Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “module degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Enhancing lifetime, forecasting, and economic benefits of photovoltaic technologies undergoing UV-induced degradation with optical filtering

Ultraviolet-induced degradation (UV-ID) of various PV cell types was analyzed under optical UV filters with different cutoff wavelengths. Cell types studied included interdigitated back contact (IBC), passivated emitter and rear totally diffused (PERT), and heterojunction technology (HJT) based on crystalline Si (c-Si), and metal halide perovskite (MHP) cells. Analyzing degradation rates in two distinct regimes proved beneficial for all cell types. We used empirical linearizing functions ln(t) for c-Si technologies and 2 √t for MHP samples where t is time. These were applied to extrapolate UV-induced degradation over the lifetime of PV modules under various levels of optical UV filtering and used to predict the relative economic benefits for PV power plants. Degradation rates for all technologies were generally faster under the long pass optical filters having shorter cutoff wavelengths transmitting more UV irradiation and at elevated temperatures when testing MHP samples in the range between 60 °C and 90 °C.

14 SOLAR ENERGY↗

PV Lifetime Project (2024 NREL Annual Report)

DOE’s PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions.

14 SOLAR ENERGY↗

Cost Efficient and Highly Weather-Resistant Solar Panel Backsheet Produced through Continuous Co-Extrusion Processing

The efficient generation and delivery of ‘clean energy” through photovoltaic (PV) technology relies heavily on the cost, performance and reliability of solar panels, along with the individual components used in assembly of those panels. In order to continue towards the Department of Energy’s (DOE) goals of driving costs down, the lifetime of high-output power generation equipment (i.e. solar modules) must be extended to reduce costs associated with power output degradation and replacement of failed or degraded panels. One of the major sources of module failures in the past 30 years has been the failure of the solar panel backsheet. Failure of this component causes severe output losses due to oxidation and yellowing of the module while creating safety concerns as the major electrical insulation of the module is compromised. Tomark-Worthen LLC was formed in 2012 with the goal of designing and manufacturing novel PV backsheets and encapsulants that would be produced in the United States of America and exceed expectations of domestic and international module producers. These backsheets would improve upon known backsheet design failures (i.e. Isovoltaic’s AAA backsheet) and create domestic manufacturing jobs in the PV sector. This goal became a reality with a first-generation product in 2018 and now, with the support of the DOE, Tomark-Worthen has launched a second-generation product known as PhotoMark® Reflections™ 205-3 and 360-3. This 2+ year effort began in late 2017 with a screening of potential polymeric materials and backsheet structural designs. Performance evaluations of each material provided the necessary data needed to select the proper material combinations and move forward into the design of the manufacturing process. These decisions were made by teaming with a local university, well-respected government laboratories, and private research organizations who provided the tools necessary to predict long-term performance of these materials in much shorter periods of time. Once the go/no-go criteria were met at the mid-point of the project, the effort transitioned to predicting 30+ year performance, achieving certifications, and improving manufacturing efficiencies designed to lower costs in order to be competitive in a cost-driven market. Major project accomplishments include recognition of the new backsheet by Underwriters Laboratories (UL) and international certification for 1000V and 1500V modules by TUV Sud. Both 1000V and 1500V products have been proven on several module manufacturing lines and initial customer orders have been received by both domestic and international module producers. Accelerated exposure testing has shown that the performance of this backsheet exceeds the prior polyamide-based backsheet known to fail in the field. Cost-models and initial customer orders have shown the ability to produce this backsheet at a cost acceptable to many domestic manufacturers, while International costs for standard backsheet remains extremely low. Tomark-Worthen remains one of the only U.S. companies manufacturing backsheet domestically and this has drawn interest from many domestic module manufacturers looking to improve their material supply logistics by avoiding long lead times and custom’s headaches while avoiding current tariffs on Chinese-made components. Along with the launch of a new PV backsheet, this project has provided a critical deliverable to the PV R&D community. This deliverable is the knowledge that not all polyamide-containing backsheets are doomed to failure as the earlier versions did. There has been a fear amongst the PV community to consider these materials due to the failure of one design. This effort has brought a new level of interest to the scientific community as it has been shown that polyamides can be used successfully in a well-designed backsheet. As we move forward from this project, we are excited to see how backsheet technology and manufacturing in the U.S. will continue to progress and grow.

14 SOLAR ENERGY↗

Photovoltaic Module Imaging for Hail Damage Assessment with Multi-Year Follow Up

Outdoor-aged photovoltaic modules that have experienced golf-ball sized hail are characterized by flash testing and photoluminescence, electroluminescence, thermal, and ultraviolet fluorescence imaging. These measurements were performed immediately after the hailstorm and then again after another two years and four years in the field. The modules originally experienced different ranges of hail damage with some having cracks on approximately half of the cells and some having few to no cracked cells. Flash testing shows that the hail-damaged modules with the most cracked cells have 3 to 4% less power than those with the least damage. After four more years in the outdoor climate of Golden, Colorado since the hailstorm, all of the modules still exhibit similar relative power and amounts of cell cracking, suggesting that the hail damage has only initially reduced power but has not yet increased the degradation rate.

electroluminescence↗

Mutual modulation between surface chemistry and bulk microstructure within secondary particles of nickel-rich layered oxides

Abstract Surface lattice reconstruction is commonly observed in nickel-rich layered oxide battery cathode materials, causing unsatisfactory high-voltage cycling performance. However, the interplay of the surface chemistry and the bulk microstructure remains largely unexplored due to the intrinsic structural complexity and the lack of integrated diagnostic tools for a thorough investigation at complementary length scales. Herein, by combining nano-resolution X-ray probes in both soft and hard X-ray regimes, we demonstrate correlative surface chemical mapping and bulk microstructure imaging over a single charged LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) secondary particle. We reveal that the sub-particle regions with more micro cracks are associated with more severe surface degradation. A mechanism of mutual modulation between the surface chemistry and the bulk microstructure is formulated based on our experimental observations and finite element modeling. Such a surface-to-bulk reaction coupling effect is fundamentally important for the design of the next generation battery cathode materials.

25 ENERGY STORAGE↗

PV Lifetime Project (2021 NREL Annual Report)

DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial performance loss rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field performance loss requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement. Current samples deployed and monitored in this way include Jinko Solar (2016), Trina Solar (2016), Hanwha Q-Cells (2017), Panasonic (2018), LG (2018), Canadian Solar (2018), Mission Solar (2019). More recently, modules from Sunpreme (2019), and LONGi (2020) have been deployed but not yet analyzed. Overall annual performance loss rates are as follows: our first modules to be deployed (Jinko and Trina) have annual median performance loss rate between -0.4%/yr and -0.9%/yr, mainly concentrated in the first year. The QCells mono-PERC and multi-PERC modules have an annual degradation rate of -0.76%/yr and -0.69%/yr respectively, also concentrated in the first year of operation. Panasonic and LG modules displayed negligible performance loss in the past two years, at 0.1%/yr and -0.0%/yr respectively. They also were the only modules with initial IV curve measurements consistently above the nameplate rating. Possibly relatedly, these are also the only two N-type silicon module types analyzed so far. Canadian Solar multi-PERC modules demonstrated a -1.3%/yr degradation rate which actually accelerated in the past year, so this will be a module type to monitor in future years. Mission Solar modules exhibited strong recoverable performance loss, consistent with LeTID susceptibility. (The same is true for the Jinko JKM260 module type). Annual performance loss actually showed improvement in time at +0.3%/yr after 2 years in the field, although the module initially was measured at 3% below nameplate rating. These modules could therefore be experiencing a form of post-LeTID recovery. Initial measurements have been conducted on the next two module types - Sunpreme n-HIT and LONGi bifacial mono-PERC. We will report on initial year-1 performance change for these modules in the next PV Lifetime annual report. For the remaining modules, an additional year of field exposure will provide greater certainty in annual degradation rates, particularly for those with degradation concentrated in the initial year of field deployment.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative (March 2020 Methodology Report)

Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.

14 SOLAR ENERGY↗

Evaluation of bifacial module technologies with combined–accelerated stress testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. Furthermore, this is attributed to previous X-ray topography and modeling work showing higher stress in cells and interconnections in glass-glass modules than glass-backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. We found light-induced degradation (LID) in module types with regenerated (inactive) cells with C-AST, suggesting the possibility of LID destabilization in some field conditions. We could also distinguish potential-induced degradation (PID) on the back of the bifacial passivated emitter and rear cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass-glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while –1200 V system voltage is applied in C-AST, supporting the conclusion that this module type with glass-glass construction would be susceptible to PID in the field.

14 SOLAR ENERGY↗

Impact of acetic acid exposure on metal contact degradation of different crystalline silicon solar cell technologies

Degradation due to acetic acid in photovoltaic (PV) modules has been a commonly observed phenomenon for both damp-heat exposure and outdoor operations. Acetic acid is a degradation byproduct of ethylene-vinyl acetate (EVA), a common module encapsulant. To address this issue, robust metallization pastes and cell technologies are being developed. However, it is important to assess how these technologies perform in an acetic acid environment and withstand degradation before they are implemented in the solar market. In this work, we investigate the impact of acetic acid exposure on four different cell groups: monofacial passivated emitter and rear contact (PERC) cells with advanced telluride-based front contact pastes, bifacial PERC cells with novel aluminum rear contact pastes, bifacial tunnel oxide passivated contacts (TOPCon) cells, and silicon heterojunction (SHJ) cells. These cells were exposed to acetic acid for different time increments. The recombination losses were characterized by Suns-VOC, and multi-variate regression analysis of intensity-dependent photoluminescence (PL) images with Griddler AI. Resistive losses were tracked with the transmission line method (TLM). Samples showing severe performance degradation were selected for further materials characterization to understand the root cause. Top-down and cross-sectional scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray photoelectron spectroscopy (XPS) were performed to investigate the change in materials properties. Our study shows that the front contacts of the bifacial TOPCon cells and monofacial PERC cells were significantly affected by acetic acid exposure. Here, the SHJ cells were found to be the most stable.

14 SOLAR ENERGY↗

UV + Damp Heat Induced Power Losses in Fielded Utility N-Type Si PV Modules

A recent trend in commercial PV modules is a transition to n-type silicon cells, including passivated emitter rear totally diffused (n-PERT), tunnel oxide passivated contact (TOPCon), and silicon heterojunction (SHJ). There is evidence via lab studies that some of these cells are more susceptible to UV induced degradation (UVID), yet there is a lack of confirmation that such degradation occurs in the field. Current IEC standards designed to screen for early module failures require only minimal UV exposure (15 kWh/m2 280-400 nm, ~2-3 months equivalent outdoor exposure). Here, we investigate fielded n-PERT silicon (Si) modules from a commercial utility that show power losses of ~2%/year. We present a comprehensive picture of the physics and chemistry of degradation supported by both module and cell electronic characterization (EL, PL, IV, EQE, and DLIT) and materials-level morphological and chemical analysis (SEM, EDS, XPS, FTIR, and HPLC). All sampled site modules show short circuit current (Isc) and open circuit voltage (Voc) losses when compared to unfielded spares, with the most severely degraded also having losses in fill factor (FF). We identify two different degradation modes contributing to overall power loss: (1) external quantum efficiency (EQE) measurements show losses in the blue range of the spectra, indicative of cell surface recombination losses, and (2) variations in high series resistance (Rs) at the cell level that are correlated with compositional differences in cell metallization. Using unfielded spares, we were able to reproduce Voc, Isc, and EQE losses via a minimum UV stress of 67.5 kWh/m2 (280-400 nm), 4.5x the exposure currently required in IEC 61215-2 (MQT 10). Degradation continued with additional UV dosage equivalent to the fielded modules (405 kWh/m2 total), with power loss leveling out at an average of 6.1%. Subsequent 1000 h of 85% RH/85degrees C damp heat testing showed that cells exposed to UV underwent additional severe series resistance degradation, even those without the susceptible paste composition seen in the field, whereas non-UV exposed cells saw little change. We attribute this to higher concentrations of acetic acid generated on the UV exposed area of the module, leading to degradation of the gridline/cell interface and high Rs. This study is unique in that it reproduces field observed utility scale UVID with an accelerated test and supports the need for standards development for longer UV exposure combined with other stress factors to catch materials interplay within a module package.

14 SOLAR ENERGY↗

Dark Lock-in Thermography Identifies Solder Bond Failure as the Root Cause of Series Resistance Increase in Fielded Solar Modules

Correlating the electrical performance of photovoltaic modules to the spatially resolved photoluminescence, electroluminescence, and dark lock-in thermography (DLIT) images is an important long-term goal for developing solar cell technology. These images offer highly sophisticated and detailed information about the spatial distribution and (if imaged at successive time intervals) temporal degradation of local series and shunt resistances. There have been extensive studies to correlate these imaging techniques to local characteristics at the cell level. However, it has been difficult to extract and quantify module-level information from the techniques. In this study, we interpret module current-voltage (I-V) measurements along with corresponding DLIT images within a module-scale simulation framework, demonstrating that series resistance degradation of the module I-V characteristics, in this case, can be attributed to solder bond failures. Our simulations highlight how current crowding associated with a failed solder joint (or a section of the solder pad) translates to the characteristic point-like (asymmetric doublet) heating pattern in neighboring solder joints (or the neighboring regions of the solder pad). Overall, the correlation between series resistance and solder joint degradation could inform expedited diagnosis of field degradation of solar modules.

42 ENGINEERING↗

A New UV Spot Test for Quality Control

Here, we present a fast, low-cost ultraviolet (UV) spot test to screen photovoltaic modules for UV-induced degradation (UVID). The measurement is based on a fiber-coupled arc lamp that delivers a highly accelerated local UV dose-approximately five years of equivalent field exposure in less than a day. Spot-exposed areas are evaluated using electroluminescence imaging. We test a “known bad” product, which was observed to experience UVID in the field, and a “known good” product which did not exhibit UVID in the field. Results indicate that the method may be useful as a quick and relatively inexpensive quality control screening tool for customers and manufacturers.

14 SOLAR ENERGY↗

The "PVLib" of Degradation: PVDeg

The Photovoltaic (PV) industry constantly aims for lower costs through higher-efficiency cells, improved module designs, and improvements in durability. This leads to the use of new materials, designs, and manufacturing processes, and not always with a sufficient amount of durability testing. To help drive down costs there is a desire to create modules that will last for up to 50 years of service life. To accomplish this, every degradation mode and mechanism must be identified and either eliminated or otherwise mitigated. This involves the extrapolation of laboratory results to the field conditions. There is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. While the basic equations used to model degradation are sometimes very simple, the full analysis involves calculations are cumbersome but ubiquitous for many degradation processes. A simplified, modeling framework to accomplish these repetitive processes will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this talk, we will describe our progress creating the open-source tool PVDeg. This tool can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. PVDeg simplifies many of the common foundational computational operations for obtaining meteorological data and using it to generate a model of the PV deployment. This prediction tool repository also contains various degradation models as well as a library of material parameters suitable for estimating the durability assessment of materials and components. We use an integration pipeline approach that allows us to leverage weather data from the National Solar Radiation Database, and other weather sources, to perform geospatial degradation analysis in the US and worldwide. We hope to become a repository that can be used for weathering and degradation analysis for various applications beyond the PV industry. During the talk, we will provide the PVPMC attendees the opportunity to interact with the tool via a Google Collab tutorial they can run on their phones or laptops.

durability↗

Nanomechanical and Fluorescence Characterizations of Weathered PV Module Encapsulation

Nanoindentation and fluorescence spectroscopy provide spatially resolved mechanical and chemical characterization for degradation of poly (ethylene-co-vinyl acetate) (EVA) encapsulants aged under accelerated weathering and in field deployed photovoltaic (PV) modules. For the accelerated weathering tests, two different EVA formulations in the glass/EVA/glass-laminated coupons were exposed to ultraviolet (UV) light for 180 days at three different temperatures (40, 60, and 80 °C) and UV intensities (0.4, 2.2, and 2.9 W/m2/nm at 340 nm). The fluorescence spectra and moduli were uniform through the cross section of both EVA formulations at the lowest temperature and UV intensity; however, under the highest temperature and UV intensity, the UV irradiated sides showed lower moduli and higher fluorescence compared to the opposite sides. For EVA obtained from PV modules deployed 27 years in Sacramento, CA, USA, changes in fluorescence intensity across the thickness were relatively greater than changes in modulus. On the other hand, for EVA obtained from the same type of module stored in the shed for 27 years, no fluorescence was observed, and a uniform modulus was seen through the EVA layer, but with substantially higher values than those obtained from the field-deployed modules. The different extent of changes between laboratory and field exposures suggests the importance of considering effects of temperature and UV intensity for designing a reliable accelerated testing. This study uniquely demonstrates the capability of microscale characterization using nanoindentation and fluorescence microscopy to monitor mechanical and chemical degradation of EVA encapsulants in PV modules.

14 SOLAR ENERGY↗

Differences in Printed Contacts Lead to Susceptibility of Silicon Cells to Series Resistance Degradation

Here, in this case study, we investigate a degradation mode occurring at the cell level in fielded multi-Si modules. The modules exhibit a mix of affected and unaffected cells. Affected cells show a progressive, series-resistance-related power degradation as shown via module- and cell-level IV curves, along with electroluminescence (EL) and PL imaging at the module, cell, and cell core sample scales. Scanning electron microscopy and energy-dispersive X-ray spectroscopy reveal a difference in the oxides in the silver paste used in screen printing of the gridline contacts. The paste in the affected cells is lead rich, whereas the paste in the unaffected cells is zinc rich. This suggests that the cells were screen printed with different silver paste compositions and possibly firing conditions, and that the different composition correlates with the susceptibility to degradation. Our results indicate degradation of the contact at the oxide-silver interface, causing a severe increase in series resistance across the cell that continues to progress over time.

14 SOLAR ENERGY↗

Performance Modeling of Tandem Photovoltaics: A Yearlong Outdoor Degradation Analysis of a Ga⁢As//Si Minimodule

We present a performance modeling and degradation analysis framework for tandem photovoltaic modules, building upon established procedures for crystalline silicon devices and adapting them to account for the spectral sensitivity of multijunction technologies. The methodology employs filter criteria to select outdoor measurements close to standard test conditions (STC) under stable spectral and ambient conditions, followed by normalization of power production data with corrections for temperature, irradiance, and precipitable water vapor. We demonstrate this framework using a mechanically stacked four-terminal gallium arsenide (Ga⁢As) // silicon (Si) tandem solar minimodule deployed outdoors from October 2019 to January 2021 in Golden, Colorado, USA. We determined degradation rates of −4.1 ±0.2%/year for the Ga⁢As subcell and −2.5 ±0.9%/year for the Si subcell, with analysis of individual performance metrics indicating that packaging degradation, particularly delamination, was the dominant failure mode. Simulations using PVcircuit, an open-source equivalent-circuit solver, confirmed these findings. The presented methodology provides a reproducible foundation for performance modeling and degradation analysis of emerging tandem technologies.

14 SOLAR ENERGY↗

Material characterization of seven photovoltaic backsheets using seven accelerated test conditions

A variety of polymeric backsheet materials can be found in fielded photovoltaic (PV) modules, mostly based on fluoropolymer and polyethylene terephthalate (PET) materials. Cost reduction and sustainability considerations drive the recent development of alternative backsheet materials and designs [1]. In some fielded PV installations, polymeric materials are susceptible to environmental degradation in the form of backsheet cracking. To prevent backsheet degradation that can result in a module failure, thorough laboratory reliability testing is needed. In this report we studied the durability of seven commercial and experimental PV backsheets through accelerated stress testing using seven photolytic, hygrometric, and custom tests with the goal to understand if novel fluoropolymer-free backsheets are sufficiently environmentally durable to be commercialized. We divided the mechanisms observed during aging into two categories: core degradation and surface degradation. Although core degradation due to hydrolysis was observed in all commercial PET-, and polyamide (PA)-based backsheets aged with 85 degrees C/85% relative humidity, this test is unlikely to be field relevant. Photo-oxidative reactions on the exposed surface during UV weathering affected all seven backsheets regardless of the outer layer polymer material and additives. This degradation was limited to the outermost micrometers of the surface, except for backsheets containing PA-12, which resulted in surface cracking. A custom test combining UV with water spray caused the most severe backsheet degradation, including surface erosion and loss of insulating properties in polyolefin (PO)- and PA-based backsheets. This highlights the importance of combined accelerated stress testing to screen for complex backsheet degradation mechanisms. We also showed that, with material and design optimization, coextruded experimental PO-based backsheets have the potential to be a durable alternative to commercial PET- and fluoropolymer-based PV backsheets.

14 SOLAR ENERGY↗

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗