Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installed capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Opportunities for and challenges to further reductions in the “specific power” rating of wind turbines installed in the United States

A wind turbine’s “specific power” rating relates its capacity to the swept area of its rotor in terms of Watt per square meter. For a given generator capacity, specific power declines as rotor size increases. In land-rich but capacity-constrained wind power markets, such as the United States, developers have an economic incentive to maximize megawatt-hours per constrained megawatt, and so have favored turbines with ever-lower specific power. To date, this trend toward lower specific power has pushed capacity factors higher while reducing the levelized cost of energy. We employ geospatial levelized cost of energy analysis across the United States to explore whether this trend is likely to continue. We find that under reasonable cost scenarios (i.e. presuming that logistical challenges from very large blades are surmountable), low-specific-power turbines could continue to be in demand going forward. Beyond levelized cost of energy, the boost in market value that low-specific-power turbines provide could become increasingly important as wind penetration grows.

geospatial modeling↗

Solar Industry Update: (H2 2020) [Slides]

Each quarter, the National Renewable Energy Laboratory (NREL) conducts the Quarterly Solar Industry Update, a presentation of technical trends within the solar industry, to the solar office staff. Each presentation focuses on global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry.

14 SOLAR ENERGY↗

2021 Prototype Testing Awardee: Sonsight Wind

For small wind turbines - those under 10 kilowatts (kW) in generating capacity - the combined costs for turbines, towers, foundations, power electronics, installation, and maintenance can result in a high levelized cost of energy (LCOE). This makes it difficult for small wind turbines to gain a foothold in the distributed energy revolution currently being led by solar power. Sites with high average wind speeds generally allow lower LCOE, but the vast majority of Americans live and work within more moderate-wind-speed areas, so small turbines should be cost effective to buy and use within such areas. Sonsight Wind's 3.5-kW horizontal-axis wind turbine (HAWT) is being developed to address these challenges.

CIP↗

Photovoltaic Deployment Scenarios toward Global Decarbonization: Role of Disruptive Technologies

To totally decarbonize global electrical systems using photovoltaics (PVs) in the 2050–2060 decade, the world would need to install 63.4 TW of PV. This article models and explores how a PV manufacturing ramp‐up trajectory toward this goal can be achieved while assuming that investors continue to make financially rational decisions avoiding stranded production assets and therefore protecting their return on investment. The model effectively exploits experience curve benefits in both the scaling of the manufacturing process and continued progress in product design technologies. The scale‐up challenge is amplified because trajectories that achieve this goal require an unprecedented ramp‐up of production capacity over just two decades, followed by relatively modest demand to maintain the installed base and support continued population growth. It is demonstrated that sustainable ramp‐up of manufacturing is indeed possible and shown that the deployment of the requisite manufacturing capacity can be accelerated and accomplished at lower total capital cost by the introduction of disruptive technologies that have lower capital intensity, embedded energy, or higher efficiency.

14 SOLAR ENERGY↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Tribal Renewable Energy: Bishop Paiute Tribe, Residential Solar Program Phase II (Final Report)

The project consisted of the design, installation, inspection, and interconnection of 35 grid-tied, solar electric systems, totaled 123 kW rated capacity, on qualified existing low-income single-family homes located within the Bishop Paiute Reservation, which provide at least 65-79% savings in displaced electricity. Tribal job trainees were hired for each installation, gaining valuable job experience. Additionally, each homeowner was educated on energy efficiency and renewable energy. The overall project goal was to deploy clean energy systems in order to achieve the Bishop Paiute Tribe’s long-term goals of energy self-sufficiency, environmental protection, and better lives for our Tribal members and community. The energy displaced was 82.4 percent of total electricity used (exceeding estimated 65-79%)or over 170,000 kWh/year generating approximately $1.29 million worth of power for low-income families over their lifespans, while eliminating an estimated 2,640 tons of greenhouse gas emissions. This reduction makes a significant difference on the reservation giving more families money to spend on other essential items, while reducing their carbon footprint in this beautiful mountain community. Also, implementing these 35 systems provided a approximately 132 hours of paid solar installation work for tribal members. Training and good paying jobs are scarce on the reservation and solar is the fastest growing industry in CA and this training offered our members a real chance to learn and then get paid. The program is very significant to the family who qualified, as most families fall below the federal poverty guidelines, and many are living paycheck to paycheck. Overall, the triple impact of the Bishop Paiute Tribe Residential Solar Program Phase II— affordable energy for low-income families, on-site clean energy production, and hands-on solar installation jobs for local workers—these all help build the Tribe’s energy, economic, environmental, and social self-sufficiency and sovereignty amongst the most needy on the Reservation

14 SOLAR ENERGY↗

City-Wide Distributed Roof-Top Photovoltaic System Adoption Forecast, Grid Impact Simulation, & Neighborhood Microgrid Contribution Assessment

The adoption of distributed photovoltaic (PV) systems grew significantly in recent years. Market projections anticipate future growth for both residential and commercial installations. To understand grid impacts associated with distributed PV, useful hosting capacity studies require accurate representations of the spatial distribution of PV adoptions. Prediction of PV locations and numbers depends on median income data, building use zoning maps, and permit records to understand existing trends and predict future adoption rates and locations throughout an entire city. Using the PV adoption data, advanced and realistic simulations were performed to capture the distributed PV impacts on the grid. Also, using graph theory community detection hundreds of neighborhood microgrids can be discovered for the entire city by identifying densely connected loads that are sparsely connected to other communities. Then, based on the PV adoption predictions, this work identified the contribution of PV within each of the newly discovered graph theory defined microgrid communities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Resilience Planning for Networked Microgrids: A Case Study of Puerto Rico

Microgrids can be designed to enhance the energy resilience of communities and critical infrastructures, such as hospitals, data centers, and communication networks, which are vulnerable to frequent weather-related disruption. Coordinating multiple microgrids in a network can leverage the geographical diversity of load and generation resources while enabling resilient and cost-effective planning of the distribution system. Designing a networked microgrid is complex, involving intricate technical assessment, cost-benefit analysis, site-specific requirements, and the evaluation of existing resources. Therefore, this paper proposes a hierarchical resilience planning framework and performs an extensive techno-economic analysis for the design of a networked microgrid. Hierarchical resilience planning involves technology sizing at an individual community level to meet the critical load and satisfy resilience criteria, and resource optimization at networked microgrid level to provide a higher level of resilience and energy adequacy. A real-world case of Puerto Rico's cooperative microgrid “Microrred de la Montaña” is investigated considering localized electricity tariffs, site-specific demand profiles, solar generation, and existing hydro resources. Multiple optimization scenarios are developed based on the resiliency requirement to estimate the capacity of solar photovoltaic and battery energy storage (BES) to be installed at each substation. The results provide the optimal sizing for individual community and networked microgrid to withstand 1day and 3-day outages along with the criteria for critical load.

13 - HYDRO ENERGY↗

STS-109 Flight Day 5 Highlights

On the fifth day of the STS-109 mission, the crewmembers and Commander Scott Altman of the Columbia Orbiter are shown in their servicing mission to the Hubble Space Telescope (HST). Selected footage is presented of the extravehicular activities (EVA) of Mission Specialists Jim Newman and Mike Massimino, who installed a new port solar array on the HST. Information is presented on the size and power capacity of the array. The reaction wheel assembly, one of four gyroscopic devices used to maneuver the HST, is also shown being replaced by the astronauts. A new insulation blanket panel was also installed at the end of the spacewalk because the astronauts had extra time.

Source record↗

Experimental Evaluation of Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery

A geothermal heat pump (GHP) system is an energy-efficient building heating and cooling technology with great potential for reducing energy consumption and decarbonization. However, applications of GHP are still limited due to the high cost, of which 30% is related to the cost of installing the conventional vertical bore ground heat exchangers, which are usually installed in boreholes 60 meters deep. A dual-purpose underground thermal battery (DPUTB) has been developed to offer a low-cost ground heat exchanger with a built-in thermal storage capacity. The DPUTB innovatively integrates a shallow-bore ground heat exchanger (the outer tank), which can be installed in a borehole less than 6 m deep, with thermal energy storage (TES) (the inner tank). DPUTB has the potential to reduce the cost of a ground source heat pump system while allowing shifting the electric demand of the building served by the GHP system from peak to off-peak hours of the electric grid by charging and discharging the thermal storage. A lab-scale (1:125 in volume) DPUTB prototype was built. Phase change material (PCM) was added to increase the thermal storage capacity and maintain the supply water temperature from the TES within the desired range for direct cooling operation during the discharge period. As PCMs are critical to the TES performance of the DPUTB, this study compared the influence of different PCMs (including salt hydrate and organic PCMs) on the discharge performance of the DPUTB. The thermal State of Charge (SoC) of the DPUTB was used to compare the performance resulting from using different PCMs. Test results indicate that the organic PCM (Methyl Laurate) outperforms salt-hydrate PCMs due to a lower melting temperature and a narrower melting temperature range during the phase change process. The results of this study provide a guide for PCM selection and the optimal design of DPUTB.

Wang, Lingshi↗

Effect of casing treatment on performance of a multistage compressor

AJ85-GE-13 engine was equipped with a compressor case which allowed changes to the case wall over the rotor tips of six of its stages. The engine was tested with four inlet configurations: undistorted and with 180 deg circumferential, hub radial, and tip radial distortions. Baseline data defining compressor performance and stall regions were taken for these inlet configurations with solid (untreated) compressor case inserts. Circumferentially grooved inserts were installed in the first three and last three stages, and the compressor was mapped under similar conditions. The compressor was mapped a third time with untreated inserts in the first three stages and inserts having slots conforming to blade angles in the last three stages. In most cases, the stall pressure ratio was the same as or lower than the baseline. Pumping capacity with the slotted inserts was reduced. Overall compressor efficiency with the grooved rings installed did not appreciably differ from the baseline, but it was 1 to 2 percentage points lower than the baseline with the slotted rings in place. Average stage characteristics for the undistorted inlet case showed little or no sensitivity to casing treatment.

Wenzel, L. M.↗

Analyze Landscape of Solar Panel Installations and Retirements - Solar Prize Round 7 (CRADA CRD-24-30364 Final Report)

By projecting the solar capacity until 2050 at a granular, census tract level, we aim to define Participant's Total Addressable Market for Electra's registration service and examine the volumes and locations of panels reaching end-of-life with corresponding state policies and planned recycling locales. This dual-faceted data will be pivotal in developing a sustainable, per-watt pricing strategy for our state central funds and key areas for collection hubs, ensuring these volumes can adequately support our collection, hauling, and recycling provider network.

14 SOLAR ENERGY↗

Hydrogen Production Cost from Proton-Conducting Solid Oxide Electrolysis

Rigorous stakeholder-vetted techno-economic analysis (TEA) was conducted to estimate the cost of hydrogen (H 2 ) production using Proton-Conducting Solid Oxide (PSO) electrolysis. The analysis evaluates Current (2025) and Future (2035) technology cases at centralized plant scales of 50 and 500 metric tonnes per day (MTD), assuming electricity, water, and air as the only system inputs. Untaxed, unsubsidized levelized cost of hydrogen (LCOH) is projected to range from 2020 $\$$1.81 to $\$$2.47/kg H 2 at an electricity price of $\$$0.03/kWh and 97% capacity factor under Nth-of-a-kind (NOAK) deployment assumptions. Total installed capital cost was developed using bottom-up Design for Manufacture and Assembly (DFMA) stack cost modeling and detailed balance-of-plant estimates, including mechanical and electrical subsystems, installation, site preparation, engineering, and contingency. Stack performance assumptions include thermoneutral operation, degradation over time, and periodic replacement. LCOH was calculated using the Hydrogen Analysis (H2A) discounted cash flow model in constant 2020 dollars. Results indicate PSO electrolysis has potential for competitive hydrogen production costs under low-cost electricity and mature manufacturing conditions.

08 HYDROGEN↗

Contextualizing Wind Turbine Blade Waste: Comparison to Other Global Waste Streams

Worldwide wind energy generation capacity has grown rapidly over the past several decades, and wind turbines installed at the beginning of this wave of growth are approaching the end of their design lifetimes. As an increasing number of wind power plants reach their end of life, both decommissioning and repowering (i.e., dismantling or refurbishing existing turbines and commissioning new ones) will produce waste material from the retired wind turbines, foundations, and balance of plant. However, the amount and type of waste, particularly for wind blades, is often mischaracterized. Although wind turbine components are largely recyclable, the blades are typically made of fiberglass composites, which can present challenges for material recovery and reuse. Within the USA, the accumulation of wind turbine blades in landfills has raised questions about whether the continued expansion of wind energy is sustainable if it results in substantial future waste. This study compares the mass and volume of potential global wind blade waste to other waste streams. It also discusses the materials used to manufacture wind turbine blades and summarizes current options for material redesign, recycling (recovery and reuse), repurposing, and disposal of used blades. The analysis indicates that, although wind turbine blades could represent 14% of the composite market by 2027, the potential future mass and volume of wind turbine blade waste is relatively small compared to other industries. These findings suggest that although the development of scalable, economically viable, and environmentally sustainable methods for wind turbine manufacturing, repurposing, and recycling is important, it may make sense to take advantage of synergies among multiple industries in recycling composite waste, rather than focusing solely on wind turbine blades. From a global perspective, larger sustainability, recycling, and waste stream reduction impacts can be made in other industries, such as transportation and construction.

17 WIND ENERGY↗

California's geothermal resource potential

According to a U.S. Geological Survey estimate, recoverable hydrothermal energy in California may amount to 19,000 MW of electric power for a 30-year period. At present, a geothermal installation in the Geysers region of the state provides 502 MWe of capacity; an additional 1500 MWe of electric generating capacity is scheduled to be in operation in geothermal fields by 1985. In addition to hydrothermal energy sources, hot-igneous and conduction-dominated resources are under investigation for possible development. Land-use conflicts, environmental concerns and lack of risk capital may limit this development.

Leibowitz, L. P.↗

Design and Test of Advanced Thermal Simulators for an Alkali Metal-Cooled Reactor Simulator

The Early Flight Fission Test Facility (EFF-TF) at NASA Marshall Space Flight Center (MSFC) has as one of its primary missions the development and testing of fission reactor simulators for space applications. A key component in these simulated reactors is the thermal simulator, designed to closely mimic the form and function of a nuclear fuel pin using electric heating. Continuing effort has been made to design simple, robust, inexpensive thermal simulators that closely match the steady-state and transient performance of a nuclear fuel pin. A series of these simulators have been designed, developed, fabricated and tested individually and in a number of simulated reactor systems at the EFF-TF. The purpose of the thermal simulators developed under the Fission Surface Power (FSP) task is to ensure that non-nuclear testing can be performed at sufficiently high fidelity to allow a cost-effective qualification and acceptance strategy to be used. Prototype thermal simulator design is founded on the baseline Fission Surface Power reactor design. Recent efforts have been focused on the design, fabrication and test of a prototype thermal simulator appropriate for use in the Technology Demonstration Unit (TDU). While designing the thermal simulators described in this paper, effort were made to improve the axial power profile matching of the thermal simulators. Simultaneously, a search was conducted for graphite materials with higher resistivities than had been employed in the past. The combination of these two efforts resulted in the creation of thermal simulators with power capacities of 2300-3300 W per unit. Six of these elements were installed in a simulated core and tested in the alkali metal-cooled Fission Surface Power Primary Test Circuit (FSP-PTC) at a variety of liquid metal flow rates and temperatures. This paper documents the design of the thermal simulators, test program, and test results.

Garber, Anne E.↗

Repurposing of the Run 2 CMS High Level Trigger Infrastructure as a Cloud Resource for Offline Computing

The former CMS Run 2 High Level Trigger (HLT) farm is one of the largest contributors to CMS compute resources, providing about 25k job slots for offline computing. This CPU farm was initially employed as an opportunistic resource, exploited during inter-fill periods, in the LHC Run 2. Since then, it has become a nearly transparent extension of the CMS capacity at CERN, being located on-site at the LHC interaction point 5 (P5), where the CMS detector is installed. This resource has been configured to support the execution of critical CMS tasks, such as prompt detector data reconstruction. It can therefore be used in combination with the dedicated Tier 0 capacity at CERN, in order to process and absorb peaks in the stream of data coming from the CMS detector. The initial configuration for this resource, based on statically configured VMs, provided the required level of functionality. However, regular operations of this cluster revealed certain limitations compared to the resource provisioning and use model employed in the case of WLCG sites. A new configuration, based on a vacuum-like model, has been implemented for this resource in order to solve the detected shortcomings. This paper reports about this redeployment work on the permanent cloud for an enhanced support to CMS offline computing, comparing the former and new models’ respective functionalities, along with the commissioning effort for the new setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of slotted casing treatment on performance of a multistage compressor

A J85-13 engine was equipped with a compressor case that allowed changes to the case wall over the rotor tips of six of its eight stages. The engine was tested with four inlet configurations: uniform inlet flow, 180 degree circumferential distortion, hub radial distortion, and tip radial distortion. Slotted inserts were installed in the first three stages, and the compressor was mapped under similar conditions. Overall compressor performance obtained with tip treatment was inferior to the performance for the compressor's normal operating range. Pumping capacity with the slotted inserts was reduced. Overall compressor efficiency was reduced 1 to 2 percent with the slotted rings installed for 90 and 100 percent corrected engine speeds.

Moss, J. E., Jr.↗