Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple views”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Morphological traits for allometric scaling of the European Sea Bass Dicentrarchus labrax (Linnaeus, 1758) from Southern Portugal population

Abstract The present study aimed to determine the allometric scaling among a selection of morphological traits in European sea bass ( Dicentrarchus labrax ) to estimate fish body weight. A set of morphological traits (fish body weight, length, height, and width) were directly measured in 146 fish of a recirculating aquaculture system, with body weights ranging from 17.11 to 652.21 g. In addition, a collection of digital imagery of each anesthetized fish from the side and top views were used to estimate other traits (indirect measures). Multiple regression analysis and regression coefficients were calculated using all possible combinations of biometric data (predictors) to estimate fish body weight, applying different numerical fitting models (linear, log‐linear, quadratic, exponential). The results showed that the best combination of traits for estimating fish body weight were fish body width, length and height, collected from direct measure ( R 2 = 0.995), for a log‐linear model fitting, which revealed more accurate determinations than the most commonly used length–weight relationship. Nevertheless, other combinations of morphological traits and fitting models were also found to be suitable in successfully predict fish body weight, with variability ranging between 92.5% and 98.5%. For indirect measures, the best predictor was a combination of traits from top view (width, eye distance and area without fins) fitted with a log‐linear function. These results comprise a relevant baseline in supporting the high potential of noninvasive methods to accurately follow the growth of European sea bass juveniles, recurring to imagery analysis of anesthetized fish. It has major potential applications in feeding consumption trials and fish growth models, as it allows for continuously following up fish growth under different experimental conditions without therein distress derived from manipulation.

Azevedo, Ana↗

Eliminate angular color shift in top‐emitting OLEDs through cavity design

Abstract OLEDs suffer from viewing angle dependent spectral shift due to microcavity effects. To address this issue, we introduce a novel top‐emitting OLED with a dielectric spacer that forms multiple cavity modes. The resulting device shows almost no color shift at different viewing angles.

Dong, Chen↗

ON THE FORMATION OF MULTIPLE STELLAR POPULATIONS IN GLOBULAR CLUSTERS

Nearly all globular clusters (GCs) studied to date show evidence for multiple stellar populations, in stark contrast to the conventional view that GCs are a mono-metallic, coeval population of stars. This generic feature must therefore emerge naturally within massive star cluster formation. Building on earlier work, we propose a simple physical model for the early evolution (several 10{sup 8} yr) of GCs. We consider the effects of stellar mass loss, Type II supernovae (SNe II) and prompt Type Ia supernovae (SNe Ia), ram pressure, and accretion from the ambient interstellar medium (ISM) on the development of a young GC's own gas reservoir. In our model, SNe II from a first generation of star formation clears the GC of its initial gas reservoir. Over the next several 10{sup 8} yr, mass lost from asymptotic giant branch stars and matter accreted from the ambient ISM collect at the center of the GC. This material must remain quite cool (T {approx} 10{sup 2} K), but does not catastrophically cool on a crossing time because of the high Lyman-Werner flux density in young GCs. The collection of gas within the GC must compete with ram pressure from the ambient ISM. After several 10{sup 8} yr, the Lyman-Werner photon flux density drops by more than three orders of magnitude, allowing molecular hydrogen and then stars to form. After this second generation of star formation, SNe II from the second generation and then prompt SNe Ia associated with the first generation maintain a gas-free GC, thereby ending the cycle of star formation events. Our model makes clear predictions for the presence or absence of multiple stellar populations within GCs as a function of GC mass and formation environment. While providing a natural explanation for the approximately equal number of first- and second-generation stars in GCs, substantial accretion from the ambient ISM may produce fewer chemically peculiar second-generation stars than are observed. Analyzing intermediate-age LMC clusters, we find for the first time evidence for a mass threshold of {approx}10{sup 4} M{sub sun} below which LMC clusters appear to be truly coeval. This threshold mass is consistent with our predictions for the mass at which ram pressure is capable of clearing gas from clusters in the LMC at the present epoch. Recently, claims have been made that multiple populations within GCs require that GCs form at the center of their own dark matter halos. We argue that such a scenario is implausible. Observations of the young and intermediate-age clusters in the LMC and M31 will provide strong constraints on our proposed scenario.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-C-206-07: A Practical Sparse View Ultra-Low Dose CT Acquisition Scheme for PET Attenuation Correction in the Extended Scan Field-Of-View

Purpose: To further reduce CT dose, a practical sparse-view acquisition scheme is proposed to provide the same attenuation estimation as higher dose for PET imaging in the extended scan field-of-view. Methods: CT scans are often used for PET attenuation correction and can be acquired at very low CT radiation dose. Low dose techniques often employ low tube voltage/current accompanied with a smooth filter before backprojection to reduce CT image noise. These techniques can introduce bias in the conversion from HU to attenuation values, especially in the extended CT scan field-of-view (FOV). In this work, we propose an ultra-low dose CT technique for PET attenuation correction based on sparse-view acquisition. That is, instead of an acquisition of full amount of views, only a fraction of views are acquired. We tested this technique on a 64-slice GE CT scanner using multiple phantoms. CT scan FOV truncation completion was performed based on the published water-cylinder extrapolation algorithm. A number of continuous views per rotation: 984 (full), 246, 123, 82 and 62 have been tested, corresponding to a CT dose reduction of none, 4x, 8x, 12x and 16x. We also simulated sparse-view acquisition by skipping views from the fully-acquired view data. Results: FBP reconstruction with Q. AC filter on reduced views in the full extended scan field-of-view possesses similar image quality to the reconstruction on acquired full view data. The results showed a further potential for dose reduction compared to the full acquisition, without sacrificing any significant attenuation support to the PET. Conclusion: With the proposed sparse-view method, one can potential achieve at least 2x more CT dose reduction compared to the current Ultra-Low Dose (ULD) PET/CT protocol. A pre-scan based dose modulation scheme can be combined with the above sparse-view approaches, which can even further reduce the CT scan dose during a PET/CT exam.

60 APPLIED LIFE SCIENCES↗

TGCat : THE CHANDRA TRANSMISSION GRATING DATA CATALOG AND ARCHIVE

The Chandra Transmission Grating Data Archive and Catalog (TGCat) provides easy access to analysis-ready products, specifically, high-resolution X-ray count spectra and their corresponding calibrations. The web interface makes it easy to find observations of a particular object, type of object, or type of observation; to quickly assess the quality and potential usefulness of the spectra from pre-computed summary plots; or to customize a view with an interactive plotter, optionally combining spectra over multiple orders or observations. Data and responses can be downloaded as a package or as individual files, and the query results themselves can be retrieved as ASCII or Virtual Observatory tables. Portable reprocessing scripts used to create the archive and which use the Chandra X-ray Center's (CXC's) software and other publicly available software are also available, facilitating standard or customized reprocessing from Level 1 CXC archival data to spectra and responses with minimal user interaction.

79 ASTRONOMY AND ASTROPHYSICS↗

SigTime: Learning and Visually Explaining Time Series Signatures

Understanding and distinguishing temporal patterns in time series data is essential for scientific discovery and decision-making. For example, in biomedical research, uncovering meaningful patterns in physiological signals can improve diagnosis, risk assessment, and patient outcomes. However, existing methods for time series pattern discovery face major challenges, including high computational complexity, limited interpretability, and difficulty in capturing meaningful temporal structures. Here, to address these gaps, we introduce a novel learning framework that jointly trains two Transformer models using complementary time series representations: shapelet-based representations to capture localized temporal structures and traditional feature engineering to encode statistical properties. The learned shapelets serve as interpretable signatures that differentiate time series across classification labels. Additionally, we develop a visual analytics system—SigTime—with coordinated views to facilitate exploration of time series signatures from multiple perspectives, aiding in useful insights generation. We quantitatively evaluate our learning framework on eight publicly available datasets and one proprietary clinical dataset. Additionally, we demonstrate the effectiveness of our system through two usage scenarios along with the domain experts: one involving public ECG data and the other focused on preterm labor analysis.

97 MATHEMATICS AND COMPUTING↗

TU-H-206-04: An Effective Homomorphic Unsharp Mask Filtering Method to Correct Intensity Inhomogeneity in Daily Treatment MR Images

Purpose: The daily treatment MRIs acquired on MR-IGRT systems, like diagnostic MRIs, suffer from intensity inhomogeneity issue, associated with B1 and B0 inhomogeneities. An improved homomorphic unsharp mask (HUM) filtering method, automatic and robust body segmentation, and imaging field-of-view (FOV) detection methods were developed to compute the multiplicative slow-varying correction field and correct the intensity inhomogeneity. The goal is to improve and normalize the voxel intensity so that the images could be processed more accurately by quantitative methods (e.g., segmentation and registration) that require consistent image voxel intensity values. Methods: HUM methods have been widely used for years. A body mask is required, otherwise the body surface in the corrected image would be incorrectly bright due to the sudden intensity transition at the body surface. In this study, we developed an improved HUM-based correction method that includes three main components: 1) Robust body segmentation on the normalized image gradient map, 2) Robust FOV detection (needed for body segmentation) using region growing and morphologic filters, and 3) An effective implementation of HUM using repeated Gaussian convolution. Results: The proposed method was successfully tested on patient images of common anatomical sites (H/N, lung, abdomen and pelvis). Initial qualitative comparisons showed that this improved HUM method outperformed three recently published algorithms (FCM, LEMS, MICO) in both computation speed (by 50+ times) and robustness (in intermediate to severe inhomogeneity situations). Currently implemented in MATLAB, it takes 20 to 25 seconds to process a 3D MRI volume. Conclusion: Compared to more sophisticated MRI inhomogeneity correction algorithms, the improved HUM method is simple and effective. The inhomogeneity correction, body mask, and FOV detection methods developed in this study would be useful as preprocessing tools for many MRI-related research and clinical applications in radiotherapy. Authors have received research grants from ViewRay and Varian.

60 APPLIED LIFE SCIENCES↗

WE-AB-209-06: Dynamic Collimator Trajectory Algorithm for Use in VMAT Treatment Deliveries

Purpose: To develop advanced dynamic collimator positioning algorithms for optimal beam’s-eye-view (BEV) fitting of targets in VMAT procedures, including multiple metastases stereotactic radiosurgery procedures. Methods: A trajectory algorithm was developed, which can dynamically modify the angle of the collimator as a function of VMAT control point to provide optimized collimation of target volume(s). Central to this algorithm is a concept denoted “whitespace”, defined as area within the jaw-defined BEV field, outside of the PTV, and not shielded by the MLC when fit to the PTV. Calculating whitespace at all collimator angles and every control point, a two-dimensional topographical map depicting the tightness-of-fit of the MLC was generated. A variety of novel searching algorithms identified a number of candidate trajectories of continuous collimator motion. Ranking these candidate trajectories according to their accrued whitespace value produced an optimal solution for navigation of this map. Results: All trajectories were normalized to minimum possible (i.e. calculated without consideration of collimator motion constraints) accrued whitespace. On an acoustic neuroma case, a random walk algorithm generated a trajectory with 151% whitespace; random walk including a mandatory anchor point improved this to 148%; gradient search produced a trajectory with 137%; and bi-directional gradient search generated a trajectory with 130% whitespace. For comparison, a fixed collimator angle of 30° and 330° accumulated 272% and 228% of whitespace, respectively. The algorithm was tested on a clinical case with two metastases (single isocentre) and identified collimator angles that allow for simultaneous irradiation of the PTVs while minimizing normal tissue irradiation. Conclusion: Dynamic collimator trajectories have the potential to improve VMAT deliveries through increased efficiency and reduced normal tissue dose, especially in treatment of multiple cranial metastases, without significant safety concerns that hinder immediate clinical implementation.

60 APPLIED LIFE SCIENCES↗

Collaborative Visualization: Definition, Challenges, and Research Agenda

Collaborative visualization has emerged as a new research direction which offers the opportunity to reach new audiences and application areas for visualization tools and techniques. Technology now allows us to easily connect and collaborate with one another - in settings as diverse as over networked computers, across mobile devices, or using shared displays such as interactive walls and tabletop surfaces. Any of these collaborative settings carries a set of challenges and opportunities for visualization research. Digital information is already regularly accessed by multiple people together in order to share information, to view it together, to analyze it, or to form decisions. However, research on how to best support collaboration with and around visualizations is still in its infancy and has so far focused only on a small subset of possible application scenarios. The purpose of this article is (1) to provide a clear scope, definition, and overview of the evolving field of collaborative visualization, (2) to help pinpoint the unique focus of collaborative visualization with its specific aspects, challenges, and requirements within the intersection of general computer-supported collaborative work (CSCW) and visualization research, and (3) to draw attention to important future research questions to be addressed by the community. Thus, the goal of the paper is to discuss a research agenda for future work on collaborative visualization, including our vision for how to meet the grand challenge and to urge for a new generation of visualization tools that were designed with collaboration in mind from their very inception.

99 GENERAL AND MISCELLANEOUS↗

2D Retrieval Frameworks for Hot Jupiter Phase Curves

Spectroscopic phase curves provide unique access to the three-dimensional properties of transiting exoplanet atmospheres. However, a modeling framework must be developed to deliver accurate inferences of atmospheric properties for these complex data sets. Here, we develop an approach to retrieve temperature structures and molecular abundances from phase curve spectra at any orbital phase. In the context of a representative hot Jupiter with a large day–night temperature contrast, we examine the biases in typical one-dimensional (1D) retrievals as a function of orbital phase/geometry, compared to two-dimensional (2D) models that appropriately capture the disk-integrated phase geometry. We guide our intuition by applying our new framework on a simulated Hubble Space Telescope (HST)+Spitzer phase curve data set in which the “truth” is known, followed by an application to the spectroscopic phase curve of the canonical hot Jupiter, WASP-43b. We also demonstrate the retrieval framework on simulated James Webb Space Telescope (JWST) phase curve observations. We apply our new geometric framework to a joint fit of all spectroscopic phases, assuming longitudinal molecular abundance homogeneity, resulting in an a factor of 2 improvement in abundances precision when compared to individual phase constraints. With a 1D retrieval model on simulated HST+Spitzer data, we find strongly biased molecular abundances for CH{sub 4} and CO{sub 2} at most orbital phases. With 2D, the day and night profiles retrieved from WASP-43b remain consistent throughout the orbit. JWST retrievals show that a 2D model is strongly favored at all orbital phases. Based on our new 2D retrieval implementation, we provide recommendations on when 1D models are appropriate and when more complex phase geometries involving multiple TP profiles are required to obtain an unbiased view of tidally locked planetary atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle↗

Estimating vehicle height using homographic projections

Multiple homography transformations corresponding to different heights are generated in the field of view. A group of salient points within a common estimated height range is identified in a time series of video images of a moving object. Inter-salient point distances are measured for the group of salient points under the multiple homography transformations corresponding to the different heights. Variations in the inter-salient point distances under the multiple homography transformations are compared. The height of the group of salient points is estimated to be the height corresponding to the homography transformation that minimizes the variations.

42 ENGINEERING↗

Comparison of atomized mass and crater volume in laser ablation

The extent and dynamics of laser ablation are typically studied using crater imaging or by invoking the relationship between atomic emission and the mass removed. The former is a static view of a dynamic process and requires the accumulation of multiple shots in one location. The latter is complex and not absolute without calibration of the optical system with a standard of spectral radiance. We measure the mass of the atomized plume by laser atomic-absorption spectroscopy at 2 µs without external mass calibration; mass uncertainty in laser-ablation atomic absorption spectroscopy (LA-AAS) results from uncertainties in line area fitting, tabulated oscillator strengths, and partition functions as well as a <10% underrepresentation of the mass due to treating the plasma as a single thermodynamic equilibrium. The LA-AAS-measured mass pertains to the atoms in the probed charge states and does not include condensed or molecular species. The ablation efficiency at 300 mbar of helium varies significantly between the two focusing conditions used. A comparison of crater-derived masses and LA-AAS masses suggests that more defocused ablation may result in significant redeposition of material in the crater, distorting the conclusions from drilling studies and crater imaging. More focused ablation conditions result in crater-derived masses that exceed those measured with LA-AAS and suggest melt expulsion or phase explosion.

Merten, Jonathan [Arkansas State University, Jones↗

Tomographic Imaging of Glass/Epoxy Composite with a Laser Based Ultrasonics Setup

The present work is an attempt to augment the classical laser-based-ultrasonics setup for tomographic imaging purposes. A Glass/epoxy composite with steel insert is the test specimen and time-of-flight data has been used for tomographic reconstruction. Multiplicative algebraic reconstruction technique is used for this limited-view experiment. The resulting image is able to bring out the strong metal features.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-618: Evaluation of a Mono-Isocentric Treatment Planning Software for Stereotactic Radiosurgery of Multiple Brain Metastases

Purpose: To evaluate planning performance of an automated treatment planning software (BrainLAB; Elements) for stereotactic radiosurgery (SRS) of multiple brain metastases. Methods: Brainlab’s Multiple Metastases Elements (MME) uses single isocentric technique to treat up to 10 cranial planning target volumes (PTVs). The planning algorithm of the MME accounts for multiple PTVs overlapping with one another on the beam eyes view (BEV) and automatically selects a subset of all overlapping PTVs on each arc for sparing normal tissues in the brain. The algorithm also optimizes collimator angles, margins between multi-leaf collimators (MLCs) and PTVs, as well as monitor units (MUs) using minimization of conformity index (CI) for all targets. Planning performance was evaluated by comparing the MME-calculated treatment plan parameters with the same parameters calculated with the Volumetric Modulated Arc Therapy (VMAT) optimization on Varian’s Eclipse platform. Results: Figures 1 to 3 compare several treatment plan outcomes calculated between the MME and VMAT for 5 clinical multi-targets SRS patient plans. Prescribed target dose was volume-dependent and defined based on the RTOG recommendation. For a total number of 18 PTV’s, mean values for the CI, PITV, and GI were comparable between the MME and VMAT within one standard deviation (σ). However, MME-calculated MDPD was larger than the same VMAT-calculated parameter. While both techniques delivered similar maximum point doses to the critical cranial structures and total MU’s for the 5 patient plans, the MME required less treatment planning time by an order of magnitude compared to VMAT. Conclusion: The MME and VMAT produce similar plan qualities in terms of MUs, target dose conformation, and OAR dose sparing. While the selective use of PTVs for arc-optimization with the MME reduces significantly the total planning time in comparison to VMAT, the target dose homogeneity was also compromised due to its simplified inverse planning algorithm used.

60 APPLIED LIFE SCIENCES↗

Deciphering Fingerprints of Stellar Nucleosynthesis Through Nuclear Reaction Rate Measurements and Isotopic Analyses of Stardust

Microscopic stardust grains, found in trace amounts in primitive meteorites, afford a unique opportunity to study stellar nucleosynthesis in the laboratory by measuring their heavy element isotopic compositions. Applying LLNL’s state-of-the art material characterization capabilities to these micrometer-sized grains yields large new datasets with unprecedented precision. However, the astrophysical models necessary to interpret the isotopic record require improved nuclear physics data to constrain stellar nucleosynthesis conditions. For example, the branch point in the s-process path at 95 Zr controls the relative amounts of heavier nuclides but is poorly understood. We conducted a coordinated effort across disciplines to combine a new determination of the neutron capture cross section of 95 Zr with the laboratory analysis of hundreds of stardust grains to yield a view into stellar interiors. We developed new methods to quantify multiple isotopic systems simultaneously (e.g., Zr, Ba, and W) in stardust grains and improved the determination of the neutron capture cross section of unstable 95 Zr via the surrogate reaction method. This interdisciplinary approach is allowing us to fill gaps in our understanding of the environments in which elements are produced while enhancing LLNL’s experimental and theoretical capabilities relevant to nuclear threat reduction missions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Deciphering Fingerprints of Stellar Nucleosynthesis Through Nuclear Reaction Rate Measurements and Isotopic Analyses of Stardust

Microscopic stardust grains, found in trace amounts in primitive meteorites, afford a unique opportunity to study stellar nucleosynthesis in the laboratory by measuring their heavy element isotopic compositions. Applying LLNL’s state-of-the art material characterization capabilities to these micrometer-sized grains yields large new datasets with unprecedented precision. However, the astrophysical models necessary to interpret the isotopic record require improved nuclear physics data to constrain stellar nucleosynthesis conditions. For example, the branch point in the s-process path at 95 Zr controls the relative amounts of heavier nuclides but is poorly understood. We conducted a coordinated effort across disciplines to combine a new determination of the neutron capture cross section of 95 Zr with the laboratory analysis of hundreds of stardust grains to yield a view into stellar interiors. We developed new methods to quantify multiple isotopic systems simultaneously (e.g., Zr, Ba, and W) in stardust grains and improved the determination of the neutron capture cross section of unstable 95 Zr via the surrogate reaction method. This interdisciplinary approach is allowing us to fill gaps in our understanding of the environments in which elements are produced while enhancing LLNL’s experimental and theoretical capabilities relevant to nuclear threat reduction missions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗