Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load following”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Friction Stir Dovetailing of AA7099 to Steel with AA6061 Interlayer for Reduced Zn Embrittlement at Dissimilar Interface

Joining of high strength Al alloy (AA7099) to steel (rolled homogeneous armor) with and without AA6061 interlayer was achieved using a friction stir dovetailing (FSD) method. Detailed investigations were conducted to establish correlations between mechanical performance and microstructural evolution of FSD joints. Lap shear tensile testing revealed that incorporation of the AA6061 interlayer combined with tailored processing methodology significantly improved both mechanical interlocking and load transmission across the dovetail interface. Following incorporation of the interlayer, the maximum load carrying capacity and peak extension (of the AA7099/AA6061/steel joint) are 60% and 210% higher, respectively, than results obtained from an AA7099/steel joint without an interlayer. Without an AA6061 interlayer, formation of zinc rich intermetallic compounds led to brittle interfacial failure of the AA7099-steel FSD joint. Incorporation of novel tool and joint configuration eliminated asymmetric joint performance as a function of loading direction, which is generally observed in friction stir lap welding. The efficacy of the use of an AA6061 interlayer in joining AA7099 to steel was demonstrated through mechanical testing as well as high resolution analytical electron microscopy characterization.

Dissimilar metal joining, Friction stir dovetailin↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. GFM inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generators) and follow the change in the load demand; however, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help grid operators better manage their inverter-based resources (IBRs) to improve operation efficiency and reliability; therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and synchronous generators) to output the target power in both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters.

dispatching↗

Exploring the parameter space of MagLIF implosions using similarity scaling. I. Theoretical framework

Magneto-inertial fusion concepts, such as the magnetized liner inertial fusion (MagLIF) platform, constitute an alternative path for achieving ignition and significant fusion yields in the laboratory. The space of experimental input parameters defining a MagLIF load is highly multi-dimensional, and the implosion itself is a complex event involving many physical processes. In the first paper of this series, we develop a simplified analytical model that identifies the main physical processes at play during a MagLIF implosion. Using non-dimensional analysis, we determine the most important dimensionless parameters characterizing MagLIF implosions and provide estimates of such parameters using typical fielded or experimentally observed quantities for MagLIF. Here, we then show that MagLIF loads can be “incompletely” similarity scaled, meaning that the experimental input parameters of MagLIF can be varied such that many (but not all) of the dimensionless quantities are conserved. Based on similarity-scaling arguments, we can explore the parameter space of MagLIF loads and estimate the performance of the scaled loads. Then, in the follow-up papers of this series, we test the similarity-scaling theory for MagLIF loads against simulations for two different scaling “vectors,” which include current scaling and rise-time scaling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fuel Property Effects on Stochastic Preignition Events During Engine Load Transitions

Stochastic preignition (SPI) is an abnormal combustion phenomenon that can cause catastrophic engine damage. There have been several proposed mechanisms of SPI, where a uniform source is still not certain, however, SPI tendencies have been shown to be influenced by engine operating conditions, oil composition, engine age, and fuel chemical and physical properties. Laboratory research and testing for SPI propensity is challenging given the stochastic nature of events, as well as the potential for significant degradation of the engine platform and measuring equipment over time. Thus, SPI specific experiments are generally conducted under either sustained or cyclic patterning of steady-state operating conditions to avoid the influence of transient engine boundary conditions on test parameters of interest (e.g. oil additive package, fuel properties, engine speed/load, etc.). In this work a cyclically varying SPI test sequence involves a 5 min engine warmup period at a low engine load of around 4 bar gross indicated mean effective pressure (IMEPg), followed by a transition to high load (~20 bar IMEPg) at a constant 2000 rev/min engine speed for a total of 25 min. This individual test sequence load schedule is then sequentially repeated 10 times to generate significant statistical data for analysis. This work examines the influence of fuel chemical and physical properties on SPI tendency during the unsteady portion of the 10-cycle sequence (the first 5 min of the high load operation in each sequence of the loading cycle) which has been discarded from previous analyses due to the uncertainty in engine operating and thermal boundary conditions. Results from this analysis suggest an increasing trend in the ratio of SPI events during the unsteady test period relative to the steady test period with increasing fuel Reid Vapor Pressure (RVP), implying differences in uncontrolled ignition source terms, possibly from, fuel wall interactions and retention during the load transition phase of the test.

Splitter, Derek [ORNL] (ORCID:0000000174044047)↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

Tailoring compatibilization potential of maleic anhydride–grafted polypropylene by sequential rheochemical processing of polypropylene and polyamide 66 blends

Reactive compatibilization of immiscible polymer blends using a preferred compatibilizer leaves the following question: How much loading of a compatibilizer is good enough and what maximum properties can be achieved? A good understanding of the process can help solve the reutilization of mixed waste plastics. Here, the reactive compatibilization of polypropylene-graft-maleic anhydride (PP-g-MAH) on polypropylene/polyamide 66 (PP/PA66) blends is quantitatively assessed using thermorheological, microoptical, spectroscopic, and x-ray scattering-based characterization tools. The overall compositions of all PP(60%)/PA66(30%)/PP-g-MAH(10%) blends are kept constant while systematically controlling the degree of the chemical reaction by varying the sequential addition of PP-g-MAH to the melt mixture. The first feeding of PP-g-MAH (x%, 0 ≤ x ≤ 10) is conducted at 280°C and the second feeding of (10–x)% is at 200°C. During the first step, a larger amount of chemical activity is observed up to 4%–6% addition of PP-g-MAH. Furthermore, the constant chemical composition allows a systematic comparison of the compatibilizer-dependent thermal, rheological, morphological, and mechanical properties. With an increased degree of interfacial reaction, the size of dispersed PA66 domains decreases to register improved interfacial adhesion with the PP matrix, yielding enhanced Young's modulus and absolute failure strength of the isotropic matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operation and Control of a Back to Back Modular Multilevel Converter System for Grid Forming Application with Advanced Grid Support Functionalities

The main focus of this paper is to investigate the possibility of using modular multilevel converter based back-to-back system for grid forming applications. A decentralized hierarchical control architecture with a modified local controller based on nonlinear techniques for grid forming application have been investigated. Grid functionalities based on IEEE 1547-2018 for grid forming converters have been utilized. The local controllers ensure distortion free balanced sinusoidal output voltage on the grid forming side with unbalanced or nonlinear loading condition. The grid following side ensures unity power factor currents under unbalanced grid voltage condition. The dc bus voltage control ensures oscillation free voltage under balanced conditions and control of the average voltage under unbalanced condition. Efficacy of the overall system is verified by modeling the system in MATLAB/Simulink and PLECS domain and the most important case studies are presented.

advanced grid support functionalities↗

Final Status Report Confirming Completion of Mechanical Testing of HFIR Irradiated Nanocomposite Materials

This report provides a final status report on the in-cell mechanical testing of High Flux Isotope Reactor (HFIR)-irradiated nanodispersion-strengthened materials at the Irradiated Materials Examination and Testing (IMET) facility. All tension tests were performed at room temperature with a nominal strain rate of 0.018 mm/mm/min using shoulder-loading grip sets by following the standard testing procedure in ASTM E8/E8M. Round 1 (unirradiated) and round 2 (0.7 dpa) testing was completed in FY 2021. This report confirms completion of round 3 (1.4 dpa) and round 4 (2.1 dpa) tensile testing in FY 2022 with examples of test data collected on select sample conditions. Additionally, the report includes IDs of samples selected for shipment to Idaho National Laboratory (INL) for additional characterization.

36 MATERIALS SCIENCE↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic DC optimal power flow with reserve saturation

We propose an optimization framework for stochastic optimal power flow with uncertain loads and renewable generator capacity. Our model follows previous work in assuming that generator outputs respond to load imbalances according to an affine control policy, but introduces a model of saturation of generator reserves by assuming that when a generator’s target level hits its limit, it abandons the affine policy and produces at that limit. This is a particularly interesting feature in models where wind power plants, which have uncertain upper generation limits, are scheduled to provide reserves to balance load fluctuations. Here, the resulting model is a nonsmooth nonconvex two-stage stochastic program, and we use a stochastic approximation method to find stationary solutions to a smooth approximation. Computational results on 6-bus and 118-bus test instances demonstrate that by considering the effects of saturation, our model can yield solutions with lower expected generation costs (at the same target line violation probability level) than those obtained from a model that enforces the affine policy to stay within generator limits with high probability.

17 WIND ENERGY↗

Biomechanical Analysis of Multilevel Posterior Cervical Spinal Fusion Constructs

Study Design: Controlled Laboratory Study Objective: To compare multilevel posterior cervical fusion (PCF) constructs stopping at C7, T1, and T2 under cyclic load to determine the range of motion (ROM) between the lowest instrumented level and lowest instrumented-adjacent level (LIV-1). Summary of Background Data: PCF is a mainstay of treatment for various cervical spine conditions. The transition between the flexible cervical spine and rigid thoracic spine can lead to construct failure at the cervicothoracic junction. There is little evidence to determine the most appropriate level at which to stop a multilevel PCF. Methods: Fifteen human cadaveric cervicothoracic spines were randomly assigned to 1 of 3 treatment groups: PCF stopping at C7, T1, or T2. Specimens were tested in their native state, following a simulated PCF, and after cyclic loading. Specimens were loaded in flexion-extension), lateral bending, and axial rotation. Three-dimensional kinematics were recorded to evaluate ROM. Results: The C7 group had greater flexion-extension motion than the T1 and T2 groups following instrumentation (10.17±0.83 degree vs. 2.77±1.66 degree and 1.06±0.55 degree, P <0.001), and after cyclic loading (10.42±2.30 degree vs. 2.47±0.64 degree and 1.99±1.23 degree, P <0.001). There was no significant difference between the T1 and T2 groups. The C7 group had greater lateral bending ROM than both thoracic groups after instrumentation (8.81±3.44 degree vs. 3.51±2.52 degree, P =0.013 and 1.99±1.99 degree, P =0.003) and after cyclic loading. The C7 group had greater axial rotation motion than the thoracic groups (4.46±2.27 degree vs. 1.26±0.69 degree, P =0.010; and 0.73±0.74 degree, P =0.003) following cyclic loading. Conclusion: Motion at the cervicothoracic junction is significantly greater when a multilevel PCF stops at C7 rather than T1 or T2. This is likely attributable to the transition from a flexible cervical spine to a rigid thoracic spine. Although this does not account for in vivo fusion, surgeons should consider extending multilevel PCF constructs to T1 when feasible. Level of Evidence: Not applicable.

Neurosciences & Neurology↗

Large Load Management and Grid Planning

This presentation will cover these topics, followed by a discussion and Q&A: Grid impacts of load growth of the current bulk power system, a review of recent trends and events related to large load integration, what might these new large loads look like, what are options for reducing costs and timelines of integration, and working toward a framework for identifying hot spots for efficiently interconnecting large loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probing the Morphology and Mobility of Amines in Porous Silica CO 2 Sorbents by 1 H T 1 – T 2 Relaxation Correlation NMR

Molecular and oligomeric amines supported in porous oxide supports are a promising class of CO 2 sorbent materials studied for CO 2 removal from diverse streams such as flue gas and ambient air. Among the various amines investigated, low molecular weight, hyperbranched poly(ethyleneimine) (PEI), and tetraethylenepentamine (TEPA) are among the most extensively studied. While macroscopic structure–performance relationships relating the support structure, amine loading, and other factors affecting CO 2 sorption capacities and kinetics have been developed, structural and dynamic information about the organic amine phase in the porous support is less plentiful. The structure and mobility of amines impregnated in the pores of porous supports directly impact gas sorption, as the accessibility of amine sites in the pores directly relates to amine distribution in the pores and overall pore filling as well as the dynamics of the amine chains. Here, we prepare a family of mesoporous silica SBA-15 materials containing varying loadings of oligomeric (PEI) and molecular (TEPA) amines. 1 H T 1 –T 2 relaxation correlation solid-state NMR experiments are used to characterize the structural and dynamic properties of the confined amines. Both TEPA and PEI are shown to form multiple different domains in the pores, each with distinguishable dynamic properties. TEPA and PEI form more rigid layers around the silica support walls at lower organic loading fractions, characterized by lower mobilities, followed by the formation of more mobile domains less engaged in pore wall interactions at higher loadings. TEPA shows faster mobilities than PEI because of its lower molecular weight. TEPA also appears to more easily transfer between domains within the pores, leading to generally faster CO 2 uptake rates with higher sorption capacities, while PEI located closer to the pore walls remained much less mobile and is thus less engaged in CO 2 capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hooks versus Pedicle Screws at the Upper Instrumented Level: An In Vitro Biomechanical Comparison

Study Design. Controlled laboratory study Objective. To compare motions at the upper instrumented vertebra (UIV) and supra-adjacent level (UIV+1) between two fixation techniques in thoracic posterior spinal fusion (PSF) constructs. We hypothesized there would be greater motion at UIV+1 after cyclic loading across all constructs and bilateral pedicle screws (BPS) with posterior ligamentous compromise would demonstrate the greatest UIV+1 range of motion (ROM). Summary of Background Data. Proximal junctional kyphosis (PJK) is a well-recognized complication following long thoraco-lumbar PSF, however its mechanism is poorly understood. Methods. Twenty-seven thoracic functional spine units (FSU) were randomly divided into three UIV fixation groups (n=9): (1) BPS, (2) bilateral transverse process hooks (TPH), and (3) BPS with compromise of the posterior elements between UIV and UIV+1 (BPS-C). Specimens were tested on a servohydraulic materials testing system in native state, following instrumentation, and after cyclic loading. FSUs were loaded in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Results. After cyclic testing, the TPH group had a mean 29.4% increase in FE ROM at UIV+1 versus 76.6% in the BPS group ( P <0.05). The BPS-C group showed an increased FE of 49.9% and 62.19% with sectioning of the facet joints and interspinous ligament respectively prior to cyclic testing. Conclusion. Bilateral pedicle screws at the UIV led to greater motion at UIV+1 compared to bilateral TPH after cyclic loading. This is likely due to the increased rigidity of BPS compared to TPH leading to a “softer” transition between the TPH construct and native anatomy at the supra-adjacent level. Facet capsule compromise led to a 49.9% increase in UIV+1 motion, underscoring the importance of preserving the posterior ligamentous complex. Clinical studies that account for fusion rates are warranted to determine if constructs with a “soft transition” result in less PJK in vivo.

Neurosciences & Neurology↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Enhancing Grid Resilience with HIVE: Decentralized V2G Coordination for Black Starts

This paper proposes the HIVE (Harmonized Integration of Vehicle Energy for Grid Support) model, a novel game-theoretic framework for decentralized coordination of electrified vehicles to enable black start and load restoration during grid outages. In the absence of a central controller, HIVE employs a cooperative game to model vehicle interactions, allowing autonomous decision-making while admitting to a Nash equilibrium for grid restoration. The framework addresses the heterogeneity of vehicles and their operational constraints, selecting a lead vehicle for grid-forming and coordinating grid-following vehicles to support prioritized loads. Applied to a hospital blackout scenario, HIVE demonstrates robust performance in forming an islanded microgrid and sustaining critical loads under varying vehicle availability, state of charge, and power constraints. Simulation results highlight the model’s effectiveness in ensuring decentralized coordination of energy allocation and prioritizing loads, offering a scalable solution for resilient grid operations.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Understanding early HIV-1 rebound dynamics following antiretroviral therapy interruption: The importance of effector cell expansion

Most people living with HIV-1 experience rapid viral rebound once antiretroviral therapy is interrupted; however, a small fraction remain in viral remission for an extended duration. Understanding the factors that determine whether viral rebound is likely after treatment interruption can enable the development of optimal treatment regimens and therapeutic interventions to potentially achieve a functional cure for HIV-1. We built upon the theoretical framework proposed by Conway and Perelson to construct dynamic models of virus-immune interactions to study factors that influence viral rebound dynamics. We evaluated these models using viral load data from 24 individuals following antiretroviral therapy interruption. The best-performing model accurately captures the heterogeneity of viral dynamics and highlights the importance of the effector cell expansion rate. Our results show that post-treatment controllers and non-controllers can be distinguished based on the effector cell expansion rate in our models. Furthermore, these results demonstrate the potential of using dynamic models incorporating an effector cell response to understand early viral rebound dynamics post-antiretroviral therapy interruption.

60 APPLIED LIFE SCIENCES↗