Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Persistent Expression Changes of Fibrosis Related Genes in the Lung Tissues of Rats Exposed to Lunar Dust Particles

The Moon's surface is covered by a layer of reactive dust, containing 1-2% of respirable fine dust (< 3 microns). The habitable area of any lunar landing vehicle would inevitably be contaminated with lunar dust that could pose a health risk. The purpose of the study is to evaluate the toxicity of Apollo moon dust in rodents through inhalation to assess the health risk of dust exposures to humans and to identify the mechanisms and potential pathways involved in lunar dust-induced toxicity. Ccl3, Ccl12, Cxcl2, Cxcl5, Itgb8, Tnf, Ldhc, Clec4e, Bmp7, and Smad6, showed persistently significant expression changes in the lung tissue. The expression of several of these genes were dose- and time- dependent, and were significantly correlated with other pathological. Our previous data showed that no pathological changes were detected in low dose groups. However, several genes, primarily produced by lung epithelial, were significantly altered persistently in response to low-dose dust exposure. The data presented in this study, for the first time, explores the molecular mechanisms of lunar dust induced toxicity, contributing not only the risk assessment for future space exploration, but also understandings of the dust-induced toxicity to humans on earth.

Zhang, Ye↗

The Importance of Conducting Life Sciences Experiments on the Deep Space Gateway Platform

Over the last several decades important information has been gathered by conducting life science experiments on the Space Shuttle and on the International Space Station. It is now time to leverage that scientific knowledge, as well as aspects of the hardware that have been developed to support the biological model systems, to NASA's next frontier - the Deep Space Gateway. In order to facilitate long duration deep space exploration for humans, it is critical for NASA to understand the effects of long duration, low dose, deep space radiation on biological systems. While carefully controlled ground experiments on Earth-based radiation facilities have provided valuable preliminary information, we still have a significant knowledge gap on the biological responses of organisms to chronic low doses of the highly ionizing particles encountered beyond low Earth orbit. Furthermore, the combined effects of altered gravity and radiation have the potential to cause greater biological changes than either of these parameters alone. Therefore a thorough investigation of the biological effects of a cis-lunar environment will facilitate long term human exploration of deep space.

microgravity↗

Total Ionizing Dose Test of Silicon Switching Transistors JANTXV2N2222AUB

Semicoa's silicon switching transistors, JANTXV2N2222AUB was tested for total ionizing dose (TID) response beginning on November 4, 2019. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Campola, M.↗

Evaluation of an Accelerated ELDRS Test Using Molecular Hydrogen

An accelerated total ionizing dose (TID) hardness assurance test for enhanced low dose rate sensitive (ELDRS) bipolar linear circuits, using high dose rate tests on parts that have been exposed to molecular hydrogen, has been proposed and demonstrated on several ELDRS part types. In this study several radiation-hardened "ELDRS-free" part types have been tested using this same approach to see if the test is overly conservative.

radiation effects↗

Total Ionizing Dose Testing of the Analog Devices’ AD648 Dual Precision Operational Amplifier

The Analog Devices (ADI) AD648 was tested for total ionizing dose response at the Goddard Space Flight Center (GSFC) Radiation Effects Facility (REF) beginning 1 June 2011. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Alvin J Boutte↗

RH1021BMH-10 Precision 10 V Reference Total Ionizing Dose Test Report

The purpose of this test was to validate the Analog Devices (ADI) RH1021BMH-10 flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for this flight lot with wafer lot number 769658.1 and lot date code (LDC) 1430A. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Casey, Megan↗

Total Ionizing Dose Test of Analog Devices’ AD654 Voltage to Frequency Converter

Analog Devices’ AD654 was tested for total ionizing dose (TID) response beginning on February 13, 2017. This device has the Radiation Effects and Analysis Group Identification (REAG ID) number 16-036. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

B. Freeman↗

Ptychographic atomic electron tomography: Towards three-dimensional imaging of individual light atoms in materials

Through numerical simulations, we demonstrate the combination of ptychography and atomic electron tomography as an effective method for low dose imaging of individual low-Z atoms in three dimensions. After generating noisy diffraction patterns with multislice simulations of an aberration-corrected scanning transmission electron microscope through a 5-nm zinc-oxide nanoparticle, we have achieved three-dimensional (3D) imaging of individual zinc and oxygen atoms and their defects by performing tomography on ptychographic projections. The methodology has also been simulated in 2D materials, resolving individual sulfur atoms in vertical WS 2 /WSe 2 van der Waals heterostructure with a low total electron dose where annular-dark-field images fail to resolve. Overall, we envision that the development of this method could be instrumental in studying the precise 3D atomic structures of radiation sensitive systems and low-Z atomic structures such as 2D heterostructures, catalysts, functional oxides, and glasses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluations of Silicon Carbide Temperature Monitors

The effect of irradiation on materials properties is an important field of study for materials usage in both fission and fusion systems for energy production. Neutron flux and energy spectrums are well understood; however, the irradiation temperature can be more difficult to determine. Since the early 1960s, Silicon Carbide (SiC) has been used as a passive post-irradiation temperature monitor because the irradiation defects anneal out above the irradiation temperature. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process. There are many properties that may be measured including electrical resistivity, bulk density, dimensions, thermal diffusivity, or lattice spacing. Electrical resistivity is accepted as a robust measurement technique; however, such method is time-consuming since the steps involved must be performed in a serial manner. The use of thermal expansion from continuous dilatometry is an automated process requiring minimal setup time. As part of a Nuclear Science User Facilities (NSUF) project, low dose silicon carbide monitors were irradiated in the BR2 material test reactor at SCK, Belgium, and were then evaluated at the Idaho National Laboratory (INL) High Temperature Test Laboratory (HTTL) to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation processes available at HTTL and the performance of the low dose silicon carbide temperature monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SHP2 genetic variants in NSML-associated RASopathies disrupt the PZR–IRX transcription factor signaling axis

Noonan syndrome with multiple lentigines (NSML) is a rare autosomal dominant disorder caused by mutations inPTPN11(protein tyrosine phosphatase nonreceptor type 11) which encodes for the protein tyrosine phosphatase, SHP2. Approximately 85% of NSML patients develop hypertrophic cardiomyopathy (HCM). Here, we show that SHP2 is recruited to tyrosyl phosphorylated protein-zero related (PZR) in NSML mice. This recruitment is required for the Iroquois homeobox (IRX) transcription factors 3 and 5 to suppress BMP10 which negatively regulates postnatal cardiac growth. The protein expression of IRX3 and IRX5 was elevated in hypertrophied NSML hearts. IRX3 and IRX5 upregulation was rescued in NSML mice harboring a knock-in mutation of PZR that fails to become tyrosyl phosphorylated and recruit SHP2. NSML mice treated with low-dose dasatinib also exhibited normalized IRX3 and IRX5 expression levels. Consistent with this, BMP10 expression levels were reduced in NSML mice and rescued in PZR tyrosyl phosphorylation-deficient and low-dose dasatinib-treated NSML mice. A crystal structure of the tandem SH2 domains of SHP2 bound to tyrosyl phosphorylated PZR reveals that recruitment constrains the open SHP2 conformation to facilitate cellular-Src (c-Src) binding. Disruption of c-Src binding to SHP2 abolished IRX activation and failure to suppress BMP10. Hence, NSML-associated SHP2 genetic variants disrupt IRX transcription factor signaling to BMP10, implicating this axis as a target for RASopathy-associated HCM.

Science & Technology - Other Topics↗

Protection against Different Genotypes of Newcastle Disease Viruses (NDV) Afforded by an Adenovirus-Vectored Fusion Protein and Live NDV Vaccines in Chickens

The efficacy of an adenovirus-vectored Newcastle disease virus (NDV) vaccine expressing the fusion (F) NDV protein (adeno-F) was evaluated against challenges with virulent heterologous and homologous NDV strains to the F protein. In a preliminary study, two different doses (low and high) of adeno-F were tested against a virulent NDV strain containing the homologous NDV F protein, CA02. In a second study, at three weeks post-vaccination, the efficacy of the high dose of adeno-F was compared to a live attenuated NDV vaccine strain (LaSota) against three antigenically distinct virulent NDV challenge strains, one homologous (CA02) and two heterologous (TZ12, EG14) to F in the vectored vaccine. In both experiments, clinical signs, mortality, virus shedding, and humoral response were evaluated. In the first experiment, the survival rates from birds vaccinated with adeno-F at a high and low dose were 100% and 25%, respectively. In the second experiment, birds vaccinated with the high dose of adeno-F had a survival rate of 80%, 75%, and 65% after challenge with the CA02, TZ12, and EG14 viruses, respectively. All of the LaSota-vaccinated birds survived post-challenge no matter the NDV challenge strain. High antibody titers were detected after vaccination with LaSota by HI and ELISA tests. The majority of adeno-F-vaccinated birds had detectable antibodies using the ELISA test, but not using the HI test, before the challenge. The data show that both the similarity of the F protein of the adeno-F vaccine to the challenge virus and the adeno-F vaccination dose affect the efficacy of an adenovirus-vectored NDV vaccine against a virulent NDV challenge.

Ferreira, Helena L. (ORCID:0000000232613712)↗

Anticancer effect of AZD2461 PARP inhibitor against colon cancer cells carrying wt or dysfunctional p53

Colon cancer is one of the most common cancers, currently treated with traditional chemotherapies or alternative therapies. However, these treatments are still not enough effective and induce several side effects, so that the search of new therapeutic strategies is needed. The use of Poly-(ADP-ribose)-polymerase (PARP) inhibitors, although originally approved against BRCA-1 or BRCA-2 mutated cancers, has been extended, particularly in combination with other treatments, to cure cancers that do not display defects in DNA repair signaling pathways. The role of p53 oncosuppressor in the regulating the outcome of PARP inhibitor treatment remains an open issue. In this study, we addressed this topic by using a well-tolerated PARP 1/2/3 inhibitor, namely AZD2461, against colon cancer cell lines with different p53 status. We found that AZD2461 reduced cell proliferation in wtp53 and p53−/− cancer cells by increasing ROS and DNA damage, while R273H mutant (mut) p53 counteracted these effects. Moreover, AZD2461 improved the reduction of cell proliferation by low dose radiation (IR) in wtp53 cancer cells, in which a down-regulation of BRCA-1 occurred. AZD2461 did not affect cell proliferation of mutp53 colon cancer cells also in combination with low dose radiation, suggesting that only wt p53 or p53 null colon cancer cells could benefit AZD2461 treatment.

60 APPLIED LIFE SCIENCES↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Responses of Microbes to Modeled Space Radiation

The built environment of spaceships is host to a microbial community that affects crew and craft alike. While the static composition of this community has been characterized and its temporal dynamics examined, the mechanisms controlling its make-up and evolutionary trajectory are not understood. Systematic analyses of microbial diversity show consistent patterns in community composition and function. Understanding these patterns' ecological origins remains a significant challenge, as it requires connecting processes at varying temporal and spatial scales. However, it is clear that the state and trajectories of microbial communities are in-part determined by their physical environment. In this regard, the spaceflight environment includes numerous interacting factors that differentiate it from Earth environments, including an altered atmospheric composition, reduced gravity (and thus altered fluid dynamics), and increased ionizing radiation. These factors impart selective pressures on microbial communities that affect their evolutionary trajectories and thus the risks and benefits these communities represent to crew and craft. The radiation environment of space leads to chronic exposure to low doses and is difficult to mimic on Earth. Thus, little is known about how microbial communities in spacecraft will respond and evolve. Therefore, given the limitations of existing studies, we aim to empirically determine how exposure to low doses of ionizing radiation for thousands of cell divisions affects rates of mutation accumulation in bacteria and the trajectory of their evolution. In this way, we will provide a critical set of data for designing safe and robust space missions. Here we discuss our progress towards this aim, including the construction of exposure facilities, our culturing and analysis approach, and preliminary data.

radiation↗

Measuring Very Low Radiation Doses in PTFE for Nuclear Forensic Enrichment Reconstruction

Every country that has made nuclear weapons has used uranium enrichment. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment that can be used to perform forensic verification of historically produced weapons. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon's quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing a detection of tampering and a method for analyzing field samples useful for treaty verification. This work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

Connick, Rachel↗

Locating the atoms at the hard-soft interface of gold nanoparticles

Surface structure affects the growth, shape and properties of nanoparticles. In wet chemical syntheses, metal additives and surfactants are used to modify surfaces and guide nanocrystal growth. To understand this process, it is critical to understand how the surface structure, and hence its energy, is modified. However, measuring the type and arrangement of atoms at hard-soft interfaces on nanoscale surfaces, especially in the presence of surfactants, is extremely challenging. Here, we determine the atomic structure of the hard-soft interface in a metallic nanoparticle by developing low-dose imaging conditions in four-dimensional scanning transmission electron microscopy that are preferentially sensitive to surface adatoms. By revealing experimentally the copper additives and bromide surfactant counterion at the surface of a gold nanocuboid and quantifying their interatomic distances, our direct, low-dose imaging method provides atomic-level understanding of chemically sophisticated nanomaterial surface structures. These measurements of the atomic structure of the hard-soft interface provide the information necessary to understand and quantify surface chemistries and energies and their pivotal role in nanocrystal growth.

Li, Weilun [Monash University, Melbourne, VIC (Aus↗

Measuring very low radiation doses in PTFE for nuclear forensic enrichment reconstruction

Every country that has made nuclear weapons has used uranium enrichment to do so. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment in the open literature that can be used to perform forensic verification of historically produced weapons on gas centrifuges. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon’s quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing detection of tampering and a method for analyzing field samples useful for treaty verification. Furthermore, this work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Radiation-induced bystander effect and adaptive response in mammalian cells

Two conflicting phenomena, bystander effect and adaptive response, are important in determining the biological responses at low doses of radiation and have the potential to impact the shape of the dose-response relationship. Using the Columbia University charged-particle microbeam and the highly sensitive AL cell mutagenic assay, we show here that non-irradiated cells acquire mutagenesis through direct contact with cells whose nuclei have been traversed with a single alpha particle each. Pretreatment of cells with a low dose of X-rays four hours before alpha particle irradiation significantly decreased this bystander mutagenic response. Results from the present study address some of the fundamental issues regarding both the actual target and radiation dose effect and can contribute to our current understanding in radiation risk assessment. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Discipline Radiation Health↗