Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sizing Small-Scale Renewable Energy Systems for the Navajo Nation and Rural Communities

The Navajo Nation consists of about 55,000 residential homes spread across 27,000 square miles of trust land in the Southwest region of the United States. The Navajo Tribal Utility Authority (NTUA) reports that approximately 15,000 homes on the reservation do not have electricity due to the high costs of connecting rural homes located miles from utility distribution lines. In order to get these rural homeowners access electricity, NTUA and other Native owned companies are examining small-scale renewable energy systems to provide power for necessary usage such as lighting and refrigeration. The goal of this study is to evaluate the current renewable deployment efforts and provide additional considerations for photovoltaic (PV) systems that will optimize performance and improve efficiency to reduce costs. There are three case studies presented in different locations on the Navajo Nation with varying solar resource and energy load requirements. For each location, an assessment is completed that includes environmental parameters of the site- specific landscape and a system performance analysis of an off-grid residential PV system. The technical process, repeated for each location, demonstrates how the variance and uniqueness of each household can impact the system requirements after optimizations are applied. Therefore, the household variabilities and difference in locations must be considered. The differing results of each case study suggests additional analysis is needed for designing small-scale PV systems that takes a home-land-family specific approach to allow for better efficiency and more flexibility for future solar innovations to be considered for overall cost reductions.

14 SOLAR ENERGY↗

Modeling the smoky troposphere of the southeast Atlantic: a comparison to ORACLES airborne observations from September of 2016

The southeast Atlantic is home to well-defined smoke outflow from Africa coinciding vertically with extensive marine boundary-layer cloud decks, both reaching their climatological maxima in spatial extent around September. A framework is put forth for evaluating the performance of a range of global and regional aerosol models against observations made during the NASA ORACLES (ObseRvations of Aerosols above CLouds and their intEractionS) airborne mission in September 2016. The sparse airborne observations are first aggregated into 2o grid boxes and into three vertical layers: the cloud-topped marine boundary layer (MBL), the layer from cloud top to 3 km, and the 3-6 km layer. Aerosol extensive properties simulated for the entire study region for all September suggest that the 2016 ORACLES observations are reasonably representative of the regional monthly average, with systematic deviations of 30% or less. All six models typically place the bottom of the smoke layer at lower altitudes than do the airborne lidar observations by 300-1400 m, whereas model aerosol top heights are within 0-500 m of the observations. All but one of the models that report carbonaceous aerosol masses underestimate the ratio of particulate extinction to the masses, a proxy for mass extinction efficiency, in 3-6 km. Notable findings on individual models include that WRF-CAM5 predicts the mass of black carbon and organic aerosols with minor (~10% or less) biases. GEOS-5 overestimates the carbonaceous particle masses in the MBL by a factor of 3-6. Extinction coefficients in the free troposphere (FT) and above-cloud aerosol optical depth (ACAOD) are 10-30% lower in WRF-CAM5, 30-50% lower in GEOS-5, 10-40% higher in GEOS-Chem, 10-20% higher in EAM-E3SM except for the practically unbiased 3-6 km extinction, and 20-70% lower in the Unified Model, than the airborne in situ, lidar and sunphotometer measurements. ALADIN-Climate also underestimates the ACAOD, by 30%. GEOS-5 and GEOS-Chem predict carbon monoxide in the MBL with small (10% or less) negative biases, despite their overestimates of carbonaceous aerosol masses. Overall, this study highlights a new approach to utilizing airborne aerosol measurements for model diagnosis.

Shinozuka, Yohei↗

Propagating synthetic populations with dynamic Bayesian networks: a framework for long-horizon demographic forecasting

This study presents a dynamic demographic microsimulator using dynamic Bayesian networks to forecast long–term changes in household and individual life events. Leveraging longitudinal Panel Study of Income Dynamics (PSID) data, two networks for individuals and households were modeled to simulate transitions in employment, income, education, marriage, childbirth, leaving the parental home, home ownership, mortality, and household formation or dissolution. Across 1,000 simulation runs spanning 24 years, household–level outcomes remain highly accurate and individual–level predictions reasonable. Although accuracy naturally declines with projection horizon, performance remains promising at both levels. This study addresses a key limitation of existing population synthesis models, which typically generate only a single static snapshot of the population. In conclusion, by introducing a framework that propagates cross-sectional outputs into the future, the microsimulator enables the tracking of demographic evolution over time, enhances realism in population-based simulations, and supplies credible inputs to agent-based travel demand models.

Demographic modeling↗

Sustainability and affordability of building electrification: A state-by-state holistic approach for multifamily buildings

This paper explores the evolving narrative of building electrification, considering its potential to solve climate change. Previous research has predominantly focused on hybrid renewable energy portfolios and increasing home pricing premiums, overlooking the perspectives of renters burdened by housing costs. Moreover, existing studies have primarily examined the effects of electrification on single-family homes and case studies, neglecting multifamily buildings and their relationship with the grid. This comprehensive study leverages calibrated building energy models to address these gaps and evaluates sustainability through carbon dioxide emissions and affordability through economic performance. The findings demonstrate significant progress in electrification since 2017, with nearly all states showing decreased energy usage in the electrified models. Environmentally, twenty-two states perform better or comparably with the electrified models in the most recent study. Economically, challenges persist, but a sensitivity analysis demonstrates how results could improve soon. Furthermore, the study discusses the outlook of electrified multifamily buildings, considering ongoing decarbonization plans for the electric grid. In three case studies, electrification demonstrates improvements in over half of the states by 2026. Overall, the research highlights the importance of expanding analysis to include multifamily buildings and emphasizes the positive impact of electrification as a viable energy, environmental, and economic solution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frictional and Lithological Controls on Shallow Slow Slip at the Northern Hikurangi Margin

Slow slip events (SSEs) have been identified at subduction zones globally as an important link in the continuum between elastodynamic ruptures and stable creep. The northern Hikurangi margin is home to shallow SSEs which propagate to within 2 km of the seafloor and possibly to the trench, providing insights into the physical conditions conducive to SSE behavior. We report on a suite of friction experiments performed on protolith material entering the SSE source region at the Hikurangi margin, collected during the International Ocean Discovery Program Expedition 375. We performed velocity stepping and slide-hold-slide experiments over a range of fault slip rates, from plate rate (5 cm/yr or 1.6 × 10 –9 m/s) to ~1 mm/s (10 –3 m/s) and quantified the frictional velocity dependence and healing rates for a range of lithologies atdifferent stresses. The frictional velocity dependence (a-b) and critical slip distance DC increase with fault slip rate in our experiments. We observe atransition from velocity weakening to strengthening at slip rates of ~0.3 µm/s. This velocity dependence of DC could be due to a combination of dilatant strengthening and a widening of the active shear zone at higher slip rates. We document low healing rates in the clay-rich volcaniclastic conglomerates, which lie above the incoming plate basement at least locally, and relatively higher healing rates in the chalk lithology. Finally, our experimental constraints on healing rates in different input lithologies extrapolated to timescales of 1–10 years are consistent with the geodetically inferred low stress drops and healing rates characteristic of the Hikurangi SSEs.

58 GEOSCIENCES↗

Design and Implementation of Smart Buildings: A Review of Current Research Trend

The building sector is one of the largest contributors to the world’s total energy use and greenhouse gas emissions. Advancements in building energy technologies have played a critical role in enhancing the energy sustainability of the built environment. Extensive research and new techniques in energy and environmental systems for buildings have recently emerged to address the global challenges. This study reviews existing articles in the literature, mostly since 2000, to explore technological advancement in building energy and environmental systems that can be applied to smart homes and buildings. This review study focuses on an overview of the design and implementation of energy-related smart building technologies, including energy management systems, renewable energy applications, and current advanced smart technologies for optimal function and energy-efficient performance. To review the advancement in building energy-related technologies, a systematic review process is adopted based on available published reviews and research types of articles. Review-type articles are first assessed to explore the current literature on the relevant keywords and to capture major research scopes. Research-type papers are then examined to investigate associated keywords and work scopes, including objectives, focuses, limitations, and future needs. Throughout the comprehensive literature review, this study identifies various techniques of smart home/building applications that have provided detailed solutions or guidelines in different applications to enhance the quality of people’s daily activities and the sustainability of the built environmental system. This paper shows trends in human activities and technology advancements in digital solutions with energy management systems and practical designs. Understanding the overall energy flow between a building and its environmentally connected systems is also important for future buildings and community levels. This paper assists in understanding the pathway toward future smart homes/buildings and their technologies for researchers in related research fields.

renewable system integration↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measured air quality impacts after teaching parents about cooking ventilation with a video: a pilot study

BackgroundCooking-related emissions contribute to air pollutants in the home and may influence children’s health outcomes.ObjectiveIn this pilot study, we investigate the effects of a cooking ventilation intervention in homes with gas stoves, including a video-based educational intervention and range hood replacement (when needed) in children’s homes.MethodsThis was a pilot (n = 14), before-after trial (clinicaltrials.gov #NCT04464720) in homes in the San Francisco Bay Area that had a school-aged child, a gas stove, and either a venting range hood or over-the-range microwave/hood. Cooking events, ventilation use, and indoor air pollution were measured in homes for 2–4 weeks, and children completed respiratory assessments. Midway, families received this intervention: (1) education about the hazards of cooking-related pollutants and benefits of both switching to back burners and using the range hood whenever cooking and (2) ensuring the range hood met airflow and sound performance standards. The educational intervention was delivered via a video developed in conjunction with local youth.ResultsWe found substantially increased use of back burners and slight increases in range hood use during cooking after intervening. Even though there was no change in cooking frequency or duration, these behavior changes resulted in decreases in nitrogen dioxide (NO2), including significant decreases in the total integrated concentration of NO2 over all cooking events from 1230 ppb*min (IQR 336, 7861) to 756 (IQR 84.0, 4210; p < 0.05) and NO2 collected on samplers over the entire pre- and post-intervention intervals from 10.4 ppb (IQR 3.5, 47.5) to 9.4 (IQR 3.0, 36.1; p < 0.005). There were smaller changes in PM2.5, and no changes were seen in respiratory outcomes.ImpactThis pilot before-after trial evaluated the use of a four-minute educational video to improve cooking ventilation in homes with gas stoves and one or more school-aged children. Participant behavior changed after watching the video, and there were decreases in indoor air pollutant concentrations in the home, some of which were significant. This brief video is now publicly available in English and Spanish (wspehsu.ucsf.edu/projects/indoor-air-quality), and this provides suggestive evidence of the utility of this simple intervention, which could be particularly beneficial for households that have children with asthma.

Holm, Stephanie M↗

Validation of the Public Radiation Exposure Calculation for the Incident at the National Institute of Standards and Technology Center for Neutron Research on February 3, 2021

The Department of Energy/National Nuclear Security Administration Consequence Management Program was contacted by the Health Physics Chief of the National Institute of Standards and Technology Center for Neutron Research (NCNR) to review public radiation exposure calculations for an event that occurred on its Gaithersburg, Maryland, campus on February 3, 2021. Subject matter experts from the Nuclear Emergency Support Team (NEST) assets, specifically the Consequence Management Home Team (CMHT) and the National Atmospheric Release Advisory Center (NARAC), were selected to provide support. CMHT used three separate modeling codes to validate the results the scientists at NCNR calculated using the HotSpot model. The analyses were performed using NARAC’s in-house Lagrangian dispersion codes known as LODI and Aeolus, as well as the Turbo FRMAC software from Sandia National Laboratories. The team used parameters provided by the NCNR scientists regarding the site, applicable observable meteorological data, and environmental survey and sampling data to estimate public exposure. Each model estimated public dose at much less than 0.5 mrem. CMHT concurs with the NCNR public radiation exposure calculations which state that members of the public at the 400-meter boundary would have received a radiological dose of less than 0.5 mrem.

61 RADIATION PROTECTION AND DOSIMETRY↗

Durability of ABC Team Wall Assemblies

This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Battery Modeling for Control-Oriented Techno-Economic Studies: Preprint

Electrochemical batteries, which serve as electric energy storage devices, are becoming increasingly popular among residential buildings that incorporate solar photovoltaic (PV) systems to help meet their energy needs. Battery economics are affected by performance degradation over time, and managing this degradation can help extend the battery's lifespan. The tradeoff between operational costs/benefits and managing battery degradation is of significant research interest. One of the key factors for assessing battery degradation is the dispatch strategy used to control the charging and discharging of the battery. Conventional dispatch strategies typically use simple rule-based methods, and these overly aggressive charging/discharging cycles can significantly reduce a battery’s life span. Our research seeks to develop optimized dispatch strategies for grid-connected PV homes with a goal of extending battery life while simultaneously taking into consideration utility costs and occupant comfort. To achieve this goal, we adapted lithium-ion battery life- and cyclic-degradation models for use in high-fidelity building simulations, so whole-building and grid-interactive controllers can dispatch the batteries along with other flexible loads. With the help of a co-simulation platform, we performed a simulation study to compute the optimized dispatch strategies for relevant operating conditions brought about by changing geographical locations, weather conditions, and utility pricing. Comparing the optimized strategies with the conventional strategies resulted in a >50% decrease in capacity degradation and >10% average reduction in operational costs during the months of January and July in Fort Collins, Colorado; Phoenix, Arizona; and Portland, Oregon.

30 DIRECT ENERGY CONVERSION↗

Synthetic Biology Toolbox for Nitrogen-Fixing Soil Microbes

The soil environment adjacent to plant roots, termed the rhizosphere, is home to a wide variety of microorganisms that can significantly affect the physiology of nearby plants. Microbes in the rhizosphere can provide nutrients, secrete signaling compounds, and inhibit pathogens. These processes could be manipulated with synthetic biology to enhance the agricultural performance of crops grown for food, energy, or environmental remediation, if methods can be implemented in these nonmodel microbes. A common first step for domesticating nonmodel organisms is the development of a set of genetic engineering tools, termed a synthetic biology toolbox. A toolbox comprises transformation protocols, replicating vectors, genome engineering (e.g., CRISPR/Cas9), constitutive and inducible promoter systems, and other gene expression control elements. Furthermore, this work validated synthetic biology toolboxes in three nitrogen-fixing soil bacteria: Azotobacter vinelandii, Stutzerimonas stutzeri (Pseudomonas stutzeri), and a new isolate of Klebsiella variicola. All three organisms were amenable to transformation and reporter protein expression, with several functional inducible systems available for each organism. S. stutzeri and K. variicola showed more reliable plasmid-based expression, resulting in successful Cas9 recombineering to create scarless deletions and insertions. Using these tools, we generated mutants with inducible nitrogenase activity and introduced heterologous genes to produce resorcinol products with relevant biological activity in the rhizosphere.

59 BASIC BIOLOGICAL SCIENCES↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential impact of work from home jobs on residential energy bills: A case study in phoenix, AZ, USA

Nearly one-third of U.S. households face challenges paying energy bills. During the day, many residents have routine access to cooled environments provided by others—employers, shopping centers, and other public buildings. The COVID-19 pandemic, however, has significantly shifted the cost burden of air conditioning in hot cities. Specifically, during the pandemic, many companies either laid off employees or put them in work-from-home (WFH) assignments. Large tech companies are already promoting WFH as a long-term option for their employees, even after the pandemic. This change in the nature of the workforce might reduce daily travel expenses for workers, but could also significantly increase residential energy bills, particularly during summer in very hot climates. Here, this study uses building energy simulations to quantify the potential residential energy bill penalties resulting from WFH for typical residences in Phoenix. Four building archetypes are used in this study to represent variations in building vintage, occupancy, and characteristics. The results show that, for some single-family residences in Phoenix, WFH can increase annual energy bills by more than $1100 (up to a 70% increase). The study also demonstrates that building performance enhancement retrofit measures have the potential to reduce this WFH energy bill penalty for the existing buildings substantially.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lineshape characterization of excitons in monolayer WS 2 by two-dimensional electronic spectroscopy

The optical properties of monolayer transition metal dichalcogenides (TMDCs), an important family of two-dimensional (2D) semiconductors for optoelectronic applications, are dominated by two excitons A (XA) and B (XB) located at K/K's valleys. The lineshape of the excitons is an indicator of the interaction of the excitons with other particles and also largely determines the performance of TMDC-based optoelectronic devices. In this work, we apply 2D electronic spectroscopy (2DES), which enables separation of the intrinsic homogeneous linewidth and the extrinsic inhomogeneous linewidth, to dissect the lineshape of XA in monolayer WS 2 . With a home-built broadband optical parametric amplifier, the 2D spectra give the exciton linewidth values for extensive ranges of excitation densities and temperatures, reflecting inter-exciton and exciton–phonon interactions. Meanwhile, the time-domain evolution of the lineshape reveals a similar rate of spectral diffusion to that in quantum wells (QWs) based on III–V semiconductors.

36 MATERIALS SCIENCE↗

Understanding Operando Water Management in Hydroxide‐Exchange‐Membrane Fuel Cells

The water balance in hydroxide-exchange-membrane fuel cells (HEMFCs) is a key challenge for improved performance and durability, intimately linked with the various interfaces and coupled phenomena. For every 4 electrons produced, 4 water molecules are generated in the anode and 2 consumed in the cathode, while electroosmosis transports water across the HEM from the cathode to the anode. Consequently, a concentration gradient drives water back, from anode to cathode. Ineffective water management could lead to cathode dry-out, limiting reaction rate and causing ionomer degradation, or to anode flooding. To address these concerns, it is critical to measure the water transport operando . Herein, a home-built water-flux station is used to measure total water flux during cell operation with different inlet relative humidities and back pressures. Increasing the HEM thickness fourfold decreases the water flux at high current density, and utilizing microporous layers on both the anode and cathode decreases the water flux from the anode to the cathode. However, the most significant variable in changing the water flux was found by increasing the anode back pressure. Furthermore, humidity cycling significantly changed electrochemical performance without affecting the overall water fluxes. These findings can be translated to other devices utilizing an HEM.

AEMFC↗

Productive Programming of Distributed Systems with the SHAD C++ Library

High-performance computing (HPC) is often perceived as a matter of making large-scale systems (e.g., clusters) run as fast as possible, regardless the required programming effort. However, the idea of "bringing HPC to the masses" has recently emerged. Inspired by this vision, we have designed SHAD, the Scalable High-performance Algorithms and Data-structures library. SHAD is open source software, written in C++, for C++ developers. Unlike other HPC libraries for distributed systems, which rely on SPMD models, SHAD adopts a shared-memory programming abstraction, to make C++ programmers feel at home. Underneath, SHAD manages tasking and data-movements, moving the computation where data resides and taking advantage of asynchrony to tolerate network latency. At the bottom of his stack, SHAD can interface with multiple runtime systems: this not only improves developer’s productivity, by hiding the complexity of such software and of the underlying hardware, but also greatly enhance code portability. Thanks to its abstraction layers, SHAD can indeed target different systems, ranging from laptops to HPC clusters, without any need for modifying the user-level code. We have prototyped and open-sourced the implementation of (a subset of) the C++ standard library (STL) targeting multi-node HPC clusters. Our work allows plain STL-based C++ code to scale on HPC systems, with no need for rewriting the code to exploit the complex hardware. SHAD is available under Apache v2 License at https://github.com/pnnl/SHAD. In this paper we overview the design of the SHAD library, depicting its main components: runtime systems abstractions for tasking; parallel and distributed data-structures; STL-compliant interfaces and algorithms.

Castellana, Vito G.↗