Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microchannel plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Spectrometer system for diffuse extreme ultraviolet radiation

A unique grazing incidence spectrometer system has been designed to study diffuse line emission between 80 and 650 A with 10-30 A resolution. The minimum detectable emission line strength during a 5-min observation ranges from 100-2000 ph/sq cm sec str. The instrument uses mechanically ruled reflection gratings placed in front of a linear array of mirrors. These mirrors focus the spectral image on microchannel plate detectors located behind thin filters. The field of view is 40 min of arc by 15 deg, and there is no spatial imaging. This instrument has been fabricated, calibrated, and successfully flown on a sounding rocket to observe the astronomical background radiation.

Labov, Simon E.↗

High resolution decoding techniques and single-chip decoders for multi-anode microchannel arrays

While the pixel size in a standard multianode microchannel array (MAMA) photon-counting detector is determined by the spacing of the anode array, the factor most fundamentally limiting pixel resolution is the spacing of the channels in the microchannel plate. Detector resolution can be improved by means of digitization followed by a centroiding procedure. The decoding hardware and the techniques for enhanced pixel resolution are presently discussed with a view to the factors of speed and complexity. A single-chip CMOS gate-array implementation of the decoder is devised and compared with existing multichip decoders' performance.

Kasle, David B.↗

Development and testing of a prototype mosaic wedge-and-strip anode detector

A preliminary laboratory study of a prototype mosaic wedge-and-strip anode, a new class of readout system that will furnish large format, high resolution microchannel plate detectors with comparatively simple readout electronics is described. The goals of this study were to demonstrate the linearity of the mosaic anode algorithm, and to verify the predicted resolution performance in a realistic detector configuration. It is found that the nonlinearity introduced at the boundary between two anodes is limited to 50-100 microns. It is also shown that the spatial resolution of the detector is limited mainly by partition noise to about 35 microns (FWHM) at a gain of 2 x 10 to the 7th. A systematic investigation of the charge distribution arriving at the anode is also described. Using the relative charges arriving on the two anodes of the mosaic pattern, the detailed shape of the distribution and its dependence on MCP-anode voltage, MCP voltage, and pulse height are determined. A significant dependence of the profile on pulse height, which can introduce a pulse height dependence to the centroid calculation, particularly near the anode edges is found. Improved anode designs which will achieve the optimal performance are discussed.

Rasmussen, A.↗

Advances in photographic X-ray imaging for solar astronomy

The technique of obtaining quantitative data from high resolution soft X-ray photographic images produced by grazing incidence optics was successfully developed to a high degree during the AS&E Solar Research Sounding Rocket Program and the S-054 X-Ray Spectrographic Telescope Experiment Program on Skylab. Continued use of soft X-Ray photographic imaging in sounding rocket flights of the AS&E High Resolution Solar Soft X-Ray Imaging Payload has provided opportunities to further develop these techniques. The developments discussed include: (1) the calibration and use of an inexpensive, commercially available microprocessor controlled drum type film processor for photometric film development, (2) the use of Kodak Technical Pan 2415 film and Kodak SO-253 High Speed Holographic film for improved resolution, and (3) the application of a technique described by Cook, Ewing, and Sutton (1988) for determining the film characteristics curves from density histograms of the flight film. Although the superior sensitivity, noise level, and linearity of microchannel plate and CCD detectors attracts the development efforts of many groups working in soft X-ray imaging, the high spatial resolution and dynamic range as well as the reliability and ease of application of photographic media assures the continued use of these techniques in solar X-ray astronomy observations.

Moses, D.↗

New measurements of the far ultraviolet scattering properties of interstellar dust

An analysis is presented for the spectra of the diffuse ultraviolet background taken during shuttle flight STS-61C (January 1986). Eight regions of the sky were observed for approximately 20 minutes each, using a spectrograph designed specifically to perform measurements of the UV background. The field of view was 3.8 deg x 8 min, with imaging along the slit to confine stellar contamination. The instrument featured a shutter mechanism to measure internal background during flight, a low-scatter holographically ruled diffraction grating, photon counting microchannel plate detectors, through baffling, and a crystal window to further attenuate stray light. The spectra covered the range 1400 to 1850 A and was binned in 50 A bands. The procedure for substracting the contribution of stars too faint to be detected as discrete sources during the observations (in general this represents a small fraction of the total intensity detected except at the longest wavelengths). A radiative transfer model used to interpret the data and set confidence intervals on the relevant parameters is described. It was found that the continuum component of the diffuse ultraviolet background arises primarily from two sources. One source is scattering of starlight by interstellar dust with an albedo of about 12 percent and a relatively isotropic phase function. A second source consists of about 150 photons/cm/sec/ster/A of extragalactic light which is attenuated by the dust in the galaxy. Although emission features possibly associated with molecular H2 are detected in one look direction, fluorescence of H2 is not a major contributor to the diffuse UV background, at least at galactic latitudes greater than -10 degrees.

Hurwitz, Mark↗

An imaging system for PLIF/Mie measurements for a combusting flow

The equipment required to establish an imaging system can be divided into four parts: (1) the light source and beam shaping optics; (2) camera and recording; (3) image acquisition and processing; and (4) computer and output systems. A pulsed, Nd:YAG-pummped, frequency-doubled dye laser which can freeze motion in the flowfield is used for an illumination source. A set of lenses is used to form the laser beam into a sheet. The induced fluorescence is collected by an UV-enhanced lens and passes through an UV-enhanced microchannel plate intensifier which is optically coupled to a gated solid state CCD camera. The output of the camera is simultaneously displayed on a monitor and recorded on either a laser videodisc set of a Super VHS VCR. This videodisc set is controlled by a minicomputer via a connection to the RS-232C interface terminals. The imaging system is connected to the host computer by a bus repeater and can be multiplexed between four video input sources. Sample images from a planar shear layer experiment are presented to show the processing capability of the imaging system with the host computer.

Wey, C. C.↗

Rocket observations of the ultraviolet spectrum of comet Austin (1989c1)

Long slit ultraviolet spectra of Comet Austin (1989c1) were obtained from a sounding rocket experiment launched from White Sands Missile Range, New Mexico, on 21 April 1990 at 1015 UT. The instrument, known as the Faint Object Telescope, consisted of f/15.5 Dall-Kirkham telescope, a Rowland Circle spectrograph and a microchannel plate intensifier coupled to a Reticon diode array. An onboard television camera transmitted images to the ground during flight, which permitted real-time maneuvers in order to center the comet in the entrance slit. The comet was held near the center of the slit for approximately 270 seconds by sending six pointing corrections, all but one of which was less than 30 arcseconds. The comet's parameters at the time of observation, along with the characteristics of the instrument, are given.

Sahnow, D. J.↗

New high-resolution electrostatic ion mass analyzer using time of flight

The design of a high-resolution ion-mass analyzer is described, which is based on an accurate measurement of the time of flight (TOF) of ions within a region configured to produce a harmonic potential. In this device, the TOF, which is independent of ion energy, is determined from a start pulse from secondary electrons produced when the ion passes through a thin carbon foil at the entrance of the TOF region and at a stop pulse from the ion striking a microchannel plate upon exciting the region. A laboratory prototype instrument called 'VMASS' was built and was tested at the Goddard Space Flight Center electrostatic accelerator, showing a good mass resolution of the instrument. Sensors of the VMASS type will form part of the WIND Solar Wind and Suprathermal Ion experiment, the Soho mission, and the Advanced Composition Explorer.

Hamilton, D. C.↗

Extreme ultraviolet quantum detection efficiency of rubidium bromide opaque photocathodes

Measurements are presented of the quantum detection efficiency (QDE) of three samples of RbBr photocathode layers over the 44-150-A wavelength range. The QDE of RbBr-coated microchannel plate (MCP) was measured using a back-to-back Z-stack MCP configuration in a detector with a wedge and strip position-sensitive anode, of the type described by Siegmund et al. (1984). To assess the stability of RbBr layer, the RbBr photocathode was exposed to air at about 30 percent humidity for 20 hr. It was found that the QDE values for the aged cathode were within the QDE measurement errors of the original values. A simple QDE model was developed, and it was found that its predictions are in accord with the QDE measurements.

Siegmund, Oswald H. W.↗

Optical design of Lyman/FUSE

The optical system for the proposed Lyman/Far UV Spectroscopic Explorer (FUSE) orbiting observatory is described and illustrated with drawings and graphs of predicted performance. The system comprises (1) an FUV channel based on a 1.84-m-diameter Rowland circle spectrograph with five high-density modified ellipsiodal near-normal-incidence gratings and an array of four MAMA detectors; (2) an EUV channel with ellipsoidal mirror, planar varied-line-space grating, microchannel-plate array, and wedge-and-strip anode detector; (3) a 70-cm Wolter II glancing-incidence telescope; and (4) a CCD-detector fine-error sensor to provide accurate pointing (within 200 marcsec rms). The resolving powers of the spectrographs are 30,000 in the FUV and 300-600 (wavelength-dependent) in the EUV.

Content, D. A.↗

Report of the ultraviolet and visible sensors panel

In order to meet the science objectives of the Astrotech 21 mission set the Ultraviolet (UV) and Visible Sensors Panel made a number of recommendations. In the UV wavelength range of 0.01 to 0.3 micro-m the focus is on the need for large format high quantum efficiency, radiation hard 'solar-blind' detectors. Options recommended for support include Si and non-Si charge coupled devices (CCDs) as well as photocathodes with improved microchannel plate readouts. For the 0.3 to 0.9 micro-m range, it was felt that Si CCDs offer the best option for high quantum efficiencies at these wavelengths. In the 0.9 to 2.5 micro-m the panel recommended support for the investigation of monolithic arrays. Finally, the panel noted that the implementation of very large arrays will require new data transmission, data recording, and data handling technologies.

Timothy, J. Gethyn↗

Lidar receivers for picosecond remote sensing

The lidars of picosecond resolution are an attractive tool for remote probing of some highly dynamic objects like sea subsurface waters, small-scale turbulences in the atmosphere, etc. The picosecond lasers are suitable illuminating sources, but the main restrictions are due to the lack of proper receiving methods, combining the both high temporal and amplitude resolution, good sensitivity, short integration time, and wide dynamic range. The methods for short pulse measurements are not suitable for picosecond lidars, operating at low level, with highly dynamic signals. The streak-cameras are of high cost, lower sensitivity, and lower dynamic range (approximately 10(exp 3)). Because of the background, the single quantum regime in photomultipliers (PMT) is ineffective. The sampling of highly dynamic optical signals with resolution less than or equal to 1ns is a serious problem, limiting the application of the high speed PMT-MCP (microchannel plate) in the picosecond lidar systems. The goal of this work is to describe the use of a new photodetection technique which combines the picosecond resolution with the high amplitude resolution, dynamic range, and sensitivity.

Stoyanov, D. V.↗

The Berkeley EUV spectrometer for ORFEUS

A novel EUV spectrometer is presented for the ORFEUS-SPAS mission. It uses a set of four varied line-space spherical diffraction gratings to obtain high-resolution spectra of point sources at wavelengths between 390 and 1200 A. The spectra are recorded with two detector units, each containing curved-surface microchannel plates and a delay-line anode-readout system. An independent optical system detects the image of the source in the entrance aperture and tracks the source as it drifts during an observation, enabling a reconstruction of the spectra postflight. The overall system performance is discussed and illustrated by synthetic spectra.

Hurwitz, M.↗

Photoelectron energy spectra of opaque photocathodes in the extreme and far ultraviolet

Measurements of the EUV quantum detection efficiency (QDE) of opaque RbBr, CsBr, and KBr photocathodes are described and investigations of their photoemission characteristics over the 44-1560 A wavelength range are reported. The results show that high QDEs can be obtained in the EUV. Narrow QDE peaks at soft X-ray wavelengths occur at slightly different wavelengths for each of the materials studied. The long-wavelength thresholds vary according to the material band gap. Data on the photoemission from the photocathode layer on the microchannel plate interchannel web area are used to determine the number and energy distribution of the emitted photoelelectrons as a function of wavelength.

Siegmund, Oswald H. W.↗

An intensified CCD detector using the phosphor TPB

The Research Amplifying Imaging Detector consists of a microchannel plate image intensifier with a thin coating (3500-10,000 A) of the phosphor tetraphenyl-butadiene (TPB) on the entrance window to convert EUV radiation to visible, and coupled via a lens to a CCD detector. This design allows great flexibility in selecting the pixel size and field of view, with a simple mechanical design. The phosphor appears to be quite rugged, with no degradation having appeared during several months of testing both in and out of vacuum. Tests have been made at visible and EUV (304 A) wavelengths of the following performance aspects: EUV spectral sensitivity, spatial resolution (both of components and of the system as a whole), noise, linearity, and dynamic range. An improved detector for the Coronal Diagnostic Spectrometer experiment on the Solar Heliospheric Observatory satellite is being presently designed.

Thompson, William T.↗

Space astronomical telescopes and instruments; Proceedings of the Meeting, Orlando, FL, Apr. 1-4, 1991

The present volume on space astronomical telescopes and instruments discusses lessons from the HST, telescopes on the moon, future space missions, and mirror fabrication and active control. Attention is given to the in-flight performance of the Goddard high-resolution spectrograph of the HST, the initial performance of the high-speed photometer, results from HST fine-guidance sensors, and reconstruction of the HST mirror figure from out-of-focus stellar images. Topics addressed include system concepts for a large UV/optical/IR telescope on the moon, optical design considerations for next-generation space and lunar telescopes, the implications of lunar dust for astronomical observatories, and lunar liquid-mirror telescopes. Also discussed are space design considerations for the Space Infrared Telescope Facility, the Hubble extrasolar planet interferometer, Si:Ga focal-plane arrays for satellite and ground-based telescopes, microchannel-plate detectors for space-based astronomy, and a method for making ultralight primary mirrors.

Bely, Pierre Y.↗

Intensity distribution of the x ray source for the AXAF VETA-I mirror test

The X-ray generator for the AXAF VETA-I mirror test is an electron impact X-ray source with various anode materials. The source sizes of different anodes and their intensity distributions were measured with a pinhole camera before the VETA-I test. The pinhole camera consists of a 30 micrometers diameter pinhole for imaging the source and a Microchannel Plate Imaging Detector with 25 micrometers FWHM spatial resolution for detecting and recording the image. The camera has a magnification factor of 8.79, which enables measuring the detailed spatial structure of the source. The spot size, the intensity distribution, and the flux level of each source were measured with different operating parameters. During the VETA-I test, microscope pictures were taken for each used anode immediately after it was brought out of the source chamber. The source sizes and the intensity distribution structures are clearly shown in the pictures. They are compared and agree with the results from the pinhole camera measurements. This paper presents the results of the above measurements. The results show that under operating conditions characteristic of the VETA-I test, all the source sizes have a FWHM of less than 0.45 mm. For a source of this size at 528 meters away, the angular size to VETA is less than 0.17 arcsec which is small compared to the on ground VETA angular resolution (0.5 arcsec, required and 0.22 arcsec, measured). Even so, the results show the intensity distributions of the sources have complicated structures. These results were crucial for the VETA data analysis and for obtaining the on ground and predicted in orbit VETA Point Response Function.

Zhao, Ping↗

A Remote Laser-mass Spectrometer for Determination of Elemental Composition

Determination of the elemental composition of lunar, asteroid, and planetary surfaces is a major concern for science and resource utilization of space. The science associated with the development of a satellite or lunar rover laser-mass spectrometer instrument is presented here. The instrument would include a pulsed laser with sufficient energy to create a plasma on a remote surface. Ions ejected from this plasma travel back to the spacecraft or rover, where they are analyzed by a time-of-flight mass spectrometer, giving the elemental and isotope composition. This concept is based on the LIMA-D instrument on board the former Soviet Union Phobos-88 spacecraft sent to Mars. A laser-mass spectrometer placed on a rover or satellite would substantially improve the data return over alternative techniques. The spatial resolution would be centimeters, and a complete mass spectrum could be achieved in one laser shot. An experiment is described that demonstrates these features. A 400 mj Nd:YAG laser is focused, to an intensity of 10(exp 11) w/sq cm, onto a Al, Ag, Cu, Ge, or lunar simulant target. A plasma forms from which ions are ejected. Some of these ions travel down an 18-m evacuated flight tube to a microchannel plate detector. Alternatively, the ions are captured by an ion trap where they are stored until pulsed into a 1-m time-of-flight mass spectrometer, giving the elemental composition of the remote surface. A television camera monitors the plasma plume shape, and a photodiode monitors the temporal plasma emission . With this system, ions of Al, Ag, Cu, Ge, and lunar simulant have been detected at 18 m. The mass spectrum from the ion trap and 1-m time-of-flight tube will be presented.

Deyoung, R. J.↗