Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multichannel analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

213 records · Page 12

Photometric and polarimetric mapping of water turbidity and water depth

A Digital Photometric Mapper (DPM) was used in the Fall of 1971 in an airborne survey of New York and Boston area waters to acquire photometric, spectral and polarimetric data. The object of this study is to analyze these data with quantitative computer processing techniques to assess the potential of the DPM in the measurement and regional mapping of water turbidity and depth. These techniques have been developed and an operational potential has been demonstrated. More emphasis is placed at this time on the methodology of data acquisition, analysis and display than on the quantity of data. The results illustrate the type, quantity and format of information that could be generated operationally with the DPM-type sensor characterized by high photometric stability and fast, accurate digital output. The prototype, single-channel DPM is suggested as a unique research tool for a number of new applications. For the operational mapping of water turbidity and depth, the merits of a multichannel DPM coupled with a laser system are stressed.

Halajian, J.↗

NASA Tech Briefs, December 2005

Topics covered include: Video Mosaicking for Inspection of Gas Pipelines; Shuttle-Data-Tape XML Translator; Highly Reliable, High-Speed, Unidirectional Serial Data Links; Data-Analysis System for Entry, Descent, and Landing; Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes; Multiple Embedded Processors for Fault-Tolerant Computing; Hybrid Power Management; Magnetometer Based on Optoelectronic Microwave Oscillator; Program Predicts Time Courses of Human/ Computer Interactions; Chimera Grid Tools; Astronomer's Proposal Tool; Conservative Patch Algorithm and Mesh Sequencing for PAB3D; Fitting Nonlinear Curves by Use of Optimization Techniques; Tool for Viewing Faults Under Terrain; Automated Synthesis of Long Communication Delays for Testing; Solving Nonlinear Euler Equations With Arbitrary Accuracy; Self-Organizing-Map Program for Analyzing Multivariate Data; Tool for Sizing Analysis of the Advanced Life Support System; Control Software for a High-Performance Telerobot; Java Radar Analysis Tool; Architecture for Verifiable Software; Tool for Ranking Research Options; Enhanced, Partially Redundant Emergency Notification System; Close-Call Action Log Form; Task Description Language; Improved Small-Particle Powders for Plasma Spraying; Bonding-Compatible Corrosion Inhibitor for Rinsing Metals; Wipes, Coatings, and Patches for Detecting Hydrazines; Rotating Vessels for Growing Protein Crystals; Oscillating-Linear-Drive Vacuum Compressor for CO2; Mechanically Biased, Hinged Pairs of Piezoelectric Benders; Apparatus for Precise Indium-Bump Bonding of Microchips; Radiation Dosimetry via Automated Fluorescence Microscopy; Multistage Magnetic Separator of Cells and Proteins; Elastic-Tether Suits for Artificial Gravity and Exercise; Multichannel Brain-Signal-Amplifying and Digitizing System; Ester-Based Electrolytes for Low-Temperature Li-Ion Cells; Hygrometer for Detecting Water in Partially Enclosed Volumes; Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap; Reduction of Flap Side Edge Noise - the Blowing Flap; and Preventing Accidental Ignition of Upper-Stage Rocket Motors.

Source record↗

Measurement of absolute charge-exchange cross sections for He{sup 2+} collisions with He and H{sub 2}

Reported are total, absolute charge-exchange cross sections for collisions of {sup 3}He{sup 2+} ions with He and H{sub 2}. Measurements are reported at fixed energies between 0.33 and 4.67 keV/amu. Both the present results and earlier results of others are analyzed in terms of available experimental small-angle differential cross sections as a function of collision energy, and hence the geometry of the exit aperture of the gas-collision cells used by the various experimental groups. In addition, the effective length of gas-collision cells is studied using fluid dynamic and molecular flow simulations to address the density patterns near the cell entrance and exit apertures. When small acceptance-angle corrections were applied, the results of present and previous measurements for the single electron capture in these systems were brought into good accord in the relevant energy ranges. Taken in their entirety, the present data for {sup 3}He{sup 2+} with He and H{sub 2} lend themselves to new theoretical calculations of the multichannel charge-exchange cross sections.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of multi-channel electron spectrometer

In order to obtain the angular dependent electron energy distributions, we developed a multichannel electron spectrometer (MCESM) with high energy and angular resolutions. The MCESM consists of seven small electron spectrometers set in every 5 deg. on the basement, each of which detection range is up to 25 MeV. In the experiment, we successfully obtained electron spectra from imploded cone-shell target as well as gold plane target irradiated by ultraintense (300 J/5 ps) laser beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-759: To Replan Or Not To Replan for Each Fraction Using Inverse Optimization for Multichannel Vaginal Cylinder

Purpose: This study investigates whether replanning each fraction for vaginal cuff HDR therapy using a multichannel cylinder (MC) and brachytherapy inverse optimization (BIO) provides dosimetric benefits to organs-at-risk (OAR). The goal was to appropriately cover the target and limit dose to OAR, as well as evaluate dosimetric changes for each fraction, while doing this in a timely and cost effective manner. Methods: From an initial selection of 57 patients that were treated with 3 fractions using a MC and BIO, a subset of n=12 patients was selected based on the criterion that one plan was used for all 3 fractions. A simulation CT was acquired prior to each fraction. CT scans for fractions 2 and 3 were fused to the initial CT. Contours for the bladder and rectum were manually drawn on CTs for all 3 fractions, and the clinical treatment volume (PTVeval) was defined. Cylinders were reconstructed using applicator modeling library, influencing time and cost effectiveness. Planning objectives were at least 95% prescription dose to 95% (D95%) of target volume and limiting high dose to OAR. Dose to 2 cm{sup 3} (D2cc) for each OAR was analyzed using a t-test. Results: This study concentrated on comparing 2cm{sup 3} of highest dose to OAR (D2cc), for each fraction for the plans that were used to treat all 3 fraction. Based on statistical analysis, using the initial plan for fractions 2 and 3 resulted in approximately 6% change to the highest D2cc of the bladder (p=0.03). Conclusion: Performing CT fusion and contours of each OAR on each fraction allows objective plan evaluation and supports decision making on the necessity of replanning based on improved dose sparing for OAR. Future studies will investigate the effects of replanning on maximum dose (D0.1cc) using the same physician-drawn OAR contours to avoid subjectivity.

60 APPLIED LIFE SCIENCES↗

Validation, Comparison, and Integration of GOCI, AHI, MODIS, MISR, and VIIRS Aerosol Optical Depth Over East Asia During the 2016 KORUS-AQ Campaign

Recently launched multichannel geostationary Earth orbit (GEO) satellite sensors, such as the Geostationary Ocean Color Imager (GOCI) and the Advanced Himawari Imager (AHI), provide aerosol products over East Asia with high accuracy, which enables the monitoring of rapid diurnal variations and the transboundary transport of aerosols. Most aerosol studies to date have used low Earth orbit (LEO) satellite sensors, such as the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Multi-angle Imaging Spectroradiometer (MISR), with a maximum of one or two overpass daylight times per day from midlatitudes to low latitudes. Thus, the demand for new GEO observations with high temporal resolution and improved accuracy has been significant. In this study the latest versions of aerosol optical depth (AOD) products from three LEO sensors – MODIS (Dark Target, Deep Blue, and MAIAC), MISR, and the Visible/Infrared Imager Radiometer Suite (VIIRS), along with two GEO sensors (GOCI and AHI), are validated, compared, and integrated for a period during the Korea–United States Air Quality Study (KORUS-AQ) field campaign from 1 May to 12 June 2016 over East Asia. The AOD products analyzed here generally have high accuracy with high R (0.84–0.93) and low RMSE (0.12–0.17), but their error characteristics differ according to the use of several different surface-reflectance estimation methods. High-accuracy near-real-time GOCI and AHI measurements facilitate the detection of rapid AOD changes, such as smoke aerosol transport from Russia to Japan on 18–21 May 2016, heavy pollution transport from China to the Korean Peninsula on 25 May 2016, and local emission transport from the Seoul Metropolitan Area to the Yellow Sea in South Korea on 5 June 2016. These high-temporal-resolution GEO measurements result in more representative daily AOD values and make a greater contribution to a combined daily AOD product assembled by median value selection with a 0.5∘×0.5∘ grid resolution. The combined AOD is spatially continuous and has a greater number of pixels with high accuracy (fraction within expected error range of 0.61) than individual products. This study characterizes aerosol measurements from LEO and GEO satellites currently in operation over East Asia, and the results presented here can be used to evaluate satellite measurement bias and air quality models.

Myungje Choi↗

Dissection of the multichannel reaction of acetylene with atomic oxygen: from the global potential energy surface to rate coefficients and branching dynamics

The O( 3 P) + C 2 H 2 reaction is the first step in acetylene oxidation. The accurate kinetic data and the understanding of the reaction dynamics is of great importance. To this end, in this study a full-dimensional global potential energy surface (PES) for the ground triplet state of the O( 3 P) + C 2 H 2 reaction is constructed based on approximately 85,000 ab initio points calculated at the level of explicitly correlated unrestricted coupled cluster single, double, and perturbative triple excitations with the explicitly correlated polarized valence triple zeta basis set (UCCSD(T)-F12b/VTZ-F12). The PES is fit using the permutation invariant polynomial-neural network (PIP-NN) approach with a total root mean square error of 0.21 kcal mol –1 . The key topographic features of the PES, including multiple potential wells and saddle points along different reaction pathways, are well represented by this fit PES. The kinetics and dynamics of the O( 3 P) + C 2 H 2 reaction are investigated using the quasi-classical trajectory (QCT) method. The calculated rate coefficients are in good agreement with experimental data over a wide temperature range, especially when the temperature is lower than 1500 K. The product branch ratio has also been determined, which indicates the H + HCCO channel as the dominant reaction pathway at 298–3000 K, accounting for 80–90% of the overall rate coefficient, in agreement with experimental observations. The dynamics of the reaction is analyzed in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Concerning the width of spark channels with different polarities in submicrosecond sliding discharges in noble gases

Previously, the parameters of submicrosecond (with a duration of <200 ns) multichannel high-current discharges sliding along a ceramic surface in Ne, Ar, and Xe were studied only for the negative polarity of the applied voltage. The experimental data indicate that the channels expand in the transverse direction mainly due to electron drift from the channel surface layer under the action of the electric field perpendicular to the channel axis and subsequent gas ionization by these electrons. To investigate mechanisms for the channel development in a sliding discharge-in particular, to determine the contribution of electron drift-it is necessary to carry out experiments similar to those performed earlier for the opposite polarity of the applied voltage. Here, the results of measurements of the widths of the spark channels of negativeand positive-polarity sliding discharges excited in Ne, Ar, and Xe at pressures of 30 and 100 kPa are presented and discussed. It is shown that, depending on the pressure and sort of gas, the averaged optical width of positive-polarity channels is smaller by a factor of 1.27-1.60 than that of negative-polarity channels. The experimental data are analyzed using the theory of propagation of ionization waves with different polarities in gases. Analysis has shown that electron diffusion contributes insignificantly to channel expansion and that, for both polarities, the channel expansion rate exceeds the electron drift velocity in the transverse electric field near the channel. In the framework of the so-called approximation of nonlocalized initial conditions, the measured ratio between of the widths of negativeand positive-polarity channels and their relation to the electron mobility are explained by the channel expansion governed by both electron drift and primary free electrons produced by a short-term source in a narrow region ahead of the front of the expansion wave. Numerical simulations show that the width of this region is comparable with that of the wave front and is more than one order of magnitude smaller than the observed channel radius. Gas photoionization by the channel radiation can serve as a source of primary electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel, multichannel, comb-frequency Doppler backscatter system

Doppler backscattering has emerged in recent years as a powerful diagnostic tool in high temperature fusion plasmas. The technique is sensitive to plasma turbulence flow and has been utilized to determine radial electric field and to study geodesic acoustic modes, zonal flows, and intermediate scale density turbulence. The current manuscript describes a novel technique for creating a stable, multichannel system covering the V-band frequency range (50-75 GHz) which enables simultaneous monitoring of turbulent flows and fluctuation levels at eight distinct spatial locations. The system is based on a high-frequency, low phase noise comb-frequency generator combined with a filter bank and quadrature detection system. The system is now in operation on DIII-D and has allowed monitoring of the flow and turbulence levels across the plasma radius during events such as the L-H transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seasonally Frozen Soil Monitoring Using Passive Microwave Satellite Data and Simulation Modeling

Satellite data and simulation modeling were used to assess seasonally frozen soils in the central US - Canada borders area (46-53 degrees N and 96-108 degrees). We used Scanning Multichannel Microwave Radiometer (SMMR) satellite data to delineate the top layer of frozen soils. SMMR is a passive microwave sensor having five channels (6.6, 10, 18, 21 and 37 GHz) with a horizontal and vertical polarization. SMRR data are available between 1978-1987 with noon and midnight overpass and footprint sizes between 25 km and 150 km. SMMR data were processed from resampled 1/4 degree grid cells during fall freeze-up and spring thaw (fall 1985 - spring 1987). The dielectric properties of a target may directly affect the satellite signal. The dielectric value is an order of magnitude smaller for frozen soil water. There are other significant changes to the emitted microwave signal from changes to the surface physical temperature, attenuation of the soil signal from plant water and soil moisture. We further characterized the temporal and spatial dynamic of frozen soils using the FroST (Frozen Soil Temperature) simulation model. The FroST model was used to further predict soil water and ice content, and soil temperature. SMMR results were compared versus 5-cm soil temperature data from available weather stations (14 in Canada and 11 for available months in the US). SMMR data were analyzed as a function of frequency, polarization, polarization difference, and "frequency gradient". In addition, vegetation density, physical temperature and snow depth were also considered. Preliminary analysis of SMMR derived frozen soil/thaw classification using a simple threshold classification indicates a mean overall classification accuracy by season of 85 percent. A sensitivity analysis for different soils with varying amounts of snow was conducted with FroST, which showed that the amount of snow, and the time of snow fall and melt affected the ice and water content, and depth of thaw. These results indicate a potential source of flooding and erosion under conditions when melting snow and spring rains provide a source of infiltrating water.

Toll, D. L.↗

Formation of Unsaturated Hydrocarbons and Hydrogen: Surface Chemistry of Methyltrioxorhenium(VII) in ALD of Mixed-Metal Oxide Structures Comprising Re(III) Units

We present the full investigation of the atomic layer deposition (ALD) of a mixed rhenium-aluminum oxide, namely ReAl 2 O 3 CH 3 , a material with tunable resistance, comprising the building unit of conductive rhenium oxides, ReOx. The deposition, involving methyltrioxorhenium(VII) (MeReO 3 , MTO) and trimethylaluminum (TMA), was analyzed by employing complementary in situ diagnostic quartz-crystal microbalance (QCM), Fourier-transform infrared (FT-IR) spectroscopy, and quadrupole mass spectrometry (QMS) to explore and reveal the underlying growth mechanism of this material. A proposed mechanism includes reductive elimination steps, thereby creating a stable Re(III)-containing thin film, making this ALD process unique regarding its growth. In addition, as proven by QMS, the surface reactions include the formation of hydrogen and unsaturated hydrocarbons. From this straightforward process, an extraordinarily high growth rate of 4.5 angstrom cycle -1 at temperatures as low as 150 °C was obtained. This material was found to exhibit highly promising electrical properties in terms of low thermal coefficient of resistance (TCR) in combination with high resistivity. By blending thin films of ReAl 2 O 3 CH 3 with additional layers (1, 2, or 3) of Al 2 O 3 , we were able to fine-tune the electrical resistivity in the range of 3.9 x 10(6) -1.5 x 10 11 Ω.cm. Simultaneously, the TCR was lowered to about -0.014 degrees °C -1 , making this material highly resistive over a broad temperature range and a promising candidate for advanced detector applications, e.g., multichannel plates (MCPs).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of multichannel low-energy neutron spectrometer

A multichannel low-energy neutron spectrometer for down-scattered neutron (DSN) measurements in inertial confinement fusion (ICF) experiments has been developed. Our compact-size 256-channel lithium-glass-scintillator-based spectrometer has been implemented and tested in ICF experiments with the GEKKO XII laser. We have performed time calibration of the 256-channel analog-to-digital convertor system used for DSN measurements via X-ray pulse signals. We have clearly observed the DD-primary fusion neutron signal and have successfully studied the detector's impulse response. Our detector is soon to be implemented in future ICF experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multichannel, time-resolved picosecond laser ultrasound imaging and spectroscopy with custom complementary metal-oxide-semiconductor detector

This paper presents a multichannel, time-resolved picosecond laser ultrasound system that uses a custom complementary metal-oxide-semiconductor linear array detector. This novel sensor allows parallel phase-sensitive detection of very low contrast modulated signals with performance in each channel comparable to that of a discrete photodiode and a lock-in amplifier. Application of the instrument is demonstrated by parallelizing spatial measurements to produce two-dimensional thickness maps on a layered sample, and spectroscopic parallelization is demonstrated by presenting the measured Brillouin oscillations from a gallium arsenide wafer. This paper demonstrates the significant advantages of our approach to pump probe systems, especially picosecond ultrasonics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Data Acquisition System For Multichannel Spectrometer On Base Of The NGDP Framework

In present work it is proposed to implement the data acquisition system (DAQ COMBAS) for the fragment--separator COMBAS under freely distributed UNIX--like operating system (OS) FreeBSD on base of the ngdp framework, which allows to build modular distributed DAQ. As a CAMAC subsystem the camac package (DLNP JINR) is used, which encapsulates code deals with each supported crate controller into corresponding driver. Authors create the driver kh(4) for the PCI adapter of the CC02 controller (Karazin Kharkov National University). The runtime configurable r2h(1) histogram server module is supposed. The histGUI(1) client module is intended for histograms viewing as well as for r2h(1) runtime control and configurating. The histGUI(1) client will not depend on DAQ and ngdp system libraries, so can be compiled under any OS equipped by the ROOT package.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new soft x-ray pulse height analysis array in the HL-2A tokamak

A new soft x-ray pulse height analysis (PHA) array including nine independent subsystems, on basis of a nonconventional software multichannel analysis system and a silicon drift detector (SDD) linear array consisting of nine high performance SDD detectors, has been developed in the HL-2A tokamak. The use of SDD has greatly improved the measurement accuracy and the spatiotemporal resolutions of the soft x-ray PHA system. Since the ratio of peak to background counts obtained from the SDD PHA system is very high, p/b{>=}3000, the soft x-ray spectra measured by the SDD PHA system can approximatively be regarded as electron velocity distribution. The electron velocity distribution can be well derived in the pure ohmic and auxiliary heating discharges. The performance of the new soft x-ray PHA array and the first experimental results with some discussions are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗