Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The application of hydraulics in the 2,000 kW wind turbine generator

A 2000 kW turbine generator using hydraulic power in two of its control systems is being built under the management of NASA Lewis Research Center. The hydraulic systems providing the control torques and forces for the yaw and blade pitch control systems are discussed. The yaw-drive-system hydraulic supply provides the power for positioning the nacelle so that the rotary axis is kept in line with the direction of the prevailing wind, as well as pressure to the yaw and high speed shaft brakes. The pitch-change-mechanism hydraulic system provides the actuation to the pitch change mechanism and permits feathering of the blades during an emergency situation. It operates in conjunction with the overall windmill computer system, with the feather control permitting slewing control flow to pass from the servo valve to the actuators without restriction.

Onufreiczuk, S.↗

Description of A 2.3 kW power transformer for space applications

The paper describes the principal features and special testing of a high-frequency high-power low-specific-weight (0.57 kg/kW) 2.3-kW electronic power transformer developed for space applications. The transformer is operated in a series resonant inverter supplying beam power to a 30-cm mercury ion thruster. High efficiency (above 98.5%) is obtained through careful detailed design. A number of unique heat removal techniques are discussed which control the winding temperature using only the available conductive cooling.

Hansen, I.↗

Utility operational experience on the NASA/DOE Mod-OA 200 kW Wind Turbine

The Mod-OA 200 kW Wind Turbine was designed and fabricated by the Lewis Research Center of the NASA under the direction of the U.S. Department of Energy. The project is a part of the Federal Wind Energy Program and is designed to obtain early wind turbine operation and performance data while gaining initial experience in the operation of large, horizontal axis wind turbines in typical utility environments. On March 6, 1978, the Mod-OA wind turbine was turned over to the Town of Clayton Light and Water Plant, Clayton, NM, for utility operation and on December 31, 1978 the machine had completed ten months of utility operation. This paper describes the machine and documents the recent operational experience at Clayton, NM.

Glasgow, J. C.↗

Performance of 22.4-kW nonlaminated-frame dc series motor with chopper controller

Performance data obtained through experimental testing of a 22.4 kW traction motor using two types of excitation are presented. Ripple free dc from a motor-generator set for baseline data and pulse width modulated dc as supplied by a battery pack and chopper controller were used for excitation. For the same average values of input voltage and current, the motor power output was independent of the type of excitation. However, at the same speeds, the motor efficiency at low power output (corresponding to low duty cycle of the controller) was 5 to 10 percentage points lower on chopped dc than on ripple free dc. The chopped dc locked-rotor torque was approximately 1 to 3 percent greater than the ripple free dc torque for the same average current.

Schwab, J. R.↗

Teetered, tip-controlled rotor: Preliminary test results from Mod-0 100-kW experimental wind turbine

Results of tests conducted using the MOD-0 100 kW experimental wind turbine are evaluated. The teetered rotor significantly decreased loads on the yaw drive mechanism and reduced blade cyclic flapwise bending moments by 25 percent at the 20 percent span location when compared to the rigid hub rotor. The teetered hub performed well, but impacted the teeter stops on occasion as wind speed and/or direction varied rapidly. The tip-controlled rotor performed satisfactorily with some expected loss of control when compared to the full span pitchable blade. The performance results indicate that a review of techniques used to calculate rotor power is in order.

Glasgow, J. C.↗

Study of multi-kW solar arrays for Earth orbit application

Low cost low Earth orbit (LOW) and geosynchronous Earth orbit (GEO) Solar Array concepts in the 300 to 1000 kW range which could be reduced to hardware in the mid 1980's, are identified. Size scaling factors and longer life demands are recognized as the prime drivers for the designs if low life cycle costs for energy are to be achieved. Technology is identified which requires further development in order to assure component readiness and availability. Use of the low concentration ratio (CR) concentrator, which uses gallium arsenide solar cells for both LEO and GEO applications, is recommended.

Source record↗

IEA/SPS 500 kW distributed collector system

Engineering studies for an International Energy Agency project for the design and construction of a 500 kW solar thermal electric power generation system of the distributed collector system (DCS) type are reviewed. The DCS system design consists of a mixed field of parabolic trough type solar collectors which are used to heat a thermal heat transfer oil. Heated oil is delivered to a thermocline storage tank from which heat is extracted and delivered to a boiler by a second heat transfer loop using the same heat transfer oil. Steam is generated in the boiler, expanded through a steam turbine, and recirculated through a condenser system cooled by a wet cooling tower.

Neumann, T. W.↗

Teetered, tip-controlled rotor - Preliminary test results from Mod-O 100-kW experimental wind turbine

A series of tests is currently being conducted using the DOE/NASA 100 kW Experimental Wind Turbine with a two-bladed, teetered rotor with 30% span tip control. Preliminary evaluation test results indicates that the teetered rotor significantly decreases loads on the yaw drive mechanism and reduces blade cyclic flapwise bending moments by 25% at the 20% span location when compared to rigid hub rotor. The teetered hub performed well but did impact the teeter stops on occasion as wind speed and/or direction varied rapidly. The tip-controlled rotor performed satisfactorily with some expected loss of control when compared to the full span pitchable blade. The performance results indicate that a review of techniques used to calculate rotor power is in order.

Glasgow, J. C.↗

An exploratory survey of noise levels associated with a 100 kW wind turbine

During performance tests of a 125-foot diameter, 100 kW wind turbine at the NASA Plum Brook Station near Sandusky, Ohio, the opportunity arose to make exploratory noise measurements and results of those surveys are presented. The data include measurements as functions of distance from the turbine, and directivity angle, and cover a frequency range from 1 Hz to several kHz. Potential community impact is discussed in terms of A-weighted noise levels relative to background levels, and the infrasonic spectral content. Finally, the change in the sound power spectrum associated with a change in the rotor speed is described. The acoustic impact of this size wind turbine is judged to be minimal.

Balombin, J. R.↗

NASA's 25 kW Power Module - Reference System

The paper deals with a 25-kW orbit-based power system which will be used to expand the Shuttle/Spacelab mission durations in a sortie mode and as an orbit-based platform for spacecraft in a free-flying mode. Consideration is given to operations, system description, capabilities and resources, and growth potential.

Powell, L. E.↗

Multi-hundred kW solar arrays for space

A system-level approach has been applied in designing a cost-effective 300-1000 kW solar array for Low Earth Orbit (LEO) application with a mission time frame of mid-1980's. Technology investigations and performance and cost prognoses in the area of solar cells and reflector material form a key influence on array design and performance. Major tradeoffs were conducted between planar and concentrator concepts and between silicon and GaAs solar cells. Three baseline design concepts emerged: planar, low-CR concentrator (CR = 5), and high-CR concentrator (CR = 125). Combinations of these concepts with silicon and GaAs solar cells were analyzed in terms of electrical performance, thermal behavior, structural configuration, weight, stowed and deployed volume, and installation/deployment method. To identify the most cost-effective designs, a cost analysis of the candidate arrays was performed. The low-CR/GaAs array and the planar/silicon array demonstrate the greatest cost-effectiveness of the candidate arrays in terms of dollars/watt and energy life-cycle cost. Due to the high uncertainty of GaAs cell-cost prognoses, the sensitivity of the results to the GaAs cell cost is discussed.

Woodcock, W. G., III↗

A 20-kW X-band uplink transmitter development

The 20 kW X-band transmitter power amplifier and its related control and monitor cabinet are described. The circuitry for the monitoring and protection of various transmitter components is discussed.

Kolbly, R. B.↗

MOD-0A 200 kW wind turbine generator design and analysis report

The design, analysis, and initial performance of the MOD-OA 200 kW wind turbine generator at Clayton, NM is documented. The MOD-OA was designed and built to obtain operation and performance data and experience in utility environments. The project requirements, approach, system description, design requirements, design, analysis, system tests, installation, safety considerations, failure modes and effects analysis, data acquisition, and initial performance for the wind turbine are discussed. The design and analysis of the rotor, drive train, nacelle equipment, yaw drive mechanism and brake, tower, foundation, electricl system, and control systems are presented. The rotor includes the blades, hub, and pitch change mechanism. The drive train includes the low speed shaft, speed increaser, high speed shaft, and rotor brake. The electrical system includes the generator, switchgear, transformer, and utility connection. The control systems are the blade pitch, yaw, and generator control, and the safety system. Manual, automatic, and remote control are discussed. Systems analyses on dynamic loads and fatigue are presented.

Anderson, T. S.↗

Software control program for 25 kW breadboard testing

A data acquisition software program developed to operate in conjunction with the automated control system of the 25 kW PM Electric Power System Breadboard Test facility is described. The proram provides limited interactive control of the breadboard test while acquiring data and monitoring parameters, allowing unattended continuous operation. The breadboard test facility has two positions for operating separate configurations. The main variable in each test setup is the high voltage Ni-Cd battery.

Pajak, J. A.↗

The 40-kw field test power plant modification and development, phase 2

Progression on the design and development of a 40 KW fuel cell system for on-site installation for providing both thermal and electrical power is reported. Development of the steam reformer fuel processor, power section, inverter, control system, and thermal management and water treatment systems is described.

Source record↗

Iodine monofluoride 140-kW laser - Small signal gain and operating parameters

Output energies in excess of 4 mJ in a 30-nsec FWHM pulse (140-kW peak power) have been obtained from a discharge-pumped IF laser for a cavity output coupling of 35%. In addition, oscillation on a new transition of the IF (E-A) band at 472.7 nm has been observed. By measurement of the output power of the laser for various values of output mirror transmission, the small signal gain and loss coefficients were found to be (3.1 + or - 0.7)%/cm and 0.3%/cm, respectively.

Dlabal, M. L.↗

Performance testing of a 50 kW VAWT in a built-up environment

The results of performance tests of a DAF Indal 50 kW vertical axis wind turbine are presented. Results of limited free stream turbulence and vertical wind shear measurements at the site are also presented. The close agreement between measured and predicted energy outputs, required to verify the wind turbine power output performance relationship, was not attained. A discussion is presented of factors that may have contributed to the lack of better agreement.

Schienbein, L. A.↗

Multi-100 kW: Planar low cost solar array development

The development of a 100 kW planar low cost solar array is presented. Tasks are defined, objectives are stated, and test results are given. A study of alternate contact configuration concluded that gridded back contact cells sharply reduced solar absorptance, that copper contacts will require a developmental program before interface can be achieved, and that gridded back contact cells using Ti-Pd-Ag as the contact materials appear to be the most cost-effective design.

Source record↗