Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noise exposure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Using VAPEPS for noise control on Space Station Freedom

Noise environmental control is an important design consideration for Space Station Freedom (SSF), both for crew safety and productivity. Acoustic noise requirements are established to eliminate fatigue and potential hearing loss by crew members from long-term exposure and to facilitate speech communication. VAPEPS (VibroAcoustic Payload Environment Prediction System) is currently being applied to SSF for prediction of the on-orbit noise and vibration environments induced in the 50 to 10,000 Hz frequency range. Various sources such as fans, pumps, centrifuges, exercise equipment, and other mechanical devices are used in the analysis. The predictions will be used in design tradeoff studies and to provide confidence that requirements will be met. Preliminary predictions show that the required levels will be exceeded unless substantial noise control measures are incorporated in the SSF design. Predicted levels for an SSF design without acoustic control treatments exceed requirements by 25 dB in some one-third octave frequency bands.

Badilla, Gloria↗

Helicopter Flight Procedures for Community Noise Reduction

A computationally efficient, semiempirical noise model suitable for maneuvering flight noise prediction is used to evaluate the community noise impact of practical variations on several helicopter flight procedures typical of normal operations. Turns, "quick-stops," approaches, climbs, and combinations of these maneuvers are assessed. Relatively small variations in flight procedures are shown to cause significant changes to Sound Exposure Levels over a wide area. Guidelines are developed for helicopter pilots intended to provide effective strategies for reducing the negative effects of helicopter noise on the community. Finally, direct optimization of flight trajectories is conducted to identify low noise optimal flight procedures and quantify the magnitude of community noise reductions that can be obtained through tailored helicopter flight procedures. Physically realizable optimal turns and approaches are identified that achieve global noise reductions of as much as 10 dBA Sound Exposure Level.

Greenwood, Eric↗

Mach Cutoff Analysis and Results from NASA's Farfield Investigation of No-Boom Thresholds

In support of the ongoing effort by the National Aeronautics and Space Administration (NASA) to bring supersonic commercial travel to the public, the NASA Armstrong Flight Research Center and the NASA Langley Research Center, in partnership with other industry organizations and academia, conducted a flight research experiment to analyze acoustic propagation in the Mach cutoff shadow zone. The effort was conducted in the fall of 2012 and named the Farfield Investigation of No-boom Thresholds (FaINT). The test helped to build a dataset that will go toward further understanding of the unique acoustic propagation characteristics below Mach cutoff altitude. FaINT was able to correlate sonic boom noise levels measured below cutoff altitude with precise airplane flight conditions, potentially increasing the accuracy over previous studies. A NASA F-18B airplane made supersonic passes such that its Mach cutoff caustic would be at varying distances above a linear 60-microphone, 7375-ft (2247.9 m) long array. A TG-14 motor glider equipped with a microphone on its wing-tip also attempted to capture the same sonic boom waves above ground, but below the Mach cutoff altitude. This paper identified an appropriate metric for sonic boom waveforms in the Mach cutoff shadow zone called Perceived Sound Exposure Level; derived an empirical relationship between Mach cutoff flight conditions and noise levels in the shadow zone; validated a safe cutoff altitude theory presented by previous studies; analyzed the sensitivity of flight below Mach cutoff to unsteady atmospheric conditions and realistic aircraft perturbations; and demonstrated the ability to record sonic boom measurements over 5000 ft (1524.0 m) above ground level, but below Mach cutoff altitude.

flight research↗

The Interstellar Mapping And Acceleration Probe High Energy (IMAP-Hi) Neutral Atom Imager

The IMAP-Hi Energetic Neutral Atom (ENA) Imager on NASA’s Interstellar Mapping and Acceleration Probe (IMAP) mission (McComas et al. 2018a, 2025) is designed to measure ENAs from the global interaction between the heliosphere and the local interstellar medium (LISM). These ENAs are initially plasma ions of solar wind origin that are neutralized by charge exchange with the cold neutral atoms of LISM that freely flow through the heliosphere-LISM interaction region. IMAP-Hi consists of two identical single-pixel sensors, each covering the ENA spectral range from 0.44 keV to 15.6 keV over nine contiguous energy passbands and having an approximately conical field-of-view (FOV) of 4.1o full width at half maximum (FWHM). The Hi-45 sensor points 45o relative to the spacecraft spin axis from the antisunward direction; each spacecraft spin, it measures ENA intensity over a circular swath with half-cone angle 45o centered on the ecliptic plane. The Hi-90 sensor points 90o relative to the spin axis; each spacecraft spin, it measures ENA intensity over a great circle in the sky, sampling both the north and south ecliptic poles. As the IMAP spin vector is re-pointed daily toward the Sun, the ecliptic longitude of the swaths moves daily by ∼1o such that a full sky map is acquired by Hi-90 every six months and a complete low latitude (−45o to +45o) map is acquired by Hi-45 annually. The IMAP-Hi sensor design has direct heritage from the IBEX-Hi imager on the Interstellar Boundary Explorer (IBEX) mission, with substantial improvements in energy range, energy resolution, angular resolution, signal-to-noise ratio, and, for ecliptic latitudes within ±45o, temporal resolution and exposure time. The global ENA maps acquired by IMAP-Hi partially overlap in energy and viewing with the ENA maps acquired by the IMAP-Lo and IMAP-Ultra ENA imagers, which we combine to answer fundamental questions about the structure and dynamics of the interaction of the heliosphere and the LISM.

79 ASTRONOMY AND ASTROPHYSICS↗

Saturn's rings - Azimuthal variations, phase curves, and radial profiles in four colors

Four-color photographic photometry, at effective wavelengths of 5900, 5350, 4150, and 3560 A, obtained during the 1977, 1978, and 1979 Saturn apparitions, were analyzed to determine the ring brightness as a function of wavelength, solar phase angle, ring particle orbital phase (the azimuthal effect), declination of the earth relative to the ring plane (tilt effect), and radial distance from Saturn. Data were obtained using the International Planetary Patrol network when the ring tilt angle B was approximately 16.5, 11.5, and 6 deg, respectively. From the approximately 40,000 original images, 364 were scanned and digitized, along with corresponding calibration exposures. The smearing correction technique used achieved better signal-to-noise by utilizing such constraints as the known width of Cassini's Division on the major axis. The most important observational results were summarized, and included the following: the azimuthal brightness variations for the brighter portion of ring A increased as the ring tilt decreased from B = 26 deg to less than 16 deg, reaching the order of + or 20% with respect to the ansae; they are not detectable for ring B or the outer portion of ring A.

Thompson, W. T.↗

Inner coma imaging of Comet Levy (1990c) with the Hubble Space Telescope

Observations of comet Levy were carried out with the Hubble Space Telescope (HST) on UT 27 Sep. 1990. The comet was imaged with the Wide Field Camera (WFC) through both red and blue filters, which were selected to isolate continuum emission peaking sharply at the nucleus. The longest exposures (4 sec) through the red filter had sufficient signal to noise that image deconvolution could be used to recover virtually the full spatial resolution of HST. These images reveal a fan-shaped inner coma in which the sunward-facing hemisphere is significantly brighter than the tailward hemisphere, consistent with volatile sublimation occurring primarily on the dayside of the nucleus.

Weaver, Harold A.↗

2014 SRP Integration Transcript

HRP's mission is to reduce the risks to human health and performance during long-duration spaceflight. The HRP Integrated Research Plan (IRP) contains the research plans for the 32 risks that require research to characterize and mitigate. From its inception the "integrate" aspect of the IRP has denoted the integrated nature of risks to human health and performance. Even though each risk in the IRP has its own research plan and is tracked separately, the interrelated nature of health and performance requires that they be addressed in an integrative or holistic fashion so that the connectedness of physiological systems within the human body and the integrated response to spaceflight can be addressed. Common characteristics of the spaceflight environment include altered gravity, atmospheres, and light/dark cycles; space radiation; isolation; noise; and periods of high or low workload. Long-term exposure to this unique environment produces a suite of physiological effects such as stress; vision, neurocognitive, and anthropometric changes; circadian misalignment; fluid shifts; cardiovascular deconditioning; immune dysregulation; and altered nutritional requirements. Expanding cross-disciplinary integrative approaches that synthesize concepts or data from two or more disciplines would improve the identification and characterization risk factors, and enable the development of countermeasures relevant to multiple risks. Cross-disciplinary approaches might also help to illuminate problem areas that may arise when a countermeasure adversely impacts risks other than those which it was developed to mitigate, or to identify groupings of physiological changes that are likely to occur that may impact the overall risk posture. In 2014 HRP embarked on a pilot study that combined four SRPs (and 12 HRP risks) - Behavioral Health, Sensorimotor, Cardiovascular, and Bone/Muscle - specifically to discuss cross-disciplinary integration. The points outlined below were suggested to seed the discussion, within the bounding constraint that research plans must be feasible and relevant to the HRP mission. While these were suggested starting points, the overall guiding principle was to allow free discussion from panel members on any aspect of integrated research that they felt was important, Existing cross-disciplinary integration as documented in the IRP (HRR), Existing or needed integration already identified by HRP, but not yet well defined within the IRP, Areas of integration that are missing.

Steinberg, Susan↗

The vulnerability of commercial aircraft avionics to carbon fibers

Avionics components commonly used in commercial aircraft were tested for vulnerability to failure when operated in an environment with a high density of graphite fibers. The components were subjected to a series of exposures to graphite fibers of different lengths. Lengths used for the tests were (in order) 1 mm, 3 mm, and 10 mm. The test procedure included subjecting the equipment to characteristic noise and shock environments. Most of the equipment was invulnerable or did not fail until extremely high average exposures were reached. The single exception was an air traffic control transponder produced in the early 1960's. It had the largest case open area through which fibers could enter and it had no coated boards.

Meyers, J. A.↗

Vibration-based health characterization of multiple IMUs in UAV applications

Inertial measurement units (IMUs) are vital in UAV navigation for vehicle attitude and position estimation, especially in the frequently-occurring case of temporary loss of GPS capabilities. Degradation in these units could yield inaccurate position estimates, resulting in incorrect input for vehicle control systems. A wide variety of these units exist to meet the needs of UAV operators, general aviation, and military vehicles. In recent decades, lightweight and inexpensive MEMS sensors have grown in popularity with respect to UAVs. Studies into the failure modes of MEMS devices suggest that vibration is one of the leading causes of MEMS degradation. MEMS sensors are generally encased in their own hermetic packaging, as their small size and sensitivity cause them to be particularly vulnerable to air damping and particulate contamination when exposed. Exposure to excessive vibration can cause cracking in this packaging as well as damage to connecting electronics, with recorded results that cause sensors to act outside of their specifications, potentially providing unreliable input to controllers. A prior study from the Politecnico di Torino looked into the degradation of MEMS IMUs, specifically the AXIS-AIS402, for aerospace and vibrating environments. In the study, the authors found that after exposing MEMS IMUs to simulated vibrations from working conditions of aerospace applications, the sensors showed increased noise and increased bias instability. At NASA Ames, several widely-used MEMS IMUs were selected for a new IMU degradation study, comparing accelerometer performance before and after exposure to similar levels of vibration simulating aerospace conditions. The IMUs were selected from the Pixhawk autopilot systems, hobby sUAS, or prior experimental studies at NASA. Additionally, the industrial grade VectorNav-100 IMU was selected as a ground truth reference point to which the performance of the test sensors can be compared. In the study, each sensor is exposed to functional levels of UAV vibration as replicated on a single-frequency vibratory table in the NASA Ames SHARP Laboratory, and each accelerometer is characterized for bias, drift, and noise characteristics both before and after vibratory exposure. The focus of this study is to monitor the health of the IMU sensors and determine if sensor degradation can be detected from output error and frequency spectrum analysis, rather than from microscopic examination of the sensors. In this case, sensor degradation and faulty data can be more easily detectable by non-experts hoping to use these sensors as an important piece of an integrated package. In addition, specific sensor degradation modes potentially leading to in-flight hazards could be identified, such as accelerated levels of drift and altered temperature response. The overall goal of this work is to increase levels of safety for future users of these sensors and to provide a clear analysis of sensor limitations currently lacking in most sensor specification documentation.

IMUs↗

SDSS-IV MaNGA: a catalogue of spectroscopically detected strong galaxy–galaxy lens candidates

ABSTRACT We spectroscopically detected candidate emission-lines of 8 likely, 17 probable, and 69 possible strong galaxy–galaxy gravitational lens candidates found within the spectra of $\approx 10\, 000$ galaxy targets contained within the completed Mapping of Nearby Galaxies at Apache Point Observatory survey. This search is based upon the methodology of the Spectroscopic Identification of Lensing Objects project, which extends the spectroscopic detection methods of the BOSS Emission-Line Lensing Survey and the Sloan Lens ACS Survey. We scanned the co-added residuals that we constructed from stacks of foreground subtracted row-stacked-spectra so a sigma-clipping method can be used to reject cosmic rays and other forms of transients that impact only a small fraction of the combined exposures. We also constructed narrow-band images from the signal to noise of the co-added residuals to observe signs of lensed source images. We also use several methods to compute the probable strong lensing regime for each candidate lens to determine which candidate background galaxies may reside sufficiently near the galaxy centre for strong lensing to occur. We present the spectroscopic redshifts within a value-added catalogue (VAC) for data release 17 (DR17) of SDSS-IV. We also present the lens candidates, spectroscopic data, and narrow-band images within a VAC for DR17. High resolution follow-up imaging of these lens candidates are expected to yield a sample of confirmed grade-A lenses with sufficient angular size to probe possible discrepancies between the mass derived from a best-fitting lens model, and the dynamical mass derived from the observed stellar velocities.

79 ASTRONOMY AND ASTROPHYSICS↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

Stress, temperature, heart rate, and hibernating factors in hamsters

Pathophysiological conditions resulting from prolonged exposure to zero gravity, cabin constraint, altered ambient environment, whether it be noise, vibrations, high temperatures, or combinations of such factors, are studied in laboratory animals and applied to manned space flight. Results and plans for further study are presented. Specific topics covered include: thermoregulation and its role in reflecting stress and adaptation to the gravity free environment and cabin confinement with its altered circadian forcings; renal function and its measurement in electrolyte distribution and blood flow dynamics; gastronintestinal function and an assessment of altered absorptive capacity in the intestinal mucosa; and catecholamine metabolism in terms of distribution and turnover rates in specific tissues.

Musacchia, X. J.↗

Method for extracting long-equivalent wavelength interferometric information

A process for extracting long-equivalent wavelength interferometric information from a two-wavelength polychromatic or achromatic interferometer. The process comprises the steps of simultaneously recording a non-linear sum of two different frequency visible light interferograms on a high resolution film and then placing the developed film in an optical train for Fourier transformation, low pass spatial filtering and inverse transformation of the film image to produce low spatial frequency fringes corresponding to a long-equivalent wavelength interferogram. The recorded non-linear sum irradiance derived from the two-wavelength interferometer is obtained by controlling the exposure so that the average interferogram irradiance is set at either the noise level threshold or the saturation level threshold of the film.

Hochberg, Eric B.↗

Quieting a noisy antenna reproduces photosynthetic light-harvesting spectra

Photosynthesis achieves near unity light-harvesting quantum efficiency yet it remains unknown whether there exists a fundamental organizing principle giving rise to robust light harvesting in the presence of dynamic light conditions and noisy physiological environments. Here, we present a noise-canceling network model that relates noisy physiological conditions, power conversion efficiency, and the resulting absorption spectra of photosynthetic organisms. Using light conditions in full solar exposure, light filtered by oxygenic phototrophs, and light filtered under seawater, we derived optimal absorption characteristics for efficient solar power conversion. We show how light-harvesting antennae can be tuned to maximize power conversion efficiency by minimizing excitation noise, thus providing a unified theoretical basis for the observed wavelength dependence of absorption in green plants, purple bacteria, and green sulfur bacteria.

Science & Technology - Other Topics↗

Detector noise statistics in the non-linear regime

The statistical behavior of an idealized linear detector in the presence of threshold and saturation levels is examined. It is assumed that the noise is governed by the statistical fluctuations in the number of photons emitted by the source during an exposure. Since physical detectors cannot have infinite dynamic range, our model illustrates that all devices have non-linear regimes, particularly at high count rates. The primary effect is a decrease in the statistical variance about the mean signal due to a portion of the expected noise distribution being removed via clipping. Higher order statistical moments are also examined, in particular, skewness and kurtosis. In principle, the expected distortion in the detector noise characteristics can be calibrated using flatfield observations with count rates matched to the observations. For this purpose, some basic statistical methods that utilize Fourier analysis techniques are described.

Shopbell, P. L.↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗

Multifrequency spectra of BL Lac objects

A program to obtain simultaneous multifrequency spectra of BL Lacertae objects that are known X-ray sources is discussed. The IUE spectra are generally featureless and well-fitted by power law models. For the faintest exposures, Gaussian extraction of the spectrum can greatly impove the signal-to-noise. Most program objects vary in the ultraviolet, although the time scales are not known because of limited observing time. The broadband spectra of BL Lacs exhibit a range of characteristics but the curvature is always downward and the shape is generally smooth. This can be interpreted as synchrotron emission from a relativistic jet; different jet models are possible, and each allows a range of values for the bulk velocity, magnetic field strength, and electron density. Synchrotron models are not required, however an accretion disk model also gives a good fit to the ultraviolet-through-X-ray continuum.

Urry, C. M.↗