Imaging spectrophotometry of ionized gas in NGC 1068. I - Kinematics of the narrow-line region

The kinematics of collisionally excited forbidden N II 6548, 6583 across the inner 1 arcmin diameter of the nearby Seyfert galaxy NGC 1068 is mapped using an imaging Fabry-Perot interferometer and low-noise CCD. The stack of monochromatic images, which spatially resolved the high-velocity gas, was analyzed for kinematic and photometric content. Profiles agree well with previous long-slit work, and their complete spatial coverage makes it possible to constrain the gas volume distribution. It is found that the narrow-line region is distributed in a thick center-darkened, line-emitting cylinder that envelopes the collimated radio jet. Three distinct kinematic subsystems, of which the cylinder is composed, are discussed in detail. Detailed behavior of the emission-line profiles, at the few points in the NE quadrant with simple kinematics, argues that the ionized gas develops a significant component of motion perpendicular to the jet axis.

Cecil, Gerald↗

Technical considerations on using the large Nancay radio telescope for SETI

The Nancay decimetric Radio Telescope (NRT) in Nancay, France, is described, and its potential use for Search for Extraterrestrial Intelligence (SETI) observations is discussed. The conclusion reached is that the NRT is well suited for SETI observations because of its large collecting area, its large sky coverage, and its wideband frequency capability. However, a number of improvements are necessary in order to take full advantage of the system in carrying out an efficient SETI program. In particular, system sensitivity should be increased. This can be achieved through a series of improvements to the system, including lowering the ground pickup noise through the use of ground reflectors and more efficient feed design, and by using low-noise amplifier front ends.

Gulkis, S.↗

Imaging spectrophotometry of the nuclear outflow of NGC 1068

This observational program (in conjunction with R. B. Tully (IfA, Honolulu), and J. Bland (Rice U., Houston)) aims to constrain the kinematic organization and dominant excitation mechanisms of ionized gas in active galaxies. More generally, researchers are interested in the dynamics of radiative, supersonic flows in the Interstellar Medium (ISM). Imaging Fabry-Perot interferometers and low-noise Charge Coupled Devices (CCDs) are used for complete spatial coverage of the complex gas distribution in circumnuclear narrow-line regions (NLRs). Extranuclear emission line widths in NLRs can exceed 3000 km s(-1), so to avoid inter-order confusion researchers use an etalon of 4000 km s(-1) free spectral range to map (N II) lambda lambda 6548, 6583 and H alpha. To maximize spatial resolution, researchers select nearby active systems independent of luminosity but known to possess interesting morphologies and/or high-velocity extranuclear ionized gas. Monochromatic images Full Width Half Maximum (FWHM) approx. 65 km s(-1) have thus far been obtained in 1 second or better seeing at the U. Hawaii 2.2m, CFH 3.6m, and CTIO 4.0m telescopes. These are stacked into grids of line profiles, of spectrophotometric quality, at sub-arcsecond increments across a 3 second field. To handle the approx. 20,000 to 300,000 useful spectra that arise from a typical night's work, researchers have developed a complete analysis and reduction package for VAX and Sun image workstations. Reduction involves parametrization of approx. 10 to the 8th raw data points to a few maps (e.g., velocities of each kinematic subsystem, continuum-free line fluxes) containing approx. 10 to the 5th pixels. Researchers identify kinematic and structural symmetries by examining these maps and the point to point variations of the synthesized line profiles. The combination of monochromatic images and full spatial sampling of line profiles has allowed them to isolate such symmetries and has led to reliable kinematic deprojections.

Cecil, Gerald↗

Advanced CCD imager technology for use from 1 to 10,000 A

A low-noise, high-sensitivity charge-coupled-device (CCD) technology for imaging applications extending from the soft X-ray (1 A) to the near-infrared (10,000 A) regimes was developed together with a fabrication technology for making back-illuminated versions of these devices with quantum efficiencies as high as 90 percent from 5000 to 7000 A. The efforts have focused on two devices, a 64 x 64 pixel back-illuminated imager with two output ports that operates at 2000 frames per second with 23 electrons read noise, and a larger device, with 420 x 420 pixel format, designed for lower frame rates with noise as low as 1.5 electrons and used at visible, UV, and X-ray wavelengths. Applications to plasma diagnostics include Thomson scattering and high-frame-rate imaging in the visible, as well as X-ray imaging and bolometry.

Twichell, J. C.↗

dc modulation noise in thin film magnetic recording disk media

A study of dc modulation noise as a function of magnetic layer thickness has been conducted for plated longitudinal low-noise Co-alloy disk media with a range of 900 to 1100 Oe. The noise, produced by the application of a reverse longitudinal dc field to a uniformly magnetized disk, supplies data regarding the uniformity of the disk. A spectrum analyzer measures the noise by means of electronic detection, and noise spectra and autocorrelation functions calculated with a model are compared to the experimental results. The model correlates with experimental data to more than 0.99. The maximum distance between effective transitions diminishes from 2.8 microns to 1 micron when the thickness of the magnetic layer is increased from 25 nm to 60 nm. The maximum average transition amplitude is found to be independent of thickness, and is bounded by 0.001 of the saturation magnetization.

Katti, R. R.↗

Integrated millimeter-wave corner-cube antennas

An integrated corner-reflector antennas has been designed, fabricated, and measured at millimeter-wave frequencies. The structure consists of a traveling-wave antenna integrated on a 1.2-micron dielectric membrane, and suspended in a longitudinal cavity etched in a silicon wafer. A novel traveling wave antenna design, the modified-bend antenna, with an antenna length of 1.2 lambda and spacing 0.96 lambda from the apex, results in a wideband input impedance centered at 140 Ohm and low cross-polarization levels. Measurements at 180-270 GHz show a well-defined pattern with low sidelobe levels, and a main-beam efficiency of 93 percent and 83 percent at 180 and 222 GHz, respectively. The monolithic approach allows the integration of a matching network and a Schottky-diode or SIS detector at the base of the antenna to yield a low-noise monolithic millimeter-wave receiver.

Gearhart, Steven S.↗

A compact 2.5-Kelvin closed-cycle refrigerator

A helium refrigerator utilizing the Gifford-McMahon/Joule-Thomson cycle was designed and tested to demonstrate the feasibility of using small closed-cycle refrigerators as an alternative to batch filled-cryostats for operating temperatures below 4 K. The systems could be used to cool low-noise microwave maser amplifiers located in large parabolic antennas. These antennas tilt vertically, making conventional liquid-filled dewars difficult to use. The system could also be used for a nontilting beam waveguide antenna to reduce the helium consumption of a liquid helium cryostat. The prototype system is adjustable to provide 700 milliwatts of cooling at 2.5 K to 3 watts at 4.3 K. The performance of the unit is not significantly affected by operation in any physical orientation.

Britcliffe, Mike↗

Radio science experiment of Voyager-2 spacecraft occultation by Neptune

NASA-JPL and Japan's Institute of Space and Astronautical Science collaborated at the Usuda Deep Space Center in the Voyager-2 Neptune occultation experiment. Phase information is extracted from the recorded data by means of a digital filter that can track the carrier frequency and narrow the filter bandwidth by up to 3 mHz. The results thus obtained can verify the phase-stability of the receiving system as a whole. Problems experienced by low-noise amplifiers were solved through the use of system redundancies.

Hayashi, T.↗

Video guidance sensor

A Martin-Marietta study comparing the application of laser, video, or RF sensors was conducted in 1982. The study concluded that video was the most attractive sensor (the video also could be used for operator monitoring). The Retro-Reflector field Tracker from the Solar Array Flight Experiment was chosen as a 'first generation' sensor and integrated with guidance algorithms for evaluation on the air-bearing vehicle. Results indicated that this sensor was not applicable for the noise environment posed by the multi-layer insulation used on most spacecraft. A 'second generation' sensor was developed to be used with a modified RMS target. This sensor utilized two sets of laser diodes to acquire three optically filtered targets. The targets were illuminated first with a 780 nanometer diode, followed by illumination with a 830 nm diode. The second digitized picture was subtracted from the first to get a low-noise image. The centroids of the retroreflectors were used then to uniquely derive target attitude and range. The sensor presently operates to 80 feet and within +/- 40 degrees in pitch and yaw. Sensor operability is a concern if the sun is within a +/- 40 degree cone angle to the target. The present sensor performance characteristics are less than 1 percent range error and less than 1 degree angle error. Future sensor development is anticipated to extend the operating range to 150 feet and reduce the cone angle of sensor inoperability to within +/- 10 degrees of direct sunlight. Performance improvements also are anticipated. TRW currently is developing a system that utilizes dual cameras with simultaneous diode illumination. Although further development is being pursued, the basic system has proven sound, and the sensor is essentially ready for application.

Howard, Richard↗

Project Echo: Receiving System

A tracking horn-reflector antenna, a maser preamplifier (and standby parametric preamplifier), and a special FM demodulator were combined to form a low-noise receiving system which made possible the establishment of a high-quality voice circuit via the Echo I passive satellite. This paper describes the 2390-Mc receiving system located at the Bell Telephone Laboratories facility in Holmdel, New Jersey.

Ohm, E. A.↗

Project Echo: 961-Mc Lower - Sideband Up - Converter for Satellite-Tracking Radar

A 961-Mc lower-sideband up-converter was specially designed to serve as preamplifier for the satellite-tracking radar used in Project Echo. The amplifier and its power supply are separately boxed and are installed directly behind the tracking antenna. The amplifier has been functioning most satisfactorily and has been used in routine manner to track the Echo satellite from horizon to horizon. This paper describes the design considerations, and details the special steps taken to ensure that the amplifier met the particular system needs of low noise, absolute stability, insensitivity to temperature fluctuations, and high input-power level before the onset of gain compression. The satisfactory operation of this amplifier confirms the great potentiality of parametric amplifiers as stable, low-noise, high-frequency receivers.

Uenohara, M.↗

Pocket ECG electrode

A low-noise electrode suited for sensing electrocardiograms when chronically and subcutaneously implanted in a free-ranging subject. The electrode comprises a pocket-shaped electrically conductive member with a single entrance adapted to receive body fluids. The exterior of the member and the entrance region is coated with electrical insulation so that the only electrolyte/electrode interface is within the member remote from artifact-generating tissue. Cloth straps are bonded to the member to permit the electrode to be sutured to tissue and to provide electrical lead flexure relief.

Lund, Gordon F.↗

The Canadian Galactic Emission Mapper (CGEM) A Cosmic Microwave Foreground Experiment

The Canadian Galactic Emission Mapper (CGEM) is a 4-meter single-dish radio telescope located at the Dominion Radio Astrophysical Observatory (DRAO) in Penticton, Canada. CGEM is designed to map polarized Galactic synchrotron emission across the entire northern sky at 8-10 GHz with 1 MHz frequency resolution and ∼ 0.5 degree angular resolution. Its goal is to obtain high-fidelity, low-noise maps of polarized Galactic synchrotron radiation, at frequencies where synchrotron dominates, in order to provide a reliable template for CMB B−mode foreground cleaning. We will show on sky performance of CGEM’s single-pixel azimuthally-symmetric telescope, its coherent, dual-polarized radiometer, and show maps made from commissioning data from the first few months of operation.

Cosmic microwave background↗

Automating Sensor Characterization with Bayesian Optimization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert's time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Cuevas-Zepeda, Julian [Chicago U., KICP; Chicago U↗

SPT-3G D1: Compton-$y$ maps using data from the SPT-3G and Planck surveys

We present thermal Sunyaev-Zel'dovich (tSZ) Compton-$y$ parameter maps constructed from two years (2019-2020) of observations with the South Pole Telescope (SPT) third-generation camera, SPT-3G, combined with data from the Planck satellite. Using a linear combination (LC) pipeline, we obtain a suite of reconstructions that explore different trade-offs between statistical sensitivity and suppression of astrophysical contaminants, including minimum-variance, CMB-deprojected, and CIB-deprojected $y$-maps. We validate these maps through different statistical techniques such as auto- and cross-power spectra with large-scale structure tracers as well as stacking on cluster locations. These tests are used to understand the balance between noise and astrophysical foreground residuals (such as the CIB) in combination with the recovery of the tSZ signal for different maps. For example, results from stacking at the location of clusters confirm the robustness of the recovered tSZ signal over the $\sim 1500\: {\rm deg}^2$ SPT-3G survey field used in this analysis. The high-resolution and low-noise maps produced here provide an important cosmological tool for future studies, including measurements of the Compton-$y$ map power spectrum, cross-correlations with other tracers of the large-scale structure, detailed modeling of cluster pressure profiles, and study of the thermodynamic state of the baryons in the Universe.

Maniyar, A. S. [Harvard-Smithsonian Ctr. Astrophys↗

MAS-CCD: New technique for measuring low-level charge content based on the multiple amplifier architecture

Low-noise detectors are a key technology for the next generation of astronomical instruments aimed at spectroscopy of faint objects and the search for exoplanets. In this context, the multiple-amplifier sensing charge-coupled device (MAS-CCD) emerges as a promising technology for future scientific instruments. A critical parameter affecting the performance of these devices is spurious charge, produced by the clocking of the gates. Its measurement is typically challenging with existing methods. In practice, the optimization of this parameter often relies on empirical procedures that require significant time and careful consideration of the trade-off with full-well capacity. In this work, we present a new technique to estimate spurious charge based on covariance analysis of the output amplifiers of the MAS-CCD, which measures the same charge packet in different amplifiers at different times. The method enables fast and precise measurements of spurious charge under operating conditions where conventional approaches are difficult to apply. We develop the theoretical framework of the method and validate the model through simulations. The results demonstrate the feasibility of this approach and suggest that it could serve as a basis for reliable large-scale characterization of sensor performance.

Gamero, Miqueas E. [Buenos Aires, CONICET; Fermila↗

Alcock-Paczynski Blinding Scheme for the Ly-$α$ Forest Analysis

We present and validate a blinding method for the Lyman-$α$ (Ly$α$) forest analysis based on a modification of the Alcock-Paczynski test. In order to hide the background expansion history, the method employs a geometrical shift of each quasar (QSO) forest in wavelength space, once the quasar continuum has been fitted and the fluctuation field is extracted. The redshift positions for the QSO sample are also changed in a consistent manner. We show that the method remains effective when applied to real data, where contamination from metals and Lyman-$β$ is intrinsically mixed with the Lyman-$α$ forest. This limitation is primarily visible in the 1D correlation function, where other blinding strategies can mitigate the effect. To assess its effectiveness, the prescription is tested against a series of datasets of increasing complexity: from idealized low-noise mocks, to realistic DESI year one synthetic datasets, and finally to data from DESI first data release (DR1), using both the auto (Ly$α\times$Ly$α$) and cross (Ly$α\times$ QSO) correlations. We find that the method robustly shifts the BAO peak position from the 3D correlation functions to the expected value for cosmology changes of around 5% in the matter content, without altering the shape of the posteriors in the model parameters. In conclusion, this catalog-level blinding strategy is a viable method for cosmological inference with the Lyman-$α$ forest, particularly if a cross-analysis with other tracers using the same blinding strategy is pursued.

Perez-Sanchez, G. [Guanajuato U.] (ORCID:000900096↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.