Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “index reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

201 records · Page 12

Changes in Oculomotor Behavior and PVT Reaction Time During One Night of Sleep Deprivation

INTRODUCTION: The Psychomotor Vigilance Test (PVT) is a widely used objective measure of sustained attention, alertness, and fatigue. Previous studies consistently show that prolonged wakefulness and disrupted sleep patterns lead to increased lapses of attention and slower reaction times. These findings have critical implications for various professions, including healthcare, aviation, transportation safety, and spaceflight. In this study, we employed linear mixed models (LMM) to investigate hourly-measured 5-minute PVT reaction times during one night of total sleep deprivation. Our goal was to characterize the contribution of homeostatic sleep pressure (time awake) and circadian phase (salivary melatonin levels) on the dynamics of PVT reaction time. MATERIALS & METHODS: Data from twelve human participants were used in the analysis. Participants were healthy non-smokers, aged 18 and 40, with normal sleep habits defined as Pittsburg Sleep Quality Index scores < 5, and Morningness – Eveningness Questionnaire scores > 42 and < 58, respectively. Participants followed a constant-routine protocol and arrived at the NASA sleep laboratory approximately 1 to 2 hours after their habitual waking time. Tympanic temperature was measured every 30 min to provide a real-time estimate of circadian phase. Participants were required to stay awake throughout the laboratory experiment, which continued until their tympanic temperature had returned to baseline levels. This approach ensured that we could capture each participant's circadian trough and recovery, typically occurring between 24 and 26 hours after waking. The PVT and saliva melatonin were measured every hour, starting approximately from 3 hours after awakening. More information about the measurement protocol can be found in the publication by Stone et al. We used PVT reaction times between 100 and 10000 ms to calculate Reciprocal Reaction Times (RRTs). LMM models were employed to assess the contribution of time awake and saliva melatonin levels on changes in RRTs. Two models were created: the first model treated time awake as a fixed effect and the second model considered both the salivary melatonin level and time awake as fixed effects. Participants were included as a random effect in both models. We compared the models using an Analysis of Variance (ANOVA). The models were computed using the 'lmer' function from the 'lme4' package in R, and LMM p-values were determined using Satterthwaite's method. RESULTS: We found that time awake had a statistically significant effect on PVT RRTs during one night of sleep deprivation [χ2 = 2132.4, df = 1, p < 0.001]. In addition, the model including both saliva melatonin levels and time awake was statistically significantly better than one that uses just time awake [χ2 = 17.4, df = 1, p < 0.001]. DISCUSSION & CONCLUSION: As expected, these preliminary results suggest that the time awake and circadian phase each contribute to performance reductions as measured by the PVT. Future analyses will explore the contributions of other factors to the model.

sleep deprivation↗

Application of Satellite and Ground-based Data to Investigate the UV Radiative Effects of Australian Aerosols

An understanding of the effect of aerosols on biologically- and photochemically-active UV radiation reaching the Earth's surface is important for many ongoing climate, biophysical, and air pollution studies. In particular, estimates of the UV characteristics of the most common Australian aerosols will be valuable inputs to UV Index forecasts, air quality studies, and assessments of the impact of regional environmental changes. By analyzing climatological distributions of Australian aerosols we have identified sites where co-located ground-based UV-B and ozone measurements were available during episodes of relatively high aerosol activity. Since at least June 2003, surface UV global irradiance spectra (285-450 nm) have been measured routinely at Darwin and Alice Springs in Australia by the Australian Bureau of Meteorology (BoM). Using colocated sunphotometer measurements at Darwin and Alice Springs, we identified several episodes of relatively high aerosol activity. Aerosol air mass types were analyzed from sunphotometer-derived angstrom parameter, MODIS fire maps and MISR aerosol property retrievals. To assess aerosol effects we compared the measured UV irradiances for aerosol-loaded and clear-sky conditions with each other and with irradiances simulated using the libRadtran radiative transfer model for aerosol-free conditions. We found that for otherwise similar atmospheric conditions, smoke aerosols over Darwin reduced the surface UV irradiance by as much as 40-50% at 290-300 nm and 20-25% at 320-400 nm near active fires (aerosol optical depth, AOD, at 500 nm approximately equal to 0.6). Downwind of fires, the smoke aerosols over Darwin reduced the surface irradiance by 15-25% at 290-300 nm and approximately 10% at 320-350 nm (AOD at 500 nm approximately equal to 0.2). The effect of smoke increased with decrease of wavel strongest in the UV-B. The aerosol attenuation factors calculated for the selected cases suggest smoke over Darwin has an effect on surface 340-380 nm irradiances that is comparable to that produced by smoke over Sub-Saharan Africa. Dust activity was very low at Alice Springs during 2004, therefore we were not able to identify strong dust events to fully assess the UVeffect of dust. For the cases studied, smoke aerosols seem to produce a stronger reduction in surface UV irradiances than dust aerosols.

UV surface irradiances↗

Sensor Calibration Impacts on Dust Detection Based On MODIS And VIIRS Thermal Emissive Bands

Dust detection using remotely sensed measurements has been one of the challenging problems encountered by atmospheric scientists. MODerate Resolution Imaging Spectroradiometer (MODIS) on the Terra (T)and Aqua (A) platforms have been a versatile sensor for well over 21 and 18 years respectively and have been extremely useful in the retrieval of aerosol information over the entire globe. The MODIS radiances from the Level1B in general are expected to be within 5% accuracy in the reflective wavelengths and within 1% in the thermal emissive wavelengths. In this paper, we evaluate the sensitivity of previously developed dust detection technique based on thermal emissive wavelengths, which correspond to MODIS bands 20, 29, 31, and 32 respectively. The Thermal Emissive Dust Index (TEDI) performed very comparably to the traditional Aerosol Optical Thickness (AOT) retrievals by MODIS reflective channels. Since the MODIS Thermal Emissive Bands (TEB) are well calibrated on-orbit using a BlackBody (BB) source, the calibration of these long wave infrared bands is quite robust. As A-MODIS continues to perform well beyond its designed lifetime of 6 years, the instrument has undergone various levels of degradation during its mission time. As a consequence, it is imperative to check the impacts of calibration on the higher-level retrievals. In this paper, we rigorously analyze the sensitivity of TEDI due to the impact of calibration by the afore-mentioned TEB. The perturbation of the dominant (linear) calibration term demonstrated the following: first, there was a correlation in the sensitivity of the TEDI due to the uncertainty in the linear calibration term. Based on a perturbation in the linear calibration term for all aforementioned bands over a range of ± 5 % yielded the TEDI sensitivity to vary from approximately -3.2 % to about -3.6 %. When considering the uncertainty in each individual band significant changes were observed. The least change was observed for the perturbation in the calibration of band 20 with the TEDI sensitivity and the largest sensitivity in TEDI was observed in the perturbation of band 31 calibration. Thus, in the case of TEDI, noticeable sensitivity due to calibration uncertainty was observed in bands 29, 31, and 32, reiterating the importance of the TEB calibration in these bands. Also, the dust detection scheme based on A-MODIS was successfully transferred to the follow-on sensors such as Suomi (SNPP) and NOAA 20 (N20) VIIRS. The results presented in this paper would be extremely helpful in understanding impacts of calibration on the higher-level products for both current and future missions based on the MODIS heritage. Finally, the work also identifies the importance of radiometric fidelity in maintaining the accuracy of the dust detection. Results presented will show drastic improvement of the Saharan dust detection after the reduction of the electronic crosstalk in the 8.5 μm channel of T-MODIS.

Sriharsha Madhavan↗