Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

More Accurate Definition of Clinical Target Volume Based on the Measurement of Microscopic Extensions of the Primary Tumor Toward the Uterus Body in International Federation of Gynecology and Obstetrics Ib-IIa Squamous Cell Carcinoma of the Cervix

Purpose: To more accurately define clinical target volume for cervical cancer radiation treatment planning by evaluating tumor microscopic extension toward the uterus body (METU) in International Federation of Gynecology and Obstetrics stage Ib-IIa squamous cell carcinoma of the cervix (SCCC). Patients and Methods: In this multicenter study, surgical resection specimens from 318 cases of stage Ib-IIa SCCC that underwent radical hysterectomy were included. Patients who had undergone preoperative chemotherapy, radiation, or both were excluded from this study. Microscopic extension of primary tumor toward the uterus body was measured. The association between other pathologic factors and METU was analyzed. Results: Microscopic extension toward the uterus body was not common, with only 12.3% of patients (39 of 318) demonstrating METU. The mean (±SD) distance of METU was 0.32 ± 1.079 mm (range, 0-10 mm). Lymphovascular space invasion was associated with METU distance and occurrence rate. A margin of 5 mm added to gross tumor would adequately cover 99.4% and 99% of the METU in the whole group and in patients with lymphovascular space invasion, respectively. Conclusion: According to our analysis of 318 SCCC specimens for METU, using a 5-mm gross tumor volume to clinical target volume margin in the direction of the uterus should be adequate for International Federation of Gynecology and Obstetrics stage Ib-IIa SCCC. Considering the discrepancy between imaging and pathologic methods in determining gross tumor volume extent, we recommend a safer 10-mm margin in the uterine direction as the standard for clinical practice when using MRI for contouring tumor volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Continuum-kinetic-microscopic model of lung clearance due to core-annular fluid entrainment

The human lung is protected against aspirated infectious and toxic agents by a thin liquid layer lining the interior of the airways. This airway surface liquid is a bilayer composed of a viscoelastic mucus layer supported by a fluid film known as the periciliary liquid. The viscoelastic behavior of the mucus layer is principally due to long-chain polymers known as mucins. The airway surface liquid is cleared from the lung by ciliary transport, surface tension gradients, and airflow shear forces. This work presents a multiscale model of the effect of airflow shear forces, as exerted by tidal breathing and cough, upon clearance. The composition of the mucus layer is complex and variable in time. To avoid the restrictions imposed by adopting a viscoelastic flow model of limited validity, a multiscale computational model is introduced in which the continuum-level properties of the airway surface liquid are determined by microscopic simulation of long-chain polymers. A bridge between microscopic and continuum levels is constructed through a kinetic-level probability density function describing polymer chain configurations. The overall multiscale framework is especially suited to biological problems due to the flexibility afforded in specifying microscopic constituents, and examining the effects of various constituents upon overall mucus transport at the continuum scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Macroscopic instructions vs microscopic operations in quantum circuits

In many experiments on microscopic quantum systems, it is implicitly assumed that when a macroscopic procedure or “instruction” is repeated many times – perhaps in different contexts – each application results in the same microscopic quantum operation. But in practice, the microscopic effect of a single macroscopic instruction can easily depend on its context. If undetected, this can lead to unexpected behavior and unreliable results. Here, we design and analyze several tests to detect context-dependence. They are based on invariants of matrix products, and while they can be as data intensive as quantum process tomography, they do not require tomographic reconstruction, and are insensitive to imperfect knowledge about the experiments. We also construct a measure of how unitary (reversible) an operation is, and show how to estimate the volume of physical states accessible by a quantum operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hartmann characterization of the PEEM-3 aberration-corrected X-ray photoemission electron microscope

Aberration correction by an electron mirror dramatically improves the spatial resolution and transmission of photoemission electron microscopes. We will review the performance of the recently installed aberration corrector of the X-ray Photoemission Electron Microscope PEEM-3 and show a large improvement in the efficiency of the electron optics. Hartmann testing is introduced as a quantitative method to measure the geometrical aberrations of a cathode lens electron microscope. Here, we find that aberration correction leads to an order of magnitude reduction of the spherical aberrations, suggesting that a spatial resolution of below 100 nm is possible at 100% transmission of the optics when using x-rays. We demonstrate this improved performance by imaging test patterns employing element and magnetic contrast.

36 MATERIALS SCIENCE↗

A Novel Heating Technology for Ultra-High Resolution Imaging in Electron Microscopes

Capabilities for in-situ studies of materials at elevated temperatures and under gaseous environments have received increasing attention in recent years [1]. With the advent of electron microscopes that provide routine imaging at the atomic level (e.g. aberration-corrected TEM and STEM instruments), it is of particular interest to be able to record images at high temperatures while retaining the inherent resolution of the microscope; that is, the resolution is not limited by drift in the heating holder or other instabilities associated with its operation. Furthermore, there are a number of commercial and experimental heating devices that have been used over the years; some holders are designed with miniature furnaces that heat entire grids [2], while a more recent development used a tiny spiral filament coated with a carbon film as the heater element [3]. These devices, while very useful for some applications (particularly in environmental microscopes that employ differential pumping to allow gases at some elevated pressure to be injected around the specimen), are invariably not as stable as might be desired for sub- Angstrom imaging experiments. The speed at which the sample can be heated to temperature for stable operation also limits them. In collaboration with Protochips Inc. (Raleigh, NC), our laboratory is developing a novel new technology for in-situ heating experiments that overcomes a number of performance problems associated with standard heating stage technologies [4].

36 MATERIALS SCIENCE↗

Microscopic Dynamics Controls Coupling and Cluster Formation in Brush Particle Solids

Thermodynamics-based models predict the structure of polymer-grafted nanoparticles (PGNs) as well as their assembly behavior based on geometric parameters such as particle size, degree of polymerization, and density of grafted chains. The role of microscopic polymer dynamics, such as the mobility of repeat units in the melt state, in the evolution of the structure and properties remains unknown. Brillouin light spectroscopy (BLS), due to its capability to concurrently discern the local and global elastic properties of PGN assemblies, enables the probing of microscopic processes, such as brush interdigitation, sensitive to the annealing of the assembly. For poly(methyl methacrylate) (PMMA)-grafted silica (SiO 2 ) PGNs in the dry powder state and annealed above the glass transition temperature, BLS revealed fully reversible local elasticity, indicative of limited interdigitation between adjacent PGNs. This contrasts with polystyrene (PS)−SiO 2 analogs that displayed ready (and irreversible) fusion of brush layers during annealing. The retardation of brush interdigitation in PMMA-grafted systems is surprising, given the similar thermomechanical properties of both polymers, and is rationalized as the consequence of higher friction between PMMA repeats compared to PS. Microscopic dynamics thus has a profound impact on the kinetic path of structure (and property) evolution and thus should be considered during the processing of PGNs into functional hybrid materials.

chemical structure↗

Microscopic Manipulation of Ferroelectric Domains in SnSe Monolayers at Room Temperature

Two-dimensional (2D) van der Waals ferroelectrics provide an unprecedented architectural freedom for the creation of artificial multiferroics and nonvolatile electronic devices based on vertical and coplanar heterojunctions of 2D ferroic materials. Nevertheless, controlled microscopic manipulation of ferroelectric domains is still rare in monolayer-thick 2D ferroelectrics with in-plane polarization. Here we report the discovery of robust ferroelectricity with a critical temperature close to 400 K in SnSe monolayer plates grown on graphene and the demonstration of controlled room-temperature ferroelectric domain manipulation by applying appropriate bias voltage pulses to the tip of a scanning tunneling microscope (STM). This study shows that STM is a powerful tool for detecting and manipulating the microscopic domain structures in 2D ferroelectric monolayers, which are difficult for conventional approaches such as piezoresponse force microscopy, thus facilitating the hunt for other 2D ferroelectric monolayers with in-plane polarization with important technological applications.

2D ferroelectric↗

Many-Body State Description of Single-Molecule Electroluminescence Driven by a Scanning Tunneling Microscope

Electron transport and optical properties of a single molecule in contact with conductive materials have attracted considerable attention because of their scientific importance and potential applications. With the recent progress in experimental techniques, especially by virtue of scanning tunneling microscope (STM)-induced light emission, where the tunneling current of the STM is used as an atomic-scale source for induction of light emission from a single molecule, it has become possible to investigate single-molecule properties at subnanometer spatial resolution. Despite extensive experimental studies, the microscopic mechanism of electronic excitation of a single molecule in STM-induced light emission has yet to be clarified. Here we present a formulation of single-molecule electroluminescence driven by electron transfer between a molecule and metal electrodes based on a many-body state representation of the molecule. The effects of intramolecular Coulomb interaction on conductance and luminescence spectra are investigated using the nonequilibrium Hubbard Green’s function technique combined with first-principles calculations. We compare simulation results with experimental data and find that the intramolecular Coulomb interaction is crucial for reproducing recent experiments for a single phthalocyanine molecule. The developed theory provides a unified description of the electron transport and optical properties of a single molecule in contact with metal electrodes driven out of equilibrium, and thereby, it contributes to a microscopic understanding of optoelectronic conversion in single molecules on solid surfaces and in nanometer-scale junctions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microscopic Origins of the Nonlinear Behavior of Particle-Filled Rubber Probed with Dynamic Strain XPCS

The underlying microscopic response of filler networks in reinforced rubber to dynamic strain is not well understood due to the experimental difficulty of directly measuring filler network behavior in samples undergoing dynamic strain. This difficulty can be overcome with in situ X-ray photon correlation spectroscopy (XPCS) measurements. The contrast between the silica filler and the rubber matrix for X-ray scattering allows us to isolate the filler network behavior from the overall response of the rubber. This in situ XPCS technique probes the microscopic breakdown and reforming of the filler network structure, which are responsible for the nonlinear dependence of modulus on strain, known in the rubber science community as the Payne effect. These microscopic changes in the filler network structure have consequences for the macroscopic material performance, especially for the fuel efficiency of tire tread compounds. In this work, we elucidate the behavior with in situ dynamic strain XPCS experiments on industrially relevant, vulcanized rubbers filled (13 vol %) with novel air-milled silica of ultrahigh-surface area (UHSA) (250 m 2 /g). The addition of a silane coupling agent to rubber containing this silica causes an unexpected and counterintuitive increase in the Payne effect and decrease in energy dissipation. For this rubber, we observe a nearly two-fold enhancement of the storage modulus and virtually equivalent loss tangent compared to a rubber containing a coupling agent and conventional silica. Interpretation of our in situ XPCS results simultaneously with interpretation of traditional dynamic mechanical analysis (DMA) strain sweep experiments reveals that the debonding or yielding of bridged bound rubber layers is key to understanding the behavior of rubber formulations containing the silane coupling agent and high-surface area silica. These results demonstrate that the combination of XPCS and DMA is a powerful method for unraveling the microscale filler response to strain which dictates the dynamic mechanical properties of reinforced soft matter composites. With this combination of techniques, we have elucidated the great promise of UHSA silica when used in concert with a silane coupling agent in filled rubber. Such composites simultaneously exhibit large moduli and low hysteresis under dynamic strain.

36 MATERIALS SCIENCE↗

Fast scanning mode and its realization in a scanning acoustic microscope

The scanning speed of the two-dimensional stage dominates the efficiency of mechanical scanning measurement systems. This paper focused on a detailed scanning time analysis of conventional raster and spiral scan modes and then proposed two fast alternative scanning modes. Performed on a self-developed scanning acoustic microscope (SAM), the measured images obtained by using the conventional scan mode and fast scan modes are compared. The total scanning time is reduced by 29% of the two proposed fast scan modes. It will offer a better solution for high speed scanning without sacrificing the system stability, and will not introduce additional difficulties to the configuration of scanning measurement systems. They can be easily applied to the mechanical scanning measuring systems with different driving actuators such as piezoelectric, linear motor, dc motor, and so on. The proposed fast raster and square spiral scan modes are realized in SAM, but not specially designed for it. Therefore, they have universal adaptability and can be applied to other scanning measurement systems with two-dimensional mechanical scanning stages, such as atomic force microscope or scanning tunneling microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmons in molecules: Microscopic characterization based on orbital transitions and momentum conservation

In solid state physics, electronic excitations are often classified as plasmons or single-particle excitations. The former class of states refers to collective oscillations of the electron density. The random-phase approximation allows for a quantum-theoretical treatment and a characterization on a microscopic level as a coherent superposition of a large number of particle-hole transitions with the same momentum transfer. However, small systems such as molecules or small nanoclusters lack the basic properties (momentum conservation and uniform exchange interaction) responsible for the formation of plasmons in the solid-state case. Despite an enhanced interest in plasmon-based technologies and an increasing number of studies regarding plasmons in molecules and small nanoclusters, their definition on a microscopic level of theory remains ambiguous. In this work, we analyze the microscopic properties of molecular plasmons in comparison with the homogeneous electron gas as a model system. Subsequently, the applicability of the derived characteristics is validated by analyzing the electronic excitation vectors with respect to orbital transitions for two linear polyenes within second order versions of the algebraic diagrammatic construction scheme for the polarization propagator.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NMR diffusion-encoding with axial symmetry and variable anisotropy: Distinguishing between prolate and oblate microscopic diffusion tensors with unknown orientation distribution

We introduce a nuclear magnetic resonance method for quantifying the shape of axially symmetric microscopic diffusion tensors in terms of a new diffusion anisotropy metric, D{sub Δ}, which has unique values for oblate, spherical, and prolate tensor shapes. The pulse sequence includes a series of equal-amplitude magnetic field gradient pulse pairs, the directions of which are tailored to give an axially symmetric diffusion-encoding tensor b with variable anisotropy b{sub Δ}. Averaging of data acquired for a range of orientations of the symmetry axis of the tensor b renders the method insensitive to the orientation distribution function of the microscopic diffusion tensors. Proof-of-principle experiments are performed on water in polydomain lyotropic liquid crystals with geometries that give rise to microscopic diffusion tensors with oblate, spherical, and prolate shapes. The method could be useful for characterizing the geometry of fluid-filled compartments in porous solids, soft matter, and biological tissues.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large area fabrication of plasmonic nanoparticle grating structure by conventional scanning electron microscope

Plasmonic nanoparticle grating (PNG) structure of different periods has been fabricated by electron beam lithography using silver halide based transmission electron microscope film as a substrate. Conventional scanning electron microscope is used as a fabrication tool for electron beam lithography. Optical microscope and energy dispersive spectroscopy (EDS) have been used for its morphological and elemental characterization. Optical characterization is performed by UV-Vis absorption spectroscopic technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new apparatus for electron tomography in the scanning electron microscope

The three-dimensional reconstruction of a microscopic specimen has been obtained by applying the tomographic algorithm to a set of images acquired in a Scanning Electron Microscope. This result was achieved starting from a series of projections obtained by stepwise rotating the sample under the beam raster. The Scanning Electron Microscope was operated in the scanning-transmission imaging mode, where the intensity of the transmitted electron beam is a monotonic function of the local mass-density and thickness of the specimen. The detection strategy has been implemented and tailored in order to maintain the projection requirement over the large tilt range, as required by the tomographic workflow. A Si-based electron detector and an eucentric-rotation specimen holder have been specifically developed for the purpose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication of large area plasmonic nanoparticle grating structure on silver halide based transmission electron microscope film and its application as a surface enhanced Raman spectroscopy substrate

The plasmonic responses of silver nanoparticle grating structures of different periods made on silver halide based electron microscope film are investigated. Raster scan of the conventional scanning electron microscope (SEM) is used to carry out electron beam lithography for fabricating the plasmonic nanoparticle grating (PNG) structures. Morphological characterization of the PNG structures, carried out by the SEM and the atomic force microscope, indicates that the depth of the groove decreases with a decrease in the grating period. Elemental characterization performed by the energy dispersive spectroscopy and the x-ray diffraction shows the presence of nanoparticles of silver in the PNG grating. The optical characterization of the gratings shows that the localized surface plasmon resonance peak shifts from 366 to 378 nm and broadens with a decrease in grating period from 10 to 2.5 μm. The surface enhanced Raman spectroscopy of the Rhodamine-6G dye coated PNG structure shows the maximum enhancement by two orders of magnitude in comparison to the randomly distributed silver nanoparticles having similar size and shape as the PNG structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of process-induced damage in Cu/low-k interconnect structure by microscopic infrared spectroscopy with polarized infrared light

Microscopic Fourier-transform infrared (FT-IR) spectra are measured for a Cu/low-k interconnect structure using polarized IR light for different widths of low-k spaces and Cu lines, and for different heights of Cu lines, on Si substrates. Although the widths of the Cu line and the low-k space are 70 nm each, considerably smaller than the wavelength of the IR light, the FT-IR spectra of the low-k film were obtained for the Cu/low-k interconnect structure. A suitable method was established for measuring the process-induced damage in a low-k film that was not detected by the TEM-EELS (Transmission Electron Microscope-Electron Energy-Loss Spectroscopy) using microscopic IR polarized light. Based on the IR results, it was presumed that the FT-IR spectra mainly reflect the structural changes in the sidewalls of the low-k films for Cu/low-k interconnect structures, and the mechanism of generating process-induced damage involves the generation of Si-OH groups in the low-k film when the Si-CH{sub 3} bonds break during the fabrication processes. The Si-OH groups attract moisture and the OH peak intensity increases. It was concluded that the increase in the OH groups in the low-k film is a sensitive indicator of low-k damage. We achieved the characterization of the process-induced damage that was not detected by the TEM-EELS and speculated that the proposed method is applicable to interconnects with line and space widths of 70 nm/70 nm and on shorter scales of leading edge devices. The location of process-induced damage and its mechanism for the Cu/low-k interconnect structure were revealed via the measurement method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A framed, 16-image Kirkpatrick–Baez x-ray microscope

A 16-image Kirkpatrick–Baez (KB)–type x-ray microscope consisting of compact KB mirrors has been assembled for the first time with mirrors aligned to allow it to be coupled to a high-speed framing camera. The high-speed framing camera has four independently gated strips whose emission sampling interval is ~30 ps. Images are arranged four to a strip with ~60-ps temporal spacing between frames on a strip. By spacing the timing of the strips, a frame spacing of ~15 ps is achieved. A framed resolution of ~6-um is achieved with this combination in a 400-um region of laser–plasma x-ray emission in the 2- to 8-keV energy range. A principal use of the microscope is to measure the evolution of the implosion stagnation region of cryogenic DT target implosions on the University of Rochester’s OMEGA Laser System. The unprecedented time and spatial resolution achieved with this framed, multi-image KB microscope have made it possible to accurately determine the cryogenic implosion core emission size and shape at the peak of stagnation. In conclusion, these core size measurements, taken in combination with those of ion temperature, neutron-production temporal width, and neutron yield allow for inference of core pressures, currently exceeding 50 GBar in OMEGA cryogenic target implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A modular ultra-high vacuum millikelvin scanning tunneling microscope

We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our design is to achieve a high level of modularity by partitioning the STM system into a set of easily separable, interchangeable components. This naturally segregates the UHV needs of STM instrumentation from the typically non-UHV construction of a dilution refrigerator, facilitating the usage of non-UHV materials while maintaining a fully bakeable UHV chamber that houses the STM. Here, the modular design also permits speedy removal of the microscope head from the rest of the system, allowing for repairs, modifications, and even replacement of the entire microscope head to be made at any time without warming the cryostat or compromising the vacuum. Without using cryogenic filters, we measured an electron temperature of 184 mK on a superconducting Al(100) single crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗