Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image plates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

NAIS: Nuclear activation-based imaging spectroscopy

In recent years, the development of high power laser systems led to focussed intensities of more than 10{sup 22} W/cm{sup 2} at high pulse energies. Furthermore, both, the advanced high power lasers and the development of sophisticated laser particle acceleration mechanisms facilitate the generation of high energetic particle beams at high fluxes. The challenge of imaging detector systems is to acquire the properties of the high flux beam spatially and spectrally resolved. The limitations of most detector systems are saturation effects. These conventional detectors are based on scintillators, semiconductors, or radiation sensitive films. We present a nuclear activation-based imaging spectroscopy method, which is called NAIS, for the characterization of laser accelerated proton beams. The offline detector system is a combination of stacked metal foils and imaging plates (IP). After the irradiation of the stacked foils they become activated by nuclear reactions, emitting gamma decay radiation. In the next step, an autoradiography of the activated foils using IPs and an analysis routine lead to a spectrally and spatially resolved beam profile. In addition, we present an absolute calibration method for IPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A new angle-resolved proton energy spectrometer

In typical laser-driven proton acceleration experiments Thomson parabola proton spectrometers are used to measure the proton spectra with very small acceptance angle in specific directions. Stacks composed of CR-39 nuclear track detectors, imaging plates, or radiochromic films are used to measure the angular distributions of the proton beams, respectively. In this paper, a new proton spectrometer, which can measure the spectra and angular distributions simultaneously, has been designed. Proton acceleration experiments performed on the Xtreme light III laser system demonstrates that the spectrometer can give angle-resolved spectra with a large acceptance angle. This will be conductive to revealing the acceleration mechanisms, optimization, and applications of laser-driven proton beams.

43 PARTICLE ACCELERATORS↗

Monte-Carlo simulation of noise in hard X-ray Transmission Crystal Spectrometers: Identification of contributors to the background noise and shielding optimization

Transmission crystal spectrometers (TCS) are used on many laser facilities to record hard X-ray spectra. During experiments, signal recorded on imaging plates is often degraded by a background noise. Monte-Carlo simulations made with the code GEANT4 show that this background noise is mainly generated by diffusion of MeV electrons and very hard X-rays. An experiment, carried out at LULI2000, confirmed that the use of magnets in front of the diagnostic, that bent the electron trajectories, reduces significantly this background. The new spectrometer SPECTIX (Spectromètre PETAL à Cristal en TransmIssion X), built for the LMJ/PETAL facility, will include this optimized shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a ten inch manipulators-based, flexible, broadband two-crystal spectrometer

We have developed and implemented a broadband X-ray spectrometer with a variable energy range for use at the Atomic Weapons Establishment's Orion Laser. The spectrometer covers an energy bandwidth of ∼1–2 keV using two independently mounted, movable Bragg diffraction crystals. Using combinations of cesium hydrogen pthlate, ammonium dihydrogen phosphate, and pentaerythritol crystals, spectra covering the 1.4–2.5, 1.85–3.15, or 3.55–5.1 keV energy bands have been measured. Image plate is used for detection owing to its high dynamic range. Background signals caused by high energy X-rays and particles commonly produced in high energy laser experiments are reduced by a series of tantalum baffles and filters installed between the source and crystal and also between the crystals and detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigation of hard x-ray background in backlit pinhole imagers

Experiments were performed to mitigate the hard x-ray background commonly observed in backlit pinhole imagers. The material of the scaffold holding the primary backlighter foil was varied to reduce the laser-plasma instabilities responsible for hot electrons and resulting hard x-ray background. Radiographic measurements with image plates showed a factor of >25 decrease in x-rays between 30 and 67 keV when going from a plastic to Al or V scaffold. Here, a potential design using V scaffold offers a signal-to-background ratio of 6:1, a factor of 2 greater than using the bare plastic scaffold.

07 ISOTOPE AND RADIATION SOURCES↗

Measurements of hot-electron temperature in laser-irradiated plasmas

In a recently published work 1–3 we reported on measuring the total energy of hot electrons produced by the interaction of a nanosecond laser with planar CH-coated molybdenum targets, using the Mo K α emission. The temperature of the hot electrons in that work was determined by the high-energy bremsstrahlung [hard x-ray (HXR)] spectrum measured by a three-channel fluorescence-photomultiplier detector (HXRD). In the present work, we replaced the HXRD with a nine-channel image-plate (IP)–based detector (HXIP). For the same conditions (irradiance of the order of 10 14 W/cm 2 ; 2-ns pulses) the measured temperatures are consistently lower than those measured by the HXRD (by a factor ~1.5 to 1.7). In addition, we supplemented this measurement with three experiments that measure the hot-electron temperature using K α line-intensity ratios from high-Z target layers, independent of the HXR emission. These experiments yielded temperatures that were consistent with those measured by the HXIP. We showed that the thermal x-ray radiation must be included in the derivation of total energy in hot electrons (E hot ), and that this makes E hot only weakly dependent on hot-electron temperature. For a given x-ray emission in inertial confinement fusion compression experiments, this result would lead to a higher total energy in hot electrons, but the preheat of the compressed fuel may be lower because of the reduced hot-electron range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration and characterization of a highly efficient spectrometer in von Hamos geometry for 7-10 keV x-rays

Here, we have built an absolutely calibrated, highly efficient, Bragg crystal spectrometer in von Hamos geometry. This zinc von Hamos spectrometer uses a crystal made from highly oriented pyrolytic graphite that is cylindrically bent along the non-dispersive axis. It is tuned to measure x-ray spectra in the 7–10 keV range and has been designed to be used on a Ten Inch Manipulator for the Omega and OmegaEP target chambers at the Laboratory for Laser Energetics in Rochester, USA. Significant shielding strategies and fluorescence mitigation have been implemented in addition to an imaging plate detector making it well suited for experiments in high-intensity environments. Here we present the design and absolute calibration as well as mosaicity and integrated reflectivity measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technique for insulated and non-insulated metal liner X-pinch radiography on a 1 MA pulsed power machine

Broadband, high resolution X-pinch radiography has been demonstrated as a method to view the instability induced small scale structure that develops in near solid density regions of both insulated and non-insulated cylindrical metallic liners. In experiments carried out on a 1-1.2 MA 100-200 ns rise time pulsed power generator, μm scale features were imaged in initially 16 μm thick Al foil cylindrical liners. Better resolution and contrast were obtained using an X-ray sensitive film than with image plate detectors because of the properties of the X-pinch X-ray source. Here, we also discuss configuration variations that were made to the simple cylindrical liner geometry that appeared to maintain validity of the small-scale structure measurements while improving measurement quality.

47 OTHER INSTRUMENTATION↗

X-ray source development for EXAFS measurements on the National Ignition Facility

We present that extended X-ray absorption Fine Structure (EXAFS) measurements require a bright, spectrally smooth, and broad-band x-ray source. In a laser facility, such an x-ray source can be generated by a laser-driven capsule implosion. In order to optimize the x-ray emission, different capsule types and laser irradiations have been tested at the National Ignition Facility (NIF). A crystal spectrometer is used to disperse the x-rays and high efficiency image plate detectors are used to measure the absorption spectra in transmission geometry. Finally, EXAFS measurements at the K-edge of iron at ambient conditions have been obtained for the first time on the NIF laser, and the requirements for optimization have been established.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a 1-2 keV point-projection x-ray spectrometer on the National Ignition Facility

A point-projection soft X-ray Opacity Spectrometer (OpSpec) has been implemented to measure X-ray spectra from ~1 to 2 keV on the National Ignition Facility (NIF). Measurement of such soft X-rays with open-aperture point-projection detectors is challenging because only very thin filters may be used to shield the detector from the hostile environment. OpSpec diffracts X-rays from 540 to 2100 eV off a potassium (or rubidium) acid phthalate (KAP or RbAP) crystal onto either image plates or, most recently, X-ray films. A “sacrificial front filter” strategy is used to prevent crystal damage, while 2 or 3 rear filters protect the data. Since May 2017, OpSpec has been recording X-ray transmission data for iron-magnesium plasmas on the NIF, at “Anchor 1” plasma conditions (temperature ~150 eV, density ~7 × 10 21 e - /cm 3 ). Upgrades improved OpSpec’s performance on 6 NIF shots in August and December 2017, with reduced backgrounds and 100% data return using filter stacks as thin as 2.9 μm (total). We conclude that photometric noise is beginning to meet requirements, and further work will reduce systematic errors.

47 OTHER INSTRUMENTATION↗

X-ray backlighter requirements for refraction-based electron density diagnostics through Talbot-Lau deflectometry

We report that Talbot-Lau x-ray interferometers can map electron density gradients in High Energy Density (HED) samples. In the deflectometer configuration, it can provide refraction, attenuation, elemental composition, and scatter information from a single image. X-ray backlighters in Talbot-Lau deflectometry must meet specific requirements regarding source size and x-ray spectra, amongst others, to accurately diagnose a wide range of HED experiments. 8 keV sources produced in the high-power laser and pulsed power environment were evaluated as x-ray backlighters for Talbot-Lau x-ray deflectometry. In high-power laser experiments, K-shell emission was produced by irradiating copper targets (500 × 500 × 12.5 μm 3 foils, 20 μm diameter wire, and >10 μm diameter spheres) with 30 J, 8-30 ps laser pulses and a 25 μm copper wire with a 60 J, 10 ps laser pulse. In the pulsed power environment, single (2 × 40 μm) and double (4 × 25 μm) copper x-pinches were driven at ~1 kA/ns. Lastly, moiré fringe formation was demonstrated for all x-ray sources explored, and detector performance was evaluated for x-ray films, x-ray CCDs, and imaging plates in context of spatial resolution, x-ray emission, and fringe contrast.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementing time resolved electron temperature capability at the NIF using a streak camera

A new capability on NIF has been implemented to measure the temperature of x-ray emitting sources. Although it is designed primarily for Inertial Confinement Fusion (ICF), it can be used for any hot emitting source that is well modeled. The electron temperature (T e ) of the hot spot within the core of imploded inertial confinement fusion capsules is an effective indicator of implosion performance. Currently, there are spatially and temporally integrated T e inferences using image plates. A temporally resolved measurement of Te will help elucidate the mechanisms for hot spot heating and cooling such as conduction to fuel, alpha-heating, mix and radiative losses. To determine the temporally resolved T e of hot spots, specific filters are added to an existing x-ray streak camera “Streaked Polar Instrumentation for Diagnosing Energetic Radiation (SPIDER)” to probe the emission spectrum during the x-ray burn history of implosions on the National Ignition Facility (NIF). One of the difficulties in inferring the hot spot temperature is the attenuation of the emission due to opacity from the shell and fuel. Therefore, a series of increasingly thick titanium filters were implemented to isolate the emission in specific energy regions that are sensitive to temperatures above 3keV while not significantly influenced by the shell/fuel attenuation. Additionally, a relatively thin zinc filter was used to measure the contribution of colder emission sources. Since the signal levels of the emission through the thicker filters are relatively poor, a dual slit (aperture) was designed to increase detected signal at the higher end of the spectrum. Herein, the design of the filters and slit are described, an overview of the solving technique is provided, and initial electron temperature results are reported.

47 OTHER INSTRUMENTATION↗

X-ray analysis methods for sources from self-modulated laser wakefield acceleration driven by picosecond lasers

A versatile set of methods for analyzing x-ray energy spectra and photon flux has been developed for laser plasma accelerator experiments driven by picosecond lasers. Forward fit provides extrapolated broad energy spectrum measurements, while Ross pair and differential average transmission analysis provide directly measured data points using a particular diagnostic. Combining these methods allows the measurement of x-ray energy spectra with improved confidence. We apply here the methods to three diagnostics (filter wheel, stacked image plate spectrometer, and step wedge), each sensitive to a different region of x-ray energies (<40 keV, 35–100 keV, and 60–1000 keV, respectively), to characterize the analysis methods using laser-driven bremsstrahlung x-rays. We then apply the methods to measure three x-ray mechanisms, betatron, inverse Compton scattering, and bremsstrahlung, driven by a laser plasma accelerator. The analysis results in the measurement of x-ray energy spectra ranging from 10 keV to 1 MeV with peak flux greater than 10 10 photons/keV/Sr. The combined analysis methods provide a robust tool to accurately measure broadband x-ray sources (keV to MeV) driven by laser plasma acceleration with picosecond, kilojoule-class lasers.

47 OTHER INSTRUMENTATION↗

A spherical crystal diffraction imager for Sandia’s Z Pulsed Power Facility

Sandia’s Z Pulsed Power Facility is able to dynamically compress matter to extreme states with exceptional uniformity, duration, and size, which are ideal for investigating fundamental material properties of high energy density conditions. X-ray diffraction (XRD) is a key atomic scale probe since it provides direct observation of the compression and strain of the crystal lattice and is used to detect, identify, and quantify phase transitions. Because of the destructive nature of Z-Dynamic Material Property (DMP) experiments and low signal vs background emission levels of XRD, it is very challenging to detect a diffraction signal close to the Z-DMP load and to recover the data. We have developed a new Spherical Crystal Diffraction Imager (SCDI) diagnostic to relay and image the diffracted x-ray pattern away from the load debris field. The SCDI diagnostic utilizes the Z-Beamlet laser to generate 6.2-keV Mn–He α x rays to probe a shock-compressed material on the Z-DMP load. Finally, a spherically bent crystal composed of highly oriented pyrolytic graphite is used to collect and focus the diffracted x rays into a 1-in. thick tungsten housing, where an image plate is used to record the data.

47 OTHER INSTRUMENTATION↗

High resolution >40 keV x-ray radiography using an edge-on micro-flag backlighter at NIF-ARC

Radiography of low-contrast features in high-density materials evolving on a nanosecond timescale requires a bright photon source in the tens of keV range with high temporal and spatial resolution. One application for sources in this category is the study of dynamic material strength in samples compressed to Mbar pressures at the National Ignition Facility, high-resolution measurements of plastic deformation under conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Here, we present radiographic data and the modulation transfer function (MTF) analysis of a multi-component test object probed at ~100 keV effective backlighter energy using a 5 μm-thin dysprosium foil driven by the NIF Advanced Radiographic Capability (ARC) short-pulse laser (~2 kJ, 10 ps). The thin edge of the foil acts as a bright line-projection source of hard x rays, which images the test object at 13.2× magnification into a filtered and shielded image plate detector stack. The system demonstrates a superior contrast of shallow (5 μm amplitude) sinusoidal ripples on gold samples up to 90 μm thick as well as enhanced spatial and temporal resolution using only a small fraction of the laser energy compared to an existing long-pulse-driven backlighter used routinely at the NIF for dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-driven flash x-ray radiography of a shocked metallic foil

Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.

36 MATERIALS SCIENCE↗