Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Model of Atmospheric Links on Optical Communications from High Altitude

Optical communication links have the potential to solve many of the problems of current radio and microwave links to satellites and high-altitude aircraft. The higher frequency involved in optical systems allows for significantly greater signal bandwidth, and thus information transfer rate, in excess of 10 Gbps, and the highly directional nature of laser-based signals eliminates the need for frequency-division multiplexing seen in radio and microwave links today. The atmosphere, however, distorts an optical signal differently than a microwave signal. While the ionosphere is one of the most significant sources of noise and distortion in a microwave or radio signal, the lower atmosphere affects an optical signal more significantly. Refractive index fluctuations, primarily caused by changes in atmospheric temperature and density, distort the incoming signal in both deterministic and nondeterministic ways. Additionally, suspended particles, such as those in haze or rain, further corrupt the transmitted signal. To model many of the atmospheric effects on the propagating beam, we use simulations based on the beam-propagation method. This method, developed both for simulation of signals in waveguides and propagation in atmospheric turbulence, separates the propagation into a diffraction and refraction problem. The diffraction step is an exact solution, within the limits of numerical precision, to the problem of propagation in free space, and the refraction step models the refractive index variances over a segment of the propagation path. By applying refraction for a segment of the propagation path, then diffracting over that same segment, this method forms a good approximation to true propagation through the atmospheric medium. Iterating over small segments of the total propagation path gives a good approximation to the problem of propagation over the entire path. Parameters in this model, such as initial beam profile and atmospheric constants, are easily modified in a simulation such as this, which allows for the rapid analysis of different propagation scenarios. Therefore, this method allows the development of a near-optimal system design for a wide range of situations, typical of what would be seen in different atmospheric conditions over a receiving ground station. A simulation framework based upon this model was developed in FORTRAN, and for moderate grid sizes and propagation distances these simulations are computable in reasonable time on a standard workstation. This presentation will discuss results thus far.

Subich, Christopher↗

A two-fluid approximation for calculating the cosmic microwave background anisotropies

We present a simplified treatment for calculating the cosmic microwave background anisotropy power spectrum in adiabatic models. It consists of solving for the evolution of a two-fluid model until the epoch of recombination and then integrating over the sources to obtain the cosmic microwave background (CMB) anisotropy power spectrum. The approximation is useful both for a physical understanding of CMB anisotropies as well as for a quantitative analysis of cosmological models. Comparison with exact calculations shows that the accuracy is typically 10%-20% over a large range of angles and cosmological models, including those with curvature and cosmological constant. Using this approximation we investigate the dependence of the CMB anisotropy on the cosmological parameters. We identify six dimensionless parameters that uniquely determine the anisotropy power spectrum within our approximation. CMB experiments on different angular scales could in principle provide information on all these parameters. In particular, mapping of the Doppler peaks would allow an independent determination of baryon mass density, matter mass density, and the Hubble constant.

Seljak, Uros↗

The 8.4-GHz low-noise maser pump source assembly

Improved pump source assemblies and new 8.4-GHz low noise traveling-wave masers (TWMs) were installed at the same time at Deep Space Stations 14 and 43 as part of the Mark IVA DSCC Antenna Microwave Subsystems upgrade. The pump source assemblies are part of the new 8.4-GHz TWMs, which are identified as Block IIA Low-Noise TWMs. Improved reliability of the pump source assemblies was required to meet stress analysis criteria.

Cardenas, R.↗

Arctic sea ice concentrations from special sensor microwave imager and advanced very high resolution radiometer satellite data

Nearly coincident data from the special sensor microwave imager (SSM/I) and the advanced very high resolution radiometer (AVHRR) are used to compute and compare Arctic sea ice concentrations for different regions and times of the year. To help determine overall accuracies and to highlight sources of differences between passive microwave, optical wavelength, and thermal wavelength data, ice concentrations are estimated using two operational SSM/I ice concentration algorithms and with visible- and thermal-infrared wavelength AVHRR data. All algorithms capture the seasonal patterns of ice growth and melt. The ranges of differences fall within the general levels of uncertainty expected for each method and are similar to previous accuracy estimates. The estimated ice concentrations are all highly correlated, with uniform biases, although differences between individual pairs of observations can be large. On average, the NASA Team algorithm yielded 5% higher ice concentrations than the Bootstrap algorithm, while during nonmelt periods the two SSM/I algorithms agree to within 0.5%. These seasonal differences are consistent with the ways that the 19-GHz and 37-GHz microwave channels are used in the algorithms. When compared to the AVHRR-derived ice concentrations, the Team-algorithm results are more similar on average in terms of correlation and mean differences. However, the Team algorithm underestimates concentrations relative to the AVHRR output by 6% during cold months and overestimates by 3% during summer. Little seasonal difference exists between the Bootstrap and AVHRR results, with a mean difference of about 5%. Although the mean differences are less between the SSM/I-derived concentrations and concentrations estimated using AVHRR channel 1, the correlations appear substantially better between the SSM/I data and concentrations derived from AVHRR channel 4, particularly for the Team algorithm output.

Emery, W. J.↗

Apparatus for Use in Determining Surface Conductivity at Microwave Frequencies

An apparatus is provided for use in determining surface conductivity of a flat or shaped conductive material at microwave frequencies. A plate has an electrically conductive surface with first and second holes passing through the plate. An electrically conductive material under test (MUT) is maintained in a spaced apart relationship with the electrically conductive surface of the plate by one or more nonconductive spacers. A first coupling loop is electrically shielded within the first hole while a second coupling loop is electrically shielded within the second hole. A dielectric resonator element is positioned between the first and second coupling loops, while also being positioned closer to the MUT than the electrically conductive surface of the plate. Microwave energy at an operating frequency f is supplied from a signal source to the first coupling loop while microwave energy received at the second coupling loop is measured. The apparatus is capable of measuring the Q-factor of the dielectric resonator situated in the 'cavity' existing between the electrically conductive surface of the plate and the MUT. Surface conductivity of the electrically conductive surface can be determined via interpolation using: 1 ) the measured Q-factor with the electrically conductive surface in place, and 2) the measured Q-factor when the MUT is replaced with reference standards having known surface conductivities.

Hearn, Chase P.↗

Apparatus for use in determining surface conductivity at microwave frequencies

An apparatus is provided for use in determining surface conductivity of a flat or shaped conductive material at microwave frequencies. A plate has an electrically conductive surface with first and second holes passing through the plate. An electrically conductive material under test (MUT) is maintained in a spaced apart relationship with the electrically conductive surface of the plate by one or more non-conductive spacers. A first coupling loop is electrically shielded within the first hole while a second coupling loop is electrically shielded within the second hole. A dielectric resonator element is positioned between the first and second coupling loops, while also being positioned closer to the MUT than the electrically conductive surface of the plate. Microwave energy at an operating frequency f is supplied from a signal source to the first coupling loop while microwave energy received at the second coupling loop is measured. The apparatus is capable of measuring the Q-factor of the dielectric resonator situated in the cavity existing between the electrically conductive surface of the plate and the MUT. Surface conductivity of the electrically conductive surface can be determined via interpolation using: 1) the measured Q-factor with the electrically conductive surface in place, and 2) the measured Q-factor when the MUT is replaced with reference standards having known surface conductivities.

Hearn, Chase P.↗

Detection of Galactic and Extragalactic Millimeter-wavelength Transient Sources with SPT-3G

High angular resolution cosmic microwave background experiments provide a unique opportunity to conduct a survey of time-variable sources at millimeter wavelengths, a population that has primarily been understood through follow-up measurements of detections in other bands. Here we report the first results of an astronomical transient survey with the South Pole Telescope (SPT) using the SPT-3G camera to observe 1500 deg 2 of the southern sky. The observations took place from 2020 March to November in three bands centered at 95, 150, and 220 GHz. This survey yielded the detection of 15 transient events from sources not previously detected by the SPT. The majority are associated with variable stars of different types, expanding the number of such detected flares by more than a factor of two. Additionally, the stellar flares are unpolarized and bright, in some cases exceeding 1 Jy, and have durations from a few minutes to several hours. Another population of detected events last for 2–3 weeks and appear to be extragalactic in origin. Though data availability at other wavelengths is limited, we find evidence for concurrent optical activity for two of the stellar flares. Future data from SPT-3G and forthcoming instruments will provide real-time detection of millimeter-wave transients on timescales of minutes to months.

79 ASTRONOMY AND ASTROPHYSICS↗

A microwave plasma cleaning apparatus

In a microwave electron cyclotron resonance plasma source, reactive plasmas of oxygen and its mixtures of argon have been used for evaluating plasma cleaning technologies. Small aluminum samples (0.95 x 1.9 cm) were coated with thin films (less than or equal to 20 micrometers in thickness) of Shell Vitrea oil and cleaned with reactive plasmas. The discharge parameters, such as gas pressure, magnetic field, substrate biasing, and microwave power, were varied to change cleaning conditions. A mass spectroscopy (or residual gas analyzer) was used to monitor the status of plasma cleaning. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured cleaning rates of low-pressure (0.5-m torr) argon/oxygen plasmas were as high as 2.7 micrometers/min. X-ray photoelectron spectroscopy was used to determine cleanliness of the sample surfaces. In this paper, significant results of the plasma cleaning are reported and discussed.

Tsai, C. C.↗

Electron trapping in evolving coronal structures during a large gradual hard X-ray/radio burst

Gradual hard X-ray/radio bursts are characterized by their long duration, smooth time profile, time delays between peaks at different hard X-ray energies and microwaves, and radiation from extended sources in the low and middle corona. Their characteristic properties have been ascribed to the dynamic evolution of the accelerated electrons in coronal magnetic traps or to the separate acceleration of high-energy electrons in a 'second step' process. The information available so far was drawn from quality considerations of time profiles or even only from the common occurrence of emissions in different spectral ranges. This paper presents model computations of the temporal evolution of hard X-ray and microwave spectra, together with a qualitative discussion of radio lightcurves over a wide spectral range, and metric imaging observations. The basis hypothesis investigated is that the peculiar 'gradual' features can be related to the dynamical evolution of electrons injected over an extended time interval in a coronal trap, with electrons up to relativistic energies being injected simultaneously. The analyzed event (26 April. 1981) is particularly challenging to this hypothesis because of the long time delays between peaks at different X-ray energies and microwave frequencies. The observations are shown to be consistent with the hypothesis, provided that the electrons lose their energy by Coulomb collisions and possibly betatron deceleration. The access of the electrons to different coronal structures varies in the course of the event. The evolution and likely destabilization of part of the coronal plasma-magnetic field configuration is of crucial influence in determining the access to these structures and possibly the dynamical evolution of the trapped electrons through betatron deceleration in the late phase of the event.

Bruggmann, G.↗

Slot-Antenna/Permanent-Magnet Device for Generating Plasma

A device that includes a rectangular-waveguide/slot-antenna structure and permanent magnets has been devised as a means of generating a substantially uniform plasma over a relatively large area, using relatively low input power and a low gas flow rate. The device utilizes electron cyclotron resonance (ECR) excited by microwave power to efficiently generate plasma in a manner that is completely electrodeless in the sense that, in principle, there is no electrical contact between the plasma and the antenna. Plasmas generated by devices like this one are suitable for use as sources of ions and/or electrons for diverse material-processing applications (e.g., etching or deposition) and for ion thrusters. The absence of plasma/electrode contact essentially prevents plasma-induced erosion of the antenna, thereby also helping to minimize contamination of the plasma and of objects exposed to the plasma. Consequently, the operational lifetime of the rectangular-waveguide/ slot-antenna structure is long and the lifetime of the plasma source is limited by the lifetime of the associated charged-particle-extraction grid (if used) or the lifetime of the microwave power source. The device includes a series of matched radiating slot pairs that are distributed along the length of a plasma-source discharge chamber (see figure). This arrangement enables the production of plasma in a distributed fashion, thereby giving rise to a uniform plasma profile. A uniform plasma profile is necessary for uniformity in any electron- or ion-extraction electrostatic optics. The slotted configuration of the waveguide/ antenna structure makes the device scalable to larger areas and higher powers. All that is needed for scaling up is the attachment of additional matched radiating slots along the length of the discharge chamber. If it is desired to make the power per slot remain constant in scaling up, then the input microwave power must be increased accordingly. Unlike in prior ECR microwave plasma-generating devices, there is no need for an insulating window on the antenna. Such windows are sources of contamination and gradually become ineffective as they become coated with erosion products over time. These characteristics relegate prior ECR microwave plasma-generating devices to non-ion beam, non-deposition plasma applications. In contrast, the lack of need for an insulating window in the present device makes it possible to use the device in both ion-beam (including deposition) and electron-beam applications. The device is designed so that ECR takes place above each slot and the gradient of the magnetic field at each slot is enough to prevent backflow of plasma.

Foster, John E.↗

Aspects of Spodumene Lithium Extraction Techniques

Lithium (Li), a leading cathode material in rechargeable Li-ion batteries, is vital to modern energy storage technology, establishing it as one of the most impactful and strategical elements. Given the surge in the electric car market, it is crucial to improve lithium recovery from its rich mineral deposits using the most effective extraction technique. In recent years, both industry and academia have shown significant interest in Li recovery from various Li-bearing minerals. Of these, only extraction from spodumene has established a reliable industrial production of Li salts. The current approaches for cracking of the naturally occurring, stable α-spodumene structure into a more open structure—β-spodumene—involve the so-called decrepitation process that takes place at extreme temperatures of ~1100 °C. This conversion is necessary, as β-spodumene is more susceptible to chemical attacks facilitating Li extraction. In the last several decades, many techniques have been demonstrated and patented to process hard-rock mineral spodumene. The objective of this review is to present a thorough analysis of significant findings and the enhancement of process flowsheets over time that can be useful for both research endeavors and industrial process improvements. The review focuses on the following techniques: acid methods, alkali methods, carbonate roasting/autoclaving methods, sulfuric acid roasting/autoclaving methods, chlorinating methods, and mechanochemical activation. Recently, microwaves (MWs), as an energy source, have been employed to transform α-spodumene into β-spodumene. Considering its energy-efficient and short-duration aspects, the review discusses the interaction mechanism of MWs with solids, MW-assisted decrepitation, and Li extraction efficiencies. Finally, the merits and/or disadvantages, challenges, and prospects of the processes are summarized.

25 ENERGY STORAGE↗

Experimental Investigation of the Effects of Magnetic Mirrors on Plasma Transport in the Prototype Material Plasma Exposure Experiment

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory is developing a helicon radio frequency (RF) source for plasma production along with microwave electron heating and RF ion heating. Proto-MPEX has several magnetic mirrors that affect plasma transport. The magnetic field near the helicon source is ~ 0.05 T, and the peak magnetic field in Proto-MPEX is ~ 1.8 T, which results in a large magnetic well for particles sourced at the helicon transporting toward the target region. Keeping the helicon source field and the target field constant, experiments have been conducted by methodically changing the magnetic field, at a local axial location, within the source and the target. Plasma flow measurements using Mach probes have shown a decrease in the flow as a function of the magnetic mirror ratio. Plasma flows were further investigated with ion cyclotron resonant heating (ICH). Results with the addition of ICH measured upstream of the antenna have shown a decrease in Mach number as a function of mirror ratio when compared to helicon discharges. Such flow behavior demonstrated slowing down of the plasma due to the increased reverse plasma flow toward the helicon plasma source. However, in high magnetic fields, when the resonant magnetic field moved away from the ICH antenna, no effects on the plasma flow due to ICH were observed.

Kafle, Nischal↗

TOPEX/POSEIDON microwave radiometer performance and in-flight calibration

Results of the in-flight calibration and performance evaluation campaign for the TOPEX/POSEIDON microwave radiometer (TMR) are presented. Intercomparisons are made between TMR and various sources of ground truth, including ground-based microwave water vapor radiometers, radiosondes, global climatological models, special sensor microwave imager data over the Amazon rain forest, and models of clear, calm, subpolar ocean regions. After correction for preflight errors in the processing of thermal/vacuum data, relative channel offsets in the open ocean TMR brightness temperatures were noted at the approximately = 1 K level for the three TMR frequencies. Larger absolute offsets of 6-9 K over the rain forest indicated a approximately = 5% gain error in the three channel calibrations. This was corrected by adjusting the antenna pattern correction (APC) algorithm. AS 10% scale error in the TMR path delay estimates, relative to coincident radiosondes, was corrected in part by the APC adjustment and in part by a 5% modification to the value assumed for the 22.235 FGHz water vapor line strength in the path delay retrieval algorithm. After all in-flight corrections to the calibration, TMR global retrieval accuracy for the wet tropospheric range correction is estimated at 1.1 cm root mean square (RMS) with consistent peformance under clear, cloudy, and windy conditions.

Ruf, C. S.↗

Environmental considerations for the microwave beam from a solar power satellite

Solar power satellite (SPS) systems in geosynchronous orbit are possible future energy sources. The SPS concept uses a highly focused microwave beam to transmit the energy to the earth. The microwave power transmission system parameters are summarized, emphasizing those parameters which may affect the earth's environment. Environmental impacts of the microwave beam are discussed. The power levels for the main beam, sidelobes, grating lobes, and ground receiving antenna reradiation patterns are presented. Ionospheric/microwave beam interaction studies, experimental and theoretical, are reviewed. Possible radio frequency interference sources and the magnitude of expected interference levels are discussed.

Arndt, G. D.↗

COBE Differential Microwave Radiometers - Preliminary systematic error analysis

The techniques available for the identification and subtraction of sources of dynamic uncertainty from data of the Differential Microwave Radiometer (DMR) instrument aboard COBE are discussed. Preliminary limits on the magnitude in the DMR 1 yr maps are presented. Residual uncertainties in the best DMR sky maps, after correcting the raw data for systematic effects, are less than 6 micro-K for the pixel rms variation, less than 3 micro-K for the rms quadruple amplitude of a spherical harmonic expansion, and less than 30 micro-(K-squared) for the correlation function.

Kogut, A.↗

Igniter Testing and Development for Liquid Oxygen/Liquid Methane (LOX/LCH4) and Liquid Oxygen/Gaseous Hydrogen (LOX/GH2) Injectors

In support of NASA's efforts to advance methane technology for future exploration missions, two different igniter concepts were developed and tested at NASA's Marshall Space Flight Center for ignition of oxygen/methane propellants. The first type of igniter, an impinging injection, spark-initiated torch igniter (impinging igniter), used traditional spark plug technology to produce a small, but very intense, pulsed plasma as the ignition source. The second type of igniter, a microwave-generated plasma igniter (microwave igniter), used a microwave magnetron to produce a continuous, larger-volume plasma as the ignition source. Two new designs for both types of igniters were leveraged off past oxygen/methane igniter designs that were tested at MSFC and documented in a 2008 JANNAF paper. In this most recent work, the two new igniters were to be tested at the component level as well as inside a liquid oxygen/liquid methane (LOX/LCH4) 40-element swirl coaxial injector. Although the microwave igniter achieved ignition in every test, it encountered technical difficulties that prevented it from being tested with the injector. The impinging igniter required several design iterations as well as testing at different mixture ratios and mass flow rates before reliable operation with minimal ignition delay was achieved. The final design of the impinging igniter was successfully tested in the LOX/LCH4 injector. The same igniter was later re-configured and component-tested to demonstrate reliable ignition of oxygen/hydrogen propellants. Future tests of the impinging igniter will include ignition of a LOX/hydrogen two-stage swirl injector, which is one of several injector concepts being tested in the Lunar Lander Descent Engine Test Bed at MSFC. All igniter and injector tests have been funded by the Propulsion & Cryogenics Advanced Development project managed by Glenn Research Center and sponsored by NASA s Exploration Technology Development Program.

Osborne, Robin J.↗

On the Characterization and Mitigation of Noise in Space-borne Microwave Sounding Instruments

Space-borne microwave sounding instruments have become vital data sources for weather prediction and climate change studies. Among the various radiometer configurations, the total power microwave radiometer is particularly appealing for current and future operational satellites due to its superior sensitivity and simple design. However, its performance is vulnerable to degradation caused by receiver gain fluctuations, electronic 1/f noise, and other time varying receiver characteristics. For Numerical Weather Prediction (NWP) users, 1/f noise introduces inter-channel correlations, complicating the assimilation of affected observations and reducing their accuracy. Addressing this noise issue in ground data processing system is essential to enhance the utility of microwave sounding data. This paper focuses on the characterization and mitigation of noise in current and future microwave sounding instruments, with particular emphasis on the impact of 1/f noise. Various methods are applied to quantitatively characterize noise features in both frequency and time domains. Additionally, the influence of calibration parameters on 1/f noise are analyzed. Based on these findings, we propose a mitigation algorithm for reducing noise during the on-orbit calibration of microwave sounding instruments, aiming to improve the quality of retrieved data for operational use.

calibration↗

Spontaneous Raman scattering as a high resolution XUV radiation source

A type of high resolution XUV radiation source is described which is based upon spontaneous anti-Stokes scattering of tunable incident laser radiation from atoms excited to metastable levels. The theory of the source is summarized and two sets of experiments using He (1s2s)(1)S atoms, produced in a cw hollow cathode and in a pulsed high power microwave discharge, are discussed. The radiation source is used to examine transitions originating from the 3p(6) shell of potassium. The observed features include four previously unreported absorption lines and several sharp interferences of closely spaced autoionizing lines. A source linewidth of about 1.9 cm(-1) at 185,000 cm(-1) is demonstrated.

Rothenberg, J. E.↗