Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high performance building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Building Energy Codes Resource Guide: Commercial Buildings for Architects

The Commercial Buildings for Architects Resource Guide provides key energy code information tailored for architects, and was designed in partnership with the American Institute of Architects (AIA). It offers guidance on how architects can support adoption of new or updated energy codes, and resources needed to enable compliance with the adopted code. The guide includes information on the importance of architects in the development and compliance verification processes, the interface between codes and the design process, design and compliance tools, and building construction and commissioning. It also includes many other resources to help architects understand the important role that the design process of energy codes plays in addressing our energy, economic and environmental challenges.

Code development and adoption, high-performance bu↗

New Whole-House Solutions Case Study: Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40, Harvard, Massachusetts

Achieving aggressive energy efficiency targets requires tight coordination and clear communication among owners, designers, builders, and subcontractors. For this townhome project, MassDevelopment, the quasi-governmental agency owner, selected Metric Development of Boston, teaming with Building America team Consortium for Advanced Residential Buildings (CARB) and Cambridge Seven Architects, to build very high performing market-rate homes. Fort Devens is part of a decommissioned army base in working-class Harvard, Massachusetts, approximately one hour northwest of Boston. The team proposed 12 net zero energy-ready townhomes that were also designed to achieve a Home Energy Rating System (HERS) Index Score of 41 before adding renewables. The team carefully planned the site to maximize solar access, daylighting, and efficient building forms.

air tight envelope↗

Laboratory Efficiency Strategies and the Smart Labs Program

Focusing on critical spaces, such as labs, will enable agencies to prioritize federal energy efficiency and decarbonization goals. FEMP's Smart Labs program is an example of emerging efficient laboratory building strategies. The benefits of this program include improved safety and health, reduced energy consumption and carbon emissions, lower operating costs, reduced degradation, and increased retention and recruitment of top talent researchers and sciences. In this session, with the help of our national lab partners, Sandia National Laboratory and Lawrence Berkeley National Laboratory, you will learn about the steps to implement a Smart Labs program of your own and the methods behind the high-performance laboratory building. The partners will share best practices in implementation, practical advice for building a team, and how to address these critical facilities.

decarbonization↗

Development of Liquid Propulsion Systems Testbed at MSFC

As NASA, the Department of Defense and the aerospace industry in general strive to develop capabilities to explore near-Earth, Cis-lunar and deep space, the need to create more cost effective techniques of propulsion system design, manufacturing and test is imperative in the current budget constrained environment. The physics of space exploration have not changed, but the manner in which systems are developed and certified needs to change if there is going to be any hope of designing and building the high performance liquid propulsion systems necessary to deliver crew and cargo to the further reaches of space. To further the objective of developing these systems, the Marshall Space Flight Center is currently in the process of formulating a Liquid Propulsion Systems testbed, which will enable rapid integration of components to be tested and assessed for performance in integrated systems. The manifestation of this testbed is a breadboard engine configuration (BBE) with facility support for consumables and/or other components as needed. The goal of the facility is to test NASA developed elements, but can be used to test articles developed by other government agencies, industry or academia. Joint government/private partnership is likely the approach that will be required to enable efficient propulsion system development. MSFC has recently tested its own additively manufactured liquid hydrogen pump, injector, and valves in a BBE hot firing. It is rapidly building toward testing the pump and a new CH4 injector in the BBE configuration to demonstrate a 22,000 lbf, pump-fed LO2/LCH4 engine for the Mars lander or in-space transportation. The value of having this BBE testbed is that as components are developed they may be easily integrated in the testbed and tested. MSFC is striving to enhance its liquid propulsion system development capability. Rapid design, analysis, build and test will be critical to fielding the next high thrust rocket engine. With the maturity of the BBE testbed, MSFC propulsion engineering will bring forward a national capability that enables growth of both commercial and government interests.

Alexander, Reginald↗

Redox-stable symmetrical solid oxide fuel cells with exceptionally high performance enabled by electrode/electrolyte diffuse interface

Here, in this study, we report a high performance and redox-stable symmetrical solid oxide fuel cell (SOFC) based on (Ba 0.5 Sr 0.5 ) (Mo 0.1 Fe 0.9 )O 3-δ (BSMF) electrode and La 0.8 Sr 0.2 Ga 0.8 Mg 0.2 O 3-δ (LSGM) electrolyte. BSMF is able to operate both as anode and cathode. Excellent electrocatalytic activity has been achieved on BSMF towards hydrogen oxidation and oxygen reduction. Due to its closely matched lattice parameter to LSGM electrolyte, a unique diffuse interface is formed between BSMF and LSGM. Compared to a clean interface, e.g. BSMF/gadolinium doped ceria interface, this diffuse interface promotes the performance of BSMF electrode 1–1.8 times in 600–800 °C. Polarization resistance of the BSMF/LSGM specimen is as low as 0.047 and 0.007 Ωcm 2 in humidified H 2 and in air at 800 °C, respectively. On the BSMF/LSGM/BSMF symmetrical cell, a maximum power density of 2.28 W/cm 2 is achieved at 800 °C, the highest among with redox-stable ceramic electrodes to the best of our knowledge. Redox stability of this cell is confirmed. The role of anode and cathode is reversed back and forth in different operation modes. No apparent degradation is observed through 4 cycles within a 110 h operation period. These findings demonstrate that (Ba 0.5 Sr 0.5 ) (M o0.1 Fe 0.9 )O 3-δ coupled with LSGM electrolyte is an excellent choice to build a high performance, redox-stable SOFC.

25 ENERGY STORAGE↗

High Performance Builder Spotlight: Imagine Homes

Imagine Homes, working with the DOE's Building America research team member IBACOS, has developed a system that can be replicated by other contractors to build affordable, high-performance homes. Imagine Homes has used the system to produce more than 70 Builders Challenge-certified homes per year in San Antonio over the past five years.

builders challenge↗

Indoor air quality in 24 California residences designed as high-performance homes

Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH 50 , n=11 and n=8, respectively), their use of mechanical ventilation systems and possibly window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr -1 , n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Importance of Window Installation in Residential Building Envelopes Having Continuous External Insulation in Order to Realize Energy Efficiency

Residential buildings are one of the prime candidates in the United States for reducing energy consumption. Continuous exterior insulation (CEI) is being used increasingly often in residential buildings to improve energy efficiency. Windows constitute 15–40% of a building envelope and are the weakest component in energy performance. The installation of windows in walls with CEI has not been well evaluated. We identified four cases of installing windows in walls with CEI of 25–76 mm (1–3 in.) thickness and analyzed the energy loss between the window and wall interface (flanking loss), structural issues, air leakage, and moisture penetration. Thermal analysis showed that the insulation value (RSI) of the 305 mm (12 in.) perimeter wall surrounding a window decreased by 7.6–34.5% in the four cases when compared with the RSI of the wall without the window. A window installation method is proposed to address the issues likely to occur with installation methods currently being used in the field. An out-of-the-box installation system was also designed to achieve a better thermal performance, cost effectiveness, and structural performance in high-performance residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reversible aqueous zinc/manganese oxide energy storage from conversion reactions

Rechargeable aqueous batteries are attracting growing interest for energy storage due to their low cost and high safety. Fundamental understanding of highly reversible aqueous reactions is critical for building high-performance batteries. Herein, we studied the reversibility of Zn/MnO2 battery chemistry in mild aqueous MnSO4 electrolytes. α-MnO2 nanofibers were used as a high performance cathode. Our study provides good evidence for a conversion reaction mechanism through reversible formation of short nanorods and nanoparticle aggregates. This reversible conversion reaction provides an operating voltage of 1.44 V, high capacity of 285 mAh g-1, excellent rate and capacity retention of 92% after 5000 cycles. Zn metal anode also shows high reversibility in the mild aqueous MnSO4 electrolytes. The highly reversible and stable chemistries in aqueous Zn/MnO2 batteries open new opportunity for energy storage technologies with potentially high energy density, high safety, and low cost.

Environmental Molecular Sciences Laboratory↗

On-demand data analytics in HPC environments at leadership computing facilities: Challenges and experiences

Scaling-up scientific data analysis and machine learning algorithms for data-driven discovery is a grand challenge that we face today. Despite the growing need for analysis from science domains that are generating `Big Data' from instruments and simulations, building high-performance analytical workflows of data-intensive algorithms have been daunting because: (i) the `Big Data' hardware and software architecture landscape is constantly evolving, (ii) newer architectures impose new programming models, and (iii) data-parallel kernels of analysis algorithms and their performance facets on different architectures are poorly understood. To address these problems, we have: (i) identified scalable data-parallel kernels of popular data analysis algorithms, (ii) implemented `Mini-Apps' of those kernels using different programming models (e.g. Map Reduce, MPI, etc.), (iii) benchmarked and validated the performance of the kernels in diverse architectures. In this paper, we discuss two of those Mini-Apps and show the execution of principal component analysis built as a workflow of the Mini-Apps. We show that Mini-Apps enable scientists to (i) write domain-specific data analysis code that scales on most HPC hardware and (ii) and offers the ability (most times with over a 10x speed-up) to analyze data sizes 100 times the size of what off-the-shelf desktop/workstations of today can handle.

Harney, John↗

P4: Portable Parallel Processing Pipelines for Interactive Information Visualization

We present P4, an information visualization toolkit that combines declarative design specification and GPU computing for building high-performance interactive systems. Most of the existing information visualization toolkits do not harness the power of parallel processors in today's mainstream computers. P4 leverages GPU computing to accelerate both data processing and visualization rendering for interactive visualization applications. P4's programming interface offers a declarative visualization grammar for rapid specifications of data transformations, visual encodings, and interactions. By simplifying the development of GPU-accelerated visualization systems while supporting a high degree of flexibility and customization for design specification, P4 narrows the gap between expressiveness and scalability in information visualization toolkits. Through a range of examples and benchmark tests, we demonstrate that P4 provides high efficiency for creating interactive visualizations and offers drastic performance improvement over current state-of-the-art toolkits.

97 MATHEMATICS AND COMPUTING↗

Preparing an Incompressible-Flow Fluid Dynamics Code for Exascale-Class Wind Energy Simulations

The U.S. Department of Energy has identified exascale-class wind farm simulation as critical to wind energy scientific discovery. A primary objective of the ExaWind project is to build high-performance, predictive computational fluid dynamics (CFD) tools that satisfy these modeling needs. GPU accelerators will serve as the computational thoroughbreds of next-generation, exascale-class supercomputers. Here, we report on our efforts in preparing the ExaWind unstructured mesh solver, Nalu-Wind, for exascale-class machines. For computing at this scale, a simple port of the incompressible-flow algorithms to GPUs is insufficient. To achieve high performance, one needs novel algorithms that are application aware, memory efficient, and optimized for the latest-generation GPU devices. The result of our efforts are unstructured-mesh simulations of wind turbines that can effectively leverage thousands of GPUs. In particular, we demonstrate a first-of-its-kind, incompressible-flow simulation using Algebraic Multigrid solvers that strong scales to more than 4000 GPUs on the Summit supercomputer.

algebraic multigrid↗

Middleware for Data Intensive Computing

MeDICi is an evolving middleware platform for building complex, high performance analytical applications. These applications typically comprise a pipeline of software components, each of which performs some analysis on incoming data and passes on its results to the next step in the pipeline.

Gorton, Ian↗

Y-12 Site-Sustainability Plan 2010

The accomplishments to date and the long-range planning of the Y-12 National Security Complex Energy Management program support the Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) vision for a commitment to energy efficiency and sustainability and to achievement of the guiding principles. The site is diligently working toward establishing and prioritizing projects to reach the goals that Executive Orders 13514 and 13423 set forth. Y-12 is working to communicate its sustainment vision through procedural, engineering, operational, and management practices. The site will make informed decisions that are based on the application of the fi ve guiding principles for High Performance Sustainable Buildings (HPSBs) to the maximum extent possible. Current limitations in achievement of the goals lie in the existing Future Years National Security Program funding profiles. Y-12 will continue to execute energy projects as funding becomes available or as they can be accomplished incrementally within existing funding profiles. All efforts will be made to integrate energy initiatives with ongoing site mission objectives. Figures ES.1-ES.4 show some examples of sustainability activities at the Y-12 Complex.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Role of Occupant Behavior in Achieving Net Zero Energy: A Demonstration Project at Fort Carson

This study, sponsored by the U.S. General Services Administration’s Office of Federal High-Performance Green Buildings, aimed to understand the potential for institutional and behavioral change to enhance the performance of buildings, through a demonstration project with the Department of Defense in five green buildings on the Fort Carson, Colorado, Army base. To approach this study, the research team identified specific occupant behaviors that had the potential to save energy in each building, defined strategies that might effectively support behavior change, and implemented a coordinated set of actions during a three-month intervention.

Army↗

Best Practices for HPSB Guiding Principles Implementation in Existing DOE Buildings

The intent of this paper is to document an approach to screening existing buildings at DOE sites for High-Performance and Sustainable Buildings (HPSB) Guiding Principles (GPs) potential, developing policies and programs to address a majority of the HPSB GPs, and how to prioritize buildings with the greatest potential. This paper will also include example strategies for HPSB inventory and projection schedules and best practices on approaching and interpreting select criteria that have been troublesome to sites.

Henderson, Jordan W.↗

Evaluation of ANSI/ASHRAE/USGBC/IES Standard 189.1-2009

The National Renewable Energy Laboratory (NREL) evaluated ANSI/ASHRAE/USGBC/IES Standard 189.1-2009, 'The Standard for High-Performance Green Buildings Except Low-Rise Residential Buildings'. NREL performed this evaluation by examining the results of predictions for site energy use from a comprehensive set of EnergyPlus models. NREL has conducted an 'order-of-magnitude' analysis in this study toidentify the likely overall impact of adopting Standard 189.1-2009 over ANSI/ASHRAE/IESNA Standard 90.1-2007.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Outcomes from the DOE Workshop on Turbulent Flow Simulation at the Exascale

This paper summarizes the outcomes from the Turbulent Flow Simulation at the Exascale: Opportunities and Challenges Workshop, which was held 4-5 August 2015, and was sponsored by the U.S. Department of Energy Office of Advanced Scientific Computing Research. The workshop objective was to define and describe the challenges and opportunities that computing at the exascale will bring to turbulent-flow simulations in applied science and technology. The need for accurate simulation of turbulent flows is evident across the U.S. Department of Energy applied-science and engineering portfolios, including combustion, plasma physics, nuclear-reactor physics, wind energy, and atmospheric science. The workshop brought together experts in turbulent-flow simulation, computational mathematics, and high-performance computing. Building upon previous ASCR workshops on exascale computing, participants defined a research agenda and path forward that will enable scientists and engineers to continually leverage, engage, and direct advances in computational systems on the path to exascale computing.

97 MATHEMATICS AND COMPUTING↗