Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ionizing radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A system identification approach for non-intrusive reduced order modeling of radiation-induced photocurrents

In this study, development of compact photocurrent models is currently dominated by analytical techniques that rely on physical assumptions to render the governing equations solvable in a closed form. Violation of these assumptions can reduce the accuracy of the models and/or limit their scope. In this paper we show that system identification of nonlinear state-space systems can serve as an alternative numerical basis for non-intrusive reduced order modeling of photocurrent effects. To that end we develop a compact gray box photocurrent model (GBPM) by using a state-space representation with a low-dimensional latent state equation that mimics a mathematical model for the response of an idealized class of devices to ionizing radiation. In so doing we obtain a model that learns the dynamics of a quantity of interest directly from its measurements without requiring snapshots of the internal device state or its discretized model, and can be inferred from very small data sets. To demonstrate the approach we train the GBPM using a small experimental data set for a Z5236 Zener diode and a small synthetic data set obtained by simulating a synthetic pn-junction device. We then compare the GBPMs with black box models trained on the same data and show that performance of the latter is limited by the size of the data set, while the former are able to achieve excellent performance in both the reproductive and the predictive regimes.

97 MATHEMATICS AND COMPUTING↗

Fast Neutron Irradiation of a Multichannel JFET-Based Optical Encoder

Modern electrical components are susceptible to damage from high levels of radiation and extreme temperatures found near reactors in terrestrial nuclear power plants and in aerospace applications. Radiation-hardened electronics are being developed, largely for the aerospace industry, but they sometimes rely on application-specific, small-batch semiconductor fabrication processes. These processes tend to be prohibitively expensive to develop and maintain outside major industrial facilities or governmental agencies. Recently, commercially available, nonradiation-rated junction-gate field-effect transistors (JFETs) were shown to maintain their functionality at gamma doses exceeding 1 MGy, suggesting that nonrated, commercially available electrical components could be used to develop systems that are tolerant to ionizing radiation. However, gamma ray survival is not indicative of neutron dose survival, and few studies characterize JFETs under neutron irradiation. To address this knowledge gap, a JFET-based analog multiplexer and optical pulsewidth modulation (PWM) encoder was developed and irradiated using a 252 Cf source to 1.6×10 13 n/cm 2 . The multiplexed optical encoder (MOE) system maintained functionality throughout testing and showed little evidence of radiation effects. These results indicate that circuitry tolerant to fast neutron damage can be developed using low-cost, nonradiation-rated, commercially available JFETs, which could provide a lower production cost alternative to specialized semiconductor processes when designing and building electronics better able to survive neutron irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of Quasar Proximity Zones with the Lyα Forest of DESI Y1 Quasars

Abstract The intergalactic medium (IGM) around a quasar is shaped by its dense environment and by its excess ionizing radiation, which form a “quasar proximity zone” whose size and anisotropy depend on the quasar’s halo mass, luminosity, age, and radiation geometry. Using over 10,000 quasar pairs from the Dark Energy Spectroscopic Instrument (DESI) Year 1 data, with projected comoving separations r ⊥ < 2 h −1 Mpc, we investigate how the proximity zone of foreground quasars at z ∼ 2–3.5 affects Lyα absorption in their background quasars. The large DESI sample enables unprecedented precision in measuring this “transverse proximity” effect, allowing a detailed investigation of the signal’s dependence on the projected separation of quasar pairs and the luminosity of the foreground quasar. We find that enhanced gas clustering near quasars dominates over their ionizing effect, leading to stronger absorption on neighboring sightlines. Under the assumption that quasar ionizing luminosity is isotropic and steady, we infer the IGM overdensity profile in the vicinity of quasars, finding overdensities as high as Δ ∼ 10 at comoving distance ∼1 h −1 Mpc from the most luminous systems. Surprisingly, however, we find no significant dependence of the proximity profile on the luminosity of the foreground quasar. This lack of luminosity dependence could reflect a cancellation between higher ionizing flux and higher gas overdensity, or it could indicate that quasar emission is highly time-variable or anisotropic, so that the observed luminosity does not trace the ionizing flux on nearby sightlines.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing novel Indium Phosphide pad detectors with focused X-ray beams and laboratory tests

Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indium Phosphide pad sensors were fabricated at Argonne National Lab using commercially available InP:Fe 2-inch mono-crystal substrates. Current-voltage and capacitance-voltage characterizations were performed to study the basic operating characteristics of a group of sensors. Micro-focused X-ray beams at Canadian Light Source and Diamond Light Source were used to study the response to ionizing radiation, and characterize the uniformity of the response for several devices. Electrical test results showed a high degree of performance uniformity between the 48 tested devices. X-ray test beam results showed good performance uniformity within tested devices after accounting for spatially-local defects and edge fields. As a result, this motivates further studies into thin film devices for future tracking detectors.

47 OTHER INSTRUMENTATION↗

Distributed Fiber Sensors With High Spatial Resolution in Extreme Radiation Environments in Nuclear Reactor Cores

This paper is a comprehensive experimental report on the neutron radiation effects of distributed optical fiber sensors with enhanced Rayleigh scattering profiles in an in-pile environment. Femtosecond laser direct writing was used to inscribe Type-II modifications in standard telecom fibers and radiation-hardened fibers with fluorine-doped cores. Rayleigh backscattering signals were enhanced for continuous 1.5 m. In-pile lead-out sensors tests were carried out at the MIT Research Reactor for two months, which was operated at a nominal power of 5.7 MW with fast neutron (>0.1 MeV) flux of 1.29 × 1014 n/cm2/s and an in-core temperature of up to 560°C. Using the Optical Frequency Domain Reflectometry technique, the backscattering profiles of fiber sensors were interrogated with a 3-cm spatial resolution to monitor the temperature profile of the reactor. Results show that laser inscribed Type-II modifications in the form of nanogratings are highly stable against extreme temperature and ionizing radiation. Both standard telecom fibers and radiation-hardened fibers with laser-enhanced Rayleigh profiles can continuously perform distributed temperature measurements over the entire duration of the in-pile testing. Temperature coefficients of sensors and spectral shift quality were studied as functions of total radiation fluence. To the best of our knowledge, we present for the first time, the temperature profile of an operating nuclear reactor core with 3-cm spatial resolution, enabled by distributed fiber sensors with laser-enhanced Rayleigh scattering profiles. The high spatial resolution measurements can provide valuable data for the design and validation of digital twin and virtual reality of nuclear energy systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advances in Autoradiography Systems for Nuclear Forensic Analysis

Nuclear forensic analysis techniques work to determine the contents of radiological samples with nondestructive and destructive analysis methods. Autoradiography is a nondestructive analysis method that creates an image of the distribution of radioactivity within the sample. These images allow the location of the radiological content within a sample to be ascertained, which can be used for further analysis. Autoradiography has been used since the discovery of radiation and has been continuously developed to better suit the needs of the medical, nuclear security, nuclear safeguards, and nuclear forensic communities. Recent developments in autoradiography have led to a higher spatial resolution down to a level of tens of microns, real-time capabilities that minimize the risk of overexposure, and the ability to discriminate particles. All of these developments in autoradiography would assist the nuclear forensics community in understanding the placement of radiological content within a sample and in understanding the locations of beta-particle interactions versus those for alpha-particle interactions. This article aims to discuss the history of autoradiography as well as multiple different autoradiographic technologies while focusing on imaging plates, the BeaQuant system, and the ionizing-radiation Quantum Imaging Detector system. This article reviews three autoradiographic techniques and detectors, discusses how they relate to nuclear forensics, and addresses the drawbacks and benefits of each detector.

Autoradiography↗

Radiation-Induced Chemical Yields of Carbon-Centered Radicals and Hydrogen Atoms from the Gamma Irradiation of n -Dodecane

Here, this study investigates the radiolytic yields of carbon-centered radicals and hydrogen atoms in n-dodecane under gamma irradiation. Utilizing molecular iodine (I 2 ) and 2,4,6-tri-tert-butylnitrosobenzene (3tBNB) as radical scavengers, we quantified the yields of molecular hydrogen and various carbon-centered radicals formed from bond scission of the solvent excited states. The yield of primary alkyl radicals was significantly lower than that of the secondary radicals, aligning with expected stabilities and bond dissociation energies. For the overall loss of n-dodecane, total yields of 0.598 ± 0.004 species/100 eV for C–C bond scission, 1.648 ± 0.012 species/100 eV for C–H bond scission, and 3.20 ± 0.10 species/100 eV for unimolecular H 2 elimination were determined. Notably, the I 2 scavenging data provided robust estimates, while the 3tBNB displayed lower efficiency in radical trapping. This research enhances our understanding of radiolytic processes in n-dodecane and offers insights for future studies on the behavior of hydrocarbons under ionizing radiation, with implications for improving UNF reprocessing strategies.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

A Reconfigurable Neural Network ASIC for Detector Front-End Data Compression at the HL-LHC

Despite advances in the programmable logic capabilities of modern trigger systems, a significant bottleneck remains in the amount of data to be transported from the detector to off-detector logic where trigger decisions are made. We demonstrate that a neural network (NN) autoencoder model can be implemented in a radiation-tolerant application-specific integrated circuit (ASIC) to perform lossy data compression alleviating the data transmission problem while preserving critical information of the detector energy profile. For our application, we consider the high-granularity calorimeter from the Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider. The advantage of the machine learning approach is in the flexibility and configurability of the algorithm. By changing the NN weights, a unique data compression algorithm can be deployed for each sensor in different detector regions and changing detector or collider conditions. To meet area, performance, and power constraints, we perform quantization-aware training to create an optimized NN hardware implementation. The design is achieved through the use of high-level synthesis tools and the hls4ml framework and was processed through synthesis and physical layout flows based on a low-power (LP)-CMOS 65-nm technology node. The flow anticipates 200 Mrad of ionizing radiation to select gates and reports a total area of 3.6 mm 2 and consumes 95 mW of power. The simulated energy consumption per inference is 2.4 nJ. Furthermore, this is the first radiation-tolerant on-detector ASIC implementation of an NN that has been designed for particle physics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-induced reaction kinetics of Zn 2+ with e S - and Cl 2 ˙ - in Molten LiCl–KCl eutectic at 400–600 °C

We report molten chloride salts are currently under consideration as combined coolant and liquid fuel for next-generation molten salt nuclear reactors. Unlike complementary light-water reactor technologies, the radiation science underpinning molten salts is in its infancy, and thus requires a fundamental mechanistic investigation to elucidate the radiation-driven chemistry within molten salt reactors. Here we present an electron pulse radiolysis kinetics study into the behaviour of the primary radiolytic species generated in molten chloride systems, i.e., the solvated electron (e S - ) and di-chlorine radical anion (Cl 2 ˙- ). We examine the reaction of e S - with Zn 2+ from 400–600 °C (E a = 30.31 ± 0.09 kJ mol -1 ), and the kinetics and decay mechanisms of Cl 2 ˙- in molten lithium chloride-potassium chloride (LiCl–KCl) eutectic. In the absence of Zn 2+ , the lifetime of e S - was found to be dictated by residual impurities in ostensibly “pure” salts, and thus the observed decay is dependent on sample history rather than being an intrinsic property of the salt. The decay of Cl 2 ˙- is complex, owing to the competition of Cl 2 ˙- disproportionation with several other chemical pathways, one of which involves reduction by radiolytically-produced Zn + species. Overall, the reported findings demonstrate the richness and complexity of chemistry involving the interactions of ionizing radiation with molten salts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nitrogen‐Nitrogen Bond Breaking in Irradiation Products of Hexanitrohexaazaisowurtzitane (CL‐20)

While the primary result of an interaction of ionizing radiation with an organic material is the ejection of electrons from molecular orbitals producing cations, the free electrons can further interact, yielding excited states; and, potentially, anions. In this work, we computed reaction barriers and energies for N−N bond breaking in the CL-20 cation, anion, and excited state to investigate if CL-20 degradation is accelerated after radiation exposure. We focused on N−N bond dissociation because it is the rate-determining step in the thermal degradation of CL-20. We found that N−N cleavage rapidly takes place in the CL-20 cation and anion with greatly reduced reaction energies as compared to CL-20. We also outlined a potential path for photodissociation of the N−N bond. While CL-20 is kinetically stable, initial degradation occurs readily in its irradiation products. In conclusion, this is of importance for the performance of the explosive after high-dose exposure and influences aging if CL-20 is irradiated at a low dose over extended periods of time.

CL-20 anion↗

Thermal Performance of Perovskite-Based Photovoltaics for Operation in Low Earth Orbit

Perovskite-based photovoltaics are attractive for applications in space. The space environment is harsh with ionizing radiation, atomic oxygen, UV radiation, extreme temperatures, and thermal cycling. Herein, the thermal performance of perovskite active layer and perovskite photovoltaic devices in low earth orbit is analyzed. A 1 μm silicon oxide layer coupled with 500 nm zirconia thin film aid in cell thermal management is determined. The residual stresses between various layers in a device are modeled and it is proved that thermally induced mechanical failure of the perovskite (time > 460 years) is unlikely during operating lifetime of any mission. In conclusion, target power conversion efficiencies are also shared to manage maximum operating temperature of a perovskite-based device.

14 SOLAR ENERGY↗

Nanoparticles for targeted cancer radiotherapy

Radiotherapy, where ionizing radiation is locally delivered either through an external beam or by surgically implanting radionuclide-based seeds in the tumor, is one of the gold standard treatments for cancer. Due to the non-selective nature of radiation, healthy tissue surrounding the cancerous region is usually affected by the treatment. Hence, new strategies, including targeted alpha therapy, are being studied to improve the selectivity of the treatment and minimize side effects. Several challenges, however, limit the current development of targeted radiotherapy, such as the functionalization of the therapeutic agent with targeting vectors and controlling the release of recoiling daughters. Nanoparticles offer unique opportunities as drug delivery vehicles, since they are biocompatible, enhance the cellular uptake of drugs, and are easily functionalized with targeting molecules. In this review, we examine how nanoparticles can be used for targeted radiotherapy, either as sensitizers of external beams or as delivery vehicles for therapeutic radionuclides. Further, we describe the clinical relevance of different types of nanoparticles, followed by an analysis of how these nanoconstructs can solve some of the main limitations of conventional radiotherapy. Finally, we critically discuss the current situation of nanoparticle-based radiotherapy in clinical settings and challenges that need to be overcome in the future for further development of the field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-resolution modeling of indoor radon exposure with uncertainty quantification in Utah

Indoor radon accounts for 37% of population-level exposure to ionizing radiation in the United States. However, radon metrics are typically reported at coarse spatial scales, potentially obscuring meaningful local variation. We developed a high-resolution modeling framework to estimate indoor radon concentrations across Utah while explicitly quantifying predictive uncertainty. A total of 19,497 residential radon measurements collected between 2006 and 2017 were combined with environmental and housing characteristics and analyzed using a geospatial neural network that accommodates spatial dependence and nonlinear associations. Predictions were generated on a uniform hexagonal grid at 0.73 km2 resolution (H3 level 8). Out-of-sample predictions aggregated to the H3 level 8 grid showed good agreement with observed concentrations (Pearson r=0.64), while household-level predictions exhibited more moderate agreement (r=0.45). The model produced well-calibrated uncertainty estimates, with 24.1% of held-out observations exceeding the predicted 75th-percentile threshold. Maps of predicted radon concentrations and the probability of exceeding the U.S. EPA action level of 148 Bq/m3 (4 pCi/L) revealed substantial fine-scale spatial heterogeneity that was not apparent in conventional coarse-resolution summaries, with greater local variability observed in densely monitored urban counties than in sparsely sampled regions. High-resolution radon models that explicitly quantify uncertainty provide a useful framework for characterizing the spatial distribution of indoor radon and identifying areas of elevated exceedance risk. These findings highlight the value of fine-scale monitoring data and uncertainty-aware modeling approaches for radon exposure assessment, environmental risk characterization, and radon-related health research.

Wu, Yunhan [ORNL] (ORCID:0000000178842994)↗

Development of diamond-based diagnostics for next-generation XFELs

The composition and performance of three different diamond sensor based pass-through diagnostics are presented. A position-sensitive quadrant sensor was designed and characterized using the XPP beam at the SLAC LCLS, demonstrating a generated-charge resolution of 0.025 pC and a position sensitivity of 2 μm, measurable pulse-by-pulse at a repetition rate of up to 50 MHz. A compact signal path capable of repetition rates up to 1 GHz was used to characterize the charge collection properties of diamond sensors as a function of the density of electron-hole pairs created within the sensor, finding a limit of approximately 10 16 electron-hole pairs per cm 3 beyond which the collection efficiency and time began to degrade. Finally, a proposed scheme for measuring ionizing radiation at multi-GHz rates is presented, along with results preliminarily demonstrating signal transport capability in excess of 5 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An electrochemical generator for the continual supply of 213 Bi from 225 Ac for use in targeted alpha therapy applications

Bismuth-213 is a radionuclide of interest for targeted alpha therapy and is supplied via a radiochemical generator system through the decay of 225 Ac. Radionuclide generators employ longer lived “parent” radionuclides to routinely supply shorter-lived “daughter” radionuclides. The traditional 225 Ac/ 213 Bi radiochemical generator relies on an organic cation exchange resin where 225 Ac binds to the resin and 213 Bi is routinely eluted. These resins degrade when they absorb large doses of ionizing radiation (>1 × 10 6 Gy/mg), which has been observed when the loading activity of 225 Ac exceeds 2.59*10 9 Bq (70 mCi). Herein we report the development of an electrochemical generator for the supply of 213Bi that has the potential to overcome this limitation. Bismuth-213 spontaneously electrodeposits onto nickel foils in 0.1 M hydrochloric acid at 70 °C. Using this method, we were able to plate an average of 73 ± 4 % of the 213 Bi in solution and obtain a final 213 Bi recovery of 65 ± 8 % in 0.1 M citrate pH 4.5 via reverse electrolysis using titanium as the cathode. The recovered 213Bi had an average radiochemical purity of >99.8 % and was successfully used to radiolabel DOTATATE with an average radiochemical yield of 85.1 % (not optimized).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗