Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “methods: analytical methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Enter Gaussian Mixture Modeling Extensions for Improved False Discovery Rate Estimation in GC-MS Metabolomics

Identifying small molecules (e.g., metabolites) is key towards driving scientific advancement in metabolomics, and gas chromatography–mass spectrometry (GC-MS) is an analytic method that may be applied to facilitate this process. The typical GC-MS identification workflow involves quantifying the similarity of an observed sample spectrum and other features (e.g. retention index) to that of several references, noting the compound of the best-matching reference spectrum as the identified metabolite. While a deluge of similarity metrics exists, none characterize the error rate of generated identifications, thereby presenting an unknown risk of false identification or discovery. To quantify this unknown risk, we propose a model-based framework for estimating the false discovery rate (FDR) among a set of identifications. Extending the traditional mixture modeling framework, our method incorporates both similarity score and experimental information in estimating the FDR. We apply these models to identification lists derived from across 548 samples of varying complexity and sample type (e.g., fungal species, standard mixtures, etc.), comparing their performance to that of the traditional Gaussian mixture model (GMM). Through simulation, we additionally assess the impact of reference library size on the accuracy of FDR estimates. In comparing the best performing model extensions to the GMM, our results indicate relative decreases in median absolute estimation error (MAE) ranging from 12% to 70%, based on comparisons of the median MAEs across all hit-lists. Results indicate that these relative performance improvements generally hold despite library size, however FDR estimation error typically worsens as the set of reference compounds diminishes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining sulfur speciation in oxidatively crosslinked degradable polymers using sulfur K-edge X-ray absorption spectroscopy

A new family of water-degradable elastic polymers prepared by oxidative crosslinking of the parent polythionolactones shows promise in a broad range of applications, but the compositions of these materials elude conventional analytical methods. Here, in this work, we use sulfur K-edge X-ray absorption spectroscopy to quantify the amounts of thioether, disulfide, sulfone, sulfate ester, and thionoester in each polymer and to rule out the presence of several other functional groups, including sulfonate, thiosulfonate, sulfate, and sulfoxide. We rationalize this speciation as a function of linker flexibility in the context of sulfinyl cycloaddition reactions and propose a mechanism of aggregation for the oxidized polymers. Our results correlate with swelling ratios but not with porosity nor crosslink density measurements, demonstrating the importance of pairing mechanical and chemical techniques when characterizing heterogeneous organic polymers. Finally, we take advantage of the proximity of the gold M 4,5 -edges to the sulfur K-edge to analyze the binding and reactivity of Au(III) with the crosslinked polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LX-17 Thermal Decomposition-Characterization of Solid Residues from Cook-Off in a Small-Scale Vessel Under Confinement

Concerns surround whether insensitive (or any) energetic materials are more dangerous to handle when exposed to abnormal thermal environments. This study characterizes the residual material remaining after LX-17 (92.5 % 1,3,5-triamino 2,4,6-trinitro benzene (TATB) and 7.5 % Kel-F) is exposed to various thermal environments in a sealed small-scale vessel cook-off test reactor (heated at 0.1 to 100 °C/min until the reactor opened at 3000 psi (20.7 MPa)). Previous work has shown no additional sensitivity of these residues as evaluated by small-scale safety analysis, but characterization on the molecular scale indicates the TATB is transformed to more reactive compounds as well as the residue could be precursors to toxic gases. The solids and chars were characterized by various analytical methods. Heat-flow measurements indicated exothermic release is due to a mixture of residual TATB and related decomposition products (which may be more energetic). The N/C and O/N ratios indicated a material much more degraded than TATB. Primarily, the solids were a network of amorphous C inter-dispersed with N and O. Types of bonding include C–C, C–N, N–H, N–C, N=C, N≡C, C–O=, and –OH. Solvent extracts of the solids showed TATB decomposition intermediates benzo-furazans and benzo-furoxans, substituted TATB (mono-nitroso, hydroxyl, and chlorinated) along with several unidentified smaller molecules. These results indicate thermal treatment produces an amorphous carbon residue with heteroatoms incorporated through differing functionality, varying depending upon the thermal severity of exposure. These structures also could further decompose producing toxic light gases (such as cyanide).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Measurements of Dimethyl Sulfide Oxidation Chemistry: Uncovering the Primary Pathways from Gas Phase to Sulfate Aerosols

We report experimental measurements of dimethyl sulfide oxidation, focusing on a major chemical intermediate, hydroperoxymethyl thioformate (HPMTF). The (photo)chemistry and transport properties of HPMTF, which are critical to accurate modeling of tropospheric sulfur, are not known, partly because current analytical methods are not optimized for elusive chemical intermediates. We investigated dimethyl sulfide oxidation using a custom time-resolved photoionization mass spectrometer, interfaced with pulsed laser photolysis, continuous photolysis, and liquid droplet reactors. We detected and characterized HPMTF (along with other reaction intermediates), quantified its yield, and measured its formation rate coefficient. We also developed a clean, intense, online HPMTF source, suitable for further experimental investigations. Lastly, we measured the mass accommodation coefficient of HPMTF on water droplets – a critical quantity for modeling its atmospheric partitioning between the gas and condensed phases. The experimental platform we developed here enables the exploration of other critical elusive reaction intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cathodic NH 4 + leaching of nitrogen impurities in CoMo thin-film electrodes in aqueous acidic solutions

Electrocatalytic reduction of dinitrogen (N 2 ) to ammonium (NH 4 + ) in acidic aqueous solutions was investigated at ambient temperature and pressure using a cobalt–molybdenum (CoMo) thin-film electrode prepared by magnetron reactive sputtering. Increased concentrations of ammonium ions (NH 4 + ) were consistently detected in the electrolyte using ion chromatography (IC) after constant-potential electrolysis at various potentials (≤-0.29 V vs. RHE). Using a newly developed analytical method based on ammonia derivatization, performing the experiments with 15 N 2 -labelled gas led however to the detection of increased 14 NH 4 + concentrations instead of 15 NH 4 + . X-ray photoelectron spectroscopic (XPS) analysis of the electrode surface revealed the presence of Mo[triple bond, length as m-dash]N and Mo–NH x species. Several contamination sources were identified that led to substantial increases in the concentration of ammonium ions, including 15 NH 3 impurities in 15 N 2 gas. The observed ammonium concentrations can be consistently ascribed to leaching of nitrogen ( 14 N) impurities incorporated in the CoMo film during the sputtering process. Therefore, researchers in the field are urged to adopt extended protocols to identify and eliminate sources of ammonia contamination and to very carefully monitor the ammonium concentrations in each experimental step.

36 MATERIALS SCIENCE↗

Towards a heat- and mass-balanced kinetic model of TATB decomposition

We report TATB (1,3,5-triamino-2,4,6-trinitrobenzene) was thermally degraded by two small-scale analytical methods – simultaneous differential scanning calorimetry and thermogravimetric analysis (SDT) and a hot-stage microscope with Fourier Transform Infrared (FTIR) analysis capabilities. SDT used ramped heating, isothermal soaking, and thermal pretreatment at various conditions. The heat flow and mass loss were monitored during various treatment conditions to derive chemical decomposition kinetics and Arrhenius parameters. FTIR experiments used isothermal heating, and changes were monitored spectroscopically. Solid samples generated at specific conditions were collected from both methods and were analyzed by DMSO extraction followed by chemical speciation by optical and mass spectrometric methods. Characterization provided the following reaction insights: TATB decreases in a sigmoidal pattern in isothermally heated samples. Other soluble products gradually increase in concentration and then abruptly decline in concentration during the second exotherm, such as diamino-dinitro-benzofurazan and amino-nitro-benzodifurazan. FTIR showed gradual changes in the amino and nitro functionality, shifting positions and decreasing intensity for the first 40 min. Then the solid gradually appeared more like an amorphous C with N incorporated, similar to previous studies on thermally degraded TATB-type materials. Extracted residues (DMSO-soluble components removed) examined by FTIR showed an abrupt change in chemical composition between 40- and 45-min isothermal treatment, indicating early forming solids are different than later forming residues. A reliable mass- and energy-balanced global reaction network must include at least two autocatalytic reactions, either in parallel or series, and at least one must have an explicit initiation reaction having a low activation energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revisiting the K-edge X-ray absorption fine structure of Si, Ge–Si alloys, and the isoelectronic series: CuBr, ZnSe, GaAs, and Ge

Extended X-ray absorption fine structure (EXAFS) has evolved into an unprecedented local-structure technique that is routinely used to study materials’ problems in the biological, chemical, and physical sciences. Like many other experimental techniques, EXAFS also requires that several key atomic parameters must be known a priori before structural information can be quantitatively determined. Utilizing current analytical methods, we revisit the isoelectronic series CuBr, ZnSe, GaAs, and Ge originally studied by Stern et al. during the early development of EXAFS. We demonstrate that the ab initio EXAFS code FEFF accurately predicts the atomic phase shifts and backscattering amplitudes that are primarily functions of the sum of atomic numbers Z along an EXAFS scattering path. We also investigate quantitative fitting and first- and second-shell phase transferability together with problems that arise if a backscattering atom is identified incorrectly in an EXAFS fitting model. Features in the near-edge region, on the other hand, are shown to require a comprehensive treatment of the band structure and density-of-states, including effects of the screened Coulomb interaction between the photoelectron and core hole. Here, we demonstrate that the Bethe–Salpeter equation (BSE) accurately captures the NEXAFS (or XANES) portion of the spectrum for the isoelectronic series in addition to Si and Ge–Si alloys, including within a few eV of the absorption edge, where band structure and excitonic effects are most important.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An initial investigation of accuracy required for the identification of small molecules in complex samples using quantum chemical calculated NMR chemical shifts

The majority of primary and secondary metabolites in nature have yet to be identified, representing a major challenge for metabolomics studies that currently require reference libraries from analyses of authentic compounds. Using currently available analytical methods, complete chemical characterization of metabolomes is infeasible for both technical and economic reasons. For example, unambiguous identification of metabolites is limited by the availability of authentic chemical standards, which, for the majority of molecules, do not exist. Computationally predicted or calculated data are a viable solution to expand the currently limited metabolite reference libraries, if such methods are shown to be sufficiently accurate. For example, determining nuclear magnetic resonance (NMR) spectroscopy spectra in silico has shown promise in the identification and delineation of metabolite structures. Many researchers have been taking advantage of density functional theory (DFT), a computationally inexpensive yet reputable method for the prediction of carbon and proton NMR spectra of metabolites. However, such methods are expected to have some error in predicted 13 >C and 1 H NMR spectra with respect to experimentally measured values. This leads us to the question–what accuracy is required in predicted 13 C and 1 H NMR chemical shifts for confident metabolite identification? Using the set of 11,716 small molecules found in the Human Metabolome Database (HMDB), we simulated both experimental and theoretical NMR chemical shift databases. We investigated the level of accuracy required for identification of metabolites in simulated pure and impure samples by matching predicted chemical shifts to experimental data. We found 90% or more of molecules in simulated pure samples can be successfully identified when errors of 1 H and 13 C chemical shifts in water are below 0.6 and 7.1 ppm, respectively, and below 0.5 and 4.6 ppm in chloroform solvation, respectively. In simulated complex mixtures, as the complexity of the mixture increased, greater accuracy of the calculated chemical shifts was required, as expected. However, if the number of molecules in the mixture is known, e.g., when NMR is combined with MS and sample complexity is low, the likelihood of confident molecular identification increased by 90%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emerging Electrochemical Techniques for Probing Site Behavior in Single-Atom Electrocatalysts

Single-atom catalysts (SACs) have aroused tremendous interest over the past decade, particularly in the community of energy and environment-related electrocatalysis. A rapidly growing number of recent publications have recognized it as a promising candidate with maximum atomic utilization, distinct activity, and selectivity in comparison to bulk catalysts and nanocatalysts. However, the complexity of localized coordination environments and the dispersion of isolated sites lead to significant difficulties when it comes to gaining insight into the intrinsic behavior of electrocatalytic reactions. Furthermore, the low metal loadings of most SACs make conventional ensemble measurements less likely to be accurate on the subnanoscale. Thus, it remains challenging to probe the activity and properties of individual atomic sites by available commercial instruments and analytical methods. In spite of this, continuing efforts have lately focused on the development of advanced measurement methodologies, which are very useful to the fundamental understanding of SACs. There have recently been a number of in situ/operando techniques applied to SACs, such as electron microscopy, spectroscopy, and other analysis methods, which support relevant functions to identify the active sites and reaction intermediates and to investigate the dynamic behavior of localized structures of the catalytic sites. This Account aims to present recent electrochemical probing techniques which can be used to identify single-atomic catalytic sites within solid supports. First, we describe the basic principles of molecular probe methods for the study and analysis of electrocatalytic site behavior. In particular, the in situ probing technique enabled by surface interrogation scanning electrochemical microscopy (SISECM) can measure the active site density and kinetic rate with high resolution. An alternative electrochemical probing technique is further demonstrated on the basis of single-entity electrochemistry, which allows the unique electrochemical imaging of the size and catalytic rate of single atoms, molecules, and clusters. Next, the merits and limitations of different electrochemical techniques are then discussed, along with perspectives for future prospects. Apart from this, we further showcase the powerful capability of emerging electrochemical probing techniques for determining significant effects and properties of SACs for various electrocatalytic reactions, including oxygen reduction and evolution, hydrogen evolution, and nitrate reduction. Overall, electrochemical techniques with atomic resolution have greatly increased opportunities for observing, measuring, and understanding the surface and interface chemistry during energy conversion. In the future, it is anticipated that the development of electrochemical probing techniques will be advanced with innovative perspectives on the behavior and features of SACs. We hope that this Account can contribute in several ways to promoting the fundamental knowledge and technical progress of emerging electrochemical measurements for studying SACs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffusion power spectra as a window into dynamic materials architecture

Chemical recycling of commodity and specialty polymers presents a multifaceted challenge for industrial societies. On one hand, macromolecular architectures must be engineered to yield durable products that, on the other hand, rapidly deconstruct to recyclable monomers under pre-determined conditions. Polymer deconstruction is a chemical process that requires deep understanding of molecular reactivity in heterogeneous media, where porous material architectures evolve in both space and time. To build this understanding, we develop herein experimental and analytical methods describing sets of diffusive eigenmodes that exist within time-varying, non-Euclidean boundary conditions, a situation commonly encountered in the reactive deconstruction of polymers where chain fragments splay, alter their local dynamics, and evolve in their confinement of reacting media. Diffusion power spectra, discerned experimentally by NMR, yield polymer and solvent frequency-domain velocity autocorrelation functions that are analyzed in the context of physical models for chemical reactions parameterized with fractal mathematics. The results connect local motion in polymers to chemical reactivity during acidolysis of circular elastomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical considerations for amino acid isotope analysis

Over the last few decades, isotopic analysis of amino acids at the compound- and position-specific levels has been rapidly advancing across diverse fields. As these techniques progress, evaluation of isotopic fractionation associated with sample workup is essential. This critical review of analytical methods through the lens of isotope geochemistry provides a benchmark for researchers across disciplines seeking to make compound- and position-specific amino acid isotope measurements. We focus on preparation, acid hydrolysis, clean-up, derivatization, separation, and C, H, N, and S isotope measurement. Despite substantial customizability across these steps, the following general recommendations should maximize recovery while minimizing isotopic fractionation. Samples should be freeze-dried and stored anoxically at ≤ –20 °C prior to conventional acid hydrolysis (6N HCl, 110 °C, 20–24 h, anoxic), which suffices for many residues. Both gas and liquid chromatographic (GC and LC, respectively) techniques are well-established and separate about 15 amino acids; LC bypasses the need for derivatization, while GC provides higher sensitivity. Furthermore, when derivatization is needed, n-acetyl and alkoxycarbonyl esters provide the most reproducible C isotope ratios. For compound-specific analyses, online GC–IRMS and LC–IRMS systems offer the easiest workflow, but EA–IRMS enables potential multi-element isotope analysis. Emerging techniques like high-resolution mass spectrometry are also promising for multi-element analysis and recover position-specific isotopic information. Looking forward to the next decade of innovation, isotope geochemists and ecologists can improve amino acid isotope analysis by focusing on streamlining multi-element analysis and standardizing calibration practices across laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of carbonyldiimidazole as a derivatization agent for the detection of pinacolyl alcohol, a forensic marker for Soman, by EI-GC–MS and LC-HRMS in official OPCW proficiency test matrices

Pinacolyl alcohol (PA), a key forensic marker for the nerve agent Soman (GD), is a particularly difficult analyte to detect by various analytical methods. In this work, we have explored the reaction between PA and 1,1'-carbonyldiimidazole (CDI) to yield pinacolyl 1H-imidazole-1-carboxylate (PIC), a product that can be conveniently detected by gas chromatography–mass spectrometry (GC–MS) and liquid chromatography-high-resolution mass spectrometry (LC-HRMS). Regarding its GC–MS profile, this new carbamate derivative of PA possesses favorable chromatographic features such as a sharp peak and a longer retention time (RT = 16.62 min) relative to PA (broad peak and short retention time, RT = 4.1 min). Additionally, the derivative can also be detected by LC-HRMS, providing an avenue for the analysis of this chemical using this technique where PA is virtually undetectable unless present in large concentrations. From a forensic science standpoint, detection of this low molecular weight alcohol signals the past or latent presence of the nerve agent Soman (GD) in a given matrix (i.e., environmental or biological). The efficiency of the protocol was tested separately in the analysis and detection of PA by EI-GC–MS and LC-HRMS when present at a 10 μg/mL in a soil matrix featured in the 44th PT and in a glycerol-rich liquid matrix featured in the 48th Official Organization for the Prohibition of Chemical Weapons (OPCW) Proficiency Test when present at a 5 μg/mL concentration. In both scenarios, PA was successfully transformed into PIC, establishing the protocol as an additional tool for the analysis of this unnatural and unique nerve agent marker by GC–MS and LC-HRMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid and Simultaneous Characterization of Drug Conjugation in Heavy and Light Chains of a Monoclonal Antibody Revealed by High-Resolution Ion Mobility Separations in SLIM

Antibody-drug conjugates (ADCs) have recently gained traction in the biomedical community due to their promise for human therapeutics and an alternative to chemotherapy for cancer. Crucial metrics for ADC efficacy, safety, and selectivity are their drug-antibody ratios (DARs). However, DAR characterization (i.e., determining the average number of conjugated drugs on the antibody) through analytical methods remains challenging due to the heterogeneity of drug conjugation as well as the numerous post-translational modifications possible in the monoclonal antibody. In this work, we report on the use of high-resolution ion mobility spectrometry separations in our structures for lossless ion manipulations coupled to mass spectrometry (SLIM IMS-MS) platform for the rapid and simultaneous characterization of the drug load profile (i.e., stoichiometric distribution of the number of conjugated drugs present on the mAb), determination of the weighted average DAR in both the heavy and light chains of a model antibody-drug conjugate, and calculation of the overall DAR of the ADC. After chemical reduction of the ADC and a subsequent 31.5 meter SLIM IMS separation the various drug bound antibody species could be well resolved for both chains. Furthermore, we also show that higher resolution separations were possible with SLIM IMS as compared to ones performed on a commercially available (~1 meter) drift tube IMS-MS platform. Interestingly, additional gas-phase substructures become evident with longer path length SLIM IMS, potentially providing insight related to how drug conjugation may alter the structural properties of a monoclonal antibody and thus affect its overall potency and/or selectivity for a given antigen. We expect high-resolution SLIM IMS separations will augment the existing toolbox for ADC characterization, particularly for structural confirmation to enable the rapid optimization of DAR for a given ADC and thus better understand its potential toxicity and potency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbonation of Alkaline Earth Metal Hydroxides: Structure across Nano- to Mesoscales

The conversion of gaseous CO 2 into a solid constitution through mineralization is an active area of carbon capture, and alkaline earth metal hydroxides (M(OH) 2 , M = Ca 2+ , Mg 2+ ) are frontrunners in this area. As model systems, nanolime samples are excellent templates for the study of this reaction. Here, we have examined these under ambient pressure conditions with controlled humidity and CO 2 . Utilizing a broad range of analytical methods, we first established the purity and structures of the selected materials. We then examined the structural changes due to carbonation, using infrared spectroscopy, X-ray scattering, and neutron scattering. The resulting structural changes are resolved from nanoscale to mesoscale and from early-stage to late-stage carbonation. Ca(OH) 2 and Mg(OH) 2 are found to behave quite differently. As expected from prior work, the carbonation of Ca(OH) 2 is kinetically favored. Further, our structure studies suggest this is due to a facile reaction at the fractal interface of the particles. From early- to late-stage carbonation, there is a consistent increase in the fractal roughness. This is in contrast to Mg(OH) 2 where the same surface evolves into a smooth conformal coating. For this material the major reacting component is at the mesoscale, suggesting globular particle growth or evolving macro-porosity. Because neutron scattering is sensitive to hydrogen content, we expected a significant change as M(OH) 2 evolves to MCO 3 . Such a change is found for Ca(OH) 2 but not for Mg(OH) 2 , providing evidence for the formation of hydrated carbonates for the later material. The formation of a conformal layer along with water-rich carbonate formation is an impediment to the use of Mg(OH) 2 for carbon capture. For energy-efficient carbon capture, it would be desirable to enhance carbonation rates for Mg(OH) 2 , and one possible route would be the use of anhydrous fluids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Archaeal protein containing domain of unknown function 2193 undergoes oligomeric reconfiguration upon iron–sulfur cluster binding

Methanogenic archaea are particularly rich in iron–sulfur proteins, yet their roles remain largely enigmatic. Here, we characterized aMethanococcus voltae(Mvo) protein from the domain of unknown function (DUF) 2193 family, a group of proteins present primarily in archaea and characterized by a conserved cysteine‐rich C‐terminal motif.MvoDUF2193 was heterologously expressed and characterized by a range of spectroscopic and analytical methods. The results demonstrate thatMvoDUF2193 binds a single [4Fe–4S] cluster per subunit and that cluster occupancy regulates the transition from an apo tetramer to a [4Fe–4S] monomeric form. We hypothesize thatMvoDUF2193 serves a regulatory role in the cell, mediated by [Fe–S] cluster binding and changes in oligomeric state.

Biochemistry & Molecular Biology↗

Development of Cr, Se, U, Sb, and Te isotopes as indicators of redox reactions, contaminant fate, and contaminant transport in aqueous systems: A review

Cr, Se, U, Sb, and Te are toxic, redox-active elements that are more mobile and environmentally problematic in their oxidized forms, and less mobile and bioavailable in their reduced forms. This chapter reviews the development of Cr, Se, U, Sb, and Te isotope ratio measurements as new indicators of redox reactions and contaminant migration. Reliable analytical methods exist, but are still evolving. Understanding of isotopic fractionation induced by various (bio)geochemical processes has been explored in dozens of publications, yet is far from complete: Reduction reactions, the major driver of isotopic variation, have been relatively well studied. However, the magnitude of fractionation is variable and the systematics of that variation are still being explored. Isotopic fractionation induced by oxidation reactions is not well understood. Non-redox reactions, which involve smaller changes in bonding of these elements, tend to induce less isotopic fractionation, but can nonetheless cause significant isotopic shifts. Field applications of Cr, Se, U isotope ratios have demonstrated that they are useful as indicators of reduction in natural systems. A few studies suggest they are also useful as indicators of oxidation and contaminant sources. The physical and chemical complexity of groundwater systems hinders accurate quantitative interpretation of Cr, Se, U isotope data using simple models. Numerical models have been developed that capture the behavior of complex, coupled systems and enable the most effective extraction of information from field data sets.

58 GEOSCIENCES↗

Scalable Layer-by-Layer Electrospray-Assisted Interfacial Polymerization: Enabling Large-Area Polyamide Membrane Fabrication

Layer-by-layer electrospray-assisted interfacial polymerization (LBL-EAIP) has recently been proposed as an alternative approach for fabricating polyamide membranes with precisely controlled thickness and polymerization degree, showing great potential for reverse osmosis (RO) membrane synthesis. In this article, we report a scale-up strategy for LBL-EAIP to enable its practical application in RO membrane manufacturing. A multi-jet electrospray apparatus was developed, and the device configuration and process parameters were carefully adjusted to produce polyamide-on-polyethersulfone thin film composite (TFC) membranes with consistently high salt rejection and water permeance across the membrane area. Specifically, an average 97.1% NaCl rejection from a 2000 ppm NaCl feed was achieved with an area-to-area deviation of 1%, along with a deionized water permeance of 0.90 ± 0.11 LMH/bar at 15 bar feed pressure. In addition, a Fourier-transform infrared spectroscopy (FTIR)-based analytical method was developed for semi-quantitative assessment of membrane thickness and compositional uniformity, enabling rapid mapping of film microstructure and chemical variations. This work provides a pathway to scale up LBL-EAIP technology, bridging the gap between laboratory-scale innovation and industrial-scale manufacturing.

Feng, Yue (ORCID:0000000221343980)↗