Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Dirty dishes or dirty laundry? Comparing two methods for quantifying American consumers' preferences for load management in a smart home

One challenge of transitioning to renewable energy is that household electricity use and renewable generation are often misaligned. Smart home energy management systems hold promise for shifting usage to match generation, but these systems need to be designed with the occupants’ preferences in mind. The purpose of the present research is to compare two approaches for collecting and modeling consumers’ load management preferences, both of which are amenable to use in a home energy management system. Specifically, we examine the performance of Simple Multi-Attribute Rating Technique Exploiting Ranks (SMARTER) and Analytic Hierarchy Process (AHP) in quantifying consumers’ preferences regarding air temperature (air conditioning and heating), water heating, dishwashing, clothes washing and drying, monetary costs, environmental impacts, and comfort/convenience. Two studies are presented: Study 1 examines the SMARTER approach, and Study 2 focuses on the AHP approach. In both studies, online surveys (N SMARTER = 956 and N AHP = 1023) were conducted to elicit preferences from participants across the United States. The preferences modeled by both approaches were validated based on (a) their ability to predict participants’ choices in a Discrete Choice Experiment and (b) their convergence with previous research on load-shifting behavior. The validation procedure suggests that the SMARTER approach is superior in modeling consumers’ preferences for load management. Overall, this research lays the groundwork for designing a smart home interface capable of collecting occupants’ preferences and using those preferences to deliver improved occupant comfort, lower operating costs, reduced environmental impact, and more significant demand response than exists today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reduction of structural loads using maneuver load control on the Advanced Fighter Technology Integration (AFTI)/F-111 mission adaptive wing

A transonic fighter-bomber aircraft, having a swept supercritical wing with smooth variable-camber flaps was fitted with a maneuver load control (MLC) system that implements a technique to reduce the inboard bending moments in the wing by shifting the spanwise load distribution inboard as load factor increases. The technique modifies the spanwise camber distribution by automatically commanding flap position as a function of flap position, true airspeed, Mach number, dynamic pressure, normal acceleration, and wing sweep position. Flight test structural loads data were obtained for loads in both the wing box and the wing root. Data from uniformly deflected flaps were compared with data from flaps in the MLC configuration where the outboard segment of three flap segments was deflected downward less than the two inboard segments. The changes in the shear loads in the forward wing spar and at the roots of the stabilators also are presented. The camber control system automatically reconfigures the flaps through varied flight conditions. Configurations having both moderate and full trailing-edge flap deflection were tested. Flight test data were collected at Mach numbers of 0.6, 0.7, 0.8, and 0.9 and dynamic pressures of 300, 450, 600, and 800 lb/sq ft. The Reynolds numbers for these flight conditions ranged from 26 x 10(exp 6) to 54 x 10(exp 6) at the mean aerodynamic chord. Load factor increases of up to 1.0 g achieved with no increase in wing root bending moment with the MLC flap configuration.

Thornton, Stephen V.↗

Environmental loading effects on structures

The environment in which a structure vibrates influences its modal characteristics. Presented herein is experimental modal survey test results on splitter vanes under liquid nitrogen mass-pressure-thermal loading. In particular, shifts in modal frequencies are studied via frequency response functions, power spectral densities, isoplots, quadrature or imaginary plots, and vibration mode shape characteristics generated from strain and acceleration measurements. Analyses have shown that while mass loading lowers the frequencies, increased pressure and lower temperature have opposite effect. Thus, pressurization and cooling of a liquid causes the modal frequencies of the structure in which it is contained to shift upward.

Panossian, H. V.↗

Penetration Bounds For Azimuthal Slot On Infinite Cylinder With Finite Length Backing Cylindrical Cavity

We examine coupling into azimuthal slots on an infinite cylinder with a infinite length interior cavity operating both at the fundamental cavity modal frequencies, with small slots and a resonant slot, as well as higher frequencies. The coupling model considers both radiation on an infinite cylindrical exterior as well as a half space approximation. Bounding calculations based on maximum slot power reception and interior power balance are also discussed in detail and compared with the prior calculations. For higher frequencies limitations on matching are imposed by restricting the loads ability to shift the slot operation to the nearest slot resonance; this is done in combination with maximizing the power reception as a function of angle of incidence. Finally, slot power mismatch based on limited cavity load quality factor is considered below the first slot resonance.

42 ENGINEERING↗

Thermal and mechanical performance of gypsum composites containing fly ash cenosphere encapsulated phase change materials

Utilizing phase change materials (PCMs) within construction materials improves the thermal energy storage capabilities in the built environment. Notably, integrating PCMs into drywalls presents a promising avenue to reduce building energy use. However, incorporating PCMs into drywalls poses challenges, particularly reduced mechanical properties and workability limitations as it can adversely affect the hardening and cohesiveness of gypsum composites. To address these challenges, this study explores a novel strategy to incorporate PCMs into gypsum composites through fly ash cenosphere-encapsulated PCM, namely CenoPCM, aiming to enhance the mechanical properties and thermal conductivity over existing commercial counterparts. An experimental program was conducted to study the impact of the inclusion of CenoPCM on the mechanical and thermal performance of gypsum composites, and the results were compared to those of commercially available polymerencapsulated PCM benchmark (Micronal). The findings highlighted that PCM-charged samples exhibited up to 95.90 J/g (CenoPCM) of latent heat with 70 % CenoPCM loading. The results of mechanical tests also showed that CenoPCM outperformed its polymer-encapsulated counterpart, achieving 55 % higher mechanical strength on average. Here, this improvement is attributed to the rigid shell of fly ash cenosphere (FAC) serving as a PCM carrier, providing a skeleton-like structure to gypsum composites for higher load-bearing capacity. Additionally, hotbox tests demonstrated that the CenoPCM-charged wall panels yielded a 20 % higher thermal conductivity and a 22 % increased time lag compared to Micronal PCM-charged panels, indicating its potential to shift the peak load in buildings.

Ceno PCM↗

Techno-Economic Analysis of Dynamic Building Envelopes Comprising Phase Change Materials and Switchable Insulations: Preprint

Integrating phase change materials (PCMs) in building envelopes is a recognized technique to reduce the space heating/cooling loads and provide load shedding and shifting capacity. However, PCM benefits have been found to reduce dramatically with increase in the insulation requirements. Dynamic building envelopes that can alter their thermal resistance based on the indoor and outdoor conditions can effectively harness free ambient heating/cooling, thereby greatly enhancing the benefits of the PCM-integrated envelope in managing thermal loads. In this study, we examine various combinations of PCMs and switchable insulations and compare their combined impact on heat flow through the building envelope. Using numerical analysis, we investigate the PCM- and switchable insulation-integrated building walls, calculate the potential energy saving benefits compared to the conventional static walls, and finally perform technoeconomic analysis to estimate the acceptable cost of the technology under various payback period scenarios.

dynamic building envelopes↗

Techno-Economic Analysis of Dynamic Building Envelopes Comprising Phase Change Materials and Switchable Insulations

Integrating phase change materials (PCMs) in building envelopes is a recognized technique to reduce the space heating/cooling loads and provide load shedding and shifting capacity. However, PCM benefits have been found to reduce dramatically with increase in the insulation requirements. Dynamic building envelopes that can alter their thermal resistance based on the indoor and outdoor conditions can effectively harness free ambient heating/cooling, thereby greatly enhancing the benefits of the PCM-integrated envelope in managing thermal loads. In this study, we examine various combinations of PCMs and switchable insulations and compare their combined impact on heat flow through the building envelope. Using numerical analysis, we investigate the PCM- and switchable insulation-integrated building walls, calculate the potential energy saving benefits compared to the conventional static walls, and finally perform techno-economic analysis to estimate the acceptable cost of the technology under various payback period scenarios.

dynamic building envelopes↗

Evaluation of ceramic packed-rod regenerator matrices

An extensive evaluation of a modified cryocooler with various regenerator matrices is reported. The matrices examined are 0.015 in. diam. Pb spheres and 0.008, 0.015, and 0.030 in. diam. rods of a 0.2% SnCl2 doped ceramic labelled LS-8A. Specific heat and thermal conductivity data on these rod materials are also reported. The chronic pulverization/dusting problem common to Pb spheres was investigated. During a 1000 hr life test with 0.0008 in. diam. rods there was no degradation of the refrigerator performance, and a subsequent examination of the rods themselves revealed no evidence of breakage or pulverization. The load temperature characteristics for the rod packed regenerators were inferior to that for the Pb spheres, the effect being to shift the Pb spheres load curve up in temperature. This temperature shift was 5.0, 7.4, and 11.6K for the 0.0008, 0.015, and 0.030 in. diam. rods, respectively.

Lawless, W. N.↗

Defining and applying an electricity demand flexibility benchmarking metrics framework for grid-interactive efficient commercial buildings

Building demand flexibility (DF) research has recently gained attention. To unlock building DF as a predictable grid resource, we must establish a quantitative understanding of the resource size, performance variability, and predictability based on large empirical datasets. Researchers have proposed various sets of theoretical metrics to measure this performance. Some metrics have been applied to simulation results, but most fall short of exploring the complexities in real building applications. There are practical metrics used in individual demand response field studies but they alone cannot fulfil the job of DF benchmarking across a diverse group of buildings. The electrical grid's geographically diverse and changing nature presents challenges to comparing building DF performance measured under different conditions (i.e., benchmarking DF). To address this challenge, a novel DF benchmarking framework focused on load shedding and shifting is presented; the foundation is a set of simple, proven single-event metrics with attributes describing event conditions. These enable benchmarking and visualization in different dimensions for identifying trends that represent how these attributes influence DF. To test its feasibility and scalability, the DF framework was applied to two case studies of 11 office buildings and 121 big-box retail buildings with demand response participation data. Furthermore, these examples provided a pathway for using both building level benchmarking and aggregation to extract insights into building DF about magnitude, consistency, and influential factors. Potential applications of the framework and real-world values have been identified for grid and building stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonizing all-electric communities via carbon-responsive control of behind-the-meter resources

The progression of electrification in the building and transportation sectors brings new opportunities for energy decarbonization. With higher dependence on the grid power supply, the variation of the grid carbon emission intensity can be utilized to reduce the carbon emissions from the two sectors. Existing coordinated control methods for buildings with distributed energy resources (DERs) either consider electricity price or renewable energy generation as the input signal, or adopt optimization in the decision-making, which is difficult to implement in the real-world environment. This paper aims to propose and validate an easy-to-deploy rule-based carbon responsive control framework that facilitates coordination between all-electric buildings and electric vehicles (EVs). The signals of the grid carbon emission intensity and the local photovoltaics (PV) generation are used for shifting the controllable loads. Extensive simulations were conducted using a model of an all-electric mixed-use community in a cold climate to validate the control performance with metrics such as emissions, energy consumption, peak demand, and EV end-of-day state-of-charge (SOC). Our study identifies that 4.5% to 27.1% of annual emission reduction can be achieved with limited impact on energy costs, peak demand, and thermal comfort. Additionally, up to 32.7% of EV emission reduction can be obtained if the EV owners reduce the target SOC by less than 21.2%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

Wood template-supported phase change material composites for durable and form-stable thermal energy storage in buildings

Here, to reduce and shift peak energy loads in buildings, phase change materials (PCMs) with high transition enthalpies and transition temperatures near human thermal comfort are desirable for thermal energy storage (TES). Traditional solid/liquid PCMs suffer from leakage during thermal cycling, requiring encapsulation that lowers heat storage capacity. Wood templates (WTs), with porous and hierarchical structures, provide natural encapsulation scaffolds for PCM containment. Polyethylene glycol (PEG) is a compatible PCM with WTs, but when infiltrated alone, ~30 wt% of PEG binds to wood with no detectable phase change, limiting TES efficiency. To address this, we developed a method to (1) improve the form stability of balsa and pine-based composites (BWT + PCMs and PWT + PCMs) and (2) reduce inactive PCM within the composites to ~10 wt%. BWT + PCMs exhibit transition properties upwards of 114.2 J/g at 25.4 degrees C, with no degradation after 1000 thermal cycles, and similar stiffness compared to raw balsa. Meanwhile, PWT + PCMs exhibit 25 % higher storage efficiency with the addition of poly(ethylene glycol) diacrylate compared to solely PEG-infiltrated PWT. PWT + PCM retains 84 % of raw pine's mechanical stiffness, sufficient for light-duty construction. Our shape-stabilized WT + PCM composites enrich the functionality of wood materials as both ideal TES material candidates and light-duty building construction applications.

25 ENERGY STORAGE↗

Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks

Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. Finally, this paper is focused on establishing the significance of the convection numbers in conjunction with the Reynolds number for modeling the thermal stratification in storage tanks.

14 SOLAR ENERGY↗

Interligand Coupling Drives Fast Triplet Energy Transfer Routes in PbS/Tetracene Quantum Dot Hybrids

The binding of photoactive organic ligands to inorganic quantum dots (QDs) creates a versatile hybrid architecture that allows access to photophysical processes such as efficient triplet exciton generation with near-infrared radiation. Here we report the subnanosecond generation of a hybrid triplet state with mixed ligand-QD character by replacing native oleate ligands on small PbS QDs with 5,12-tetracenepropiolic acid, a bifunctional ligand with two carboxylic acids that tends to lie face-on with the QD surface at low loadings. The face-on geometry engenders a regime of strong electronic coupling that is evident in steady-state absorption and hastens triplet energy flow by several orders of magnitude compared with more typical tetracene-based ligands exhibiting weak coupling. We further determined via Fourier transform infrared (FTIR) and supported by density functional theory (DFT)-based geometry optimizations that high ligand loading causes a shift in QD-ligand mutual disposition toward an edge-on geometry that instigates the formation of intermolecular excited states characterized by triplet excimer-like features in photoluminescence and transient absorption. Our results demonstrate the ability to control strongly coupled ligand-QD systems toward ultrafast generation of photophysically relevant species such as triplets that are valuable for photon upconversion and catalysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

BE-SATED: Building Energy Storage At The Edges of Demand

Otherlab is leading research efforts to validate and deploy battery-integrated appliances in real-world settings. The primary goal is to demonstrate the ability of these appliances to shift residential energy loads and reduce peak demand. Additionally, the project aims to secure safety certifications for battery-integrated appliances and establish a key industrial partnership with an appliance manufacturer for broader market adoption.

25 ENERGY STORAGE↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗