Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “krypton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Transmission Electron Microscopy Investigation of Krypton Bubbles in Polycrystalline CeO2

To gain an understanding of gas bubble transport in oxide nuclear fuel, this paper uses polycrystalline CeO 2 , composed of both nanograins and micrograins, as a surrogate material for UO 2 . The CeO 2 was implanted with 150-keV Kr ions up to a dose of 1 × 10 16 ions/cm 2 at 600°C. Transmission electron microscopy characterizations of small Kr bubbles in nanograin and micrograin regions were compared. The grain boundary acted as an efficient defect sink, as evidenced by smaller bubbles and a lower bubble density in the nanograin region as compared to the micrograin region.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vacancy effects on the formation of helium and krypton cavities in 3-C-SiC irradiated and annealed at elevated temperatures

Polycrystalline 3C-SiC was sequentially irradiated at 400 and 750°C with 120 keV He 2+ and 4 MeV Kr 15+ ions to 10 17 and 41016 cm -2 , respectively. The Kr 15+ ions penetrated the entire depth of the He 2+ ion implantation region. Three areas of He 2+ , Kr 15+ and He 2+ + Kr 15+ ion implanted 3C-SiC were created through masked overlapping irradiations. The sample was subsequently annealed at 1600°C in vacuum and characterized using cross-sectional transmission electron microscopy and energy-dispersive x-ray spectroscopy. Compared to the He 2+ ion only implanted 3C-SiC, helium cavities in the He 2+ and Kr15+ co-implanted 3C-SiC had a smaller size but higher density. At 25 dpa, presence of He in the co-implanted 3C-SiC significantly promoted cavity growth; much smaller voids were formed in the Kr 15+ ion only irradiated 3C-SiC at the same dose. In addition, local Kr migration and trapping at cavities occurred, but long-range Kr diffusion in 3C-SiC was not observed up to 1600°C.

36 MATERIALS SCIENCE↗

Crystals for krypton helium-alpha line emission microscopy

A system for reflecting and recording x-ray radiation from an x-ray emitting event to characterize the event. A crystal is aligned to receive radiation along a first path from an x-ray emitting event. Upon striking the crystal, the x-ray reflects from the crystal along a second path due to a reflection plane of the crystal defined by one of the following Miller indices: (9,7,3) or (11,3,3). Exemplary crystalline material is germanium. The x-rays are reflected to a detector aligned to receive reflected x-rays that are reflected from the crystal along the second path and the detector generates a detector signal in response to x-rays impacting the detector. The detector may include a CCD electronic detector, film plates, or any other detector type. A processor receives and processes the detector signal to generate reflection data representing the x-rays emitted from the x-ray emitting event.

47 OTHER INSTRUMENTATION↗

Multi-Column Experimental Test Bed for Xe/Kr Separation

Previous research studies have shown that INL-developed engineered form sorbents are capable of capturing both Kr and Xe from various composite gas streams. The previous experimental test bed provided single column testing for capacity evaluations over a broad temperature range. To advance research capabilities, the employment of an additional column to study selective capture of target species to provide a defined final gas composition for waste storage was warranted. The second column addition also allows for compositional analyses of the final gas product to provide for final storage determinations. The INL krypton capture system was modified by adding an additional adsorption column in order to create a multi-column test bed. The purpose of this modification was to investigate the separation of xenon from krypton supplied as a mixed gas feed. The extra column was placed in a Stirling Ultra-low Temperature Cooler, capable of controlling temperatures between 190 and 253K. Additional piping and valves were incorporated into the system to allow for a variety of flow path configurations. The new column was filled with the AgZ-PAN sorbent which was utilized as the capture medium for xenon while allowing the krypton to pass through. The xenon-free gas stream was then routed to the cryostat filled with the HZ-PAN sorbent to capture the krypton at 191K. Selectivities of xenon over krypton were determined using the new column to verify the system performance and to establish the operating conditions required for multi-column testing. Results of these evaluations verified that the system was operating as designed and also demonstrated that AgZ-PAN exhibits excellent selectivity for xenon over krypton in air at or near room temperature. Two separation tests were performed utilizing a feed gas consisting of 1000 ppmv xenon and 150 ppmv krypton with the balance being made up of air. The AgZ-PAN temperature was held at 295 or 253K while the HZ-PAN was held at 191K for both tests. The effluent from the AgZ-PAN column was monitored via GC-TCD during the tests with no xenon being observed exiting the column during either test. Samples from each column were taken via evacuated sample bombs and were analyzed by GC-MS analysis. The results demonstrated the ability to separate xenon from krypton from a mixed gas feed utilizing the new multi-column system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-Column Xe/Kr Separation with AgZ-PAN and HZ-PAN

Previous multi-column xenon/krypton separation tests have demonstrated the capability of separating xenon from krypton in a mixed gas feed stream. The results of this initial testing with AgZ-PAN and HZ-PAN indicated that an excellent separation of xenon from krypton could be achieved. Building upon these initial results, a series of additional multi-column testing were performed in FY-16. The purpose of this testing was to scale up the sorbent beds, test a different composition of feed gas and attempt to improve the accuracy of the analysis of the individual capture columns’ compositions. Two Stirling coolers were installed in series to perform this testing. The use of the coolers instead of the cryostat provided two desired improvements, 1) removal of the large dilution due to the internal volume of the cryostat adsorption chamber, and 2) ability to increase the sorbent bed size for scale-up. The AgZ-PAN sorbent, due to its xenon selectivity, was loaded in the first column to capture the xenon while allowing the krypton to flow through and be routed to a second column containing the HZ-PAN for capture and analysis. The gases captured on both columns were sampled with evacuated sample bombs and subsequently analyzed via GC-MS for both krypton and xenon. The results of these tests can be used to develop the scope of future testing and analysis using this test bed for demonstrating the capture and separation of xenon and krypton using sorbents, for demonstrating desorption and regeneration of the sorbents, and for determining compositions of the desorbed gases. They indicate a need for future desorption studies in order to better quantify co-adsorbed species and final krypton purity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capacity of ETS-10 supported carbon nanosorbent for removal of multicomponent from off-gas stream

Nuclear fission results in fission and activation products, some of which are volatile under the conditions of used nuclear fuel (UNF) reprocessing. Several volatile radionuclides are released into the atmosphere through offgas stream, which includes {sup 3}H, {sup 14}C, {sup 129}I and noble gases, Kr and Xe. {sup 129}I is a highly mobile and volatile contaminant. It has half-life period about 1.57 x 107 years that tends to bioaccumulate, concentrating in the thyroid glands and affecting bio-metabolism in humans. {sup 85}Kr is a chemically inert radioisotope with a half-life of 10.7 years that continuously accumulate in the environment. Control of emissions of these contaminants is necessary to comply with the stringent regulatory limits placed on their releases to protect human health and environment. Removal of these contaminants has been a challenge since the 1950's, and several methods including cryogenic distillation, fluorocarbon absorption, wet scrubbing, and adsorption have been employed. Currently, adsorption on porous solid sorbent shows the most promise results. Up to now, several sorbents such as silver impregnated mordenite, silver ETS-10, chalcogen based aerogels, and metal organic framework, MOFs have been developed for this purpose. Despite these advances, development of economical and highly active sorbents for complete removal and immobilization of volatile radioactive gases remains a key challenge in realizing advanced fuel cycles. Present research work is focused on the determination of the removal capacity of C'at'ETS-10 sorbent for a multicomponent (iodine and krypton) off-gas stream at ambient temperature. Our previously reported work showed that the 10 wt% C'at'ETS-10 sorbent was active for adsorption of krypton as well as iodine at ambient temperature and pressure. Therefore, 10 wt% C'at'ETS-10 sorbent was synthesized by wet-impregnation technique. The performance evaluation of the prepared nanosorbent was examined for the removal of iodine and krypton from the breakthrough curves obtained using bench scale experimental setup. ETS-10 supported carbon nanoparticles, C'at'ETS-10 nanosorbent was successfully synthesized by wet-impregnation technique. The 1/8 inch pelletized sorbent was used to minimize the pressure drop in adsorption column. The capacity of sorbent was found to be 0.143 mg g{sup -1} for krypton and 24.5 mg g{sup -1} for iodine. This experimental results indicates the C'at'ETS-10 is the effect sorbent for removal of multicomponent, krypton as well as iodine from the off-gas stream at ambient temperature. (authors)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

IMPACT REGIMES AND POST-FORMATION SEQUESTRATION PROCESSES: IMPLICATIONS FOR THE ORIGIN OF HEAVY NOBLE GASES IN TERRESTRIAL PLANETS

The difference between the measured atmospheric abundances of neon, argon, krypton, and xenon for Venus, Earth, and Mars is striking. Because these abundances drop by at least 2 orders of magnitude as one moves outward from Venus to Mars, the study of the origin of this discrepancy is a key issue that must be explained if we are to fully understand the different delivery mechanisms of the volatiles accreted by the terrestrial planets. In this work, we aim to investigate whether it is possible to quantitatively explain the variation of the heavy noble gas abundances measured on Venus, Earth, and Mars, assuming that cometary bombardment was the main delivery mechanism of these noble gases to the terrestrial planets. To do so, we use recent dynamical simulations that allow the study of the impact fluxes of comets upon the terrestrial planets during the course of their formation and evolution. Assuming that the mass of noble gases delivered by comets is proportional to the rate at which they collide with the terrestrial planets, we show that the krypton and xenon abundances in Venus and Earth can be explained in a manner consistent with the hypothesis of cometary bombardment. In order to explain the krypton and xenon abundance differences between Earth and Mars, we need to invoke the presence of large amounts of CO{sub 2}-dominated clathrates in the Martian soil that would have efficiently sequestered these noble gases. Two different scenarios based on our model can also be used to explain the differences between the neon and argon abundances of the terrestrial planets. In the first scenario, cometary bombardment of these planets would have occurred at epochs contemporary with the existence of their primary atmospheres. Comets would have been the carriers of argon, krypton, and xenon, while neon would have been gravitationally captured by the terrestrial planets. In the second scenario, we consider impacting comets that contained significantly smaller amounts of argon, an idea supported by predictions of noble gas abundances in these bodies, provided that they formed from clathrates in the solar nebula. In this scenario, neon and argon would have been supplied to the terrestrial planets via the gravitational capture of their primary atmospheres whereas the bulk of their krypton and xenon would have been delivered by comets.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-component testing using HZ-PAN and AgZ-PAN Sorbents for OSPREY Model validation

In efforts to further develop the capability of the Off-gas SeParation and RecoverY (OSPREY) model, multi-component tests were completed using both HZ-PAN and AgZ-PAN sorbents. The primary purpose of this effort was to obtain multi-component xenon and krypton capacities for comparison to future OSPREY predicted multi-component capacities using previously acquired Langmuir equilibrium parameters determined from single component isotherms. Experimental capacities were determined for each sorbent using two feed gas compositions of 1000 ppmv xenon and 150 ppmv krypton in either a helium or air balance. Test temperatures were consistently held at 220 K and the gas flowrate was 50 sccm. Capacities were calculated from breakthrough curves using TableCurve® 2D software by Jandel Scientific. The HZ-PAN sorbent was tested in the custom designed cryostat while the AgZ-PAN was tested in a newly installed cooling apparatus. Previous modeling validation efforts indicated the OSPREY model can be used to effectively predict single component xenon and krypton capacities for both engineered form sorbents. Results indicated good agreement with the experimental and predicted capacity values for both krypton and xenon on the sorbents. Overall, the model predicted slightly elevated capacities for both gases which can be partially attributed to the estimation of the parameters and the uncertainty associated with the experimental measurements. Currently, OSPREY is configured such that one species adsorbs and one does not (i.e. krypton in helium). Modification of OSPREY code is currently being performed to incorporate multiple adsorbing species and non-ideal interactions of gas phase species with the sorbent and adsorbed phases. Once these modifications are complete, the sorbent capacities determined in the present work will be used to validate OSPREY multicomponent adsorption predictions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗