Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isolation cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Trace element partitioning between taenite and kamacite - Relationship to the cooling rates of iron meteorites

Instrumental neutron activation analysis (INAA) was used to determine Ni, Co, Cu, Ga, As, Au, W, Re and Ir in taenite lamellae isolated by acid dissolution from eight iron meteorites from groups IA, IIIAB and IVA. Taenite is enriched in Ni, Cu, Ga, As, Au, W, Re and Ir relative to kamacite, whereas taenite is depleted in Co. Taenite/kamacite partition ratios in slowly cooled IAB meteorites are farther from unity than those in rapidly cooled IVA meteorites. Taenite/kamacite partition ratios for Cu, Ir, Au and Co may be sensitive cooling rate indicators.

Rasmussen, Kaare L.↗

South Africa National Cooling Plan

South Africa is committed to preserving the environment and addressing climate change related issues based on science and equity. In 2019, South Africa ratified the Kigali Amendment to the Montreal Protocol to reduce the consumption and production of hydrofluorocarbons (HFCs) to simultaneously protect the ozone layer and contribute to mitigating climate change. In 2015, South Africa also signed the United Nations Framework Convention on Climate Change (UNFCCC) Paris Agreement to fight against climate change and committed to achieve a “peak, plateau and decline” greenhouse gas (GHG) trajectory at a level between 398 and 614 MtCO2e/year by 20301. In 2021 revised target ranges of 398-510 Mt CO 2 -eq for 2025, and 398-440 Mt CO 2 -eq for 2030 were issued, as well as aspiring to reach a net zero carbon economy by 2050. Addressing the environmental impacts of cooling products converges the objectives of these two treaties. Cooling products are the main source of HFC use and they consume a significant amount of electricity produced from emission intensive coal fired power plants. South Africa’s efforts to mitigate global warming can therefore be amplified if the energy efficiency (EE) of cooling products is improved at the same time a refrigerant transition from HFC is considered. Synergistic actions with respect to sustainable cooling access across sectors will have a higher impact than actions taken in isolation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Search for the Identification of 3EG J1835+5918: Evidence for a New Type of High-Energy Gamma-Ray Source?

Most of the EGRET high-energy gamma-ray sources remain unidentified. It is highly likely that many of these are fainter blazars or pulsars, but there may also be new types of sources to be discovered. We have focussed our search for novel gamma-ray sources on 3EG 1835+5918, which is the brightest and most accurately positioned of the unidentified EGRET sources at high Galactic latitude (l, b = 89 deg, 25 deg). In this talk, we will summarize the results of X-ray, radio, and optical surveys of this location. In particular, we have made complete optical identifications of all of the ROSAT and ASCA sources in this region to a flux limit of approximately 1 x 10(exp -13) ergs/sq cm s. All of the X-ray sources within the EGRET error circle are radio-quiet quasars or coronally emitting stars. Previous radio pulsar searches have been unsuccessful. We set an upper limit of 3.8 mJy (at 1.4 GHz) on any possible radio counterpart to 3EG 1835+5918. We also find several quasars and white dwarfs using optical color selection, and we have monitored the entire field for variable optical objects on short and long time scales. Since no blazar-like or pulsar-like candidate has been found as a result of these searches, we assert that 3EG 1835+5918 must be lacking in one or more of the physically essential attributes of those classes of gamma-ray emitters. In particular, its radio flux is at least two orders of magnitude fainter than any of the securely identified EGRET blazars, and its soft X-ray flux is at least 30 times fainter than that of Geminga and other EGRET pulsars. If it is an AGN it lacks the beamed radio emission of blazars. If it is an isolated neutron star, it lacks both the thermal X-rays from a cooling surface and the magnetospheric non-thermal X-ray emission that is characteristic of all EGRET pulsars. As such, it is more problematic physically than Geminga, which is an ordinary pulsar that only lacks radio emission. As a pulsar, 3EG 1835+5918 would have to be either older or more distant than Geminga, and probably an even more efficient gamma-ray engine.

Mirabal, N.↗

Search for the Identification of 3EG J1835+5918: Evidence for a New Type of High-Energy Gamma-Ray Source

The EGRET source 3EG J1835+5918 is the brightest and most accurately positioned of the as-yet unidentified high-energy gamma-ray sources at high Galactic latitude (l, b = 89 deg, 25 deg). We present a multiwavelength study of the region around it, including X-ray, radio, and optical imaging surveys, as well as optical spectroscopic classification of most of the active objects in this area. Identifications are made of all but one of the ROSAT and ASCA sources in this region to a flux limit of approximately 5 x 10(exp -14) erg/sq cm s, which is 10(exp -4) of the gamma-ray flux. The identified X-ray sources in or near the EGRET error ellipse are radio-quiet QSOs, a galaxy cluster, and coronal emitting stars. We also find eight quasars using purely optical color selection, and we have monitored the entire field for variable optical objects on short and long time scales without any notable discoveries. The radio sources inside the error ellipse are all fainter than 4 mJy at 1.4 GHz. There are no flat-spectrum radio sources in the vicinity; the brightest neighboring radio sources are steep-spectrum radio galaxies or quasars. Since no blazar-like or pulsar-like candidate has been found as a result of these searches, 3EG J1835+5918 must be lacking one or more of the physically essential attributes of these known classes of gamma-ray emitters. If it is an AGN it lacks the beamed emission radio of blazars by at least a factor of 100 relative to identified EGRET blazars. If it is an isolated neutron star, it lacks the steady thermal X-rays from a cooling surface and the magnetospheric non-thermal X-ray emission that is characteristic of all EGRET pulsars. If a pulsar, 3EG J1835+5918 must be either older or more distant than Geminga, and probably an even more efficient or beamed gamma-ray engine. One intermittent ROSA T source falls on a blank optical field to a limit of B greater than 23.4, V greater than 23.3, and R greater than 22.5. In view of this conspicuous absence, RX J1836-2+5925 should be examined further as a candidate for identification with 3EG J1835+5918 and possibly the prototype of a new class of high-energy gamma-ray source.

Mirabal, N.↗

Vibration isolation and pressure compensation apparatus for sensitive instrumentation

A system for attenuating the inherent vibration associated with a mechanical refrigeration unit employed to cryogenically cool sensitive instruments used in measuring chemical constituents of the atmosphere is described. A modular system including an instrument housing and a reaction bracket with a refrigerator unit floated there between comprise the instrumentation system. A pair of evacuated bellows that "float' refrigerator unit and provide pressure compensation at all levels of pressure from seal level to the vacuum of space. Vibration isolators and when needed provide additional vibration damping for the refrigerator unit. A flexible thermal strap (20 K) serves to provide essentially vibration free thermal contact between cold tip of the refrigerator unit and the instrument component mounted on the IDL mount. Another flexible strap (77 K) serves to provide vibration free thermal contact between the TDL mount thermal shroud and a thermal shroud disposed about the thermal shaft.

Averill, R. D.↗

Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort

Thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours. Cross-Laminated Timber (CLT) and other mass wood products provide thermal mass to the building envelope in a lighter and more environmentally friendly form than concrete. However, the influence of CLTs on heating and cooling energy, peak energy demand, and the indoor climate is not well-known. This project was formed to find the energy efficiency benefits of mass timber structures. The objectives were to (1) test the thermal performance of insulated mass wall structures in controlled laboratory conditions, (2) validate simulation models to expand performance to natural climatic conditions, (3) isolate the impact of the thermal properties of wood (thermal mass, thermal conductivity, moisture storage) on heating and cooling energy use and peak energy demand, and to optimize the performance. Currently, the designs used for CLT buildings have focused on structural and fire issues, and they do not consider the thermal mass benefits. Therefore, the thermal performance is not necessarily optimized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microstructure Evolution During Controlled Solidification of “Fe{sub 2}O{sub 3}”-CaO-SiO{sub 2} Liquids in Air

The principal chemical components in iron ore sintering are Fe{sub 2}O{sub 3}, CaO, and SiO{sub 2}. This sintering process consists of three key steps: heating, holding at peak temperature, and cooling. During the cooling stage, a liquid oxide solidifies to form the final sinter microstructures. To investigate the fundamental processes taking place during the cooling of sinters, a new experimental technique has been developed that allows the stages of solidification to be determined in isolation, rather than inferred from the final microstructures. Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} oxide samples of a bulk composition having a CaO/SiO{sub 2} mass ratio of 3.46 and 73.2 wt pct Fe{sub 2}O{sub 3} were cooled in air from 1623 K (1350 °C) at 2 K/s, quenched at 5 K temperature intervals from 1533 K to 1453 K (1260 °C to 1180 °C), and analyzed using Electron Probe Micro X-Ray Analysis (EPMA). During cooling, four distinct stages were observed, consisting of the phase assemblages Liquid + Hematite (I), Liquid + Hematite + C{sub 2}S(II), Liquid + C{sub 2}S + CF{sub 2}(III), and C{sub 2}S + CF{sub 2} + CF (IV). This solidification sequence differs from that predicted under equilibrium and Scheil–Gulliver Cooling. Importantly, no Silico-Ferrite of Calcium (SFC) phase was observed to form on solidification of the liquid. Based on the microstructures formed and liquid compositions, measured by EPMA, it was demonstrated that kinetic factors play a major role in determining the phases and microstructures formed under the conditions investigated.

36 MATERIALS SCIENCE↗

Low-Temperature Geothermal Geospatial Datasets: An Example from Alaska

This project is a component of a broader effort focused on geothermal heating and cooling (GHC) with the aim of illustrating the numerous benefits of incorporating GHC and geothermal heat exchange (GHX) into community energy planning and national decarbonization strategies. To better assist private sector investment, it is currently necessary to define and assess the potential of low-temperature geothermal resources. For shallow GHC/GHX fields, there is no formal compilation of subsurface characteristics shared among industry practitioners that can improve system design and operations. Alaska is specifically noted in this work, because heretofore, it has not received a similar focus in geothermal potential evaluations as the contiguous United States. The methodology consists of leveraging relevant data to generate a baseline geospatial dataset of low-temperature resources (less than 150 degrees C) to compare and analyze information accessible to anyone trying to understand the potential of GHC/GHX and small-scale low-temperature geothermal power in Alaska (e.g., energy modelers, communities, planners, and policymakers). Importantly, this project identifies data related to (1) the evaluation of GHC/GHX in the shallow subsurface, and (2) the evaluation of low-temperature geothermal resource availability. Additionally, data is being compiled to assess repurposing of oil and gas wells to contribute co-produced fluids toward the geothermal direct use and heating and cooling resource potential. In this work we identified new data from three different datasets of isolated geothermal systems in Alaska and bottom-hole temperature data from oil and gas wells that can be leveraged for evaluation of low-temperature geothermal resource potential. The goal of this project is to facilitate future deployment of GHC/GHX analysis and community-led programs and update the low-temperature geothermal resources assessment of Alaska. A better understanding of shallow potential for GHX will improve design and operations of highly efficient GHC systems. The deployment and impact that can be achieved for low-temperature geothermal resources will contribute to decarbonization goals and facilitate widespread electrification by shaving and shifting grid loads.

15 GEOTHERMAL ENERGY↗

COOL YOUNG STARS IN THE NORTHERN HEMISPHERE: {beta} PICTORIS AND AB DORADUS MOVING GROUP CANDIDATES

As part of our continuing effort to identify new, low-mass members of nearby, young moving groups (NYMGs), we present a list of young, low-mass candidates in the northern hemisphere. We used our proven proper-motion selection procedure and ROSAT X-ray and GALEX-UV activity indicators to identify 204 young stars as candidate members of the {beta} Pictoris and AB Doradus NYMGs. Definitive membership assignment of a given candidate will require a measurement of its radial velocity and distance. We present a simple system of indices to characterize the young candidates and help prioritize follow-up observations. New group members identified in this candidate list will be high priority targets for (1) exoplanet direct imaging searches, (2) the study of post-T-Tauri astrophysics, (3) understanding recent local star formation, and (4) the study of local galactic kinematics. Information available now allows us to identify eight likely new members in the list. Two of these, a late-K and an early-M dwarf, we find to be likely members of the {beta} Pic group. The other six stars are likely members of the AB Dor moving group. These include an M dwarf triple system, and three very cool objects that may be young brown dwarfs, making them the lowest-mass, isolated objects proposed in the AB Dor moving group to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Cyclic, cryogenic, highly anisotropic plasma etching of silicon using SF{sub 6}/O{sub 2}

The authors report on the development and characterization of a plasma etching method that utilizes process steps common to both the well-known Bosch and the cryogenic deep reactive ion etching methods for silicon. This hybrid process uses cyclical etch steps that alternate between etching and passivating chemistries as in the Bosch process, while still maintaining sample temperatures at -100 deg. C on a cryogenically cooled stage. The advantages of this process are superior control of wall profiles for isolated features, minimization of grass formation, and the elimination of an expensive gas, c-C{sub 4}F{sub 8}, required in the Bosch passivation step. The authors show examples of x-ray optic elements deep etched to 100 {mu}m depth with the cyclic cryogenic process.

36 MATERIALS SCIENCE↗

Minimizing Grating Slope Errors in the IEX Monochromato at the Advanced Photon Source

The IEX beamline at the APS is currently in the commissioning phase. The energy resolution of the beamline was not meeting original specifications by several orders of magnitude. The monochromator, an in-focus VLS-PGM, is currently configured with a high and a medium-line-density grating. Experimental results indicated that both gratings were contributing to the poor energy resolution and this led to venting the monochromator to investigate. The initial suspicion was that a systematic error had occurred in the ruling process on the VLS gratings, but that proved to not be the case. Instead the problem was isolated to mechanical constraints used to mount the gratings into their respective side-cooled holders. Modifications were made to the holders to eliminate problematic constraints without compromising the rest of the design. Metrology performed on the gratings in the original and modified holders demonstrated a 20-fold improvement in the surface profile error which was consistent with finite element analysis performed in support of the modifications. Two gratings were successfully reinstalled and subsequent measurements with beam show a dramatic improvement in energy resolution.

Fisher, M. V.↗

Natural gas liquefaction employing independent refrigerant path

A method of liquefying natural gas. The method comprises cooling a gaseous natural gas process stream with a refrigerant flowing in a path isolated from the natural gas process stream. The refrigerant may differ in composition from a composition of the natural gas process stream, and the refrigerant composition may be selected to enhance efficiency of the refrigerant path with regard to a specific composition of the natural gas process stream. The refrigeration path may be operated at pressures, temperatures and flow rates differing from those of the natural gas process stream. Other methods of liquefying natural gas are described. A natural gas liquefaction plant is also described.

03 NATURAL GAS↗

The ISS 2B PVTCS Ammonia Leak: An Operational History

In 2006, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B power channel began leaking ammonia at a rate of approximately 1.5lbm/year (out of a starting approximately 53lbm system ammonia mass). Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity during the STS‐134 mission. During this mission the system was topped off with ammonia piped over from a separate thermal control system. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. Without these periodic EVAs to refill the 2B coolant system, the channel would eventually leak enough fluid as to risk pump cavitation and system failure, resulting in the loss of the 2B power channel - the most critical of the Space Station's 8 power channels. In mid‐2012, the leak rate increased to approximately 5lbm/year. Once discovered, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to a dormant thermal control system not intended to be utilized as anything other than spare components. The purpose of this rerouting of the TCS was to increase system volume and to isolate the photovoltaic radiator, thought to be the likely leak source. This EVA was successfully executed on November 1st, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a totally different radiator than what the system was designed to utilize. Unfortunately, data monitoring over the next several months showed that the isolated radiator was not leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the crew noticing the leak, an EVA was in progress to replace the coolant pump - the only other replaceable leak source. This paper will explore the management of the 2B PVTCS leak from the operations perspective. It will discuss the methodology of performing the STS‐134 refill, the considerations and contingency plans which went into the architectural overhaul of the system in 2012, and the unprecedented effort which went into the EVA response to the visible leak of May 2013. In particular the paper will focus on the techniques utilized by flight controllers to monitor the system health and to respond to such instances as the rapid May 2013 leak by putting the electrical system in a safe configuration for loss of cooling, and will use recorded telemetry of these events to describe system response to EVA crew and ground actions. It will discuss the innovative design for redundancy of the integrated truss structure's cooling systems which allowed for this leak to be managed with minimal impact to other ISS operations and electrical services, contrasted against the real unintended operations consequences of utilizing the flexibility of the spacecraft's design in this manner. The paper will discuss how the training of the crew and flight controller personnel has adapted to the changing architecture of the power system and the unpredictable nature of the 2B leak.

Vareha, Anthony↗

PNNL streamlines energy-guzzling computers

In a room the size of a garage, two rows of six-foot-tall racks holding supercomputer hard drives sit back-to-back. Thin tubes and wires snake off the hard drives, slithering into the corners. Stepping between the rows, a rush of heat whips around you -- the air from fans blowing off processing heat. But walk farther in, between the next racks of hard drives, and the temperature drops noticeably. These drives are being cooled by a non-conducting liquid that runs right over the hardworking processors. The liquid carries the heat away in tubes, saving the air a few degrees. This is the Energy Smart Data Center at Pacific Northwest National Laboratory. The bigger, faster, and meatier supercomputers get, the more energy they consume. PNNL's Andres Marquez has developed this test bed to learn how to train the behemoths in energy efficiency. The work will help supercomputers perform better as well. Processors have to keep cool or suffer from "thermal throttling," says Marquez. "That's the performance threshold where the computer is too hot to run well. That threshold is an industry secret." The center at EMSL, DOE's national scientific user facility at PNNL, harbors several ways of experimenting with energy usage. For example, the room's air conditioning is isolated from the rest of EMSL -- pipes running beneath the floor carry temperature-controlled water through heat exchangers to cooling towers outside. "We can test whether it's more energy efficient to cool directly on the processing chips or out in the water tower," says Marquez. The hard drives feed energy and temperature data to a network server running specially designed software that controls and monitors the data center. To test the center’s limits, the team runs the processors flat out – not only on carefully controlled test programs in the Energy Smart computers, but also on real world software from other EMSL research, such as regional weather forecasting models. Marquez's group is also developing "power aware computing", where the computer programs themselves perform calculations more energy efficiently. Maybe once computers get smart about energy, they'll have tips for their users.

data center↗

Development of a He{sup 3}−He{sup 4} sub Kelvin active magnetic regenerative refrigerator (AMRR) with no moving parts

Current state of the art particle and photon detectors such as Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) use large arrays of sensors or detectors for space science missions. As the size of these space science detectors increases, future astrophysics missions will require sub-Kelvin cooling over larger areas. This leads to not only increased cooling power requirements, but also a requirement for distributed sub-Kelvin cooling. We propose an active Magnetic Regenerative Refrigerator (AMRR) that uses a Superfluid Magnetic Pump (SMP) to circulate liquid He{sup 3}−He{sup 4} through a magnetic regenerator to provide the necessary cooling at sub-Kelvin temperatures. Such system will be capable of distributing the cooling load to a relatively large array of objects. One advantage of using a fluid for heat transfer in such systems is to isolate components such as the superconducting magnets from detectors that are sensitive to magnetic fields. Another advantage of the proposed tandem AMRR is that it does not need Gas Gap Heat Switches (GGHS) to transfer heat during various stages of the magnetic cooling. Our proposed system consists of four superconducting magnets, one superleak, and three heat exchangers. It will operate continuously with no moving parts and it will be capable of providing the necessary cooling at sub-Kelvin temperatures for future space science applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Applications of a Venus thermospheric circulation model

A variety of Pioneer Venus observations suggest a global scale, day-to-night Venus thermospheric circulation. Model studies of the dynamics and energetics of the Venus thermosphere are presented in order to address new driving, mixing and cooling mechanisms for an improved model simulation. The adopted approach was to reexamine the circulation by first using a previous two dimensional code to quantify those physical processes which can be inferred from the Pioneer Venus observations. Specifically, the model was used to perform sensitivity studies to determine the degree to which eddy cooling, eddy or wave drag, eddy diffusion and 15 micrometer radiational cooling are necessary to bring the model temperature and composition fields into agreement with observations. Three EUV heating cases were isolated for study. Global temperature and composition fields in good agreement with Pioneer data were obtained. Large scale horizontal winds 220 m/s were found to be consistent with the observed cold nightside temperatures and dayside bulges of O, CO and CO2. Observed dayside temperatures were obtained by using a 7 to 19% EUV heating efficiency profile. The enhanced 15 micrometer cooling needed for thermal balance is obtained using the best rate coefficient available for atomic O collisional excitation of CO2(0,1,0). Eddy conduction was not found to be a viable cooling mechanism due to the weakened global circulation. The strong 15 micrometer damping and low EUV efficiency imply a very weak dependence of the general circulation to solar cycle variability. The NCAR terrestrial thermospheric general circulation model was adapted for Venus inputs using the above two dimensional model parameters, to give a three dimensional benchmark for future Venus modelling work.

Bougher, S. W.↗

The detection of distant cooling flows and the formation of dark matter

Cooling flows involving substantial mass inflow rates appear to be common in many nearby rich and poor clusters and in isolated galaxies. The extensive optical and ultraviolet filaments produced by the thermal instability of large flows are detectable out to redshifts greater than 1. It is proposed that this may explain the extended optical line emission reported in, and around, many distant radio galaxies, narrow-line quasars, and even nearby normal and active galaxies. An important diagnostic to distinguish cooling flows from other possible origins of emission line filaments is the presence of extensive regions at high thermal pressure. Other evidence for distant cooling flows and the resultant star formation is further discussed, together with the implications of cooling flow initial-mass functions for galaxy formation and the nature of 'dark' matter.

Fabian, A. C.↗