Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear induction accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Soldered Contact and Current Risetime Effects on Negative Polarity Wire Array Z-pinches

The Cornell University COBRA pulser is a nominal 1 MA machine, capable of driving up to 32 wire cylindrical Z-pinch arrays. COBRA can operate with variable current risetimes ranging from 100 ns to 200 ns (short and long pulse, respectively). Wires are typically strung with a 'press' contact to the electrode hardware, where the wire is loosely pulled against the hardware and held there to establish electrical contact. The machine is normally negative, but a bolt-on convolute can be used to modify the current path and effectively produce positive polarity operation at the load.Previous research with single wires on a 1-5 kA pulser has shown that soldering the wire, thereby improving the wire/electrode contact, and operating in positive polarity can improve the energy deposition into the wire and enhance wire core expansion. Negative polarity showed no difference. Previous experiments on the negative polarity, 20 MA, 100 ns Z accelerator have shown that improving the contact improved the x-ray yield.Cornell data were collected on 16-wire Aluminum Z-pinch arrays in negative polarity. Experiments were conducted with both short and long current pulses with soldered and no-soldered wire/electrode contacts. The initiation, ablation, implosion and stagnation phases were compared for these four conditions. Time dependent x-ray signals were measured using diodes and diamond detectors. An inductive voltage monitor was used to infer minimum current radius achieved, as defined by a uniform shell of current moving radially inward, producing a time dependent inductance. Total energy data were collected with a metal-strip bolometer. Self-emission data were collected by an XUV 4-frame camera and an optical streak camera.In negative polarity and with short pulses, soldering appeared to produce a smaller radius pinch and decrease variations in the x-ray pulse shape. The bolometer, laser backlighter, 4-frame and streak cameras showed negligible differences in the initiation ablation and implosion phases. X-ray yield was increased with soldered arrays in negative polarity with long pulses. The bolometer also showed a 50% increase in radial power emitted for soldered arrays. 4-frame images showed soldered arrays have a more pronounced 'Christmas Tree' effect originating from the cathode. The inductive voltage monitor showed, with both long and short pulses, that soldered and no-solder arrays reached the same minimum current radius at the same time. However, with long pulses soldered arrays radiate x-rays at the time of minimum current radius while no-solder array x-ray output is delayed by {approx}20 ns, resulting in decreased x-ray yield.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiosensitization by PARP inhibition to proton beam irradiation in cancer cells

The poly(ADP-ribose) polymerase (PARP)-1 regulates DNA damage responses and promotes base excision repair. PARP inhibitors have been shown to enhance the cytotoxicity of ionizing radiation in various cancer cells and animal models. We have demonstrated that the PARP inhibitor (PARPi) AZD2281 is also an effective radiosensitizer for carbon-ion radiation; thus, we speculated that the PARPi could be applied to a wide therapeutic range of linear energy transfer (LET) radiation as a radiosensitizer. Institutes for biological experiments using proton beam are limited worldwide. This study was performed as a cooperative research at heavy ion medical accelerator in Chiba (HIMAC) in National Institute of Radiological Sciences. HIMAC can generate various ion beams; this enabled us to compare the radiosensitization effect of the PARPi on cells subjected to proton and carbon-ion beams from the same beam line. After physical optimization of proton beam irradiation, the radiosensitization effect of the PARPi was assessed in the human lung cancer cell line, A549, and the pancreatic cancer cell line, MIA PaCa-2. The effect of the PARPi, AZD2281, on radiosensitization to Bragg peak was more significant than that to entrance region. The PARPi increased the number of phosphorylated H2AX (γ-H2AX) foci and enhanced G2/M arrest after proton beam irradiation. This result supports our hypothesis that a PARPi could be applied to a wide therapeutic range of LET radiation by blocking the DNA repair response. - Highlights: • Effective radiosensitizers for particle radiation therapy have not been reported. • PARP inhibitor treatment radiosensitized after proton beam irradiation. • The sensitization at Bragg peak was greater than that at entrance region. • DSB induction and G2/M arrest is involved in the sensitization mechanism.

60 APPLIED LIFE SCIENCES↗

Charged-particle mutagenesis II. Mutagenic effects of high energy charged particles in normal human fibroblasts

The biological effects of high LET charged particles are a subject of great concern with regard to the prediction of radiation risk in space. In this report, mutagenic effects of high LET charged particles are quantitatively measured using primary cultures of human skin fibroblasts, and the spectrum of induced mutations are analyzed. The LET of the charged particles ranged from 25 KeV/micrometer to 975 KeV/micrometer with particle energy (on the cells) between 94-603 MeV/u. The X-chromosome linked hypoxanthine guanine phosphoribosyl transferase (hprt) locus was used as the target gene. Exposure to these high LET charged particles resulted in exponential survival curves; whereas, mutation induction was fitted by a linear model. The Relative Biological Effect (RBE) for cell-killing ranged from 3.73 to 1.25, while that for mutant induction ranged from 5.74 to 0.48. Maximum RBE values were obtained at the LET of 150 keV/micrometer. The inactivation cross-section (alpha i) and the action cross-section for mutant induction (alpha m) ranged from 2.2 to 92.0 micrometer2 and 0.09 to 5.56 x 10(-3) micrometer2, respectively. The maximum values were obtained by 56Fe with an LET of 200 keV/micrometer. The mutagenicity (alpha m/alpha i) ranged from 2.05 to 7.99 x 10(-5) with the maximum value at 150 keV/micrometer. Furthermore, molecular analysis of mutants induced by charged particles indicates that higher LET beams are more likely to cause larger deletions in the hprt locus.

NASA Center JSC↗

Scaling magnetized liner inertial fusion on Z and future pulsed-power accelerators

The MagLIF (Magnetized Liner Inertial Fusion) concept [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] has demonstrated fusion–relevant plasma conditions [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)] on the Z accelerator with a peak drive current of about 18 MA. We present 2D numerical simulations of the scaling of MagLIF on Z as a function of drive current, preheat energy, and applied magnetic field. The results indicate that deuterium-tritium (DT) fusion yields greater than 100 kJ could be possible on Z when all of these parameters are at the optimum values: i.e., peak current = 25 MA, deposited preheat energy = 5 kJ, and B{sub z} = 30 T. Much higher yields have been predicted [S. A. Slutz and R. A. Vesey, Phys. Rev. Lett. 108, 025003 (2012)] for MagLIF driven with larger peak currents. Two high performance pulsed-power accelerators (Z300 and Z800) based on linear-transformer-driver technology have been designed [W. A. Stygar et al., Phys. Rev. ST Accel. Beams 18, 110401 (2015)]. The Z300 design would provide 48 MA to a MagLIF load, while Z800 would provide 65 MA. Parameterized Thevenin-equivalent circuits were used to drive a series of 1D and 2D numerical MagLIF simulations with currents ranging from what Z can deliver now to what could be achieved by these conceptual future pulsed-power accelerators. 2D simulations of simple MagLIF targets containing just gaseous DT have yields of 18 MJ for Z300 and 440 MJ for Z800. The 2D simulated yield for Z800 is increased to 7 GJ by adding a layer of frozen DT ice to the inside of the liner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Repair of clustered DNA damage caused by high LET radiation in human fibroblasts

It has recently been demonstrated experimentally that DNA damage induced by high LET radiation in mammalian cells is non-randomly distributed along the DNA molecule in the form of clusters of various sizes. The sizes of such clusters range from a few base-pairs to at least 200 kilobase-pairs. The high biological efficiency of high LET radiation for induction of relevant biological endpoints is probably a consequence of this clustering, although the exact mechanisms by which the clustering affects the biological outcome is not known. We discuss here results for induction and repair of base damage, single-strand breaks and double-strand breaks for low and high LET radiations. These results are discussed in the context of clustering. Of particular interest is to determine how clustering at different scales affects overall rejoining and fidelity of rejoining of DNA double-strand breaks. However, existing methods for measuring repair of DNA strand breaks are unable to resolve breaks that are close together in a cluster. This causes problems in interpretation of current results from high LET radiation and will require new methods to be developed.

NASA Discipline Radiation Health↗

Evaluation of Oxygen Consumption as a Sensitive Measure of Electrical Cable Polymer Insulation Degradation

Polymers used as dielectric materials in nuclear grade electrical cables, such as cross-linked polyethylene (XLPE) and ethylene-propylene rubber (EPR), are long-lived and durable. Estimating the decades-long useful service life of polymers experimentally in a feasible timeframe of weeks or months requires greatly accelerated aging in the laboratory at elevated temperatures and/or gamma dose rates. Many limitations of accelerated aging, such as due to artefacts of the process including diffusion limited oxidation and dose rate effects, have been identified that can make accurate lifetime prediction at service conditions challenging. This can be due to differences in degradation mechanisms between rapid and extended aging or to the presence of induction periods during which early aging is undetectable using common metrics of polymer insulation characterization such as tensile elongation at break. Conceptually, an ideal measure of aging would track clearly and predictably with material changes throughout the lifecycle of the evolving material state from early aging through end of useful life. With such a metric accelerated aging could be performed at much milder conditions, conditions closer to those found in long term service, and end of life calculated from the early data. Oxygen consumption has previously been proposed as a sensitive measure of insulation polymer oxidation that might meet such desirable characteristics. In this work, nuclear cable insulation samples of the two most common types, XLPE and EPR, from two of the most sourced manufacturers, RSCC and The Okonite Company, were subjected to gamma irradiation at dose rates of 100, 200, and 300 Gy/hr for up to 42 days at 26°C. The aged samples were used to evaluate oxygen consumption as a sensitive measure of aging for these materials and these conditions. For comparison and validation, the aged samples were also characterized using the more conventional tests of mass change, density, carbonyl index, and yellowness index. For both materials, oxygen consumption during irradiation was found to track consistently with applied dose—oxygen consumption rate was linear with time. Mass change and carbonyl index were also clearly proportional to exposure dose. Yellowness index, a surface sensitive measure, was observed to increase linearly with dose at low exposure levels before plateauing. Sample density was not observed to change under the conditions explored. Oxygen consumption was found to be a particularly sensitive metric to measure the degradation of polymeric cable insulation exposed to radiation. Oxygen consumption was compared to Arrhenius and time-temperature-superposition methods for activation energy calculation using literature date and found to be a useful and viable alternative for lifetime prediction. The techniques developed in this work are anticipated to be valuable in the estimation of insulation aging rates under mild conditions approaching service conditions. Direction comparison of useful life prediction by oxygen consumption with prediction via Arrhenius methodology for thermal aging and existing methods for radiation and combined thermal/radiation aging would serve to further validate this promising approach and refine our understanding of material-specific aging rates.

36 MATERIALS SCIENCE↗

Inductively Driven, 3D Liner Compression of a Magnetized Plasma to Megabar Energy Densities

To take advantage of the smaller scale, higher density regime of fusion an efficient method for achieving the compressional heating required to reach fusion gain conditions must be found. What is proposed is a more flexible metallic liner compression scheme that minimizes the kinetic energy required to reach fusion. It is believed that it is possible to accomplish this at sub-megajoule energies. This however will require operation at very small scale. To have a realistic hope of inexpensive, repetitive operation, it is essential to have the liner kinetic energy under a megajoule which allows for the survivability of the vacuum and power systems. At small scale the implosion speed must be reasonably fast to maintain the magnetized plasma (FRC) equilibrium during compression. For limited liner kinetic energy, it becomes clear that the thinnest liner imploded to the smallest radius consistent with the requirements for FRC equilibrium lifetime is desired. The proposed work is directed toward accomplishing this goal. Typically an axial (Z) current is employed for liner compression. There are however several advantages to using a θ-pinch coil. With the θ-pinch the liner currents are inductively driven which greatly simplifies the apparatus and vacuum system, and avoids difficulties with the post implosion vacuum integrity. With fractional flux leakage, the foil liner automatically provides for the seed axial compression field. To achieve it with optimal switching techniques, and at an accelerated pace however will require additional funding. This extra expense is well justified as the compression technique that will be enabled by this funding is unique in the ability to implode individual segments of the liner at different times. This is highly advantageous as the liner can be imploded in a manner that maximizes the energy transfer to the FRC. Production of shaped liner implosions for additional axial compression can thus be readily accomplished with the modified power modules. The additional energy and switching capability proposed will thus provide for optimal utilization of the liner energy. The following tasks were outlined for the three year effort: (1) Design and assemble the foil liner compression test structure and chamber including the compression bank and test foils [Year 1]. (2) Perform foil liner compression experiments and obtain performance data over a range on liner dimensions and bank parameters [Year 2]. (3) Carry out compression experiments of the FRC plasma to Megagauss fields and measure key fusion parameters [Year 3]. (4) Develop numerical codes and analyze experimental results, and determine the physics and scaling for future work [Year 1-3]. The principle task of the project was to design and assemble the foil liner FRC formation chamber, the full compression test structure and chamber including the compression bank. This task was completed successfully. The second task was to test foils in the test facility constructed in year one and characterize the performance obtained from liner compression. These experimental measurements were then compared with analytical predictions, and numerical code results. The liner testing was completed and compared with both the analytical results as well as the code work performed with the 3D structural dynamics package of ANSYS Metaphysics®. This code is capable of modeling the dynamic behavior of materials well into the non-linear regime (e.g. a bullet hit plate glass). The liner dynamic behavior was found to be remarkably close to that predicted by the 3D structural dynamics results. Incorporating a code that can also include the magnetics and plasma physics has also made significant progress at the UW. The remaining test bed construction and assembly task is was completed, and the FRC formation and merging experiments were carried out as planned. The liner compression of the FRC to Megagauss fields was not performed due to not obtaining a sufficiently long lived FRC during the final year of the grant. Modifications planned to correct this deficiency included a larger FRC source as well as a much larger liner driver energy storage system. Due to discontinuation of the grant neither of these improvements were carried out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual designs of two petawatt-class pulsed-power accelerators for high-energy-density-physics experiments

Here, we have developed conceptual designs of two petawatt-class pulsed-power accelerators: Z 300 and Z 800. The designs are based on an accelerator architecture that is founded on two concepts: single-stage electrical-pulse compression and impedance matching [Phys. Rev. ST Accel. Beams 10, 030401 (2007)]. The prime power source of each machine consists of 90 linear-transformer-driver (LTD) modules. Each module comprises LTD cavities connected electrically in series, each of which is powered by 5-GW LTD bricks connected electrically in parallel. (A brick comprises a single switch and two capacitors in series.) Six water-insulated radial-transmission-line impedance transformers transport the power generated by the modules to a six-level vacuum-insulator stack. The stack serves as the accelerator’s water-vacuum interface. The stack is connected to six conical outer magnetically insulated vacuum transmission lines (MITLs), which are joined in parallel at a 10-cm radius by a triple-post-hole vacuum convolute. The convolute sums the electrical currents at the outputs of the six outer MITLs, and delivers the combined current to a single short inner MITL. The inner MITL transmits the combined current to the accelerator’s physics-package load. Z 300 is 35 m in diameter and stores 48 MJ of electrical energy in its LTD capacitors. The accelerator generates 320 TW of electrical power at the output of the LTD system, and delivers 48 MA in 154 ns to a magnetized-liner inertial-fusion (MagLIF) target [Phys. Plasmas 17, 056303 (2010)]. The peak electrical power at the MagLIF target is 870 TW, which is the highest power throughout the accelerator. Power amplification is accomplished by the centrally located vacuum section, which serves as an intermediate inductive-energy-storage device. The principal goal of Z 300 is to achieve thermonuclear ignition; i.e., a fusion yield that exceeds the energy transmitted by the accelerator to the liner. 2D magnetohydrodynamic (MHD) simulations suggest Z 300 will deliver 4.3 MJ to the liner, and achieve a yield on the order of 18 MJ. Z 800 is 52 m in diameter and stores 130 MJ. This accelerator generates 890 TW at the output of its LTD system, and delivers 65 MA in 113 ns to a MagLIF target. The peak electrical power at the MagLIF liner is 2500 TW. The principal goal of Z 800 is to achieve high-yield thermonuclear fusion; i.e., a yield that exceeds the energy initially stored by the accelerator’s capacitors. 2D MHD simulations suggest Z 800 will deliver 8.0 MJ to the liner, and achieve a yield on the order of 440 MJ. Z 300 and Z 800, or variations of these accelerators, will allow the international high-energy-density-physics community to conduct advanced inertial-confinement-fusion, radiation-physics, material-physics, and laboratory-astrophysics experiments over heretofore-inaccessible parameter regimes.

42 ENGINEERING↗

Effect of track structure and radioprotectors on the induction of oncogenic transformation in murine fibroblasts by heavy ions

The oncogenic potential of high-energy 56Fe particles (1 GeV/nucleon) accelerated with the Alternating Gradient Synchrotron at the Brookhaven National Laboratory was examined utilizing the mouse C3H 10T1/2 cell model. The dose-averaged LET for high-energy 56Fe is estimated to be 143 keV/micrometer with the exposure conditions used in this study. For 56Fe ions, the maximum relative biological effectiveness (RBEmax) values for cell survival and oncogenic transformation were 7.71 and 16.5 respectively. Compared to 150 keV/micrometer 4He nuclei, high-energy 56Fe nuclei were significantly less effective in cell killing and oncogenic induction. The prostaglandin E1 analog misoprostol, an effective oncoprotector of C3H 10T1/2 cells exposed to X rays, was evaluated for its potential as a radioprotector of oncogenic transformation with high-energy 56Fe. Exposure of cells to misoprostol did not alter 56Fe cytotoxicity or the rate of 56Fe-induced oncogenic transformation.

NASA Discipline Radiation Health↗

Synthesis of Correct Digital Controller Models from Specifications by Model Transformation (21-0320)

The design of high consequence controllers (in weapons systems, autonomy, etc.) that do what they are supposed to do is a significant challenge. Testing simply does not come close to meeting the requirements for assurance. Today circuit designers at Sandia (and elsewhere) typically capture the core behavior of their components using state models in tools such as STATEFLOW. They then check that their models meet certain requirements (e.g. “The system bus must not deadlock” or “both traffic lights at an intersection must not be green at the same time”) using tools called model checkers. If the model checker returns “yes” then the property is guaranteed to be satisfied by the model. However, there are several drawbacks to this industry practice: (1) there is a lot of detail to get right, this is particularly challenging when there are multiple components requiring complex coordination (2) any errors returned by the model checker have to be traced back through the design and fixed, necessitating rework, (3) there are severe scalability problems with this approach, particularly when dealing with concurrency. All this places high demands on the designers who now face not only an accelerated schedule but also controllers of increasing complexity. This report describes a new and fundamentally different approach to the construction of safety-critical digital controllers. Instead of directly constructing a complete model and then trying to verify it, the designer can start with an initial abstract (think “sketch”) model plus the requirements, from which a correct concrete model is automatically synthesized. There is no need for post-hoc verification of required functional properties. Having tool to carry this out will significantly impact the nation’s ability to ensure the safety of high-consequence digital systems. The approach has been implemented in a prototype tool, along with a suite of examples, including ones that reflect actual problems faced by designers. Our approach operates on a variant of Statecharts developed at Sandia called Qspecs. Statecharts are a widely used formalism for developing concurrent reactive systems, supporting scalability through allowing state models containing composite states, which are the serial or parallel composition of substates which can themselves contain statecharts. Statecharts enable an incremental style of development, in which states are progressively refined to incorporate greater detail in an incremental model of software development. Our approach formulates a set of constraints from the structure of the models and the requirements and propagates these constraints to a fixpoint. The solution to the constraints is an inductive invariant along with guards on the transitions. We also show how our approach extends to implementation refinement, decomposition, composition, and elaboration. We currently handle safety requirements written in LTL (Linear Temporal Logic)

42 ENGINEERING↗

Epoxy Adhesives for Stator Magnet Assembly in Stirling Radioisotope Generators (SRG)

As NASA seeks to fulfill its goals of exploration and understanding through missions planned to visit the moons of Saturn and beyond, a number of challenges arise from the idea of deep space flight. One of the first problems associated with deep space travel is electrical power production for systems on the spacecraft. Conventional methods such as solar power are not practical because efficiency decreases substantially as the craft moves away from the Sun. The criterion for power generation during deep space missions are very specific, the main points requiring high reliability, low mass, minimal vibration and a long lifespan. A Stirling generator, although fairly old in concept, is considered to be a potential solution for electrical power generation for deep space flight. A Stirling generator works on the same electromagnetic principles of a standard generator, using the linear motion of the alternator through the stationary stator which produces electric induction. The motion of the alternator, however, is produced by the heating and cooling dynamics of pressurized gases. Essentially heating one end and cooling another of a contained gas will cause a periodic expansion and compression of the gas from one side to the other, which a displacer translates into linear mechanical motion. NASA needs to confirm that the materials used in the generator will be able to withstand the rigors of space and the life expectancy of the mission. I am working on the verification of the epoxy adhesives used to bond magnets to the steel lamination stack to complete the stator; in terms of in-service performance and durability under various space environments. Understanding the proper curing conditions, high temperature properties, and degassing problems as well as production difficulties are crucial to the long term success of the generator. system and steel substrate used in the stator. To optimize the curing conditions of the epoxies, modulated differential scanning calorimetry analysis was done as a function of cure time and temperatures. Adhesion bond strength was tested at various temperatures with lap shear samples using Hiperco 50 substrate to ensure that the proper adhesive is being used. To try and solve the problem of bondline thickness, micro glass beads of 0.0017" in diameter were investigated to see if any other physical properties of the epoxy were affected. Efforts will be made to develop a standard, optimized, fabrication process/procedure of sub-scale magnet-stator assemblies for various adhesive performance evaluation studies under simulated generator conditions. Also, accelerated aging testing will be done in a pressurized canister with stator assembly samples for three years to verify if any degassing or thermal degradation of the epoxy occurs. The necessity of verifying the correct epoxy adhesive system for the stator magnet in the SRG is crucial because failure of the stator assembly would jeopardize the electrical system, and thereby the entire mission itself. My work involves specimen fabrications, testing, and data analyses of the epoxy adhesive system for the stator magnet in the SRG is crucial because failure of the stator assembly would jeopardize the electrical system, and thereby the entire mission itself.

Cater, George M.↗

Library for RF Interactions in Orbit Following Codes

A new code-library has been developed to handle quasi-linear wave particle interactions in orbit following Monte Carlo codes, RFOF (RF interactions in Orbit Following codes). This library will enable a large number of orbit following codes to model fast ion acceleration during ICRF and Lower Hybrid heating. The RFOF consists of two main modules: one evaluates the resonance condition, the other the resulting RF acceleration. The resonance condition is tested at each step along the orbit and the location of the next upcoming resonance is predicted. When a particle reaches the resonance, a quasi-linear acceleration is calculated with a novel Monte Carlo technique that avoids the time-consuming evaluation of phase-space derivatives of the interaction strength. In RFOF the wave-particles interactions are assumed to be localized to a single point on the orbit. This is often valid for the ion cyclotron and lower hybrid frequency ranges, but prevents the treatment of bounce and precessional resonances. The RFOF has been developed within the European Task Force for Integrated Tokamak Modelling, enabling interaction between experts in different fields. As a result the code is designed with a simple and generic interface, with a minimum of assumptions on e.g. the geometry. Successful integration with the two orbit following codes, ASCOT and SPOT, has already been demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical and biological studies with protons and HZE particles in a NASA supported research center in radiation health

NASA has established and supports a specialized center for research and training (NSCORT) to specifically address the potential deleterious effects of HZE particles on human health. The NSCORT in radiation health is a joint effort between Lawrence Berkeley National Laboratory (LBNL) and Colorado State University (CSU). The overall scope of research encompasses a broad range of subjects from microdosimetric studies to cellular and tissue responses to initial damage produced by highly energetic protons and heavy charged particles of the type found in galactic cosmic rays (GCR) spectrum. The objectives of the microdosimetry studies are to determine the response of Tissue Equivalent Proportional Counter (TEPC) to cosmic rays using ground based accelerators. This includes evaluation of energy loss due to the escape of high-energy delta rays and increased energy deposition due to the enhanced delta ray production in the wall of the detector. In this report major results are presented for 56Fe at 1000, 740, 600 and 400 MeV/nucleon. An assessment of DNA repair and early development of related chromosomal changes is extremely important to our overall understanding of enhanced biological effectiveness of high LET particle radiation. Results are presented with respect to the fidelity of the rejoining of double strand breaks and the implications of misrejoining. The relationship between molecular and cytogenetic measurements is presented by studying damage processing in highly heterochromatic supernumerary (correction of sypernumerary) X chromosomes and the active X-chromosome. One of the important consequences of cell's inability to handle DNA damage can be evaluated through mutation studies. Part of our goal is the assessment of potential radioprotectors to reduce the mutation yield following HZE exposures, and some promising results are presented on one compound. A second goal is the integration of DNA repair and mutation studies. Results are presented on a direct comparison of initial double strand breaks induction, the time course and fidelity of double strand break rejoining, cell killing and mutation induction in the same human model system. In order to understand the carcinogenic potential of protons and HZE particles, the role of damaged microenvironment in this process must be understood. In this project it has been postulated that radiation affects the microenvironment, which then modifies cell interactions in a manner conducive to neoplastic progression. Both TGF-beta and FGF-2 are important components of microenvironment. A recent result on the assessment of the role of FGF-2 and its cross-talk with TGF-beta as a function of radiation quality is presented. Theoretical modeling has so far played a central role in analyzing and integrating experimental data on repair and mutation studies and predicting new phenomena. The integrated NSCORT program also provides a broad training experience for students and postdoctoral fellows in space radiation health.

NASA Discipline Radiation Health↗

Induction of genomic instability in TK6 human lymphoblasts exposed to 137Cs gamma radiation: comparison to the induction by exposure to accelerated 56Fe particles

The induction of genomic instability in TK6 human lymphoblasts by exposure to (137)Cs gamma radiation was investigated by measuring the frequency and characteristics of unstable clones isolated approximately 36 generations after exposure. Clones surviving irradiation and control clones were analyzed for 17 characteristics including chromosomal aberrations, growth defects, alterations in response to a second irradiation, and mutant frequencies at the thymidine kinase and Na(+)/K(+) ATPase loci. Putative unstable clones were defined as those that exhibited a significant alteration in one or more characteristics compared to the controls. The frequency and characteristics of the unstable clones were compared in clones exposed to (137)Cs gamma rays or (56)Fe particles. The majority of the unstable clones isolated after exposure to either gamma rays or (56)Fe particles exhibited chromosomal instability. Alterations in growth characteristics, radiation response and mutant frequencies occurred much less often than cytogenetic alterations in these unstable clones. The frequency and complexity of the unstable clones were greater after exposure to (56)Fe particles than to gamma rays. Unstable clones that survived 36 generations after exposure to gamma rays exhibited increases in the incidence of dicentric chromosomes but not of chromatid breaks, whereas unstable clones that survived 36 generations after exposure to (56)Fe particles exhibited increases in both chromatid and chromosome aberrations.

Non-NASA Center↗

Effects of heavy ion to the primary culture of mouse brain cells

To investigate effects of low dose heavy particle radiation to CNS system, we adopted mouse neonatal brain cells in culture being exposed to heavy ions by HIMAC at NIRS and NSRL at BNL. The applied dose varied from 0.05 Gy up to 2.0 Gy. The subsequent biological effects were evaluated by an induction of apoptosis and neuron survival focusing on the dependencies of the animal strains, SCID, B6, B6C3F1, C3H, used for brain cell culture, SCID was the most sensitive and C3H the least sensitive to particle radiation as evaluated by 10% apoptotic criterion. The LET dependency was compared with using SCID and B6 cells exposing to different ions (H, C, Ne, Si, Ar, and Fe). Although no detectable LET dependency was observed in the high LET (55-200 keV/micrometers) and low dose (<0.5 Gy) regions. The survivability profiles of the neurons were different in the mouse strains and ions. In this report, a result of memory and learning function to adult mice after whole-body and brain local irradiation at carbon ion and iron ion.

NASA Discipline Radiation Health↗

Effect of driver impedance on dense plasma focus Z-pinch neutron yield

The Z-pinch phase of a dense plasma focus (DPF) heats the plasma by rapid compression and accelerates ions across its intense electric fields, producing neutrons through both thermonuclear and beam-target fusion. Driver characteristics have empirically been shown to affect performance, as measured by neutron yield per unit of stored energy. We are exploring the effect of driver characteristics on DPF performance using particle-in-cell (PIC) simulations of a kJ scale DPF. In this work, our PIC simulations are fluid for the run-down phase and transition to fully kinetic for the pinch phase, capturing kinetic instabilities, anomalous resistivity, and beam formation during the pinch. The anode-cathode boundary is driven by a circuit model of the capacitive driver, including system inductance, the load of the railgap switches, the guard resistors, and the coaxial transmission line parameters. It is known that the driver impedance plays an important role in the neutron yield: first, it sets the peak current achieved at pinch time; and second, it affects how much current continues to flow through the pinch when the pinch inductance and resistance suddenly increase. Here we show from fully kinetic simulations how total neutron yield depends on the impedance of the driver and the distributed parameters of the transmission circuit. Direct comparisons between the experiment and simulations enhance our understanding of these plasmas and provide predictive design capability for neutron source applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-403: Measurement of the Neutron Ambient Dose Equivalent From the TrueBeam Linac Head and Varian 2100 Clinac

Purpose: High-energy x-ray therapy produces an undesirable source of stray neutron dose to healthy tissues, and thus, poses a risk for second cancer induction years after the primary treatment. Hence, the purpose of this study was to measure the neutron ambient dose equivalent, H*(10), produced from the TrueBeam and Varian 2100 linac heads, respectively. Of particular note is that there is no measured data available in the literature on H*(10) production from the TrueBeam treatment head. Methods: Both linacs were operated in flattening filter mode using a 15 MV x-ray beam on TrueBeam and an 18 MV x-ray beam for the Varian 2100 Clinac with the jaws and multileaf collimators in the fully closed position. A dose delivery rate of 600 MU/min was delivered on the TrueBeam and the Varian 2100 Clinac, respectively and the H*(10) rate was measured in triplicate using the WENDI-2 detector located at multiple positions including isocenter and longitudinal (gun-target) to the isocenter. Results: For each measurement, the H*(10) rate was relatively constant with increasing distance away from the isocenter with standard deviations on the order of a tenth of a mSv/h or less for the given beam energy. In general, fluctuations in the longitudinal H*(10) rate between the anterior-posterior couch directions were approximately a percent for both beam energies. Conclusion: Our preliminary results suggest an H*(10) rate of about 30 mSv/h (40 mSv/h) or less for TrueBeam (Varian Clinac 2100) for all measurements considered in this study indicating a relatively low contribution of produced secondary neutrons to the primary therapeutic beam.

60 APPLIED LIFE SCIENCES↗

Radiogenic transformation of human mammary epithelial cells in vitro

Cancer induction by space radiations is a major concern for manned space exploration. Accurate assessment of radiation risk at low doses requires basic understanding of mechanism(s) of radiation carcinogenesis. For determining the oncogenic effects of ionizing radiation in human epithelial cells, we transformed a mammary epithelial cell line (185B5), which was immortalized by benzo(a)pyrene, with energetic heavy ions and obtained several transformed clones. These transformed cells showed growth properties on Matrigel similar to human mammary tumor cells. To better understand the mechanisms of radiogenic transformation of human cells, we systematically examined the alterations in chromosomes and cancer genes. Among 16 autosomes examined for translocations, by using fluorescence in situ hybridization (FISH) technique, chromosomes 3, 12, 13, 15, 16, and 18 appeared to be normal in transformed cells. Chromosomes 1, 4, 6, 8, and 17 in transformed cells, however, showed patterns different from those in nontransformed cells. Southern blot analyses indicated no detectable alterations in myc, ras, Rb, or p53 genes. Further studies of chromosome 17 by using in situ hybridization with unique sequence p53 gene probe and a centromere probe showed no loss of p53 gene in transformed cells. Experimental results from cell fusion studies indicated that the transforming gene(s) is recessive. The role of genomic instability and tumor suppressor gene(s) in radiogenic transformation of human breast cells remains to be identified.

NASA Center JSC↗