Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instrumental resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Investigation of NO2 Measurements Made During DISCOVER-AQ and KORUS-AQ Campaigns in Conjunction with NO2 Tropospheric Column from the Ozone Monitoring Instrument (OMI) and High-Resolution Community Multi-Scale Air Quality (CMAQ) Model Simulation

Atmospheric NO2 is produced by combustion, lightning, and in soil. NO2 affects ozone production and criteria pollutant itself.It also has indirect radiative impacts in the troposphere, since ozone has largest warming effect in upper troposphere. Tropospheric vertical column densities (VCD) of NO2 are available from satellites (GOME, OMI, SCIAMACHY, GOME-2). DISCOVER-AQ and KORUS-AQ aircraft campaigns we reconducted to improve the use of satellites to monitor air quality for public health and environmental benefit in United States and South Korea. In this study, we investigate 1) How do these measurements compare? 2) What is the best way to make comparisons of space- and ground-based measurements?

multi-scale air quality↗

Desmearing two-dimensional small-angle neutron scattering data by central moment expansions

Resolution smearing is a critical challenge in the quantitative analysis of two-dimensional small-angle neutron scattering (SANS) data, particularly in studies of soft-matter flow and deformation using SANS. Here, we present a central moment expansion technique to address smearing in anisotropic scattering spectra, offering a model-free desmearing methodology. By accounting for directional variations in resolution smearing and enhancing computational efficiency, this approach reconstructs desmeared intensity distributions from smeared experimental data. Computational benchmarks using interacting hard-sphere fluids and Gaussian chain models validate the accuracy of the method, while simulated noise analyses confirm its robustness under experimental conditions. Experimental validation using rheological SANS data from shear-induced micellar structures demonstrates the practicality and effectiveness of the proposed algorithm. The desmearing technique provides a powerful tool for advancing the quantitative analysis of anisotropic scattering patterns, enabling precise insights into the interplay between material microstructure and macroscopic flow behavior.

anisotropic scattering spectra↗

Imaging Carrier Dynamics and Transport in Hybrid Perovskites with Transient Absorption Microscopy

In this review, the recent progress in using transient absorption microscopy to image charge transport and dynamics in semiconducting hybrid organic–inorganic perovskites is discussed. The basic principles, instrumentation, and resolution of transient absorption microscopy are outlined. With temporal resolution as high as 10 fs, sub-diffraction-limit spatial resolution, and excited-state structural resolution, these experiments have provided crucial details on charge transport mechanisms that have been previously obscured in conventional ultrafast spectroscopy measurements. Morphology-dependent mapping unveils spatial heterogeneity in carrier recombination and cooling dynamics. By spatially separating the pump and probe beams, carrier transport across grain boundaries has been directly visualized. Further, femtosecond temporal resolution allows for the examination of nonequilibrium transport directly, revealing extraordinarily long-range hot carrier migration. The application of transient absorption microscopy is not limited to hybrid perovskites but can also be useful for other polycrystalline materials in which morphology plays an important role in carrier transport.

36 MATERIALS SCIENCE↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Deep learning based event reconstruction for cyclotron radiation emission spectroscopy

The objective of the cyclotron radiation emission spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time–frequency plane. Due to the need for excellent instrumental energy resolution in application, highly efficient and accurate track reconstruction methods are desired. Deep learning convolutional neural networks (CNNs) - particularly suited to deal with information-sparse data and which offer precise foreground localization—may be utilized to extract track properties from measured CRES signals (called events) with relative computational ease. In this work, we develop a novel machine learning based model which operates a CNN and a support vector machine in tandem to perform this reconstruction. A primary application of our method is shown on simulated CRES signals which mimic those of the Project 8 experiment—a novel effort to extract the unknown absolute neutrino mass value from a precise measurement of tritium β - -decay energy spectrum. When compared to a point-clustering based technique used as a baseline, we show a relative gain of 24.1% in event reconstruction efficiency and comparable performance in accuracy of track parameter reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical alignment of high resolution Fourier transform spectrometers

Remote sensing, high resolution FTS instruments often contain three primary optical subsystems: Fore-Optics, Interferometer Optics, and Post, or Detector Optics. We discuss the alignment of a double-pass FTS containing a cat's-eye retro-reflector. Also, the alignment of fore-optics containing confocal paraboloids with a reflecting field stop which relays a field image onto a camera is discussed.

Breckinridge, J. B.↗

New far infrared observations of the central 30 arcmin of the Galaxy

Observations of the 55 micron and 125 micron emissions of the central 30 arcmin of the Galaxy were performed with 1 arcmin resolution with instrumentation on-board the Kuiper flying observatory. The flux distributions detected showed both wavelengths with peaks near the galactic center, some extension along the galactic plane, and the 125 micron feature located 30 arcsec south. An asymmetry was found around Sgr A, and the variation in dust temperature across the region was calculated from the ratio of the two wavelengths. The temperature peak was around Sgr A, with subsidiary peaks associated with the 55 micron emission. A common heating source was indicated by correlations between cm wavelength sources and the temperature maps. Additionally, the distributions of NH3 and formaldehyde were also correlated with the dust distribution at the center.

Dent, W. A.↗

On absorption by hot interstellar gas. II - The 5303-A forbidden line of Fe XIV

Spectroscopic observations of 29 stars at 5303 A obtained with the coude spectrograph on the 2.7-m reflector at McDonald Observatory during 1979-1983 are reported. Instrumental FWHM resolution is 27, 54, or 10 pm, and detection limits near 100 fm equivalent width are obtained in optimal cases. The results are presented in tables and a diagram. No absorption attributable to Fe XIV in hot interstellar gas is detected except for HD 93521, on Apr. 10, 1981, only. This absorption can be located either in interstellar gas at 1.2 million K or less with an Fe XIV/Fe X ratio greater than 3 or in hot gas confined in an inhomogeneous stellar corona.

Hobbs, L. M.↗

Velocity-resolved observations of water in Comet Halley

An infrared spectrum of comet Halley was recorded at the Kuiper Airborne Observatory with an instrumental velocity resolution of 1.1 km/sec. A total of 13 emission lines in the 2.65 micron spectral region were assigned to neutral gaseous H2O : 10 in the 001 to 000 band and 3 in the hot 011 to 010 band. The position and widths of these lines are functions of the gas velocity field in the coma. Analysis indicates that the neutral gas outflow is widely dispersed about the nucleus. This spectroscopic picture is consistent with spacecraft images that show multiple jets releasing material into most of the sunfacing hemisphere.

Larson, Harold P.↗

A search for millisecond periodic and quasi-periodic pulsations in low-mass X-ray binaries

The results of a Fourier analysis to detect fast periodic and quasi-periodic pulsations in the X-ray emission from the sources 4U 0614 + 091, 4U 1636 - 536, 4U 1735 - 44, 4U 1820 30, GX 5 - 1, GX 9 + 9, Ser X-1, and Cyg X-2 are presented. This search has been carried out for the first time in the soft energy band (0.2-2.0 keV), using data from the Einstein Observatory high resolution imager instrument. An approximate method of minimizing the decrease in search sensitivity produced by the Doppler shift of the pulse periods due to source orbital motion is discussed. No pulsations have been detected, and upper limits, which depend on the orbital parameters assumed for the sources, are set on the pulsed flux fraction.

Mereghetti, S.↗

Results of a search for a new class of GRBS in the SMM data

The results of a search for the soft and short Gamma-Ray Bursts (GRBs) in the data of the Hard X-Ray Burst Spectrometer (HXRBS) on the Solar Maximum Mission (SMM) are presented. Data for four events are presented, including their time profiles and spectral characteristics. In one case the instrument time resolution reveals a total burst duration of 55 ms with rise and decay times of less than about 5 ms.

Kouveliotou, C.↗

The basis for the spectral behaviour of silicates in the thermal infrared and applications to remote sensing

Variations in the thermal infrared (TIR) spectral response of silicate rocks is related to changes in the structures and divalent cation contents of the minerals which form the rocks. These considerations lead to a chemical parameter, SCFM, which reflects mineral structures, rock types, and their spectra. The parameter is the ratio of silica to the abundance of depolymerizing cations, defined as SCFM = SiO2/SiO2 + CaO + MgO + FeO. Parameter SCFM is therefore proposed for use in TIR remote sensing of igneous rocks. It is also demonstrated that two or three broad bands are sufficient for distinguishing among major rock types and the system noise has little effect on the quality of the results. These factors can be traded off against improved spatial resolution in instrument design.

Walter, L. S.↗

A multi-wavelength study of the peculiar galaxy NGC 2976

Researchers are currently studying NGC 2976 at many wavelengths to investigate the extent to which an interaction with M81 may have affected the star formation history of this galaxy. Here, researchers present observations of NGC 2976 made at 50 microns with the high resolution (CPC) instrument onboard Infrared Astronomy Satellite (IRAS) at 21-cm (both HI line and radio continuum) with the Westerbork Synthesis Radio Telescope (WSRT) and in the H alpha line with the Kitt Peak National Observatory (KPNO) 36 inch telescope. The far infrared emission is not centrally peaked as in other spirals (e.g., Wainscoat et al. 1987), but has obvious intensity peaks near the ends of the disk. The ionized gas as inferred from the H alpha observations, is largely confined to two large, symmetrically placed emission regions near the ends of the disk. Finally, the HI and 21-cm radio continuum emission also exhibit this strongly double-peaked structure. At all of the above wavelengths the emission peaks are roughly coincident and lie approx. 1.2 minutes to the NW and approx. 1.1 minutes to the SE of the optical center of this galaxy.

Tacconi, L. J.↗

Comet Brorsen-Metcalf in the 3.5 micron region

Comet Brorsen-Metcalf was observed on UT 21 to 24 Aug. 1989 using the CRSP spectrometer and the 1.3 meter telescope at Kitt Peak National Observatory. The cometary continuum was detected on all nights. The data are very noisy, due to the short observation window and the untried nature of the instrument. Low resolution (0.0227 micron) spectra show the 3.4 micron C-H stretch feature having a contrast of at most a factor of two to the neighboring continuum. High resolution (0.0031 micron) spectra between 3.4 and 3.6 microns show 1 sigma features that might be attributed to the nu 5 band of formaldehyde (H2CO). Similar spectra of the region between 3.2 and 3.4 microns show one 3 sigma line at 3.34 microns, which is as yet unidentified. Although the cometary spectra were more spatially extended than the spectra of standard stars, no extension of the line emission beyond the continuum was observed.

Storrs, A. D.↗

The MIT high resolution X-ray spectroscopy instruments on AXAF

The general design and performance characteristics of MIT's two dispersive spectrometers, the Bragg Crystal Spectrometer (BCS) and the High Energy Transmission Grating Spectrometer (HETG), now being developed for the Advanced X-ray Astrophysics Facility (AXAF), are described. Particular attention is given to the development of the critical technologies incorporated into these instruments, including BCS diffractors, imaging gas flow proportional counters, and grating elements for the HETG. The principal stages and the current status of the developments are reviewed.

Canizares, C. R.↗