Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lighting quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

X-ray wavefront sensor development at the Advanced Light Source

At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.

Goldberg, Kenneth A↗

Leveraging Afterglow in Scintillation-based x-ray detectors for spacetime-resolved computed tomography for accelerated acquisition and high-speed event capture

Afterglow in x-ray imaging for high-speed radiography is a constraint that limits imaging systems to low-light/fast decay screens which create poor data. Current approaches focus purely on using low-light yield screens with fast decay to avoid multiple exposure pileup due to afterglow. The goal of this work is to develop a statistical estimation approach to leverage afterglow to improve image quality thus allowing for higher quality imaging components to be used. This will allow for bright screens will slow decay to be used, and then a post-processing step applies the statistical estimation to separate each frame with superior signal compared to low-light/fast decay screens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of an interlaboratory study on the working curve in vat photopolymerization II: Towards a standardized method

The working curve measurement in photopolymer additive manufacturing is a ubiquitous measure of the cure depth of a printing resin as a function of radiant exposure of light. The fit parameters from this measurement (the depth of light penetration D p and the critical exposure E c ) are used to evaluate and report a resin’s printability, optimize processing parameters, and inform print and resin quality control. Despite its widespread use, the working curve lacks a standard measurement method. Here, following up on our paper “Results of an Interlaboratory Study on the Working Curve in Vat Photopolymerization” from last year, an interlaboratory study on the working curve was performed using calibrated, reproducible, bandpass filtered light sources. With these light sources, the variability between labs in measured working curves was dramatically reduced from the initial interlaboratory study. Aggregate data from this experiment produced reliable D p and E c measurements at 385 nm of 39.2 ± 3.7 µm and 12.3 ± 3.0 mJ cm −2 , respectively. At 405 nm the values of D p and E c are 69.3 ± 3.8 µm and 17.9 ± 2.3 mJ cm −2 , respectively. The results are agnostic to the thickness measurement tool utilized by participants, ensuring broad applicability across laboratories. We also tested the generalizability of the proposed method of using a filtered light source by filtering a commercial 405 nm light source and obtaining a working curve in agreement with the aggregate data from the interlaboratory study. This interlaboratory study provides a basis for a documentary standard for the working curve, so that the entire photopolymer additive manufacturing industry can share reproducible and interoperable working curve data.

36 MATERIALS SCIENCE↗

Measuring Thickness-Dependent Relative Light Yield and Detection Efficiency of Scintillator Screens

Digital camera-based neutron imaging systems consisting of a neutron scintillator screen optically coupled to a digital camera are the most common digital neutron imaging system used in the neutron imaging community and are available at any state-of-the-art imaging facility world-wide. Neutron scintillator screens are the integral component of these imaging system that directly interacts with the neutron beam and dictates the neutron capture efficiency and image quality limitations of the imaging system. This work describes a novel approach for testing neutron scintillators that provides a simple and efficient way to measure relative light yield and detection efficiency over a range of scintillator thicknesses using a single scintillator screen and only a few radiographs. Additionally, two methods for correlating the screen thickness to the measured data were implemented and compared. An example 6LiF:ZnS scintillator screen with nominal thicknesses ranging from 0–300 μm was used to demonstrate this approach. The multi-thickness screen and image and data processing methods are not exclusive to neutron scintillator screens but could be applied to X-ray imaging as well. This approach has the potential to benefit the entire radiographic imaging community by offering an efficient path forward for manufacturers to develop higher-performance scintillators and for imaging facilities and service providers to determine the optimal screen parameters for their particular beam and imaging system.

42 ENGINEERING↗

Optically Induced Static Magnetization in Metal Halide Perovskite for Spin‐Related Optoelectronics

Abstract Understanding the feasibility to couple semiconducting and magnetic properties in metal halide perovskites through interface design opens new opportunities for creating the next generation spin‐related optoelectronics. In this work, a fundamentally new phenomenon of optically induced magnetization achieved by coupling photoexcited orbital magnetic dipoles with magnetic spins at perovskite/ferromagnetic interface is discovered. The depth‐sensitive polarized neutron reflectometry combined with in situ photoexcitation setup, constitutes key evidence of this novel effect. It is demonstrated that a circularly polarized photoexcitation induces a stable magnetization signal within the depth up to 7.5 nm into the surface of high‐quality perovskite (MAPbBr 3 ) film underneath a ferromagnetic cobalt layer at room temperature. In contrast, a linearly polarized light does not induce any detectable magnetization in the MAPbBr 3 . The observation reveals that photoexcited orbital magnetic dipoles at the surface of perovskite are coupled with the spins of the ferromagnetic atoms at the interface, leading to an optically induced magnetization within the perovskite’s surface. The finding demonstrates that perovskite semiconductor can be bridged with magnetism through optically controllable method at room temperature in this heterojunction design. This provides the new concept of utilizing spin and orbital degrees of freedom in new‐generation spin‐related optoelectronic devices.

36 MATERIALS SCIENCE↗

Concept of circular-linear energy recovery accelerator to probe the energy frontier

Energy-frontier accelerators provide powerful tools performing high precision measurements confirming the fundamentals of the physics and broadening new research horizons. Such machines are either driven by circular or linear accelerators. The circular machines, having the centre-of-mass (CM) energy values reaching 200 GeV (for leptons) and above, experience beam energy loss and quality dilution, for example, due to synchrotron radiation, limiting the overall CM energy achievable and requiring a constant energy top-up to compensate the loss and the beam quality dilution. Linear colliders overcome these limitations, while the finite capabilities of generating high average current beams limits the luminosity. This is partially compensated by the quality of the colliding beams. In this work, we suggest a novel design of circular-linear accelerator based on the merging of the “non-emitting”, low-energy storage rings and energy recovery linear accelerators. We suggest using the recently considered dual-axis asymmetric cavities to enable the operation of such a system, and in particular the energy recovery from spent, high-intensity beams. The machine considered, under the scope of the SNOWMASS-2021 initiative, can be potentially used to reach ultimate energy frontiers in high-energy physics as well as to drive next generation light sources. The merging of circular and linear systems, and applications of dual axes cavities, should allow the maintaining of high beam quality, high luminosity, and high energy efficiency, while offering a flexible energy management and opening clear opportunity for reducing the running cost. We note that the numbers shown in the paper are for illustration purpose and can be improved further.

43 PARTICLE ACCELERATORS↗

Detection of Critical Surface Features in PTLs and GDLs for Improved Device Performance and Manufacturing Reliability

High points, or features that protrude above the surface of the material, on porous transport layers (PTLs) and gas diffusion layers (GDLs) can be critical features that may affect the manufacturing process and the performance of the device containing the feature. High points on PTLs and GDLs may stress the membrane of a polymer electrolyte membrane (PEM) during lamination and cell operation of a PEM electrolyzer or fuel cell. Additionally, high points on GDLs may impact the reliability of the manufacturing process. Thus, understanding these critical features and developing procedures to detect them are a key part of developing quality control techniques for PTLs and GDLs. This work evaluates the effectiveness of the Keyence VR6200 benchtop-scale structured light optical profilometer for detection of surface protrusions on PTLs and GDLs. Standard testing procedures for detecting and measuring high points were created for use on both material types. These procedures were evaluated using Gage Repeatability and Reproducibility (Gage R&R), where the repeatability, reproducibility, and effectiveness of the system to detect and measure high points were quantified. We have shown with high statistical power that the system is very effective in detection and measurement of high points, with Gage R&R contributions measured to be 2.2% and 3.6% for PTLs and GDLs, respectively.

36 MATERIALS SCIENCE↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

High spatial resolution and contrast radiography of hydrodynamic instabilities at the National Ignition Facility

In this work, we are developing techniques for studying the Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high-energy-densities at the National Ignition Facility (NIF). In particular, through the improvement of experimental imaging quality, we are progressing toward the study of the turbulent regime of the mixing regions in capsule implosion experiments for inertial confinement fusion, which requires few micrometers resolution. Using 60 NIF beams, a solid shock tube is driven launching a shock wave that crosses the interface between a dense and a light material pre-machined in the target to obtain sinusoidal ripples, which results in RM and RT instabilities that are imaged using the NIF Crystal Backlighter Imager. High-quality images were obtained with a mean resolution of 7 μm and improved contrast. While the obtained resolution does not allow the observation of the smallest scale of the “turbulent” energy spectrum, the generated image encompasses 63% of the total flow energy, a 50% improvement over previous studies, which is observed for the first time a roll-up feature in a high energy density-type RT experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel methodology to integrate outcomes regarding perioperative pain experience into a composite score: Prediction model development and validation

Abstract Background An integrated score that globally assesses perioperative pain experience and rationally weights each component has not yet been developed. Methods A development dataset specific to adult Chinese patients undergoing orthopaedic surgery was obtained from PAIN OUT (1985 qualified patients of 2244). A more recent validation dataset obeying the same conditions was obtained from the Chinese Anaesthesia Shared‐database Platform (1004 qualified patients of 1032). Outcomes were assessed using the International Pain Outcomes Questionnaire (IPO‐Q), which comprises key patient‐level outcomes of perioperative pain management, including pain experience and perceptions of care. Using principal component analysis and regression models, a composite score (CS) was inferred to integrate pain experience. The discrimination of the CS for dissatisfaction and desire for more pain treatment was compared with that of the worst pain score. Results A CS was developed from the 12 items of the IPO‐Q regarding pain experience. The weight for calculating the CS was worst pain 11, least pain 17, time spent in severe pain 11, interference with activity in bed 9, interference with breathing deeply or coughing 10, interference with sleep 9, anxiety 12, helplessness 12, nausea 0, drowsiness 2, itch 5 and dizziness 2. In external validation, the CS indicated superior discrimination to the worst pain in predicting dissatisfaction ( p < 0.001) and desire for more pain treatment ( p < 0.001). Conclusions This study introduced a methodology to integrate outcomes regarding perioperative pain experience into a CS, which was based on the weight of each item. Significance This novel methodology sheds additional light on the riveting issue of carefully integrating several measures into a composite endpoint, which may be useful for quality improvement purposes when addressing the impact of a change in clinical practice.

Jiang, Bailin↗

Achieving extreme light confinement in low-index dielectric resonators through quasi-bound states in the continuum

Obtaining large field enhancement in low-refractive-index dielectric materials is highly relevant to many photonic and quantum optics applications. However, confining light in these materials is challenging, owing to light leakage through coupling to continuum modes in the surrounding environment. Here, we investigate the possibility of achieving high quality factors in low-index dielectric resonators through the bound states in the continuum (BIC). Our simulations demonstrate that destructive interference between leaky modes can be achieved by tuning the geometrical parameters of the resonator arrays, leading to the emergence of quasi-BIC in resonators that have a small index contrast to the underlying substrates. The resultant large field enhancement gives rise to giant quality factors and Purcell effects. By introducing vertical mirror symmetry, the quasi-BIC can be tuned into an ideal BIC. In addition, the quasi-BIC can modify the emission patterns of the coupled emitters, rendering highly directional and focused far-field emission. These findings may provide a path for the practical implementation of photonic and quantum devices based on low-index dielectric materials.

42 ENGINEERING↗

Multi-Beam-Energy Control Unit Based on Triple-Bend Achromats

X-ray free electron lasers (XFELs) are the new generation of particle accelerator-based light sources, capable of producing tunable, high-power X-ray pulses that are increasingly vital across various scientific disciplines. Recently, continuous-wave (CW) XFELs driven by superconducting linear accelerators have garnered significant attention due to their ability to enhance availability by supporting multiple undulator lines simultaneously. In this paper, we introduce a novel delay system comprising four triple-bend achromats (TBAs). This delay system was combined with fast kickers and can be employed to generate electron beams on a bunch-to-bunch basis in a CW-XFEL facility. Based on the parameters of the Shanghai High-Repetition-Rate XFEL and Extreme Light Facility, start-to-end simulations demonstrate that the TBA-based delay system achieves excellent electron beam qualities while providing a wide beam-energy-tuning range from 1.39 to 8 GeV.

43 PARTICLE ACCELERATORS↗

Advanced flip-coil system for magnetic field integral measurements of insertion devices

A novel flip-coil measurement system has been developed for the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory. This paper describes the design, implementation, and commissioning of the new measurement bench, highlighting its key features, including improved mechanical stability, advanced data acquisition, and enhanced reproducibility. The system enables precise characterization of field integrals and multipole components, ensuring the optimal performance of Insertion Devices (IDs) before installation in the NSLS-II storage ring. The flip-coil system incorporates an innovative approach to minimize mechanical and electrical errors, which significantly improves the reproducibility of measurements. In addition, the system features a state-of-the-art data acquisition system that enables real-time monitoring and analysis, further enhancing the efficiency and accuracy of the measurement process. Furthermore, preliminary tests have demonstrated that the new system meets the stringent requirements for magnetic field characterization of advanced insertion devices, making it an essential tool for future ID commissioning and quality assurance at NSLS-II.

36 MATERIALS SCIENCE↗

Dicyanobenzothiadiazole (DCBT) Organic Dye as a Visible Light Absorbing Strong Photoinduced Oxidant with a 16 Microsecond Long–Lived Excited State

Strong photoinduced oxidants are important to organic synthesis and solar energy conversion, to chemical fuels or electric. For these applications, visible light absorption is important to solar energy conversion and long–lived excited states are needed to drive catalysis. With respect to these desirable qualities, a series of five 5,6–dicyano[2,1,3]benzothiadiazole (DCBT) dyes are examined as organic chromophores that can serve as strong photooxidants in catalytic systems. The series utilizes a DCBT core with aryl groups on the periphery with varying electron donation strengths relative to the core. The dyes are studied via both steady–state and transient absorption and emission studies. Additionally, computational analysis, voltammetry, crystallography, and absorption spectroelectrochemistry are also used to better understand the behavior of these dyes. Ultimately, a strong photooxidant is arrived at with an exceptionally long excited state lifetime for an organic chromophore of 16 µs. Finally, the long–lived excited state photosensitizer is well–suited for use in catalysis, and visible light driven photosensitized water oxidation is demonstrated using a water–soluble photosensitizer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photosynthetic Antenna Research Center (PARC) (Final Report)

The Photosynthetic Antenna Research Center (PARC) was funded for five years (2009-2014) with the initial group of Energy Frontier Research Centers (EFRCs) by the U.S. Department of Energy. The PARC grant was then renewed for four more years (2014-2018). PARC was focused on basic scientific research aimed at elucidating the fundamental principles that underlie light harvesting and energy funneling in natural photosynthetic antennas and translating those principles into construction of biohybrid and bioinspired architectures to form the basis for next-generation systems for solar-energy conversion. PARC carried out high quality fundamental science on the path towards ambitious, visionary goals. The resources, infrastructure, and melding of scientific subdisciplines, techniques, and experiences made possible in PARC resulted in high risk but high reward and high impact research, enabling conceptual breakthroughs in light harvesting. PARC’s broad global vision was addressed through specific research and educational activities, and the legacy of intellectual and technical capacity that it built.

14 SOLAR ENERGY↗

Evaluation of integrated daylighting and electric lighting design projects: Lessons learned from international case studies

This article presents and discusses the lessons learned from the monitoring of 25 integrated daylighting and electric lighting international case study projects. The case studies consist of real occupied buildings that have been monitored as part of the International Energy Agency (IEA) SHC Task 61/EBC Annex 77 Programme. The general goal of the case studies was to balance lighting energy use with occupants’ visual and non-visual requirements. This was achieved using innovative solutions for daylighting and electric lighting with advanced controls, but also implementing simple and out-of-the-box strategies. The findings suggest that energy demands for lighting can significantly be reduced by combining sensible daylight provision, efficient lighting sources, and advances in controls. Yet, the effective achievement of project goals requires adequate monitoring, fine-tuning, and verification. The findings also suggest that the adoption of “integrative” lighting – that is, lighting systems that address both visual and non-visual responses – is getting increasingly popular. Catering to non-visual requirements will likely drive further innovation in lighting technology. Currently, there is limited investment available for developing daylighting systems for integrative lighting, and the current related electric strategies often come at the risk of energy rebound effects. Overall, providing daylighting and understanding user requirements are fundamental steps towards achieving quality projects, with potential benefits beyond saving energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗