Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kWh”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Separators - Technology review: Ceramic based separators for secondary batteries

Besides a continuous increase of the worldwide use of electricity, the electric energy storage technology market is a growing sector. At the latest since the German energy transition ('Energiewende') was announced, technological solutions for the storage of renewable energy have been intensively studied. Storage technologies in various forms are commercially available. A widespread technology is the electrochemical cell. Here the cost per kWh, e. g. determined by energy density, production process and cycle life, is of main interest. Commonly, an electrochemical cell consists of an anode and a cathode that are separated by an ion permeable or ion conductive membrane - the separator - as one of the main components. Many applications use polymeric separators whose pores are filled with liquid electrolyte, providing high power densities. However, problems arise from different failure mechanisms during cell operation, which can affect the integrity and functionality of these separators. In the case of excessive heating or mechanical damage, the polymeric separators become an incalculable security risk. Furthermore, the growth of metallic dendrites between the electrodes leads to unwanted short circuits. In order to minimize these risks, temperature stable and non-flammable ceramic particles can be added, forming so-called composite separators. Full ceramic separators, in turn, are currently commercially used only for high-temperature operation systems, due to their comparably low ion conductivity at room temperature. However, as security and lifetime demands increase, these materials turn into focus also for future room temperature applications. Hence, growing research effort is being spent on the improvement of the ion conductivity of these ceramic solid electrolyte materials, acting as separator and electrolyte at the same time. Starting with a short overview of available separator technologies and the separator market, this review focuses on ceramic-based separators. Two prominent examples, the lithium-ion and sodium-sulfur battery, are described to show the current stage of development. New routes are presented as promising technologies for safe and long-life electrochemical storage cells.

25 ENERGY STORAGE↗

Vulnerability of Karangkates dams area by means of zero crossing analysis of data magnetic

Study with entitled Vulnerability Karangkates Dam Area By Means of Zero Crossing Analysis of Data Magnetic has been done. The study was aimed to obtain information on the vulnerability of two parts area of Karangkates dams, i.e. Lahor dam which was inaugurated in 1977 and Sutami dam inaugurated in 1981. Three important things reasons for this study are: 1). The dam age was 36 years old for Lahor dam and 32 years old for Sutami dam, 2). Geologically, the location of the dams are closed together to the Pohgajih local shear fault, Selorejo local fault, and Selorejo limestone-andesite rocks contact plane, and 3). Karangkates dams is one of the important Hydro Power Plant PLTA with the generating power of about 400 million KWH per year from a total of about 29.373MW installed in Indonesia. Geographically, the magnetic data acquisition was conducted at coordinates (112.4149oE;-8.2028oS) to (112.4839oE;-8.0989oS) by using Proton Precession Magnetometer G-856. Magnetic Data acquisition was conducted in the radial direction from the dams with diameter of about 10 km and the distance between the measurements about 500m. The magnetic data acquisition obtained the distribution of total magnetic field value in the range of 45800 nT to 44450 nT. Residual anomalies obtained by doing some corrections, including diurnal correction, International Geomagnetic Reference Field (IGRF) correction, and reductions so carried out the distribution of the total magnetic field value in the range of -650 nT to 700 nT. Based on the residual anomalies, indicate the presence of 2 zones of closed closures dipole pairs at located in the west of the Sutami dam and the northwest of the Lahor dam from 5 total zones. Overlapping on the local geological map indicated the lineament of zero crossing patterns in the contour of residual anomaly contour with the Pohgajih shear fault where located at about 4 km to the west of the Sutami dam approximately and andesite-limestone rocks contact where located at about 6 km to the west of the Lahor dam approximately. These shown a possible of vulnerability on geohazards at the west zone of the Karangkates (Lahor-Sutami) dams area if there are triggers by the vibration (earthquake) on the Pohgajih shear fault, andesite-limestone contact plane, and instability rocks on two zones of closed closure dipole pairs area. Reality, on the location of the study shown some local landslide at the several locations and the main road that need considering for disaster mitigation.

58 GEOSCIENCES↗

Synchrotron-based investigation of transition-metal getterability in n-type multicrystalline silicon

Solar cells based on n-type multicrystalline silicon (mc-Si) wafers are a promising path to reduce the cost per kWh of photovoltaics; however, the full potential of the material and how to optimally process it are still unknown. Process optimization requires knowledge of the response of the metal-silicide precipitate distribution to processing, which has yet to be directly measured and quantified. To supply this missing piece, we use synchrotron-based micro-X-ray fluorescence (μ-XRF) to quantitatively map >250 metal-rich particles in n-type mc-Si wafers before and after phosphorus diffusion gettering (PDG). We find that 820°C PDG is sufficient to remove precipitates of fast-diffusing impurities and that 920°C PDG can eliminate precipitated Fe to below the detection limit of μ-XRF. Thus, the evolution of precipitated metal impurities during PDG is observed to be similar for n- and p-type mc-Si, an observation consistent with calculations of the driving forces for precipitate dissolution and segregation gettering. Measurements show that minority-carrier lifetime increases with increasing precipitate dissolution from 820°C to 880°C PDG, and that the lifetime after PDG at 920°C is between the lifetimes achieved after 820°C and 880°C PDG.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Power generation study of luminescent solar concentrator greenhouse

A Luminescent Solar Concentrator (LSC) greenhouse and an identical control greenhouse were constructed with photovoltaic (PV) cells attached to the roof panels of both structures. The placement and types of PV cells used in the LSC panels were varied for performance comparisons. Solar power generation was monitored continuously for one year, with leading LSC panels exhibiting a 37% increase in power production compared to the reference. The 22.3 m 2 greenhouse was projected to generate a total of 1342 kWh per year, or 57.4 kWh/m 2 if it were composed solely of the leading panel of Criss Cross panel design. The LSC panels also showed no signs of degradation throughout the trial demonstrating the material's robustness in field conditions.

14 SOLAR ENERGY↗

Energy considerations regarding pulsed arc production of nanomaterials

Atmospheric arc discharge volumes have been estimated from the light distribution emitted during evaporation of graphite and molybdenum disulphide (MoS 2 ) anodes. These data have been correlated to the peak power in the case of pulsed arc discharge held at different frequencies (1, 2 and 5 Hz). The measured power density values and the corresponding specific energies per particle have been compared to DC values, and showed that pulsed arc discharges deliver electrical power more efficiently than DC arc discharges do with yet lower thermal loads. In particular, the power density of ≈1 kW/cm 3 characteristic of pulsed arcs (10-20 kW/cm 3 in DC) suffices to provide 15 eV/particle to the arc plasma (≈10 eV/particle or less in DC). Such an energy balance resulted in high ionization rates of the ablated material and production yields of carbon nanotubes around 10 11 cm -2 kWh -1 . Lastly, in situ probe experiments showed that pulsed arcs enhance the transport to substrate of the generated nanoparticles, such as graphene and MoS 2 monolayers. Pulsed anodic arcs open the possibility to generate further nanomaterials thanks to a more rational power investment and a better control of the discharge region.

42 ENGINEERING↗

Least-cost targets and avoided fossil fuel capacity in India’s pursuit of renewable energy

India has set aggressive targets to install more than 400 GW of wind and solar electricity generation by 2030, with more than two-thirds of that capacity coming from solar. This paper examines the electricity and carbon mitigation costs to reliably operate India’s grid in 2030 for a variety of wind and solar targets (200 GW to 600 GW) and the most promising options for reducing these costs. We find that systems where solar photovoltaic comprises only 25 to 50% of the total renewable target have the lowest carbon mitigation costs in most scenarios. This result invites a reexamination of India’s proposed solar-majority targets. We also find that, compared to other regions and contrary to prevailing assumptions, meeting high renewable targets will avoid building very few new fossil fuel (coal and natural gas) power plants because of India’s specific weather patterns and need to meet peak electricity demand. However, building 600 GW of renewable capacity, with the majority being wind plants, reduces how often fossil fuel power plants run, and this amount of capacity can hold India’s 2030 emissions below 2018 levels for less than the social cost of carbon. With likely wind and solar cost declines and increases in coal energy costs, balanced or wind-majority high renewable energy systems (600 GW or ≈ 45% share by energy) could result in electricity costs similar to a fossil fuel-dominated system. As an alternative strategy for meeting peak electricity demand, battery storage can avert the need for new fossil fuel capacity but is cost effective only at low capital costs (≈ USD 150 per kWh).

14 SOLAR ENERGY↗

Corporate Delivery of a Global Smart Buildings Program

Buildings account for about 40 percent of the total energy consumption in the U.S. and emit approximately one third of greenhouse gas emissions. But they also offer tremendous potential for achieving significant greenhouse gas reductions with the right savings strategies. With an increasing amount of data from buildings and advanced computational and analytical abilities, buildings can be made “smart” to optimize energy consumption and occupant comfort. Smart buildings are often characterized as having a high degree of data and system integration, connectivity and control, as well as the advanced use of data analytics. These “smarts” can enable up to 10–20% savings in a building, and help ensure that they persist over time. In 2009, Microsoft Corporation launched the Energy-Smart Buildings (ESB) program with a vision to improve building operations services, security and accessibility in services, and new tenant applications and services that improve productivity and optimize energy use. The ESB program focused on fault diagnostics, advanced analytics and new organizational processes and practices to support their operational integration. In addition to the ESB program, Microsoft undertook capital improvement projects that made effective use of a utility incentive program and lab consolidations over the same duration. The ESB program began with a pilot at Microsoft's Puget Sound campus that identified significant savings of up to 6–10% in the 13 pilot buildings. The success of the pilot led to a global deployment of the program. Between 2009 and 2015, there was a 23.7% reduction in annual electricity consumption (kWh) at the Puget Sound campus with 18.5% of that resulting from the ESB and lab consolidations. This article provides the results of research conducted to assess the best-practice strategies that Microsoft implemented to achieve these savings, including the fault diagnostic routines that are the foundation of the ESB program and organizational change management practices. It also presents the process that was adopted to scale the ESB program globally. We conclude with recommendations for how these successes can be generalized and replicated by other corporate enterprises.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical and economic analysis of solvent-based lithium-ion electrode drying with water and NMP

Processing lithium-ion battery (LIB) electrode dispersions with water as the solvent during primary drying offers many advantages over N-methylpyrrolidone (NMP). An in-depth analysis of the comparative drying costs of LIB electrodes is discussed for both NMP- and water-based dispersion processing in terms of battery pack $/kWh. Electrode coating manufacturing and capital equipment cost savings are compared for water vs. conventional NMP organic solvent processing. A major finding of this work is that the total electrode manufacturing costs, whether water- or NMP-based, contribute about 8–9% of the total pack cost. However, it was found that up to a 2 × reduction in electrode processing (drying and solvent recovery) cost can be expected along with a $3–6 M savings in associated plant capital equipment (for a plant producing 100,000 10-kWh Plug-in Hybrid Electric Vehicle (PHEV) batteries) using water as the electrode solvent. This paper shows a different perspective in that the most important benefits of aqueous electrode processing actually revolve around capital equipment savings and environmental stewardship and not processing cost savings.

25 ENERGY STORAGE↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Life-cycle environmental impacts of single-junction and tandem perovskite PVs: a critical review and future perspectives

For new technologies, such as perovskite solar cells (PSC), life cycle analysis (LCA) offers a fundamental framework for examining potential environmental, energy and health impacts and mitigation options before large-scale commercialization and for guiding improvements in development and production that further reduce their environmental footprint. However, credible LCA studies require actual process-based material, energy and emissions data, which may not exist before the technologies are commercially produced. Thus, the perovskite LCA literature is based on linear extrapolations of laboratory data. In this paper we critically reviewed the PSC LCA literature, explain the reasoning for a wide divergence of results, and determined which data apply to scalable industrial production, materials and processes. Our investigation probed into the formulation of each layer of a PSC device, and its potential for industrial scale fabrication. We found that electricity use is the main contributor to reported LCA results, explaining the large difference, ranging from 7.78 kWh to 1,460 kWh/m –2 , among various studies. Subsequently, we identified and discuss methodological errors in some of these estimates. In terms of life-cycle toxicity most of the reviewed LCA studies do not attribute any major overall toxicity impact to the presence of lead in the PSC devices. We also reviewed and critiqued studies describing “worst-case” scenarios of accidental release of lead into the environment, and, in spite of statements in those studies, we found them to be inconclusive. Lastly, we discussed end-of-life (EoL) management options for resource recovery and for minimizing environmental impacts.

14 SOLAR ENERGY↗

Estimating the electric vehicle charging demand of multi-unit dwelling residents in the United States

Abstract Early battery electric vehicle (EV) adopters can access home chargers for reliable charging. As the EV market grows, residents of multi-unit dwellings (MUDs) may face barriers in owning EVs and charging them without garage or parking availability. To investigate the mechanisms that can bridge existing disparities in home charging and station deployment, we characterized the travel behavior of MUD residents and estimated their EV residential charging demand. This study classifies the travel patterns of MUD residents by fusing trip diary data from the National Household Travel Survey and housing features from the American Housing Survey. A hierarchical agglomerative clustering method was used to cluster apartment complex residents’ travel profiles, considering attributes such as dwell time, daily vehicle miles traveled (VMT), income, and their residences’ US census division. We propose a charging decision model to determine the charging station placement demand in MUDs and the charging energy volume expected to be consumed, assuming that MUD drivers universally operate EVs in urban communities. Numerical experiments were conducted to gain insight into the charging demand of MUD residents in the US. We found that charging availability is indispensable for households that set out to meet 80% state of charge by the end of the day. When maintaining a 20% comfortable state of charge the entire day, the higher the VMT are, the greater the share of charging demand and the greater the energy use in MUD chargers. The upper-income group requires a greater share of MUD charging and greater daily kWh charged because of more VMT.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

What goes on behind closed doors? How college dormitory residents change to save energy during a competition-based energy reduction intervention

Here, the aim of our study was to evaluate the impact of a competition-based intervention combining high resolution electricity feedback, incentives, information, and prompts on college dormitory residents’ energy consumption and participation in demand response (DR) events. We also investigated changes in individual-level pro-environmental behaviors and examined psycho-social correlates of behavior change. Residents of 39 suites in a freshman residence hall competed against one another to reduce energy consumption and win prizes as part of a 3-week competition. Feedback was provided in near real time at the suite-level via an interactive touch-screen kiosk. Participants also completed baseline and followup surveys. Findings have indicated that electricity use among all suites was approximately 6.4% lower during the competition period compared to baseline, a significant reduction. Additionally, participants reported engaging in various pro-environmental behaviors significantly more frequently during the competition relative to baseline. Changes in pro-environmental behavior were associated with changes in level of group identification and perceived social norms. In three weeks, dormitory residents saved 3, 158 kWh of electricity compared to baseline – the equivalent of more than 3, 470 pounds of carbon dioxide emissions. Our findings provide evidence that real-time feedback, combined with incentives, information, and prompts, can motivate on-campus residents to reduce energy consumption. We contribute to a limited body of evidence supporting the effectiveness of dorm energy competitions in motivating college students to save energy. In addition, we identified individual-level behavioral and psycho-social changes made during such an intervention. University residential life planners may also use the results of this research to inform student programming.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and modeling for hydrogen fuel cell conversion of parcel delivery trucks

With an emphasis on reducing fossil fuel consumption and emissions, major delivery service corporations have begun deploying and operating Class 6 zero emissions delivery vans. Battery electric delivery vans are currently available, but their range is a limitation and doesn’t offer flexibility in assigning vehicles to delivery routes. Fuel cell hybrid delivery vans offer a zero emissions solution with extended range and route planning flexibility. In a competitive market, a delivery van design that trades the fuel cell and battery size, performance, and cost is critical to the success and adoption of these zero emissions trucks. This paper outlines a systematic approach using real world operational data and duty cycles to properly size the fuel cell and battery for a zero emissions hybrid delivery van. The approach uses real world GPS data to define routes and duty cycles, along with vehicle powertrain models to assess performance capabilities. Furthermore, the study suggests that a 32 kW fuel cell power system paired with a 49 kWh battery energy storage system and 15 kg of hydrogen storage is a desired option to complete the most demanding parcel and delivery duty cycles.

08 HYDROGEN↗

Assessing the Impact of Renewable Energy Sources to Achieve Net Zero Emissions

The mass generation of green energy through the pathway of Renewable Energy Sources (RES), is one of the major decisive components contributing to the concept of decarbonization. The energy sector assessment reveals that out of per kWh energy produced, renewable energy emits between 9 and 1000 gCO2 equivalent on a life-cycle basis. Contemplating the literature and the latest reports released by world-wide energy department(s), this study presents a comprehensive concept of carbon footprint, its causes and effects including major impact on biodiversity and human life. The study discusses the substantial steps taken by developing countries like India in leveraging RES for the production of energy and its progressive impact on ecology. The discussion would be inclusive of major change and transformation which has brought significant drop of 16% in the greenhouse gas (GHG) emissions by installation of 104.9 GW of RES excluding Hydro. The appropriate steps taken forward therefore align with the Sustainable Development Goals (SDGs) of the United Nation (UN) in achieving net zero emission (NZE).

decarbonization↗

Second use of transportation batteries: Maximizing the value of batteries for transportation and grid services

Plug-in hybrid electric vehicles (PHEVs) and electric vehicles (EVs) are expected to gain significant market share over the next decade. The economic viability for such vehicles is contingent upon the availability of cost-effective batteries with high power and energy density. For initial commercial success, government subsidies will be highly instrumental in allowing PHEVs to gain a foothold. However, in the long-term, for electric vehicles to be commercially viable, the economics have to be self-sustaining. Towards the end of battery life in the vehicle, the energy capacity left in the battery is not sufficient to provide the designed range for the vehicle. Typically, the automotive manufacturers indicated the need for battery replacement when the remaining energy capacity reaches 70-80%. There is still sufficient power (kW) and energy capacity (kWh) left in the battery to support various grid ancillary services such as balancing, spinning reserve, load following services. As renewable energy penetration increases, the need for such balancing services is expected to increase. This work explores optimality for the replacement of transportation batteries to be subsequently used for grid services. This analysis maximizes the value of an electric vehicle battery to be used as a transportation battery (in its first life) and then as a resource for providing grid services (in its second life). The results are presented across a range of key parameters, such as depth of discharge (DOD), number of batteries used over the life of the vehicle, battery life in vehicle, battery state of health (SOH) at end of life in vehicle and ancillary services rate. The results provide valuable insights for the automotive industry into maximizing the utility and the value of the vehicle batteries in an effort to either reduce the selling price of EVs and PHEVs or maximize the profitability of the emerging electrification of transportation.

(DOD)↗

Analysis of Energy Savings and CO2 Emission Reduction Contribution for Industrial Facilities in USA

Abstract Energy audits can identify energy consumptions, energy costs of the facility and evolve to develop measures to maximize efficiency, optimize supply energy, and eliminate waste. This paper investigates the potential energy savings at 20 different industrial sectors with 152 assessments for various facilities in Wisconsin, USA. On average, eight energy recommendations were suggested and applied in each facility. This paper provides a detailed guideline for each industry in terms of eight different energy categories: heating, ventilation, and air conditioning (HVAC) systems, heat recovery systems, electrical demand management, and utility bills, motors, compressors, waste management, and productivity enhancement, lighting, besides building envelope. In total, the energy savings were as follows: 98 million kWh in the shape of electricity, 561 billion British thermal units (BTUs) gas savings, 44 million gallons water savings, and 2-million-pound solid waste savings. Based on these savings, a 100-thousand-ton reduction in carbon dioxide emissions was obtained.

Energy & Fuels↗

Energy Impact of Radiative Cooling Paints in Warehouses Under Various United States Climates

Although radiative cooling research is widely found in the literature, no comprehensive study has yet been conducted on the impact of novel radiant cooling (>0.91 reflectance) on the energy efficiency of warehouses. Here, in this work, we develop three building models based on a Department of Energy prototype warehouse model using trnsys, representing a typical warehouse with a black roof, a typical warehouse with a white roof, and a warehouse with novel radiative cooling (RC) paint on its roof. These models are run for 15 different cities, each representative of a different ASHRAE climate zone, to better understand the impact of RC in many different climates. It was found that an RC-coated roof in a warehouse could reduce the building's annual heating, ventilation, and air conditioning (HVAC) loads by up to 14.11 kWh/m 2 of the roof area compared to a black roof, resulting in a maximum reduction in energy costs of 0.55 $\$$/m 2 or $\$$2646/year for a large 4835 m 2 warehouse. Similarly, replacing the typical white roof coating with an RC coating could reduce the warehouse's energy consumption by up to 8.17 kWh/ m 2 of roof area, thus reducing energy costs by as much as 0.29 $\$$/m 2 or $\$$1386/year for a 4835 m 2 warehouse. In addition, applying RC paint to an unconditioned warehouse could reduce the building's ASHRAE Standard 55 indoor temperature exceedance by up to 1330 h/year compared to a black roof and up to 532 h/year compared to a white roof.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rare earth elements from waste

Rare earth elements (REEs) are critical materials in electronics and clean technologies. With the diminishing of easily accessible minerals for mining, the REE recovery from waste is an alternative toward a circular economy. Present methods for REE recovery suffer from lengthy purifications, low extractability, and high wastewater streams. Here, we report an ultrafast electrothermal process (~3000°C, ~1 s) based on flash Joule heating (FJH) for activating wastes to improve REE extractability. FJH thermally degrades or reduces the hard-to-dissolve REE species to components with high thermodynamic solubility, leading to ~2× increase in leachability and high recovery yields using diluted acid (e.g., 0.1 M HCl). The activation strategy is feasible for various wastes including coal fly ash, bauxite residue, and electronic waste. The rapid FJH process is energy-efficient with a low electrical energy consumption of 600 kWh ton –1 . The potential for this route to be rapidly scaled is outlined.

01 COAL, LIGNITE, AND PEAT↗