Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

An apparent gravitational lens with an image separation of 2.6 arc min

Observations are reported which confirm Paczynski's 1986 speculation that the previously known (Arp and Hazard, 1980) pair of 19th magnitude quasars 1146+111B,C are actually two images of a single object produced by a gravitational lens. The image split is 157 arcsec, more than 20 times greater than any previously reported, thus indicating an exceptionally massive lensing object. The data supporting the lens hypothesis are remarkably similar, high signal-to-noise, moderate resolution spectra of the two components. Both spectra show strong Mg II 2798-angstrom emission at z = 1.012 plus or minus 0.001 with indistinguishable redshifts (delta v = 126 plus or minus 309 km/s), widths (FWHM = 64 plus or minus 4 angstroms) and detailed profile shapes. Both spectra also show broad troughs at 6180 angstroms and several weaker continuum features. Neither object exhibits the O II 3727-A forbidden line which is frequently strong in Mg II emission objects. If the foreground galaxy clustering apparent in a deep R band charge-coupled device image proves insufficient to explain the large image splitting, other possibilities such as massive dark objects (e.g. a black hole of about 10 to the 15th solar masses) or a cosmic string may be indicated.

Turner, E. L.↗

Development of CMOS Active Pixel Image Sensors for Low Cost Commercial Applications

JPL, under sponsorship from the NASA Office of Advanced Concepts and Technology, has been developing a second-generation solid-state image sensor technology. Charge-coupled devices (CCD) are a well-established first generation image sensor technology. For both commercial and NASA applications, CCDs have numerous shortcomings. In response, the active pixel sensor (APS) technology has been under research. The major advantages of APS technology are the ability to integrate on-chip timing, control, signal-processing and analog-to-digital converter functions, reduced sensitivity to radiation effects, low power operation, and random access readout.

solid-state image sensors active pixel sensor APS ↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

Ionization wave propagation in a He plasma jet in a controlled gas environment

Characterizing ionization wave propagation in low temperature plasma jets is critical to predicting production of reactive species and plasma–surface interactions for biomedical applications and surface functionalization. In this work, results from optical emission and laser induced fluorescence measurements of the ionization wave in a He plasma jet operating in a controlled gas environment are discussed and used for comparison with numerical modeling. Additionally, the ionization wave was observed using ICCD (Intensified Charge Coupled Device) imaging and characterized by time and spatially resolved electron density measurements using laser-collision-induced fluorescence. The plasma jet was initially characterized using pure He (nominally at 200 Torr), while varying pressure and voltage. When operating in pure He, the ionization wave broadly expands exiting the plasma tube. Increasing the operating pressure reduces the speed and isotropic expansion of the ionization wave. Furthermore, the jet operated with a humid He shroud was also studied. The humid He shroud results in the electron density increasing and having an annular profile due to the lower ionization potential of H2O compared to He and localized photoionization in the mixing region. Numerical modeling highlighted the importance of resonance radiation emitted by excited states of He, photoelectron emission from the quartz tube, and the kinetic behavior of the electrons produced by photoionization ahead of the ionization front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined microwave and laser Rayleigh scattering diagnostics for pin-to-pin nanosecond discharges

In this work, the temporal decay of electrons produced by an atmospheric pin-to-pin nanosecond discharge operating in the spark regime was measured via a combination of microwave Rayleigh scattering (MRS) and laser Rayleigh scattering (LRS). Due to the initial energy deposition of the nanosecond pulse, a variation in the local gas density occurs on the timescale of electron decay. Thus, the assumption of a constant collisional frequency is no longer applicable when electron number data are extracted from MRS measurements. Furthermore, to recalibrate MRS measurements throughout the electron decay period, temporally resolved LRS measurements of the local gas density were performed over the event duration. The local gas density was calculated to be 30% of the ambient level during the later stages of electron decay, and it recovers at about 1 ms after discharge. A shock front traveling approximately 500 m/s was additionally observed. Coupled with plasma volume calibration via temporally resolved intensified charge-coupled device imaging, the corrected decay curves of the electron number and electron number density are presented with a measured peak electron number density of 4.5 × 1015 cm -3 and a decay rate of ~(0.1–0.35) × 10 7 s -1 . A hybrid MRS and LRS diagnostic technique can be applied for a broad spectrum of atmospheric-pressure microplasmas where a variation in the gas number density is expected due to energy deposition in the discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion fluxes and memory effects in an Ar–O 2 modulated radiofrequency-driven atmospheric pressure plasma jet

In this work we used molecular beam mass spectrometry to characterize ion fluxes produced by a modulated radiofrequency (RF)-driven atmospheric pressure plasma jet operating in a homogeneous gas environment (Ar + 1% O 2 ). The influence of the RF modulation frequency (100 Hz to 20 kHz) on the ion fluxes was investigated by time-resolved measurements, and the lifetimes of the dominant ions, O 2 + , NO + , O − , O 2 − and O 3 − , were found to be 28 ± 2, 117 ± 8, 7.3 ± 0.4, 17 ± 1 and 23 ± 2 μs, respectively. The absolute ion densities in the near afterglow region were found to be of the order of 1011 cm−3. Significant differences in the dynamics of the positive and negative ions were found; these are explained by the presence of electrons at similar densities in the afterglow produced by electron detachment reactions from negative ions due to the large concentrations of atomic oxygen and singlet delta oxygen. Transitions in ion flux dynamics for different modulation frequencies and at the startup of the plasma were analyzed together with intensified charge coupled device images recording the plasma propagation in order to assess the dynamics of plasma plume propagation and how it is impacted by ‘memory effects’. Quantitative measurements of the ion densities enabling these memory effects are reported. The results in this paper highlight the tremendous impact of memory effects on plasma propagation and the corresponding pre-ionization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First impurity powder injection experiments in LHD

Injection of impurities in the form of sub-millimeter powder grains is performed for the first time in the Large Helical Device (LHD) plasma, employing the Impurity Powder Dropper (IPD) [A. Nagy et al., RSI 2018], developed and built by PPPL. Controlled amounts of boron (B) and boron nitride (BN) powder are injected into the helical plasma. Visible camera imaging, UV and charge exchange spectroscopy measurements show that the injected impurities effectively penetrate into the plasma in two different magnetic configurations.The prompt effects of the impurities on the plasma are characterized as the injection rate is scanned. The injected impurities provide a supplemental electron source, causing the plasma density to increase, together with the radiated power. Beneficial effects on the confined plasma temperature are observed at low plasma densities, due to an increased efficiency in NBI power absorption. For $n_{e,av}<10^{19}m^{-3}$ the powder grains penetrate deeper into the plasma, as they can be less effectively deflected by the plasma flow in the divertor leg, which they have to cross first as they are injected from the top of the machine.In this case, the created B ions are observed to move outwards from UV spectroscopy and charge exchange measurements, due to the outwards direction of the radial electric field. This makes low density plasmas a better candidate for powder boronization techniques.

Boron↗

CALET Search for Electromagnetic Counterparts of Gravitational Waves during the LIGO/Virgo O3 Run

The CALorimetric Electron Telescope (CALET) on the International Space Station consists of a high-energy cosmic-ray CALorimeter (CAL) and a lower-energy CALET Gamma-ray Burst Monitor (CGBM). CAL is sensitive to electrons up to 20 TeV, cosmic-ray nuclei from Z = 1 through Z ~ 40, and gamma rays over the range 1 GeV–10 TeV. CGBM observes gamma rays from 7 keV to 20 MeV. The combined CAL-CGBM instrument has conducted a search for gamma-ray bursts (GRBs) since 2015 October. We report here on the results of a search for X-ray/gamma-ray counterparts to gravitational-wave events reported during the LIGO/Virgo observing run O3. No events have been detected that pass all acceptance criteria. We describe the components, performance, and triggering algorithms of the CGBM—the two Hard X-ray Monitors consisting of LaBr 3 (Ce) scintillators sensitive to 7 keV–1 MeV gamma rays and a Soft Gamma-ray Monitor BGO scintillator sensitive to 40 keV–20 MeV—and the high-energy CAL consisting of a charge detection module, imaging calorimeter, and the fully active total absorption calorimeter. The analysis procedure is described and upper limits to the time-averaged fluxes are presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Lightweight helmet-mounted eye movement measurement system

The helmet-mounted eye movement measuring system, weighs 1,530 grams; the weight of the present aviators' helmet in standard form with the visor is 1,545 grams. The optical head is standard NAC Eye-Mark. This optical head was mounted on a magnesium yoke which in turn was attached to a slide cam mounted on the flight helmet. The slide cam allows one to adjust the eye-to-optics system distance quite easily and to secure it so that the system will remain in calibration. The design of the yoke and slide cam is such that the subject can, in an emergency, move the optical head forward and upward to the stowed and locked position atop the helmet. This feature was necessary for flight safety. The television camera that is used in the system is a solid state General Electric TN-2000 with a charged induced device imager used as the vidicon.

Barnes, J. A.↗

Outer planet investigations using a CCD camera system

Problems related to analog noise, data transfer from the camera buffer to the storage computer, and loss of sensitivity of a two dimensional charge coupled device imaging system are reported. To calibrate the CCD system, calibrated UBV pinhole scans of the Saturn disk were obtained with a photoelectric area scanning photometer. Atmospheric point spread functions were also obtained. The UBV observations and models of the Saturn atmosphere are analyzed.

Price, M. J.↗

The great galactic centre mystery

Gamma-ray observations of the center of the Galaxy show a varying positron-electron annihilation radiation emission, while at radio wavelengths a non-thermal compact source surrounded by ionized gas moving at high velocities can be seen. Line emission maps for atomic and ionized hydrogen and molecular gas suggest gas expulsion and a massive collapsed object. IR observations show that ionized gas in the central few parsecs of the Galactic center is concentrated in at least 14 small clouds. Charge-coupled device images show a pair of faint, very red sources within a few arc seconds of IRS 16 and the compact non-thermal radio source. The positron-electron annihilation line emission implies an annihilation rate of 10 to the 43rd per sec, compared with an observed luminosity at IR wavelengths of 10 to the 40 erg per sec. Some models are briefly discussed.

Riegler, G. R.↗

Quantum efficiency measurements for several waveshifter coatings in the extreme vacuum ultraviolet

Quantum efficiency measurements are given for coronene and liumogen coatings designed to enhance UV sensitivity for silicon charge coupled device imaging detectors. Coatings on quartz and on UDT PIN 10DP photodiodes were tested. The wavelength range extended from 153.7 to 50.0 nm in the vacuum ultraviolet. Similar measurements were made for coronene, liumogen, and stilbene-3 laser dye films on quartz disks relative to sodium salicylate. Sodium salicylate and coronene are the most efficient waveshifters down to 50 nm so far observed. Coronene's fairly constant quantum efficiency over such a wide wavelength range into the far VUV makes it a useful waveshifter for UV and VUV applications.

Butner, C. L.↗

Unstable 06.5f?p star HD 148937 and its interstellar environment

The massive, early-type star HD 148937 (spectral type 06.5?p) is surrounded by a unique set of nebulosities. A spherically symmetric Stromgren sphere (Radius approx. - 25 pc), an ellipsoidal filamentary nebulosity (semimajor axis approx. - 5 pc) interpreted as a stellar-wind-blown shell, and a bipolar nebular complex (semimajor axis approx. - 1 pc) with HD 148937 located in the apparent center of symmetry. Observations of these nebulosities are reported (narrow-band charge coupled devices imaging, image dissector scanner (IDS) spectrophotometry, high resolution spectroscopy) in an attempt to establish a consistent model of HD 148937 and its nebulosities.

Leitherer, C.↗

Lightweight Video-Camera Head

Compact, lightweight video camera head constructed by remounting lens and charge-coupled-device image detector from small commercial video camera in separate assembly. Useful in robotics, artificial vision, and vision guidance systems. Designed to be mounted on visor of helmet to monitor motions of eyes in experiments on vestibulo-ocular reflexes.

Proctor, David R.↗

Attitude and articulation control for CRAF/Cassini

The Comet Rendezvous/Asteroid Flyby (CRAF) and Cassini planetary missions provide exciting pointing and control challenges. The mission and science objectives, and an attitude and articulation control concept designed to meet these challenges, are described. CRAF/Cassini mission characteristics which drive pointing and control include: close range flybys of asteroids and icy satellites; Huygens probe guidance and communication; Saturn orbit insertion; comet rendezvous and orbit insertion; closed loop target tracking from a comet orbit perturbed by gas and dust pressure; fine spacecraft pointing for Titan radar mapping and Earth communications; requirements for autonomous failure detection; isolation; recovery; and 13.5 year lifetime. The philosophy and approach chosen to meet these challenges and the overall control architecture are addressed, including operational and autonomous safe modes. Critical functions are highlighted, such as charge coupled device imaging of stars and extended bodies which provide references for inertial and target referenced pointing respectively. Tradeoffs and rationale for the selection and location of sensors and actuators are reviewed.

Bell, C. E.↗

RR Lyrae stars in Local Group galaxies. IV - IC 1613

Deep charge-coupled device images of a field in IC 1613 away from the star forming central regions were taken with the '4-shooter' on the Hale 5 m telescope, and processed to find photometrically measure variable stars. Fifteen RR Lyrae stars were found, and periods, light curves, and finding charts for them are presented. The mean magnitude of RR Lyrae stars in this galaxy is deduced to be 24.90 mag. Assuming the absolute g magnitude for RR Lyraes to be Mg = 0.73 mag, and using extinction Ag = 0.07 mag, a distance modulus of 24.10 +/- 0.27 mag is derived. The finding of RR Lyrae stars indicates the unambiguous presence of an old population. The distance modulus derived from them is smaller than that derived from the Cepheids by an amount which is dependent upon the RR Lyrae zero-point calibration adopted, and may be as large as 0.3 mag. The difference has the same sense and magnitude as the discrepancy in the LMC. The probable sources of the problem are discussed.

Saha, A.↗

Degradation of optical components in space

This report concerns two types of optical components: multilayer filters and mirrors, and self-scanned imaging arrays using charge coupled device (CCD) readouts. For the filters and mirrors, contamination produces a strong reduction in transmittance in the ultraviolet spectral region, but has little or no effect in the visible and infrared spectral regions. Soft substrates containing halides are unsatisfactory as windows or substrates. Materials choice for dielectric layers should also reflect such considerations. Best performance is also found for the harder materials. Compaction of the layers and interlayer diffusion causes a blue shift in center wavelength and loss of throughput. For sensors using CCD's, shifts in gate voltage and reductions in transfer efficiency occur. Such effects in CCD's are in accord with expectations of the effects of the radiation dose on the device. Except for optical fiber, degradation of CCD's represents the only ionizing-radiation induced effect on the Long Duration Exposure Facility (LDEF) optical systems components that has been observed.

Blue, M. D.↗

A fuzzy structural matching scheme for space robotics vision

In this paper, we propose a new fuzzy structural matching scheme for space stereo vision which is based on the fuzzy properties of regions of images and effectively reduces the computational burden in the following low level matching process. Three dimensional distance images of a space truss structural model are estimated using this scheme from stereo images sensed by Charge Coupled Device (CCD) TV cameras.

Naka, Masao↗