Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light field imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Neutron Transmission Imaging with a Portable D-T Neutron Generator

Fast-neutron transmission imaging provides complementary information to x-ray transmission imaging. While fast neutron imaging resolution is generally below x-ray imaging, 14-MeV neutrons have an advantage over portable x-ray systems. Neutrons have higher transmission through high-Z materials due to a more uniform attenuation as a function of material atomic number Z compared to X-rays, and can therefore image low-Z materials inside high-Z materials. As a result, portable neutron transmission imaging has many applications, including inspection of concrete and welds for corrosion in vehicles, bridges, and other infrastructure, measurement of material levels in containers, and inspection of suspicious packages. Fast-neutron imaging is also more practical for field use than thermal-neutron imaging due to the size and shielding requirements typical of thermal-imaging systems compared to the availability of small 14.1 MeV D-T neutron generators. However, there are limitations in portable fast-neutron imaging systems, including limited neutron output, limited light produced by neutron scintillators, and lower resolution due to neutron source spot size and 2-3 mm scintillator thickness. In addition, digital-panel dark-noise is roughly 100x higher than neutron scintillator light, and variations in noise across the panel and in time is comparable to the imaging signal. Here we discuss recent efforts in developing a portable fast-neutron radiography system, including an improved neutron scintillator, mitigation of panel noise, and new commercial portable D-T neutron generators. We also present MCNP efforts to model neutron imaging, including scintillator resolution and the effects of neutron scattering from the object and surrounding materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting for digital image correlation speckle inversion at high temperature using color cameras

Digital image correlation (DIC) is a popular, noncontacting technique to measure full-field deformation by using cameras to track the motion of an applied surface pattern. Because it is noncontacting, DIC can be performed for extreme temperature applications (e.g., hot-fire rocket testing of carbon composite rocket nozzles) under harsh conditions during which bonded gauges are damaged. Speckle pattern inversion is a phenomenon that sometimes occurs while performing high-temperature DIC. During speckle pattern inversion, portions of the surface pattern that were initially darker at room temperature (e.g., graphite) may emit more light due to blackbody radiation than the portions that were initially paler, thereby producing images in which the pattern appears inverted at high temperature relative to the initial pattern at room temperature. This phenomenon can prevent the correlation algorithm from being able to resolve the displacements between images. This work compares three methods to mitigate speckle pattern inversion: (A) the subtraction method, a recently-published technique in which two high-temperature images are subtracted to remove unwanted light; (B) the filtering method, a popular technique in which optical bandpass filters screen out unwanted light; and (C) the histogram rescaling method, a proposed new method that pairs a color camera with a blue light source and uses information from the green sensor of the camera to correct against inversion in the blue sensor through postprocessing. The histogram rescaling method is shown to successfully eliminate speckle pattern inversion and has the added advantages that it does not require quasi-static loading to be able to compensate for speckle pattern inversion, nor does it impose thick-glass distortions caused by the optical filter.

Rowley, Lindsey J.↗

Detecting axion dark matter with black hole polarimetry

The axion, as a leading dark matter candidate, is the target of many ongoing and proposed experimental searches based on its coupling to photons. Ultralight axions that couple to photons can also cause polarization rotation of light which can be probed by the cosmic microwave background. In this work, we show that a large axion field is inevitably developed around black holes due to the Bose-Einstein condensation of axions, enhancing the induced birefringence effects. Therefore, measuring the modulation of supermassive black hole imaging polarization angles is a strong probe to the axion-photon coupling due to the formation of the axion condensation (axion star) which enhances the axion field. The oscillating axion field around black holes induces polarization rotation on the black hole image, which is detectable and distinguishable from astrophysical effects on the polarization angle, as it exhibits distinctive temporal variability and frequency invariability. In this work, we perform the theoretical calculation on the axion star formation rate and correspondingly the enhanced axion field value near supermassive black holes. Then, we present the range of axion-photon couplings within the axion mass range 10 − 21 – 10 − 16 eV that can be probed by the Event Horizon Telescope. The axion parameter space probed by black hole polarimetry will expand with the improvement in sensitivity on the polarization measurement and more black hole polarimetry targets with determined black hole masses. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light field X-ray optics

Devices, systems and methods for performing X-ray scans with a single line of sight using a lens array for capturing the light field of the X-rays are described. In one example aspect, an X-ray optical system includes a primary optics subsection positioned to receive incoming X-rays after traversal through an object and to redirect the received incoming X-rays onto an intermediate image plane. The system also includes a microlens array positioned at or close to the intermediate image plane to receive at least some of the received incoming X-rays after redirection by the primary optics subsection to diffract the X-rays that are incident thereupon.

Kozioziemski, Bernard J.↗

Simultaneous imaging of vibrational, rotational, and electronic wave-packet dynamics in a triatomic molecule

Light-induced molecular dynamics often involve the excitation of several electronic, vibrational, and rotational states. Since the ensuing electronic and nuclear motion determines the pathways and outcomes of photoinduced reactions, our ability to monitor and understand these dynamics is crucial for molecular physics, physical chemistry, and photobiology. However, characterizing this complex motion represents a significant challenge when different degrees of freedom are strongly coupled. In this Letter, we demonstrate how the interplay between vibrational, rotational, and electronic degrees of freedom governs the evolution of molecular wave packets in the low-lying states of strong-field-ionized sulfur dioxide. Using time-resolved Coulomb explosion imaging (CEI) and quantum mechanical wave packet simulations, we directly map the bending vibrations of the molecule, show how the vibrational wave packet is influenced by molecular alignment, and elucidate the consequences of nuclear motion for the coupling between the two lowest electronic states of the cation. Furthermore, our results demonstrate that multicoincident CEI can be an efficient experimental tool for characterizing coupled electronic and nuclear motion in polyatomic molecules.

Atomic & molecular processes in external fields↗

3P Program: Phenotyping X Prediction = Productivity (Final Scientific/Technical Report)

The goal of the 3P Program was to establish integrated, real-time phenotyping and to analyze above- and below-ground plant architecture and total carbon partitioning and allocation to predict heterosis and develop superior crop hybrids by fully leveraging the Sorghum gene pool. There were two overarching themes: 1) the development of a new crop improvement approach utilizing advances in high-throughput phenotyping (HTP), computing, and genomics for public dissemination and 2) leveraging this platform for sorghum crop improvement and commercialization. The Clemson team worked on creating genomic resources and using both statistical learning and high-throughput phenotyping in genomics-assisted breeding. Research was broadly interested in the genetics of carbon partitioning, with the aim of improving crop performance and achieving sustainability. The technology and resources created can be readily found in the public domain and serve to advance scientific understanding of crop genomics and breeding. Genomic prediction was able to identify top crosses to be made, and a hybrid prediction pipeline is in place to drive year-over-year genetic gain. Roots have long been ignored by plant breeders and agronomists, not because they are unimportant but because they are hard to measure. This is an untapped white space of potential insight and innovation. To address this, Hi Fidelity Genetics developed the RootTracker to measure roots in the field on a continuous basis. A database system called RootTracker Tracker was developed to handle data coming from the RootTrackers. In using this device, valuable data was observed for plant breeding, hydrochemical development, and other agricultural biology applications. Carnegie Mellon’s goal was developing new techniques to generate high-resolution 3D models of plants from data collected in the field. The idea was that more useful and more informative phenotypes could be extracted by resolving small features, such as seeds and flowers, and that by modeling in 3D, the spatial structure of plants could be examined. To achieve this, multiple images collected by a new small format structured light stereo imager were fused together. A sorghum panicle modeling pipeline was developed to allow the collection and processing of data. Carolina Seed Systems is an agricultural technology company focused on decarbonizing the agricultural system. Their technology pipeline serves to drive fundamental progress towards creation and distribution of carbon negative crops. The genomic and the engineering technology developed through the 3P Program was leveraged to deliver both value and sustainability from the grower to the consumer. Promising sorghum hybrids were scaled up and commercialized. The overall goal of our research was to integrate, create, and deploy genetic and engineering concepts and technologies to enhance crop productivity in a sustainable fashion. The combination of public and private partners allowed the basic research and hypothesis testing to be quickly accelerated for commercial application by the companies yet maintained that the core framework and academic insights remain in the public domain for continued market disruption, competition, and innovation.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting Axion Dark Matter with Black Hole Polarimetry

The axion, as a leading dark matter candidate, is the target of many on-going and proposed experimental searches based on its coupling to photons. Ultralight axions that couple to photons can also cause polarization rotation of light which can be probed by cosmic microwave background. In this work, we show that a large axion field is inevitably developed around black holes due to the Bose-Einstein condensation of axions, enhancing the induced birefringence effects. Therefore, we propose measuring the modulation of supermassive black hole imaging polarization angles as a new probe to the axion-photon coupling of axion dark matter. The oscillating axion field around black holes induces polarization rotation on the black hole image, which is detectable and distinguishable from astrophysical effects on the polarization angle, as it exhibits distinctive temporal variability and frequency invariability. We present the range of axion-photon couplings within the axion mass range $10^{-21}-10^{-16}\text{eV}$ that can be probed by the Event Horizon Telescope. The axion parameter space probed by black hole polarimetry will expand with the improvement in sensitivity on the polarization measurement and more black hole polarimetry targets with determined black hole masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fluorescence strobo-stereoscopy for specular reflection-suppressed full field of view imaging

This report introduces fluorescence strobo-stereoscopy (FSS) to suppress strong specular reflection and enable the full field of view (FFOV) 3D surface imaging while the part is rotating. Specular reflection off the target surface significantly degrades the image quality and becomes critical for highly reflective surface measurements. In FSS, the fluorescent dye-doped fluid applied on the machined surface is excited upon incident ultra-violet light and becomes a new light source by Stokes' Law. Thus, specular reflection off of smooth surface can be suppressed by separating the fluorescent light from the excitation light. The developed FSS comprises a pair of imaging cameras, spatial filters, and an excitation light source. As a result, FSS effectively rejected the specular reflection and improved the FFOV 3D surface image quality of the machined part by enhancing contrast in the rotating target surface. Such enhancements in 3D imaging allowed to identify manufacturing tolerance of the part and to detect the surface features. The axial and lateral accuracy errors of FSS were 2.3% and 1.4% with the target size of 4.07 mm and 0.215 mm, respectively. A whole view reconstruction of the cylindrical target sample was performed, and the corresponding cylindricity and diameter deviation were assessed. The fluid media effect and the target surface quality effect were discussed.

3D surface imaging↗

Tunable phase-change metasurfaces coupled with mid-infrared molecular vibrations

Chiral optical metasurfaces have emerged as a promising platform in coupling with molecular vibrational fingerprints through the enhanced light-matter interaction under different circularly polarized light illumination. Here, this work reports the mode coupling between the mid-infrared phonon vibrations of polymethyl methacrylate (PMMA) molecules and the thermally tunable chiral metasurfaces based on the phase-change material Ge₂Sb₂Te₅ (GST-225). Phase-change chiral metasurfaces with high circular dichroism (CD) in absorption and tunable plasmonic resonance in the frequency range of 48–56 THz are demonstrated, which covers the phonon vibrational frequency of PMMA molecules at 52 THz. The mode splitting features are observed in the absorption and CD spectra when the metasurface resonance is tuned across the phonon vibrational frequency of PMMA molecules during the phase transition of GST-225. The underlying mechanism of molecule-metasurface coupling is further revealed by studying the electric field and power loss density distributions of the phonon–plasmon coupled modes under both left-handed and right-handed circularly polarized (LCP and RCP) light. The demonstrated results show the potential of dynamically tunable chiral metasurfaces for the applications in label-free molecular sensing, biomedical diagnostics, thermal imaging, and mid-infrared photonics.

Tang, Haotian [Missouri Univ. of Science and Techn↗

Ptychography at all wavelengths

Ptychography is a computational imaging technique that operates across multiple wavelength regimes, from electron (picometres) to X-ray (~0.1 nm), extreme ultraviolet (~10 nm) and visible light (micrometres). By reconstructing both amplitude and phase from diffraction patterns, ptychography enables high-resolution, quantitative imaging without conventional limitations imposed by lens-based optics. Ptychography has enabled advances across a range of scales: achieving deep-sub-angstrom resolution with electron microscopy, becoming an indispensable tool at X-ray synchrotron facilities worldwide and overcoming the trade-offs between resolution and field-of-view in optical imaging. This Primer provides a unified treatment of ptychography across these wavelength regimes. First, we discuss theoretical foundations, reconstruction algorithms, experimental considerations and wavelength-specific challenges. We then give examples of raw and processed data from various configurations and wavelengths. Next, we highlight key applications of ptychography in life sciences, materials science and industry. We also discuss data standards, open-source software implementations and best practices for ensuring reproducibility across different wavelength regimes. Finally, we consider limitations and future opportunities for ptychography. Together with accompanying datasets and code implementations, this Primer aims to serve newcomers and experienced practitioners in the field, facilitating broader adoption of ptychography across different disciplines.

47 OTHER INSTRUMENTATION↗

Future trends in synchrotron science at NSLS-II

In this paper, we summarize briefly some of the future trends in synchrotron science as seen at the National Synchrotron Light Source II, a new, low emittance source recently commissioned at Brookhaven National Laboratory. We touch upon imaging techniques, the study of dynamics, the increasing use of multimodal approaches, the vital importance of data science, and finally, other enabling technologies. Each are presently undergoing a time of rapid change, driving the field of synchrotron science forward at an ever increasing pace. It is truly an exciting time and one in which Roger Cowley, to whom this journal issue is dedicated, would surely be both invigorated by, and at the heart of.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗

Enhancing high-order harmonic generation by controlling the diffusion of the electron wave packet

We experimentally study the enhancement of high-order harmonic generation (HHG) driven by synthesized ω <#comment/> − <#comment/> 3 ω <#comment/> laser fields, where we control whether the ionization rate or the electron wave packet’s diffusion is the dominant enhancement mechanism. When minimizing the electron wave packet’s diffusion, the excursion times of the corresponding electron trajectories are reduced by a factor of 2 or more. This result is important for imaging techniques that use the returning electron wave packet to probe the remaining ion. Furthermore, we achieve a 10 × <#comment/> to 3800 × <#comment/> enhancement of the harmonic yield driven by the bichromatic fields relative to that of an optimized single-color field, showing that the bichromatic fields improve HHG’s capability as a light source. We also measure that the two-color field’s harmonics have half the divergence angle compared to their single-color counterpart, suggesting that the “short” electron trajectories play a more prominent role compared to their “long” trajectory counterparts, thus improving the wavefront of the emerging harmonic beam.

74 ATOMIC AND MOLECULAR PHYSICS↗

TDCOSMO - XVII. New time delays in 22 lensed quasars from optical monitoring with the ESO-VST 2.6m and MPG 2.2m telescopes

We present new time delays, the main ingredient of time delay cosmography, for 22 lensed quasars resulting from high-cadence r-band monitoring on the 2.6 m ESO VLT Survey Telescope and Max-Planck-Gesellschaft 2.2 m telescope. Each lensed quasar was typically monitored for one to four seasons, often shared between the two telescopes to mitigate the interruptions forced by the COVID-19 pandemic. The sample of targets consists of 19 quadruply and 3 doubly imaged quasars, which received a total of 1918 hours of on-sky time split into 21 581 wide-field frames, each 320 seconds long. In a given field, the 5-σ depth of the combined exposures typically reaches the 27th magnitude, while that of single visits is 24.5 mag – similar to the expected depth of the upcoming Vera-Rubin LSST. The fluxes of the different lensed images of the targets were reliably de-blended, providing not only light curves with photometric precision down to the photon noise limit, but also high-resolution models of the targets whose features and astrometry were systematically confirmed in Hubble Space Telescope imaging. This was made possible thanks to a new photometric pipeline, lightcurver, and the forward modelling method STARRED. Finally, the time delays between pairs of curves and their uncertainties were estimated, taking into account the degeneracy due to microlensing, and for the first time the full covariance matrices of the delay pairs are provided. Of note, this survey, with 13 square degrees, has applications beyond that of time delays, such as the study of the structure function of the multiple high-redshift quasars present in the footprint at a new high in terms of both depth and frequency. The reduced images will be available through the European Southern Observatory Science Portal.Key words: methods: data analysis / surveys / distance scale

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative order-parameter measurement in lattice-mismatched AlInP using precession electron diffraction

Precession electron diffraction (PED) was used to measure the long-range order parameter in lattice-mismatched AlInP epitaxial films under investigation for solid-state-lighting applications. Both double- and single-variant films grown at 620, 650, and 680°C were analyzed in TEM cross-section. PED patterns were acquired in selected-area-diffraction mode through external microscope control using serial acquisition, which allows inline image processing. The integrated peak intensities from experimental patterns were fit using dynamical simulations of diffraction from the ordered domain structures. Included in the structure-factor calculations were mean atomic displacements of the anions (P) due to ordering, which were found by valence-force-field calculations to have a nearly linear dependence on order parameter. A maximum order parameter of S = 0.36 was measured for a double-variant specimen grown at 650°C.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

VLM4Bio: A Benchmark Dataset to Evaluate Pretrained Vision-Language Models for Trait Discovery from Biological Images

Images are increasingly becoming the currency for documenting biodiversity on the planet, providing novel opportunities for accelerating scientific discoveries in the field of organismal biology, especially with the advent of large vision-language models (VLMs). We ask if pre-trained VLMs can aid scientists in answering a range of biologically relevant questions without any additional fine-tuning. In this paper, we evaluate the effectiveness of 12 state-of-the-art (SOTA) VLMs in the field of organismal biology using a novel dataset, VLM4Bio, consisting of 469K question8 answer pairs involving 30K images from three groups of organisms: fishes, birds, and butterflies, covering five biologically relevant tasks. We also explore the effects of applying prompting techniques and tests for reasoning hallucination on the performance of VLMs, shedding new light on the capabilities of current SOTA VLMs in answering biologically relevant questions using images

Maruf, M [Virginia Tech, Blacksburg]↗

Evidence of Recent Material Transport within a Binary Asteroid System

Images acquired by the Double Asteroid Redirection Test (DART) before its impact into Dimorphos—the moon of the Didymos binary asteroid system—unexpectedly reveal a set of discontinuous rays spanning the imaged surface. These albedo features are visible only after correcting for lighting differences, which normalize the effects of the pervasive boulders that cover the surface. Comparison to physical experiments and numerical simulations shows that these bright, fan-shaped albedo features are consistent with the aftermath of a low-velocity impact into a field of boulders and provide our first direct evidence for the transfer of material in a binary asteroid system due to the shedding material from radiative torques. Parts of these and possible additional albedo markings from the reentry of boulders after the DART impact may be visible to the Hera mission when it explores the post-DART Didymos system.

Astronomy and AstroPhysics↗

A Skipper-CCD Light Shield for X-Ray Detection in Space

We present advancements in the design of Skipper-CCD sensors for X-ray detection in environments with high optical backgrounds, such as those expected in space. These packages incorporate a custom-made aluminum shield on the CCD surface that blocks over 99% of visible light while preserving the efficiency for keV X-rays. These features allow us to perform precise X-ray measurements in environments challenged by visible light interference. Furthermore, we briefly discuss the potential implementation of this design concept in frame-transfer CCDs, opening opportunities for broader applications and advancements in imaging technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗