Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leak test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Project Methods to Enhance Wellbore Cement Integrity with Microbially-Induced Calcite Precipitation (MICP) (Final Scientific/Technical Report)

The goal of this project was to develop improved methods for sealing compromised wellbore cement in leaking oil and gas wells, thereby reducing the risk of unwanted upward fluid migration. Novel methods for improving wellbore integrity, such as microbially induced calcite precipitation (MICP), can reduce leakage potential, improve the safety of fossil fuel extraction, improve the public perception of hydraulic fracturing, and promote environmentally-prudent unconventional oil and gas development. Microbes, with the urease enzyme, can catalyze the chemical reaction of urea hydrolysis to induce the precipitation of calcium carbonate which can be used as a cementitious material to seal leakage pathways. In this project, methods to promote robust bio-composite cementitious materials were designed and tested in the laboratory. Scale-up of those methods were tested in meso-scale reactor systems and in field applications. In this report, in Section One, we describe laboratory efforts to develop injection strategies to promote precipitation in wellbore analogs and determine the strength of the bio-composite cements as compared to fine cement. In Section Two, we describe the efforts to scale up the work and study the use of materials that can be used in field application, for example exploring the use of calcium chloride ice melt or urea fertilizer as source chemicals. In Section Three, the three field trials (methods and results) performed as part of the project are described and summarized. At the end of the report is a comprehensive summary and conclusion section which highlights the key findings of the project. The work performed during this project significantly advanced the technology readiness level (TRL) of the MICP wellbore sealing strategy.

02 PETROLEUM↗

Methods to Enhance Wellbore Cement Integrity with Microbially-Induced Calcite Precipitation (MICP) (Final Scientific/ Technical Report)

The goal of this project was to develop improved methods for sealing compromised wellbore cement in leaking oil and gas wells, thereby reducing the risk of unwanted upward fluid migration. Novel methods for improving wellbore integrity, such as microbially induced calcite precipitation (MICP), can reduce leakage potential, improve the safety of fossil fuel extraction, improve the public perception of hydraulic fracturing, and promote environmentally-prudent unconventional oil and gas development. Microbes, with the urease enzyme, can catalyze the chemical reaction of urea hydrolysis to induce the precipitation of calcium carbonate which can be used as a cementitious material to seal leakage pathways. In this project, methods to promote robust bio-composite cementitious materials were designed and tested in the laboratory. Scale-up of those methods were tested in meso-scale reactor systems and in field applications. In this report, in Section One, we describe laboratory efforts to develop injection strategies to promote precipitation in wellbore analogs and determine the strength of the bio-composite cements as compared to fine cement. In Section Two, we describe the efforts to scale up the work and study the use of materials that can be used in field application, for example exploring the use of calcium chloride ice melt or urea fertilizer as source chemicals. In Section Three, the three field trials (methods and results) performed as part of the project are described and summarized. At the end of the report is a comprehensive summary and conclusion section which highlights the key findings of the project. The work performed during this project significantly advanced the technology readiness level (TRL) of the MICP wellbore sealing strategy.

03 NATURAL GAS↗

Simplified Green-Ampt Model, Imbibition-Based Estimates of Permeability, and Implications for Leak-off in Hydraulic Fracturing

Predicting water imbibition into porous materials is important in a wide variety of fields, and hydraulic fracturing of low permeability hydrocarbon reservoirs has emerged as an application that is imposing a large water footprint. Furthermore, reliable predictions of imbibition are needed to better manage water use, yet are challenging because of uncertainties in both the permeability and capillary pressure driving force. Here, this uncertainty is reduced through evaluating correlations between the permeability and the effective capillary pressure associated with the wetting front, P c,f . These correlations allow elimination of P c,f from the Green and Ampt equation and concentrate all uncertainties in fluxes on the effective permeability k . Over a wide range of k and porosities n , imbibition scales approximately with k 1/3 . Although Leverett k 1/4 scaling for predicting P c,f is shown to be inferior when tested with data spanning a wide range of n , it nevertheless predicted imbibition fairly well. From simple imbibition measurements, both the empirical and Leverett scaling approaches allow estimates of k that have root-mean-square deviations of about one order of magnitude relative to measurements that ranged over 10 orders of magnitude in k .

58 GEOSCIENCES↗

Rock Physics-Based Data Assimilation of Integrated Continuous Active-Source Seismic and Pressure Monitoring Data during Geological Carbon Storage

Summary There has been substantial controversy concerning the role of geological carbon storage (GCS) in sequestering anthropogenic carbon emissions to mitigate climate change and global warming. Arguments center on the inability to monitor a geological storage site precisely and continuously, especially highlighting the associated costs and spatiotemporal trade-offs when using conventional subsurface monitoring techniques (well logs, core samples, chemical tracers, and 4D seismics). Active surveillance of GCS sites is essential for managing and mitigating potential leaks but is also required by regulation. With the goal of enhancing the monitoring capability at GCS sites, we present a rock physics-based joint data assimilation model to study a popular GCS site at Cranfield, Mississippi, USA. Synthetic continuous active-source seismic monitoring (CASSM) data (in the form of Vp and Qp measurements) and wellbore pressure monitoring data are assimilated with an ensemble of reservoir realizations to monitor gas saturation and reservoir pressure changes over a period of 100 years. Synthetic seismic attributes are generated using rock physics models (RPMs) and wellbore pressure monitoring data are extracted from the ground truth. Two assimilation methods, ensemble Kalman filter (EnKF) and ensemble Kalman smoother (EnKS), are tested in an observation system simulation experiment (OSSE) environment to assess the prediction accuracy of the individual and composite observation systems. The joint monitoring system achieves more accurate estimates of gas saturation and pressure, across the time span from start of injection to end of forecast, as compared to a single type of monitoring tool and irrespective of data assimilation algorithm choice. These results indicate that jointly assimilated data from two types of sensors (in this case, crosswell seismic and downhole pressure) may lead to a more risk-reducing monitoring design. One would expect that more data, vis-à-vis inclusion of a new sensor type, will improve the accuracy of any GCS monitoring system. However, from a practical standpoint, one important question is whether such a gain in accuracy is worth the additional cost associated with the new sensor. This paper focuses on quantifying the gain in accuracy, such that a practitioner can answer this question.

Engineering↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Drug-Inducible Gene Therapy Effectively Reduces Spontaneous Seizures in Kindled Rats but Creates Off-Target Side Effects in Inhibitory Neurons

Over a third of patients with temporal lobe epilepsy (TLE) are not effectively treated with current anti-seizure drugs, spurring the development of gene therapies. The injection of adeno-associated viral vectors (AAV) into the brain has been shown to be a safe and viable approach. However, to date, AAV expression of therapeutic genes has not been regulated. Moreover, a common property of antiepileptic drugs is a narrow therapeutic window between seizure control and side effects. Therefore, a long-term goal is to develop drug-inducible gene therapies that can be regulated by clinically relevant drugs. In this study, a first-generation doxycycline-regulated gene therapy that delivered an engineered version of the leak potassium channel Kcnk2 (TREK-M) was injected into the hippocampus of male rats. Rats were electrically stimulated until kindled. EEG was monitored 24/7. Electrical kindling revealed an important side effect, as even low expression of TREK M in the absence of doxycycline was sufficient to cause rats to develop spontaneous recurring seizures. Treating the epileptic rats with doxycycline successfully reduced spontaneous seizures. Localization studies of infected neurons suggest seizures were caused by expression in GABAergic inhibitory neurons. In contrast, doxycycline increased the expression of TREK-M in excitatory neurons, thereby reducing seizures through net inhibition of firing. These studies demonstrate that drug-inducible gene therapies are effective in reducing spontaneous seizures and highlight the importance of testing for side effects with pro-epileptic stressors such as electrical kindling. These studies also show the importance of evaluating the location and spread of AAV-based gene therapies in preclinical studies.

60 APPLIED LIFE SCIENCES↗

Open-source electrochemical cell for in situ X-ray absorption spectroscopy in transmission and fluorescence modes

X-ray spectroscopy is a valuable technique for the study of many materials systems. Characterizing reactions in situ and operando can reveal complex reaction kinetics, which is crucial to understanding active site composition and reaction mechanisms. In this project, the design, fabrication and testing of an open-source and easy-to-fabricate electrochemical cell for in situ electrochemistry compatible with X-ray absorption spectroscopy in both transmission and fluorescence modes are accomplished via windows with large opening angles on both the upstream and downstream sides of the cell. Using a hobbyist computer numerical control machine and free 3D CAD software, anyone can make a reliable electrochemical cell using this design. Onion-like carbon nanoparticles, with a 1:3 iron-to-cobalt ratio, were drop-coated onto carbon paper for testing in situ X-ray absorption spectroscopy. Cyclic voltammetry of the carbon paper showed the expected behavior, with no increased ohmic drop, even in sandwiched cells. Chronoamperometry was used to apply 0.4 V versus reversible hydrogen electrode, with and without 15 min of oxygen purging to ensure that the electrochemical cell does not provide any artefacts due to gas purging. The XANES and EXAFS spectra showed no differences with and without oxygen, as expected at 0.4 V, without any artefacts due to gas purging. The development of this open-source electrochemical cell design allows for improved collection of in situ X-ray absorption spectroscopy data and enables researchers to perform both transmission and fluorescence simultaneously. It additionally addresses key practical considerations including gas purging, reduced ionic resistance and leak prevention.

08 HYDROGEN↗

Incombustible Polymer Electrolyte Boosting Safety of Solid–State Lithium Batteries: A Review

Lithium-ion batteries with their portability, high energy density, and reusability are frequently used in today's world. Under extreme conditions, lithium-ion batteries leak, burn, and even explode. Therefore, improving the safety of lithium-ion batteries has become a focus of attention. Researchers believe using a solid electrolyte instead of a liquid one can solve the lithium battery safety issue. Due to the low price, good processability and high safety of the solid polymer electrolytes, increasing attention have been paid to them. However, polymer electrolytes can also decompose and burn under extreme conditions. Moreover, lithium dendrites are formed continuously due to the uneven charge distribution on the surface of the lithium metal anode. A short circuit caused by a lithium dendrite can cause the battery to thermal runaway. As a result, the safety of polymer solid-state batteries remains a challenge. In this review, the thermal runaway mechanism of the batteries is summarized, and the batteries abuse test standard is introduced. In addition, the recent works on the high-safety polymer electrolytes and the solution strategies of lithium anode problems in polymer batteries are reviewed. Finally, the development direction of safe polymer solid lithium batteries is prospected.

25 ENERGY STORAGE↗

Open Radiation Monitoring: Histogram Builder Module Design

The Open Radiation Monitoring Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. A modular architecture can be used to reduce more complex systems to a series of single purpose building blocks, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report details the first revision of a prototype circuit that will convert analog pulses directly into a histogrammed data set for further processing. The circuit was designed with both spectroscopy and multiplicity analysis in mind but can, in principle, be used to reduce any raw data stream into a histogram. The number of output channels is limited, and the histogram bin ranges are user configurable to allow for non-uniform and discontinuous bins, which makes it possible to restrict the information being passed down stream if desired. Pulse processing relies entirely on analog circuitry and non- programmable logic, which enables operation without the need for a central processor or other programmable control unit. The circuit remains untested under the Open Radiation Monitoring project due to the closure of the sponsoring program. However, further development and testing is scheduled to take place in support of a purpose-built trusted verification system development effort known as COGNIZANT, which demonstrates the potential benefit of developing a suite of modular trusted system components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CO 2 -Responsive Fracturing Fluids for Enhanced Geothermal Systems (Final Report)

Our group has recently developed StimuFrac, a non-toxic stimuli-responsive fracturing fluid consisting of a CO 2 -reactive polymer which has shown at the lab-scale to consistently fracture rock cores at significantly lower net pressures in a range of representative geothermal pressure/temperature conditions. However, until now the mechanism/s responsible for more effective fracturing, of critical importance to optimize fracturing performance as well as strategize injection methodologies for field deployment, was not understood. In this document, we report (1) on the two main mechanisms responsible for fracturing rock at lower net pressures with StimuFrac; (2) the phase behavior of StimuFrac/CO 2 under geothermal wellbore conditions; and (3) based on high-temperature true triaxial stimulations, detailed evidence that StimuFrac/CO 2 is the best performing stimulation fluid under EGS T/P conditions as compared to water, waterless CO 2 , and CO 2 /water fracturing fluids. This is because i) it requires significantly lower volumes of CO 2 due to its reduced leak off into the formation by the crosslinked polymer solution; ii) large fractures can be generated reproducibly at both low and high CO 2 injection flow rates, and iii) the reversible (previously reported) viscosity increase of StimuFrac could be beneficial to transport proppants when they become available for EGS. These results were particularly evident for hot nearly dry rock as well as partially and nearly fully water-saturated granitic rock. GTO requires StimuFrac to be evaluated in fully water-saturated rock to determine whether the above-described performance applies under these conditions. Since (1) GTO considers there is no enough evidence for Sa different StimuFrac formulation to work below 90C (where full water-saturation in an open system is possible) and (2) no polyaxial loading frame larger than a few centimeters that can do hydraulic fracturing tests while maintaining the rock sample fully saturated with water at 200 C exists; PNNL concludes that the only way to determine if StimuFrac represents an advanced fracturing fluid alternative for EGS, is to perform a stimulation in an actual EGS reservoir.

15 GEOTHERMAL ENERGY↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

History of Ultrasonic Inspection of High-Level Waste Tanks at SRS - 20220

The Liquid Waste Disposition Projects (LWDP) Structural Authority and Inspection Engineering Support Group has teamed with the Materials Science and Technology Non-destructive Evaluation Group of Savannah River National Laboratory (SRNL) to implement a comprehensive In-Service Inspection (ISI) program for the High-Level Waste (HLW) tanks in the sites tank farms. The purpose of this program is to demonstrate the structural and leak integrity of the tanks to maintain the function of waste containment throughout the desired service life. Four types of waste tanks were constructed at Savannah River Site (SRS) from 1951 thru 1981 to store radioactive nuclear waste from the separations process. The Type I, II and III are carbon steel cylindrical tanks with varying degrees of access to the side walls and very limited access to the tank bottom. The tanks contain 750,000 to 1.3 million gallons of waste and are buried or backfilled with soil. The tanks are 75'-85' in diameter and 24'-33' from tank bottom to the tank roof. Inspection of the HLW tanks is made difficult by radiation, contamination, and small access openings. Through the years these challenges have been overcome by progressive improvements to programs and equipment resulting in the sophisticated wall crawler Ultrasonic Testing (UT) technology of today. A formal inspection program was developed and put in service in 1972. UT thickness measurements were first made in 1967 and 1969 of selected waste tanks using an analog-type instrument to measure the thickness of the carbon steel walls. Routine inspections for thinning were performed from 1972-1985 and then discontinued because no thinning had been observed and this technique could not detect pitting or cracking. UT inspections resumed in 1994 using a sophisticated robotic wall crawler with UT technology capable of detecting thinning, cracking and pitting. The current program focuses on the newer Type III tanks that are used primarily for storage. The program was upgraded in 2003 to include selected regions of the tank wall, secondary wall and annulus floor on a 7 to 10-year frequency. The facility is currently in its third cycle of tank inspections. Thus far, there have been no reportable indications of service induced degradation. This result provides assurance that the chemistry control program has been effective at mitigating corrosion and that the tanks remain structurally sound even after more than 40 years of service. This paper will present the UT technology first used at SRS and the evolution to the current systems and their capabilities. Additionally, plans for equipment upgrades that will improve the extent of inspection will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of dispensing hardware for safe fueling of heavy duty vehicles

The development of safe dispensing equipment for the fueling of heavy duty (HD) vehicles is critical to the expansion of this newly and quickly expanding market. This paper discusses the development of a HD dispenser and nozzles assembly (nozzle, hose, breakaway) for these new, larger vehicles where flow rates are more than double compared to light duty (LD) vehicles. This equipment must operate at nominal pressures of 700 bar, -40o C gas temperature, and average flow rate of 5-10 kg/min at a high throughput commercial hydrogen fueling station without leaking hydrogen. The project surveyed HD vehicle manufacturers, station developers, and component suppliers to determine the basic specifications of the dispensing equipment and nozzle assembly. The team also examined existing codes and standards to determine necessary changes to accommodate HD components. From this information, the team developed a set of specifications which will be used to design the dispensing equipment. In order to meet these goals, the team performed computational fluid dynamic, pressure modelling, and temperature analysis in order to determine the necessary parameters to meet existing safety standards modified for HD fueling. The team also considered user, operational, and maintenance requirements, such as freeze lock which has been an issue which prevents the removal of the nozzle from LD vehicles. The team also performed a failure mode and effects analysis (FMEA) to identify the possible failures in the design. The dispenser and nozzle assembly will be tested separately, and then installed on an innovative, HD fueling station which will use a HD vehicle simulator to test the entire system.

08 HYDROGEN↗

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Wellbore Leakage Mitigation Using Advanced Mineral Precipitation Strategies (Final Scientific/Technical Report)

This research project, entitled Wellbore Leakage Mitigation using Advanced Mineral Precipitation Strategies, was directed toward advancing mineral precipitation technologies to seal wellbore leaks and other potential carbon dioxide (CO 2 ) leakage pathways, including compromised wellbore cement and fracture networks of varying geometries throughout the wellbore and surrounding formation. The advanced mineral sealing techniques were evaluated in the laboratory and the field to expand the range of temperature, pressure, and chemical conditions where mineral precipitation could be used. Rates of enzymatically or thermally induced calcium carbonate precipitation (EICP, TICP) were determined as well as rates of enzyme inactivation at elevated temperatures (>60 °C). Immobilization was shown to enhance the thermal stability of urease enzyme and provide protection from inhibition in low pH conditions. Mineral seals promoted by EICP and TICP were used to seal fractured composite (cement/sandstone) and shale cores in high pressure reactors operated at temperatures greater than 55 °C and 130 °C, respectively. A computational model was updated to model processes of EICP and TICP. The work resulted in a successful field test, which showed that EICP in the presence of low pH fluids (CO 2 -impacted brine) could promote permeability reduction and seal a channel in the near-wellbore environment.

54 ENVIRONMENTAL SCIENCES↗

Flash Neutron Imaging [Poster]

The NNSS has extensive historical experience with high-fidelity flash neutron imaging which may be applicable to the needs of NA-22. In recent neutron imaging tests, a dense plasma focus (DPF) discharges a capacitor bank across a hydrogen-filled diode to create a flash of fusion neutrons emitted from a point, which can be used for active interrogation. Object inspection may include both radiography transmission imaging as well as emission imaging of the subject via an aperture. A scintillator screen (coupled to a low-Z converter when necessary) converts deposited energy to visible light, which is relayed through optics to an ultra-sensitive visible imager contained in a light-tight box. Flash photon imaging, utilizing bremsstrahlung emission instead of fusion neutrons, is also available and is more mature.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring. We have deployed strainmeters and then conducted injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters (30 to 40m depth) was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 n/d over a few days. The signal at two strainmeters at shallow depth were consistent, although the magnitude of the horizontal strains were different reflecting the different radial directions from the well. The signal at a deep strainmeter deployed at reservoir depth was much different, with tensile vertical strains and compressive horizontal strains. These data can be interpreted by inverting poroelastic forward models developed using numerical and analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. This model is fast and can be inverted to estimate reservoir stiffness and geometry. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. The proxy model is periodically updated and refined using the finite element model to ensure accuracy. This approach significantly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. We have shown that the strain tensor in the caprock is sensitive to pressure in the reservoir, boundaries in the reservoir, and pressure in the caprock caused by leaks. These results indicate that coupling strain tensor data with inversion has the potential to help evaluate reservoirs during initial characterization, and to monitor them during the CO2 injection and storage process.

Murdoch, Larry↗

Auger spectroscopy beyond the ultra-short core-hole relaxation time approximation

Abstract We present a time-dependent computational approach to study Auger electron spectroscopy (AES) beyond the ultra-short core-hole relaxation time approximation and, as a test case, we apply it to the paradigmatic example of a one-dimensional Mott insulator represented by a half-filled Hubbard chain. The Auger spectrum is usually calculated by assuming that, after the creation of a core-hole, the system thermalizes almost instantaneously. This leads to a relatively simple analytical expression that uses the ground-state with a core-hole as a reference state and ignores all the transient dynamics related to the screening of the core-hole. In this picture, the response of the system can be associated to the pair spectral function. On the other hand, in our numerical calculations, the core hole is created by a light pulse, allowing one to study the transient dynamics of the system in terms of the pulse duration and in the non-perturbative regime. Time-dependent density matrix renormalization group calculations reveal that the relaxation process involves the creation of a polarization cloud of doublon excitations that have an effect similar to photo-doping. As a consequence, there is a leak of spectral weight to higher energies into what otherwise would be the Mott gap. For longer pulses, these excited states, mostly comprised of doublons, can dominate the spectrum. By changing the duration of the light-pulse, the entire screening process can be resolved in time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗