Seismic monitoring of CO 2 geosequestration using multi-well 4D DAS VSP: Stage 3 of the CO2CRC Otway project
An important part of any CO 2 geosequestration project is to ensure CO 2 containment and conformance in the subsurface. This is generally done by implementing a comprehensive, risk-based Measurement, Monitoring and Verification plan, a key element of which is active time-lapse seismic monitoring. However, high cost and environmental impact of the standard surface seismic monitoring dictate the need for a cost-effective and environmentally friendly alternative. An opportunity to develop such method emerges with advances in distributed acoustic sensing (DAS) technology, which turns an optical fibre into a seismic sensor with dense spatial sampling. DAS can be permanently deployed in multiple wells across the geosequestration site providing a robust and non-intrusive network of seismic receivers. This approach was developed and tested in the CO2CRC Otway project, where injection of 15 kt of CO 2 at 1.5 km depth was monitored with a 4D vertical seismic profiling (VSP) using five borehole DAS arrays and mobile vibroseis sources. The 4D DAS VSP in each of the five wells provides broadly consistent images of the CO 2 plume with some differences due to different illumination of the target horizon, lateral variation of velocities, and seismic anisotropy. When the newly injected CO 2 reaches a CO 2 plume created as a result of an earlier injection into the same formation ~600 m updip, 4D DAS VSP shows a change in reflectivity in that area and beyond. Furthermore, this shows a potential of 4D DAS VSP for monitoring gas injection into gas-saturated reservoirs.