Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Electrode erosion in steady-state electric propulsion engines

The anode and cathode of a 30 kW class arcjet engine were sectioned and analyzed. This arcjet was operated for a total time of 573 hr at power levels between 25 and 30 kW with ammonia at flow rates of 0.25 and 0.27 gm/s. The accumulated run time was sufficient to clearly establish erosion patterns and their causes. The type of electron emission from various parts of the cathode surface was made clear by scanning electron microscope analysis. A scanning electron microscope was used to study recrystallization on the hot anode surface. These electrodes were made of 2 percent thoriated tungsten and the surface thorium content and gradient perpendicular to the surfaces was determined by quantitative microprobe analysis. The results of this material analysis on the electrodes and recommendations for improving electrode operational life time are presented.

Pivirotto, Thomas J.↗

Strength of tantalum to 276 GPa determined by two x-ray diffraction techniques using diamond anvil cells

Tantalum (Ta) is a metal that has useful properties that make it useful in extreme environments. It is therefore important to understand how Ta performs in such extreme conditions by accurately measuring its properties. In this work, the yield strength of tantalum has been measured at pressures up to 276 GPa using axial and radial x-ray diffraction (XRD) methods in diamond anvil cells (DAC). We measured strength using XRD in a radial DAC to 50 GPa, in an axial DAC to 60 GPa using diamonds with standard flat culets, and in a final experiment to 276 GPa using toroidal diamond anvils. The radial XRD data were refined using the Material Analysis Using Diffraction (MAUD) Rietveld software package to extract lattice strain and the yield strength. The axial data were refined using the General Structure Analysis System (GSAS) II and a linewidth method was used to calculate the yield strength. The yield strength measured near ambient pressure was found to be 0.5 GPa and increased with pressure up to 50 GPa, where the yield strength plateaued at a value of 2.4 GPa. At pressures above 60 GPa, the strength increased again to a maximum value of 9 GPa at the highest pressure of 276 GPa. Here, the data from the three experiments show good agreement between the methods and previously reported experimental data. This agreement illustrates the value of axial diffraction data for material strength determination and allows for measurements at multihundreds of GPa using toroidal DACs.

36 MATERIALS SCIENCE↗

Structural analysis of bioceramic materials for denture application

Structural analysis has been performed on bioceramic materials for denture application by using X-ray diffraction (XRD), X-ray fluorescence (XRF), and Scanning Electron Microscopy (SEM). XRF is using for analysis chemical composition of raw materials. XRF shows the ratio 1 : 1 : 1 : 1 between feldspar, quartz, kaolin and eggshell, respectively, resulting composition CaO content of 56.78 %, which is similar with natural tooth. Sample preparation was carried out on temperature of 800 °C, 900 °C and 1000 °C. X-ray diffraction result showed that the structure is crystalline with trigonal crystal system for SiO{sub 2} (a=b=4.9134 Å and c=5.4051 Å) and CaH{sub 2}O{sub 2} (a=b=3.5925 Å and c=4.9082 Å). Based on the Scherrer’s equation showed the crystallite size of the highest peak (SiO{sub 2}) increase with increasing the temperature preparation. The highest hardness value (87 kg/mm{sup 2}) and match with the standards of dentin hardness. The surface structure was observed by using SEM also discussed.

36 MATERIALS SCIENCE↗

Application of the cubic polynomial strength criterion to the failure analysis of composite materials

A comparative failure analysis is presented based on the application of quadratic and cubic forms of the tensor polynomial lamina strength criterion to various composite structural configurations in a plane stress state. Failure loads have been predicted for off-angle laminates under simple loading conditions and for symmetric-balanced laminates subject to varying degrees of biaxial tension, including configurations subject to multimode failures. Some experimental data are also provided to support these calculations. From these results, the necessity of employing a cubic strength criterion to accurately predict the failure of composite laminae is demonstrated.

Tennyson, R. C.↗

Analytical Chemistry Laboratory

The Analytical Chemistry and Material Development Group maintains a capability in chemical analysis, materials R&D failure analysis and contamination control. The uniquely qualified staff and facility support the needs of flight projects, science instrument development and various technical tasks, as well as Cal Tech.

chemical analysis↗

Thermal Analysis and Testing of Candidate Materials for PAIDAE Inflatable Aeroshell

The Program to Advance Inflatable-Decelerators for Atmospheric Entry (PAIDAE) is a NASA project tasked with developing and evaluating viable inflatable-decelerator aeroshell geometries and materials. Thermal analysis of material layups supporting an inflatable aeroshell was completed in order to identify expected material response, failure times, and to establish an experimental test matrix to keep barrier layer materials from reaching critical temperature limits during thermal soak. Material layups were then tested in the 8- foot High Temperature Tunnel (8'HTT), where they were subjected to hypersonic aerothermal heating conditions, similar to those expected for a Mars entry. This paper presents a broad overview of the thermal analysis supporting multiple materials, and layup configurations tested in the 8'HTT at flight conditions similar to those that would be experienced during Mars entry trajectories. Direct comparison of TPS samples tested in the 8'HTT verify that the thermal model accurately predicted temperature profiles when there are up to four materials in the test layup. As the number of material layers in each test layup increase (greater than 4), the accuracy of the prediction decreases significantly. The inaccuracy of the model predictions for layups with more than four material layers is believed to be a result of the contact resistance values used throughout the model being inaccurate. In addition, the harsh environment of the 8'HTT, including hot gas penetrating through the material layers, could also be a contributing factor.

DelCorso, Joseph A.↗

FEAMAC-CARES Software Coupling Development Effort for CMC Stochastic-Strength-Based Damage Simulation

Reported here is a coupling of two NASA developed codes: CARES (Ceramics Analysis and Reliability Evaluation of Structures) with the MACGMC composite material analysis code. The resulting code is called FEAMACCARES and is constructed as an Abaqus finite element analysis UMAT (user defined material). Here we describe the FEAMACCARES code and an example problem (taken from the open literature) of a laminated CMC in off-axis loading is shown. FEAMACCARES performs stochastic-strength-based damage simulation response of a CMC under multiaxial loading using elastic stiffness reduction of the failed elements.

Reliability↗

CDB-AP: An application for coincidence Doppler broadening spectroscopy analysis

Coincidence Doppler Broadening (CDB) Positron Annihilation Spectroscopy (PAS) is a material analysis technique that can be used to non-destructively measure characteristics of structural defects in samples. Analyzing and comparing large datasets obtained using this technique, however, can be complicated and time intensive. The Coincidence Doppler Broadening Analysis Program (CDB-AP) is a graphical user interface that facilitates rapid analysis of many data files while using transparent processes. It is already used in three laboratories at Idaho National Laboratory and can be used in laboratories worldwide.

36 MATERIALS SCIENCE↗

Nondestructive Testing As a Tool in the Space Shuttle Columbia Accident Investigation

Nondestructive testing (NDT) played a crucial role in determining the Columbia tragedy's cause. Over 84,000 pieces of debris were recovered; hundreds were subsequently subjected to NDT and materials analysis. Visual NDT of the debris revealed localized areas of damage such as erosion, excessive heating, knife edging and mechanical damage. Three-dimensional reconstructions were made of the left wing leading edge, utilizing a tripod-mounted laser scanning head and focused laser beam, and an advanced topometric optical scanner (ATOS) with digital white light to scan complex-shaped debris, producing monochrome 3-D models. Texture mapping provided a means to capture true colors of the debris and superimpose them on the scanned images. Uniform deposits were found over large portions of debris, obscuring underlying materials. To determine what was beneath, inverse radiography was enlisted. The radiographs guided investigators to where samples should be taken. To ascertain compositions, these samples were subjected to analytical testing, including energy dispersive X-ray spectroscopy and electron microprobe analysis. This combination of visual evidence, radiography, virtual reconstruction, and materials analysis allowed the forensic scientists to verify that a breach occurred in the leading edge of the left wing, the path the plasma followed, and the sequence of events that led to the loss.

McDanels, Steve↗

Bayesian Inference and the Effects of Varying Uncertainty Models in Charring Ablator Calibration and Uncertainty Quantification Problems

The Mars Science Laboratory (MSL) vehicle utilized a heat shield constructed from NASA’s Phenolic-Impregnated Carbon Ablator (PICA) material to protect the main structure from the high enthalpy environment encountered during hypersonic atmospheric entry. During the vehicle’s descent through Martian atmosphere, multiple thermocouples embedded within the heat shield captured in-depth material temperature data that allow for studies to be conducted on current material response reconstruction tools. In the present work, material temperature data obtained from thermocouples within the MISP-4 plug (MEDLI (Mars Science Laboratory Entry, Descent, and Landing Instrument) Integrated Sensor Plug) are utilized in the calibration of Theoretical Ablative Composite for Open Testing (TACOT) model parameters in conjunction with NASA’s Porous material Analysis Toolbox (PATO) through Bayesian inference where uncertainty due to parametric, modeling, and experimental sources is simultaneously quantified. Prior to the study, a sensitivity analysis is performed through computation of the robust Sobol indices in an effort to study the relationship between input space and model response and to reduce the dimensionality of the statistical inverse problem. The Bayesian inference methodology necessitates an a-priori choice to be made for the uncertainty model for which numerous possibilities are available. Across most works, however, only basic additive or multiplicative models are utilized with pre-defined magnitudes of uncertainty based on a-priori knowledge or to-be-calibrated multipliers of static covariance matrix structures. The present effort explores the effects of informed uncertainty models, ones with temporal dependence that are simultaneously calibrated through Bayesian inference, on calibrated results for parameters that make up the uncertain input space.

Sensitivity Analysis↗

Effects of T-tabs and large deflections in double cantilever beam specimen tests

A simple strength of materials analysis was developed for a double-cantilever beam (DCB) specimen to account for geometric nonlinearity effects due to large deflections and T-tabs. A new DCB data analysis procedure was developed to include the effects of these nonlinearities. The results of the analysis were evaluated by DCB tests performed for materials having a wide range of toughnesses. The materials used in the present study were T300/5208, IM7/8551-7, and AS4/PEEK. Based on the present analysis, for a typical deflection/crack length ratio of 0.3 (for AS4/PEEK), T-tabs and large deflections cause a 15 and 3 percent error, respectively, in the computer Mode I strain energy release rate. Design guidelines for DCB specimen thickness and T-tab height were also developed in order to keep errors due to these nonlinearities within 2 percent. Based on the test results, for both hinged and tabbed specimens, the effects of large deflection on the Mode I fracture toughness (G sub Ic) were almost negligible (less than 1 percent) in the case of T300/5208 and IM7/8551-7; however, AS4/PEEK showed a 2 to 3 percent effect. The effects of T-tabs G sub Ic were more significant for all the materials with T300/5208 showing a 5 percent error, IM7/8551-7 a 15 percent error, and, AS4/PEEK a 20 percent error.

Naik, Rajiv A.↗

Effects of T-tabs and large deflections in DCB specimen tests

A simple strength of materials analysis was developed for a double-cantilever beam (DCB) specimen to account for geometric nonlinearity effects due to large deflections and T-tabs. A new DCB data analysis procedure was developed to include the effects of these nonlinearities. The results of the analysis were evaluated by DCB tests performed for materials having a wide range of toughnesses. The materials used in the present study were T300/5208, IM7/8551-7, and AS4/PEEK. Based on the present analysis, for a typical deflection/crack length ratio of 0.3 (for AS4/PEEK), T-tabs and large deflections cause a 15 percent and 3 percent error, respectively, in the computer Mode 1 strain energy release rate. Design guidelines for DCB specimen thickness and T-tab height were also developed in order to keep errors due to these nonlinearities within 2 percent. Based on the test results, for both hinged and tabbed specimens, the effects of large deflection on the Mode 1 fracture toughness (G sub Ic) were almost negligible (less than 1 percent) in the case of T300/5208 and IM7/8551-7; however, AS4/PEEK showed a 2 to 3 percent effect. The effects of T-tabs G sub Ic were more significant for all the materials with T300/5208 showing a 5 percent error, IM7/8551-7 a 15 percent error, and, AS4/PEEK a 20 percent error.

Naik, R. A.↗

Computational mechanics - Advances and trends; Proceedings of the Session - Future directions of Computational Mechanics of the ASME Winter Annual Meeting, Anaheim, CA, Dec. 7-12, 1986

The papers contained in this volume provide an overview of the advances made in a number of aspects of computational mechanics, identify some of the anticipated industry needs in this area, discuss the opportunities provided by new hardware and parallel algorithms, and outline some of the current government programs in computational mechanics. Papers are included on advances and trends in parallel algorithms, supercomputers for engineering analysis, material modeling in nonlinear finite-element analysis, the Navier-Stokes computer, and future finite-element software systems.

Noor, Ahmed K.↗

Quantifying and Addressing the DOE Material Reactivity Requirements with Analysis and Testing of Hydrogen Storage Materials & Systems

The objective of this project is to examine safety aspects of candidate hydrogen storage materials and systems being developed in the DOE Hydrogen Program. As a result of this effort, the general DOE safety target will be given useful meaning by establishing a link between the characteristics of new storage materials and the satisfaction of safety criteria. This will be accomplished through the development and application of formal risk analysis methods, standardized materials testing, chemical reactivity characterization, novel risk mitigation approaches and subscale system demonstration. The project also will collaborate with other DOE and international activities in materials based hydrogen storage safety to provide a larger, highly coordinated effort.

08 HYDROGEN↗

Combined elemental and microstructural analysis of genuine and fake copper-alloy coins

Innovative noninvasive material analysis techniques are applied to determine archaeometallurgical characteristics of copper-alloy coins from Florence's National Museum of Archaeology. Three supposedly authentic Roman coins and three hypothetically fraudolent imitations are thoroughly investigated using laser-induced plasma spectroscopy and time of flight neutron diffraction along with 3D videomicroscopy and electron microscopy. Material analyses are aimed at collecting data allowing for objective discrimination between genuine Roman productions and late fakes. The results show the mentioned techniques provide quantitative compositional and textural data, which are strictly related to the manufacturing processes and aging of copper alloys. (laser applications)

36 MATERIALS SCIENCE↗

Smaller and faster: a review of conventional and nanocalorimetry techniques for determining thermophysical properties of nuclear materials

Thermal analysis of nuclear materials is critical for the advancement of nuclear technology. The heat effects associated with heat capacity, phase transformation, and radiation damage can be measured with conventional calorimeters. However, conventional calorimetric techniques are often restricted in terms of heating rate and sample mass, especially when studying the limited amounts of materials subject to extreme conditions. In this review, we summarize conventional calorimetric studies of critical thermophysical and thermochemical properties of pure actinide metals (U, Np, Am, Pu), fast reactor metallic fuel alloy systems (U–Zr, U–Pu–Zr, Pu–U, Pu–Zr), and actinide oxides that are primary constituents or transmutation products in light water reactor fuel rods (U–O, Np–O, Am–O, Pu–O, Pu–U–O). Adiabatic and drop calorimetry have been the primary techniques used for these studies, however the development of fast scanning calorimetry using micro-electro-mechanical-based systems allows determination of thermodynamic properties from smaller sample masses. We report recent investigations that leverage the fast heating rates of nanocalorimetry by itself or combined with other characterization techniques. Furthermore, we then discuss opportunities for nanocalorimetry to provide solutions to some of the technical challenges inherent in thermal analysis of nuclear materials, namely a reduction in sample activity, emulating heating transients, investigation of phase evolution in irradiated samples, and characterization of radiation damage evolution. Nanocalorimetry has the potential to significantly advance the understanding of thermophysical properties in nuclear materials and thus accelerate the development of nuclear technology.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗