the transmission of RF signals. This paper describes RF and optical SDR architecture trades, the Harris AppSTAR("TM") platform, the design of the SCPPM waveform, and the development of the optical mezzanine card.

optical communications↗

Development of an Optical Slice for an RF and Optical Software Defined Radio

A key component in the Integrated Radio and Optical Communications project at the National Aeronautics and Space Administration's (NASA) Glenn Research Center (GRC) is the radio frequency (RF) and optical software defined radio (SDR). A NASA RF SDR might consist of a general purpose processor to run the Space Telecommunications Radio System (STRS) Architecture for radio command and control, a reconfigurable signal processing device such as a field programmable gate array (FPGA) which houses the waveform, and a digital to analog converter (DAC) for transmitting data. Prior to development, SDR architecture trades on how to combine the RF and optical elements were studied. A modular architecture with physically separate RF and optical hardware slices was chosen and the optical slice of an SDR was designed and developed. The Harris AppSTARTM platform, which consists of an FPGA processing platform with a mezzanine card targeted for RF communications, was used as the base platform in prototyping the optical slice. A serially concatenated pulse position modulation (SCPPM) optical waveform was developed. The waveform follows the standard described in the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization Red Book. A custom optical mezzanine printed circuit board card was developed at NASA GRC for optical transmission. The optical mezzanine card replaces the DAC, which is used in the transmission of RF signals. This paper describes RF and optical SDR architecture trades, the Harris AppSTAR platform, the design of the SCPPM waveform, and the development of the optical mezzanine card.

Nappier, Jennifer M.↗

Thermal and Mechanical Stability of the WF/PC II Optical Alignment

The Wide Field/Planetary Camera (WF/PC), developed by the Jet Propulsion Laboratory (JPL) under contract to the National Aeronautics and Space Administration (NASA), is the principal science instrument on the Hubble Space Telescope (HST). The analytical predicted motion of the WF/PC II optical elements showed that the four mechanisms added to the WF/PC II optical train will be able to maintain instrument alignment through the entire range of environmental changes from alignment on earth to operation in space.

Wide↗

Contamination, Transportation or Transmutation in LENR Material Analyses

LENR experiments using various loading and triggering mechanisms rely on a variety of elemental and isotopic assays to determine LENR effects. These assays include optical microscopy, Scanning Electron Microscopy with Energy Dispersive X-Ray Analysis (SEM/EDX), X-Ray Photoelectron Spectroscopy (XPS) and Transmission Electron Microscopy (TEM). All of these methods observe the surface of a material. By dissolving or vaporizing the sample, Inductively Coupled Plasma Optical Element Spectroscopy (ICP-OES) can determine elemental composition (ppb) or with mass spectroscopy, isotopes (ICP/MS). One can use a focused ion beam (FIB) to cut open a sample and observe the “cut” with either SEM/EDX, or Time-of-Flight Secondary Ion Mass Spectroscopy (TOF-SIMS). High Purity Gamma Ray Spectroscopy (HPGe) and alpha/ beta Liquid Scintillator spectroscopy can be used. We’ve employed these assay methods in our NASA GRC research under both the Advanced Energy Conversion and Lattice Confinement Fusion Projects. However, there are limitations associated with each of these methods ranging from handling contamination, instrumental limitations including sensitivity and field of view, and sample preparation.

Low Energy Nuclear Reactions↗

Optical contacting for gravity probe star tracker

A star-tracker telescope, constructed entirely of fused silica elements optically contacted together, has been proposed to provide submilliarc-second pointing accuracy for Gravity Probe. A bibliography and discussion on optical contacting (the bonding of very flat, highly polished surfaces without the use of adhesives) are presented. Then results from preliminary experiments on the strength of optical contacts including a tensile strength test in liquid helium are discussed. Suggestions are made for further study to verify an optical contacting method for the Gravity Probe star-tracker telescope.

Wright, J. J.↗

Laser diode lensless MSF-HOE correlator

Description of an optical pattern recognition system employing a laser-diode lensless MSF correlator based on the use of holographic optical elements (HOE). The system has size, cost, and weight advantages over conventional optical processors, and it is believed to be the first unification of MSF correlation, laser diode, and HOE technologies.

Caimi, F.↗

Hubble Space Telescope - First Servicing Mission

Space Shuttle mission STS-61 was the first of several planned servicing missions for HST, intended to periodically replace failed components and upgrade scientific instruments with improved versions to keep the telescope viable and productive throughout its planned 15-year lifetime. This First Servicing Mission was also intended to correct several design flaws that were detected shortly after the launch of HST. There were three overall mission objectives for the STS-61 repair mission: 1) To Restore the Planned Scientific Capabilities: One complexity of the First Servicing Mission was the necessity for adding optical elements in the light path to correct the spherical aberration. These corrective optics were required to provide the quantitative science capability to enable key scientific programs to be carried out as originally planned. The addition of the COSTAR and the installation of WFPC2 both contributed to recovering these capabilities. 2) To Restore the Reliability of Vehicle Systems: Failed or degraded components had depleted some of the original subsystem redundancy, which had to be restored to allow continued science operations until the next servicing mission in 1997. Anomalous components that required servicing included the solar arrays, gyroscope sensing units, gyroscope electronics, magnetometers, solar array drive electronics, and electrical fuses. 3) To Validate the On-Orbit Servicing Concept for HST: Validation of the concept of on-orbit servicing as the way to achieve HST's full 15-year life was required to provide a foundation for future servicing missions.

Source record↗

Integrated Radio and Optical Communications (iROC) Primary, Secondary, and Tertiary Optics Alignment Procedure

This Technical Memorandum (TM) describes a procedure and associated equipment for performing an initial, relative alignment of a multiple-element optical system. The specific system of interest motivating this procedure arises from the Integrated Radio and Optical Communications (iROC) project, but is applicable to the more general configuration of a two-element folded, reflective telescope. Each step of the procedure includes a description of the particular degree of freedom (DOF) being addressed, and the associated equipment required, including both commercially available items and those fabricated specifically for this purpose.

Paul S Greenberg↗

Secondary and compound concentrators for parabolic dish solar thermal power systems

A secondary optical element may be added to a parabolic dish solar concentrator to increase the geometric concentration ratio attainable at a given intercept factor. This secondary may be a Fresnel lens or a mirror, such as a compound elliptic concentrator or a hyperbolic trumpet. At a fixed intercept factor, higher overall geometric concentration may be obtainable with a long focal length primary and a suitable secondary matched to it. Use of a secondary to increase the geometric concentration ratio is more likely to e worthwhile if the receiver temperature is high and if errors in the primary are large. Folding the optical path with a secondary may reduce cost by locating the receiver and power conversion equipment closer to the ground and by eliminating the heavy structure needed to support this equipment at the primary focus. Promising folded-path configurations include the Ritchey-Chretien and perhaps some three element geometries. Folding the optical path may be most useful in systems that provide process heat.

Jaffe, L. D.↗