Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microgrids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Integrated Synchronization Control of Grid-Forming Inverters for Smooth Microgrid Transition: Preprint

This paper develops an integrated synchronization control technique for a grid-forming inverter operating within a microgrid that can improve the microgrid's transients during microgrid transition operation. This integrated synchronization control includes the disconnection synchronization control and the reconnection synchronization control. The simulation results show that the developed synchronization control works effectively to smooth the angle change of the grid-forming inverter during microgrid transition operation. Thus, the microgrid's transients are significantly improved compared to the case without synchronization control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Smart Microgrids for the Developing World with Probabilistic Supply and Demand Inputs

Developing world microgrids often balance insufficient supply with growing, unpredictable demand. Deterministic and probabilistic simulators exist to model these microgrids, and each focuses on different technical aspects. With the addition of smart meters into microgrids, monitoring and control is now available at high granularity, which enriches microgrid planning and operation. This research is designing a new simulator to model smart microgrids with discrete probability distributions as supply and demand inputs. In our model, smart meters allow real-time power clipping for demand side management, effectively smoothing the system load curve as needed. To compare clipping schemes for grid operation and generation mixes for planning, we aggregate inputs by convolution then compute expected energy sold and probability of avoiding power cuts. The simulator plots these values for different combinations of power clipping threshold and number of customers clipped.

13 HYDRO ENERGY↗

Use of Grid-Forming Medium-Voltage Power Electronics Hub in a Microgrid Setting: Preprint

This paper presents the application of a new design of a multiport, modular, medium-voltage power electronics hub (M3PE-HUB) in a microgrid setting. The M3PE-HUB system was modeled in a digital real-time simulator (DRTS) and integrated into the Banshee microgrid test system. This paper presents the preliminary DRTS simulation-based results of the M3PE- HUB system connected in a test microgrid system. Verification and validation of the M3PE-HUB architecture and controls in the test microgrid setting are the primary contributions of this work. The results of the operation during the islanding and resynchronization process indicate the feasibility of the proposed architecture in a microgrid setting. This paper also presents results for a system reconfiguration use case where the M3PE- HUB was used to reconfigure the system under a fault condition.

grid forming↗

Assessing the Viability of Geothermal Microgrid Deployment: A Geospatial Analysis Across the United States

Geothermal microgrids hold a potential of supplying clean and dependable power to communities throughout the United States (US), all while sidestepping the expenses associated with connecting to strained or isolated power grids. Nonetheless, their implementation is still in its early stages in the country. The objective of this analysis is to leverage available data to pinpoint regions across the US that exhibit favorable conditions for the development of geothermal microgrids. Drawing from a variety of sources, including estimates of geothermal resources, the costs associated with geothermal energy generation and electricity transmission, existing microgrid locations, and subsidy programs, we aim to identify promising areas for further exploration. By mapping out the contiguous US, Alaska, and Hawaii, we delineate regions with high relative favorability for geothermal microgrid deployment. Our findings reveal the presence of highly favorable regions across the Western states of the contiguous US, as well as isolated areas in Alaska and Hawaii. Furthermore, we delve into a discussion on state policies and incentive programs, considering their role in fostering favorable conditions or posing barriers to geothermal microgrid development.

Alaska↗

Power-Hardware-in-the-Loop Experiments of a Microgrid With a Grid-Forming Battery Inverter: Preprint

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calibrating Synchronous-Generator-Interfaced DG Models in Microgrids Using Multiple Event Data

Microgrids, consisting of distributed generators (DGs), loads, and energy storage systems, play an important role in future smart grids. In order to evaluate how microgrids operate and their dynamic response, it is necessary to develop accurate dynamic models of DGs in microgrids. This paper proposes a systematic method to calibrate synchronous-generator-interfaced DG models. Challenges associated with model validation in microgrids are analyzed. Underlying parameters are categorized into two groups, i.e., the steady-state parameters and time constants, which are estimated in two successive stages using multiple event data. This methodology ensures that the validated model with the estimated parameters are applicable for all events. A modified unscented Kalman filter (UKF) is proposed to deal with the cases in which measurement of power angle is unavailable. The effectiveness of the proposed method is validated using field test data of a 2.6 MVA diesel generator in a real microgrid.

Wang, Zhiwen↗

A Comparison of PV Resource Modeling for Sizing Microgrid Components

Microgrid systems are being deployed with increased frequency to meet critical building loads during unplanned power outages. Determining the appropriate type and size of components that make up a microgrid can greatly affect its ability to meet this need. This paper presents a new tool to appropriately size PV, battery, and generator capacities to meet all site loads, given a resilience goal. It uses a statistical model to simulate microgrid behavior under a large range of solar resource conditions, providing resilience planners with confidence that critical loads will be met even under extreme weather conditions. We compare this model with one that uses typical weather data for sizing microgrids, and quantify the resilience effects of using these different methods. Our method produces more conservative generator capacities and fuel requirements in an outage, predicting up to 30% more fuel required in the most extreme case. Microgrid systems that are designed using more conservative estimates are more likely to continue to serve load during emergency outages under a large range of conditions.

Newman, Sarah F.↗

A Mixed integer linear programming‐based distributed energy management for networked microgrids considering network operational objectives and constraints

Abstract Mixed integer linear programming (MILP)–based distributed energy management for networked microgrids embedded modern distribution systems is proposed. Considering the diverse ownership of microgrids, distributed energy resources (DERs) that interface directly with utilities and responsive loads, an alternating direction method of multipliers–based distributed framework was formulated for the scheduling of networked microgrids embedded modern distribution systems by adjusting nodal price signals iteratively. In addition, to make the formulated optimization problems resolvable through more accessible and popular MILP solvers, different linearisation techniques were employed to transform the nonlinear terms into linear or mixed integer linear formats. The proposed MILP‐based distributed method preserves all participants' autonomy (e.g., microgrids, DERs that interface directly with utilities and responsive loads), while incentivising them to actively participate in the distribution system operation with price signals. The proposed method is validated with results of numerical simulation using a modern distribution system consisting of multiple networked microgrids, DERs that interface directly with utilities, as well as responsive loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CyPhyR: a cyber‐physical analysis tool for measuring and enabling resiliency in microgrids

This study presents a tool to study the cyber‐physical resiliency (CyPhyR) of critical energy infrastructure system, in particular the effect of cyber attacks on the microgrid's resiliency. The developed tool enables measuring resiliency using data from cyber and physical systems and suggests control decisions for resilient planning and operation of the microgrid. The microgrid resiliency is formulated based on graph theory based indices and cyber‐power system characteristics. A Common Vulnerability Scoring System based metric called the Cyber Asset Impact Potential is developed and used in the planning phase, and another metric, Cyber Impact Severity is introduced to study the system performance in the operational phase. The information from these two phases is provided to the operator to make informed and proactive decisions to ensure the resilient operation of the microgrid. The performance of the developed tool has been tested using comprehensive real‐time cyber‐power testbed for a Consortium for Electric Reliability Technology Solutions microgrid test system.

Venkataramanan, Venkatesh↗

Real-time power management technique for microgrid with flexible boundaries

In order to diminish the impacts brought by high penetration of renewable energy on the reliability of distribution systems, some distribution networks (e.g. Chattanooga electric power board system) have deployed smart switches (SSs) to island some areas to mitigate outage losses. However, due to intermittency and sharply changing rate of renewable energy, it is likely to experience insufficient or excessive power for islanded areas. Therefore, a microgrid controller featured with flexible boundaries is proposed. With proposed microgrid controller, the microgrid can not only shrink or expand its boundaries according to current renewable energy supply, but also disconnect/connect to the main grid with a designated SS. Furthermore, to ensure the microgrid controller could obtain suitable boundaries on the time scale of seconds, a real-time power management technique with alternative generating algorithm is designed to generate all possible alternative boundaries and choose the optimal one, which is scalable to any topology. In addition, in order to maintain state of charge of batteries within a desirable range, anti-overcharge/discharge strategies are designed. Four comprehensive experiments verify that the implementation of the microgrid controllers can realise flexible boundaries and deal with sharply changing rate of renewable generation or load on the time scale of seconds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Graph theory and nighttime imagery based microgrid design

Reducing the duration and frequency of blackouts in remote communities poses an engineering challenge for grid operators. Outage effects can also be mitigated locally through microgrids. This paper develops a systematic procedure to account for these challenges by creating microgrids prioritizing high value assets within vulnerable communities. Nighttime satellite imagery is used to identify vulnerable communities. Using an asset classification and rating system, multi-asset clusters within these communities are prioritized. Infrastructure data, geographic information systems, satellite imagery, and spectral clustering are used to form and rank microgrid candidates. A microgrid sizing algorithm is included to guide through the microgrid design process. Finally, an application of the methodology is presented using real event, location, and asset data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Converter Based Microgrid Test Platform

To overcome the limitations of digital simulation (numerical oscillation, limited computing capability of processors, etc.), a converter-based hardware test-bed was developed at CURENT for real-time power grid emulation. However, distribution systems especially microgrids cannot be emulated and tested on the existing hardware test-bed. This paper develops a microgrid test-bed based on the existing hardware test-bed to enable controller testing for microgrids with dynamic boundary. The design and realization of the microgrid hardware test-bed are introduced. The experimental results of the microgrid controller tests are also provided.

Li, Dingrui↗

Smart Inverters for Seamless Reconnection of Isolated Residential Microgrids to Utility Grid

This paper proposes an approach to achieve seamless reconnection of isolated residential microgrids to utility grid. Any abnormal condition on the grid side results in isolating the residential microgrid from utility grid, and giving the full responsibility of supplying household loads to local distributed generation (DG) units. However, after resolving the abnormal condition on the grid side, the residential microgrid needs to seamlessly reconnect to the main grid. To this end, a seamless transition algorithm is presented which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid before reconnection to the main grid. A modified control scheme is proposed for single-phase inverters which turns them into smart inverters enable to interact with seamless transition algorithm. The proposed approach synchronizes each phase voltage with its respective grid-side voltage in order to seamlessly reconnect the residential microgrid to the main grid. Case study results are carried out in PSCAD/EMTDC environment to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Microgrid Building Block Architecture, and Subcomponents Modeling and Demonstration in Controller Hardware-in-the-Loop

The recently proposed Microgrid Building Blocks (MBB) are ready-to-use components to build microgrids quickly, cheaply, and modularly. This work presents and demonstrates in controller hardware-in-the-loop (CHIL) three key subcomponents of an MBB architecture: power converter topology, control scheme, and communication framework. The addressed architecture aims for systems interconnection such as microgrid to grid and microgrid to microgrid. This paper studies each subcomponent in detail and validates the efficacy of the architecture through CHIL results.

Adib, Aswad [ORNL] (ORCID:000000020997056X)↗

Model-Free Dynamic Voltage Control of a Synchronous Generator-Based Microgrid

The main goal of this paper is to present a new dynamic voltage stability mechanism, based on model-free control (MFC), for effective control and coordination of synchronous generator (SG)-based reactive power resources in a microgrid setting. MFC has shown successful operation in various domains, and this paper presents its first use in the voltage stability of a power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by SG-based distributed energy resources (DERs) is considered as a use case study. The overall dynamic voltage stability of the microgrid system is investigated using time-domain dynamic simulations during emergency, hazard, and disaster events. Simulation results show that there are significant improvements and enhancements on the dynamic load bus voltage profiles of the microgrid system by the effective model-free control and coordination of the reactive power reserves of the SG-based DERs.

Hatipoglu, Kenan↗

Passivity-Based Control of Grid Forming and Grid Following Converters in Microgrids

With the integration of more and more power electronics devices into the grid, it is not easy to guarantee the stability of the whole system due to the complexity of the control structure of various power converters. In this paper, we consider grid-forming and grid-following converters in one microgrid, in which the grid-forming converters support the voltage and frequency of the microgrid and the grid-following converters inject their maximum power into the microgrid. To handle the stability issue, the passivity principle is applied to guarantee the stability of the whole microgrid. We ensure every grid-following converter satisfies the passivity via the port-controlled Hamiltonian method. In addition, we apply the passivity-based proportional-resonant controller to the grid-forming converter. One of the advantages of the proposed method is that the phase lock loop system is eliminated, which may cause stability issues. Simulation results show that the proposed method can control the microgrid effectively.

Gui, Yonghao (Young)↗

Coordination of Networked Microgrids for Supporting Voltages of Bulk Power Systems

Active distribution system resources have the potential to support the bulk power system (BPS) during abnormal conditions, increasing reliability and resilience of power systems and end-use customers. This paper investigates for the first time the BPS voltage support provided by networked microgrids at the feeder level. A peer-to-peer (P2P) communication control framework is introduced to enable the coordination of multiple microgrids in a mixed ownership environment. This allows the microgrids to run a consensus algorithm (CA) to distributedly determine their own reactive power injections. Thus, the reactive power injection contribution is realized in a fair manner by having the same ratio of reactive power injection to the reactive power headroom for all microgrids. The CA implementation and performance within the P2P network framework are demonstrated on the IEEE 39-bus testcase system with 10 microgrids part of the distribution feeder assumed to be connected to one of the BPS buses.

Vu, Thanh Long↗