Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Detection of DNA Damage by Space Radiation in Human Fibroblasts Flown on the International Space Station

Although charged particles in space have been detected with radiation detectors on board spacecraft since the discovery of the Van Allen Belts, reports on the effects of direct exposure to space radiation in biological systems have been limited. Measurement of biological effects of space radiation is challenging due to the low dose and low dose rate nature of the radiation environment, and due to the difficulty in distinguishing the radiation effects from microgravity and other space environmental factors. In astronauts, only a few changes, such as increased chromosome aberrations in their lymphocytes and early onset of cataracts, are attributed primarily to their exposure to space radiation. In this study, cultured human fibroblasts were flown on the International Space Station (ISS). Cells were kept at 37 degrees Centigrade in space for 14 days before being fixed for analysis of DNA damages with the gamma-H2AX assay. The 3-dimensional gamma-H2AX foci were captured with a laser confocal microscope. Quantitative analysis revealed several foci that were larger and displayed a track pattern only in the Day 14 flight samples. To confirm that the foci data from the flight study was actually induced from space radiation exposure, cultured human fibroblasts were exposed to low dose rate gamma rays at 37 degrees Centigrade. Cells exposed to chronic gamma rays showed similar foci size distribution in comparison to the non-exposed controls. The cells were also exposed to low- and high-LET (Linear Energy Transfer) protons, and high-LET Fe ions on the ground. Our results suggest that in G1 human fibroblasts under the normal culture condition, only a small fraction of large size foci can be attributed to high-LET radiation in space.

Lu, Tao↗

The challenge to detect and attribute effects of climate change on human and natural systems

Anthropogenic climate change has triggered impacts on natural and human systems world-wide, yet the formal scientific method of detection and attribution has been only insufficiently described. Detection and attribution of impacts of climate change is a fundamentally cross-disciplinary issue, involving concepts, terms, and standards spanning the varied requirements of the various disciplines. Key problems for current assessments include the limited availability of long-term observations, the limited knowledge on processes and mechanisms involved in changing environmental systems, and the widely different concepts applied in the scientific literature. In order to facilitate current and future assessments, this paper describes the current conceptual framework of the field and outlines a number of conceptual challenges. Based on this, it proposes workable cross-disciplinary definitions, concepts, and standards. The paper is specifically intended to serve as a baseline for continued development of a consistent cross-disciplinary framework that will facilitate integrated assessment of the detection and attribution of climate change impacts.

54 ENVIRONMENTAL SCIENCES↗

Detection of DNA Damage by Space Radiation in Human Fibroblast Cells Flown on the International Space Station

Although charged particles in space have been detected with radiation detectors on board spacecraft since the early discovery of the Van Allen Belt, reports on effects of direct exposure to space radiation in biological systems have been limited. Measurement of biological effects of space radiation has been difficult due to the low dose and low dose rate nature of the radiation environment, and the difficulty in separating the radiation effects from microgravity and other space environmental factors. In astronauts, only a small number of changes, such as increased chromosome aberrations in lymphocytes and early onset of cataracts, attributed primarily to the exposure to space radiation. In a recent experiment, human fibroblast cells were flown on the International Space Station (ISS). Cells fixed on Days 3 and 14 after reaching orbit were analyzed for phosphorylation of a histone protein H2AX by immunofluorescent staining of cells, which is a widely used marker for DNA double strand breaks. The 3-dimensional gamma-H2AX foci were captured with a laser confocal microscope. Quantitative analysis revealed a small fraction of foci that were larger and displayed a track pattern in the flight samples in comparison to the ground control. Human fibroblast cells were also exposed to low dose rate gamma rays, as well as to protons and Fe ions. Comparison of the pattern and distribution of the foci after gamma ray and charged particle exposure to our flight results confirmed that the foci found in the flown cells were indeed induced by space radiation.

Wu, Honglu↗

Universal human papillomavirus typing by whole genome sequencing following target enrichment: evaluation of assay reproducibility and limit of detection

We recently described a method for unbiased detection of all known human papillomaviruses (HPV) types with the potential for the determination of their variant and integration from the resulting whole genome sequence data. Considering the complex workflow for target-enriched next generation sequencing (NGS), we focused on the reproducibility and limit of detection (LOD) of this new universal HPV typing assay in this study. We evaluated the reproducibility and LOD for HPV genotyping based on our recently published method that used RNA-baits targeting whole genomes of 191 HPV types, Agilent SureSelect protocol for target enrichment and Illumina HiSeq 2500 for sequencing (eWGS, enriched whole genome sequencing). Two libraries, prepared from pooled plasmids representing 9 vaccine HPV types at varying input (1–625 copies/reaction), were sequenced twice giving four replicates for evaluating reproducibility and LOD. eWGS showed high correlation in the number of reads mapped to HPV reference genomes between the two flow-cell lanes within (R 2 = 1) and between experiments (R 2 = 0.99). The number of mapped reads was positively correlated to copy number (β = 13.9, p < 0.0001). The limit of blank (LOB) could be calculated based on mapped reads to HPV types not included in each sample. HPV genotyping was reproducible for all 9 types at 625 copies using multiple cut-off criteria but LOD was 25 copies based on number of reads above LOB even when multiple types were present. eWGS showed no bias for HPV genotyping under single or multiple infection (p = 0.16–0.99). The universal eWGS method for HPV genotyping has sensitivity, competitive with widely used consensus PCR methods with reduced type competition, and with the potential for determination of variant and integration status. The protocol used in this study, using defined samples varying in complexity and copy number, analyzed in replicate and duplicate assays, is applicable to most WGS methods.

59 BASIC BIOLOGICAL SCIENCES↗

Multiplex detection and identification of viral, bacterial, and protozoan pathogens in human blood and plasma using an expanded high-density resequencing microarray platform

Introduction: Nucleic acid tests for blood donor screening have improved the safety of the blood supply; however, increasing numbers of emerging pathogen tests are burdensome. Multiplex testing platforms are a potential solution. Methods: The Blood Borne Pathogen Resequencing Microarray Expanded (BBP-RMAv.2) can perform multiplex detection and identification of 80 viruses, bacteria and parasites. This study evaluated pathogen detection in human blood or plasma. Samples spiked with selected pathogens, each with one of 6 viruses, 2 bacteria and 5 protozoans were tested on this platform. The nucleic acids were extracted, amplified using multiplexed sets of primers, and hybridized to a microarray. The reported sequences were aligned to a database to identify the pathogen. To directly compare the microarray to an emerging molecular approach, the amplified nucleic acids were also submitted to nanopore next generation sequencing (NGS). Results: The BBP-RMAv.2 detected viral pathogens at a concentration as low as 100 copies/ml and a range of concentrations from 1,000 to 100,000 copies/ml for all the spiked pathogens. Coded specimens were identified correctly demonstrating the effectiveness of the platform. The nanopore sequencing correctly identified most samples and the results of the two platforms were compared. Discussion: These results indicated that the BBP-RMAv.2 could be employed for multiplex detection with potential for use in blood safety or disease diagnosis. The NGS was nearly as effective at identifying pathogens in blood and performed better than BBP-RMAv.2 at identifying pathogen-negative samples.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor based on Quantum Dots and a Lateral Flow Test Strip

A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescence intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Human-In-The-Loop Experimental Research for Detect and Avoid

This paper describes a Detect and Avoid (DAA) concept for integration of UAS into the NAS developed by the National Aeronautics and Space Administration (NASA) and provides results from recent human-in-the-loop experiments performed to investigate interoperability and acceptability issues associated with these vehicles and operations. The series of experiments was designed to incrementally assess critical elements of the new concept and the enabling technologies that will be required.

Consiglio, Maria↗

Automatically Finding Ship-Tracks to Enable Large-Scale Analysis of Aerosol-Cloud Interactions

Ship tracks appear as long winding linear features in satellite images and are produced by aerosols from ship exhausts changing low cloud properties. They are one of the best examples of aerosol‐cloud interaction experiments. However, manually finding ship tracks from satellite data on a large scale is prohibitively costly while a large number of samples are required to improve our understanding. Here we train a deep neural network to automate finding ship tracks. The neural network model generalizes well as it not only finds ship tracks labeled by human experts but also detects those that are occasionally missed by humans. It finds more ship tracks than all previous studies combined and produces a map of ship track distributions off the California coast that matches well with known shipping traffic. Our technique will enable studying aerosol effects on low clouds using ship tracks on a large scale, which will potentially narrow the uncertainty of the aerosol‐cloud interactions.

aerosol cloud interactions↗

Understanding Virulence in the Brucellae and Francisellae: Towards Efficacious Treatments for Two Potential Biothreat Agents

Francisella tularensis, Yersinia pestis and Brucellae species are highly infectious pathogens classified as select agents by the Centers for Disease Control and Prevention (CDC) with the potential for use in bioterrorism attacks. These organisms are known to be facultative intracellular pathogens that preferentially infect human monocytes. As such, understanding how the host responds to infection with these organisms is paramount in detecting and combating human disease. We have compared the ability of fully virulent strains of each pathogen and their non-pathogenic near neighbors to enter and survive inside the human monocytic cell line THP-1 and have quantified the cellular response to infection with the goal of identifying both unique and common host response patterns. We expanded the scope of these studies to include experiments with pathogenic and non-pathogenic strains of Y. pestis, the causative agent of plague. Nonpathogenic strains of each organism were impaired in their ability to survive intracellularly compared with their pathogenic counterparts. Furthermore, infection of THP-1 cells with pathogenic strains of Y. pestis and F. tularensis resulted in marked increases in the secretion of the inflammatory chemokines IL-8, RANTES, and MIP-1{beta}. In contrast, B. melitensis infection failed to elicit any significant increases in a panel of cytokines tested. These differences may underscore distinct strategies in pathogenic mechanisms employed by these pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Inflight Microbial Monitoring - An Alternative Method to Culture Based Detection Currently Used on the International Space Station

Microorganisms including potential human pathogens have been detected on the International Space Station (ISS). The potential to introduce new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Current microbial monitoring methods require enrichment of microorganisms and a 48-hour incubation time resulting in an increase in microbial load, detecting a limited number of unidentified microorganisms. An expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted.

International Space Stateion↗