Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Planetary Defense System For Responsive Space Missions

As King et al succinctly write, “Collision between the Earth and small objects in the solar system are known to occur regularly, and can result in extinction-level events at their most energetic or more commonly widespread loss of life or economic destruction even for relatively low-energy impacts.” Currently, the JPL Sentry System and the NASA NEO Surveyor mission track, identify, and monitor potential asteroid threats. The JPL Sentry System4 is an automated collision monitoring system which scans the current asteroid catalog for potential impact trajectories with Earth. A 2017 study led by P. Tricarico titled “The near-Earth asteroid population from two decades of observations” analyzes the combined observations of nine leading asteroid surveys. The NASA NEO Surveyor mission seeks to identify 90% of near-Earth objects (NEO) with diameters greater than 140 meters (460 feet) within 10 years. The NEO Surveyor combines data from two infrared imaging detectors to measure NEO size, composition, shape, rotational state, and orbits. Recently, the NASA Double Asteroid Redirection Test (DART) mission successfully altered the orbit of asteroid moon Dimorphos in 2022. This demonstrated that orbit alteration is possible. Thus, collisions between the Earth and asteroids are both likely and demonstrate potential for great harm. There is ongoing work to identify, catalog, and track potential threats. However, when a threat is identified there is not yet a system in place to target the threatening asteroid and defend the planet from potentially existential threats. Building on the DART Mission, we explore a planetary defense system to mitigate asteroid threats.

42 ENGINEERING↗

Rocket instrument for far-UV spectrophotometry of faint astronomical objects

A sensitive sounding rocket instrument for moderate (about 10-A) resolution far-UV (1160-1750-A) spectrophotometry of faint astronomical objects has been developed. The instrument employes a photon-counting microchannel plate imaging detector and a concave grating spectrograph behind a 40-cm Dall-Kirkham telescope. A unique remote-control pointing system, incorporating an SIT vidicon aspect camera, two star trackers, and a tone-encoded command telemetry link, permits the telescope to be oriented to within 5 arc sec of any target for which suitable guide stars can be found. The design, construction, calibration, and flight performance of the instrument are discussed.

Hartig, G. F.↗

CCD camera systems and support electronics for a White Light Coronagraph and X-ray XUV solar telescope

Two instruments, a White Light Coronagraph and an X-ray XUV telescope built into the same housing, share several electronic functions. Each instrument uses a CCD as an imaging detector, but due to different spectral requirements, each uses a different type. Hardware reduction, required by the stringent weight and volume allocations of the interplanetary mission, is made possible by the use of a microprocessor. Most instrument functions are software controlled with the end use circuits treated as peripherals to the microprocessor. The instruments are being developed for the International Solar Polar Mission.

Harrison, D. C.↗

A quadratic analog-to-digital converter

An analog-to-digital converter with a square root transfer function has been developed for use with a pair of CCD imaging detectors in the White Light Coronagraph/X-ray XUV Telescope experiment to be flown as part of the Internal Solar Polar Mission. It is shown that in background-noise-limited instrumentation systems a quadratic analog-to-digital converter will allow a maximum dynamic range with a fixed number of data bits. Low power dissipation, moderately fast conversion time, and reliability are achieved in the proposed design using standard components and avoiding nonlinear elements.

Harrison, D. C.↗

Einstein observations of the X-ray structure of Centaurus A - Evidence for the radio-lobe energy source

The X-ray source at the center of the radio galaxy Centaurus A has been resolved into the following components with the imaging detectors on board the Einstein X-ray Observatory: (1) a point source coincident with the infrared nucleus; (2) diffuse X-ray emission coinciding with the inner radio lobes; (3) a 4-arcmin extended region of emission about the nucleus; and (4) an X-ray jet between the nucleus and the NE inner radio lobe. The 2 x 10 to the 39th ergs/s detected from the radio lobes probably arises from inverse Compton scattering of the microwave background. The average magnetic field in the SW lobe is determined to be not less than 4 microgauss. The extended region may be due to emission by a cloud of hot gas, cosmic-ray scattering, or stellar sources. The jet provides strong evidence for the continuous resupply of energy to the lobes from the nucleus.

Schreier, E. J.↗

X-rays from Eta Carinae and the surrounding nebula

Two X-ray pictures have been obtained of the Eta Car nebula using the imaging detectors of the Einstein Observatory. One covers a field 1-deg square with a resolution of 1 arcmin; the second covers a field 25 arcmin in diameter with resolution of a few arcsec. These show a region of diffuse X-ray emission with luminosity 10 to the 35th ergs/s. The sources have been positively identified as the peculiar object Eta Car, a Wolf-Rayet star, a cluster of O stars, and five individual O stars. The Eta Car X-ray source is extended and coincides with the outer shell of the diffuse object Eta Car itself. One X-ray bright spot may be emission from a central object within Eta Car.

Seward, F. D.↗

The Einstein Observatory - New perspectives in astronomy

The impact of high-resolution, high-sensitivity X-ray measurements obtained by the Einstein Observatory (HEAO-2) on various areas of astronomical research is discussed. Following a review of the Einstein instruments based on grazing incidence focusing X-ray optics, including the telescope, imaging detectors and spectrometers, consideration is given to observations of X-ray emission from stellar systems, galaxies, and clusters of galaxies. Einstein results concerning the X-ray luminosities of young O, B and A stars and late K and M stars, the temperature, composition and distribution of material ejected in supernova explosions and comprising the interstellar medium, the formation and evolution of stellar systems and galaxies, the energy source of quasars and active galactic nuclei and the mass distribution in galactic clusters are indicated. Substantial progress made possible by the high-resolution observations of the diffuse X-ray background in cosmological research is also noted.

Giacconi, R.↗

Neutron star binaries, pulsars and burst sources

Unresolved issues involving neutron star binaries, pulsars, and burst sources are described. Attention is drawn to the types of observations most likely to resolve them. Many of these observations are likely to be carried out during the next decade by one or more missions that have been approved or proposed. Flux measurements with an imaging detector and broad-band spectroscopic studies in the energy range 30-150 keV are discussed. The need for soft X-ray and X-ray observations with an instrument which has arcminute angular resolution and an effective area substantially greater than of ROSAT or EXOSAT is also discussed.

Lamb, F. K.↗

The X-ray structure of Centaurus A

The Einstein X-ray observatory imaging detectors have found X-ray emission associated with several components of the nearby radio galaxy Cen A = NGC 5128: (1) the compact nucleus; (2) an X-ray jet pointed toward the NE radio lobes; (3) the middle NE radio lobe; (4) the disk or dust lane; and (5) diffuse emission extending several arcmin around the nucleus. The intensity of the nucleus changed by a factor of seven over six months. The X-ray jet is considered in terms of thermal, inverse Compton, and synchrotron models. The emission of the NE radio lobe is greater than that expected from inverse Compton or synchrotron processes. Two ridges of emission are found along each edge of the dust lane, within several arcmin of the nucleus. The diffuse X-ray component has a luminosity which is too high to be due to bulge population X-ray sources, but which may be produced by main sequence stars under appropriate circumstances.

Feigelson, E. D.↗

The detection of X rays from Jupiter

X rays in the energy band 0.2-3.0 keV have been detected coming from both polar regions of Jupiter. The observations were made in 1979 and 1981 by using the imaging proportional counter and high resolution imaging detectors on the Einstein X-ray astronomy satellite. The measured flux density of approximately 0.0006/sq cm-sec at earth corresponds to an X ray luminosity of approximately 4 x 10 to the 9th W in the 0.2- to 3.0-keV energy band. The energy spectrum of the X rays is extremely soft and can be characterized by a power law with an exponent of approximately 2.3. Detector energy resolution is insufficient to distinguish a soft line spectrum from a continuum. However, the shape of the response and the observed X ray power indicate that the source of this auroral emission is not electron bremsstrahlung as on the earth, but is most probably line emission from O and S ions with energies between 0.03 and 4.0 MeV/nucleon precipitating from the outer boundary of the Io plasma torus at L approximately 8.

Metzger, A. E.↗

The X-ray lobes of SS 433

Einstein Observatory imaging detector observations of SS 433 and its surrounding region are used to map an approximately 2 x 1-deg region containing W50 centered on SS 433, which exhibits two bright, diffuse lobes of X-ray emission symmetrically displaced east and west of SS 433 and aligned along the long axis of W50. The bulk of the emission from each lobe is confined to a region subtending an angle of about 30 deg at the central object. X-ray spectra indicate that the diffuse emission is considerably softer than SS 433 itself. The kinematic beam model for SS 433 is taken as the basis for a discussion of the properties and origins of the lobes and of their relationship to W50.

Watson, M. G.↗

Quantum efficiency measurements for several waveshifter coatings in the extreme vacuum ultraviolet

Quantum efficiency measurements are given for coronene and liumogen coatings designed to enhance UV sensitivity for silicon charge coupled device imaging detectors. Coatings on quartz and on UDT PIN 10DP photodiodes were tested. The wavelength range extended from 153.7 to 50.0 nm in the vacuum ultraviolet. Similar measurements were made for coronene, liumogen, and stilbene-3 laser dye films on quartz disks relative to sodium salicylate. Sodium salicylate and coronene are the most efficient waveshifters down to 50 nm so far observed. Coronene's fairly constant quantum efficiency over such a wide wavelength range into the far VUV makes it a useful waveshifter for UV and VUV applications.

Butner, C. L.↗

Microprocessor-controlled laser tracker for atmospheric sensing

An optical tracking system comprising a visible HeNe laser, an imaging detector, and a microprocessor-controlled mirror, has been designed to track a moving retroreflector located up to 500 m away from an atmospheric instrument and simultaneously direct spectrally tunable infrared laser radiation to the retroreflector for double-ended, long-path absorption measurements of atmospheric species. The tracker has been tested during the recent flight of a balloon-borne tunable diode laser absorption spectrometer which monitors the concentrations of stratospheric species within a volume defined by a 0.14-m-diameter retroreflector lowered 500 m below the instrument gondola.

Johnson, R. A.↗

Lightweight Video-Camera Head

Compact, lightweight video camera head constructed by remounting lens and charge-coupled-device image detector from small commercial video camera in separate assembly. Useful in robotics, artificial vision, and vision guidance systems. Designed to be mounted on visor of helmet to monitor motions of eyes in experiments on vestibulo-ocular reflexes.

Proctor, David R.↗

Imaging spectroscopy II; Proceedings of the Meeting, San Diego, CA, Aug. 20, 21, 1987

The conference presents papers on airborne imaging spectrometers, imaging spectrometry analysis, and spaceborne imaging spectrometers. Consideration is given to an imaging spectrometer for ocean and land remote sensing, an advanced solid-state array spectroradiometer, airborne visible/infrared imaging spectrometer design and performance, and a signal chain for the airborne visible/infrared imaging spectrometer. Other topics include imaging spectrometry as a tool for botanical mapping, the estimation of forest canopy characteristics and nitrogen cycling using lasing spectrometry, and a continuous readout photon counting imaging detector.

Vane, Gregg↗

Einstein Observations of Galactic supernova remnants

This paper summarizes the observations of Galactic supernova remnants with the imaging detectors of the Einstein Observatory. X-ray surface brightness contours of 47 remnants are shown together with gray-scale pictures. Count rates for these remnants have been derived and are listed for the HRI, IPC, and MPC detectors.

Seward, Frederick D.↗

Spatial heterodyne spectroscopy - Interferometric performance at any wavelength without scanning

Spatial heterodyne spectroscopy (SHS) employing a two-beam dispersive interferometer producing a Fizeau fringe pattern having wavelength-dependent spatial frequencies is presented. The pattern is recorded on an imaging detector and Fourier transformed to recover the input stream. It is pointed out that spectrometers operating on the SHS principle can achieve the theoretical resolution limit of the gratings without scanning, retaining at the same time the large angular input tolerance and multiplexing properties of conventional scanning Fourier-transform spectrometers. Additionally, broad spectral coverages can be achieved, and field widening can be accomplished without moving parts.

Roesler, F. L.↗