Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high field sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Detector arrays for photometric measurements at soft X-ray, ultraviolet and visible wavelengths

The construction and modes of operation of the Multi-Anode Microchannel Array (MAMA) detectors are described, and the designs of spectrometers utilizing them are outlined. MAMA consists of a curved microchannel array plate, an opaque photocathode (peak quantum efficiency of 19% at 1216 A), and a multi-anode (either discrete- or coincidence-anode) readout array. Designed for use in instruments on spaceborne telescopes, MAMA can be operated in a windowless configuration in extreme-ultraviolet and soft X-ray wavelengths, or in a sealed configuration at UV and visible wavelengths. Advantages of MAMA include low applied potential (less than 3.0 kV), high gain (greater than 10 to the 6th electrons/pulse), low sensitivity to high-energy charged particles, and immunity to external magnetic fields of less than 500 Gauss

Timothy, J. G.↗

Study of the effects of impurities on the properties of silicon materials and performance of silicon solar cell

The effect of silicon film thickness on the energy conversion efficiency of a back surface field solar cell is investigated. A computer-aided design study on the dependence of efficiency peaks on the concentrations of the recombination and dopant impurities is presented. The illuminated current voltage characteristics of over 100 cell designs were obtained using the transmission line circuit model to numerically solve the Shockley Equations. Using an AM1 efficiency of 17% as a target value, it is shown that the efficiency versus thickness dependence has a broad maximum which varies less than 1% over more than three-to-one range of cell thickness from 30 to 100 microns. Optical reflecting back surface will give only a slight improvement of AM1 efficiency, about 0.7%, in this thickness range. The sensitive dependence of efficiency on patchiness across the back surface field, low high junction in thin cells is noted.

Sah, C. T.↗

The interstellar carbon abundance. II - Rho Ophiuchi and Beta Scorpii

A procedure designed to obtain increased sensitivity from high-dispersion IUE spectra by using a flat-field spectrum to remove nonrandom noise due to the response pattern of the SEC vidicon detector is described. Application of this procedure to spectra of Rho Oph and Beta(1) Sco near the spin-forbidden interstellar 2325 line of C II yields 2 sigma upper limits on absorption of W (lambda) not greater than about 4 mA. The resulting depletion of carbon from the interstellar gas toward Rho Oph exceeds a factor of 1.4.

Welty, D. E.↗

Ultra-Stable Superconducting-Maser Oscillator

Unprecedented stability of frequency in superconducting, triple-cavity ruby maser oscillator achieved by incorporation of amplitude-control subsystem. New design enhances ultra-stable measurements of time by reducing fluctuations to 2 X 10 to negative 19th power routinely, and to as little as 10 to negative 20th power in exceptional cases. Currents induced in superconducting pickup coil by changes in magnetic field in ruby. Currents from coil fed to superconducting quantum-interference device (SQUID) magnetometer, output used to generate control signal for electronically variable attenuator. Attenuator varies pump-signal amplitude in response to magnetic-field fluctuations in ruby. Very high feedback-loop gain used for sensitivity of control and adequate compensation of fluctuations.

Strayer, Donald M.↗

Deformations and strains in a thick adherend lap joint

Displacement fields in a thick adherend lap joint were measured by high-sensitivity moire interferometry. Contour maps of in-plane U and V displacements were obtained across adhesive and adherend surfaces. Loads ranged from a modest load to a near-failure load. Quantitative results are given for displacements and strains in the adhesive and along the adhesive/adherend boundary lines. The results show nearly constant shear strain in the adhesive, nonlinear strains as a function of load or average shear stress, and viscoelastic or time-dependent response. Longitudinal normal strains in the adhesive are nearly two orders of magnitude less than the shear strains. With its subwavelength displacement resolution and high spatial resolution, moire interferometry is especially well suited for deformation studies of adhesive joints.

Post, D.↗

Noncontact charge measurement

A method for noncontact charge measurements is presented, which uses a system based on the reciprocal motion principle of a grounded conductor near a point charge. The system exhibits extremely good linearity with respect to the input electric field and has a resolution of greater than 10 V/m. The high sensitivity of the apparatus makes the system feasible for use at a safe distance in various applications for monitoring static charge.

Lin, Kuan-Chan↗

Replaceable Microfluidic Cartridges for a PCR Biosensor

The figure depicts a replaceable microfluidic cartridge that is a component of a miniature biosensor that detects target deoxyribonucleic acid (DNA) sequences. The biosensor utilizes (1) polymerase chain reactions (PCRs) to multiply the amount of DNA to be detected, (2) fluorogenic polynucleotide probe chemicals for labeling the target DNA sequences, and (3) a high-sensitivity epifluorescence-detection optoelectronic subsystem. Microfluidics is a relatively new field of device development in which one applies techniques for fabricating microelectromechanical systems (MEMS) to miniature systems for containing and/or moving fluids. Typically, microfluidic devices are microfabricated, variously, from silicon or polymers. The development of microfluidic devices for applications that involve PCR and fluorescence-based detection of PCR products poses special challenges

Francis, Kevin↗

Magnetometer Based on Optoelectronic Microwave Oscillator

proposed instrument, intended mainly for use as a magnetometer, would include an optoelectronic oscillator (OEO) stabilized by an atomic cell that could play the role of a magnetically tunable microwave filter. The microwave frequency would vary with the magnetic field in the cell, thereby providing an indication of the magnetic field. The proposed magnetometer would offer a combination of high accuracy and high sensitivity, characterized by flux densities of less than a picotesla. In comparison with prior magnetometers, the proposed magnetometer could, in principle, be constructed as a compact, lightweight instrument: It could fit into a package of about 10 by 10 by 10 cm and would have a mass <0.5 kg. As described in several prior NASA Tech Briefs articles, an OEO is a hybrid of photonic and electronic components that generates highly spectrally pure microwave radiation, and optical radiation modulated by the microwave radiation, through direct conversion between laser light and microwave radiation in an optoelectronic feedback loop. As used here, "atomic cell" signifies a cell containing a vapor, the constituent atoms of which can be made to undergo transitions between quantum states, denoted hyperfine levels, when excited by light in a suitable wavelength range. The laser light must be in this range. The energy difference between the hyperfine levels defines the microwave frequency. In the proposed instrument (see figure), light from a laser would be introduced into an electro-optical modulator (EOM). Amplitude-modulated light from the exit port of the EOM would pass through a fiber-optic splitter having two output branches. The light in one branch would be sent through an atomic cell to a photodiode. The light in the other branch would constitute the microwave-modulated optical output. Part of the light leaving the atomic cell could also be used to stabilize the laser at a frequency in the vicinity of the desired hyperfine or other quantum transition. The microwave signal from the output of the photodiode would be amplified (if necessary, as explained below) and fed back into the EOM. This system would oscillate if the amplification in the closed loop exceeded the linear absorption of the loop. The microwave amplifier may be unnecessary to sustain stable oscillations, depending on the power of the laser radiation at the photodetector and on particular features of the modulator and optical delay line.

Maleki, Lute↗

The Chandra Deep Wide-field Survey: A New Chandra Legacy Survey in the Bootes Field. I. X-ray Point Source Catalog, Number Counts, and Multiwavelength Counterparts

We present a new, ambitious survey performed with the Chandra X-ray Observatory of the 9.3 deg2 Boötes field of the NOAO Deep Wide-Field Survey. The wide field probes a statistically representative volume of the universe at high redshift. The Chandra Deep Wide-field Survey exploits the excellent sensitivity and angular resolution of Chandra over a wide area, combining 281 observations spanning 15 yr, for a total exposure time of 3.4 Ms, and detects 6891 X-ray point sources down to limiting fluxes of 4.7 × 10−16, 1.5 × 10−16, and 9 × 10−16 erg cm−2 s−1 in the 0.5–7, 0.5–2, and 2–7 keV bands, respectively. The robustness and reliability of the detection strategy are validated through extensive, state-of-the-art simulations of the whole field. Accurate number counts, in good agreement with previous X-ray surveys, are derived thanks to the uniquely large number of point sources detected, which resolve 65.0% ± 12.8% of the cosmic X-ray background between 0.5 and 2 keV and 81.0% ± 11.5% between 2 and 7 keV. Exploiting the wealth of multiwavelength data available on the field, we assign redshifts to ∼94% of the X-ray sources, estimate their obscuration, and derive absorption-corrected luminosities. We provide an electronic catalog containing all of the relevant quantities needed for future investigations.

Catalogs↗

STROBE-X: A Probe-Class Mission for X-Ray Spectroscopy and Timing on Timescales from Microseconds to Years

We describe the Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X), a probe-class mission concept that will provide an unprecedented view of the X-ray sky, performing timing and spectroscopy over both a broad energy band (0.2-30 keV) and a wide range of timescales from microseconds to years. STROBE-X comprises two narrow-field instruments and a wide field monitor. The soft or low-energy band (0.2-12 keV) is covered by an array of lightweight optics (3-m focal length) that concentrate incident photons onto small solid-state detectors with CCD-level (85-175 eV) energy resolution, 100 ns time resolution, and low background rates. This technology has been fully developed for NICER and will be scaled up to take advantage of the longer focal length of STROBE-X. The higher-energy band (2-30 keV) is covered by large-area, collimated silicon drift detectors that were developed for the European LOFT mission concept. Each instrument will provide an order of magnitude improvement in effective area over its predecessor (NICER in the soft band and RXTE in the hard band). Finally, STROBE-X offers a sensitive wide-field monitor (WFM), both to act as a trigger for pointed observations of X-ray transients and also to provide high duty-cycle, high time-resolution, and high spectral-resolution monitoring of the variable X-ray sky. The WFM will boast approximately 20 times the sensitivity of the RXTE All-Sky Monitor, enabling multi-wavelength and multi-messenger investigations with a large instantaneous field of view. This mission concept will be presented to the 2020 Decadal Survey for consideration.

Ray, Paul S.↗

Adaptive Scalpel Scanning Probe Microscopy for Enhanced Volumetric Sensing in Tomographic Analysis

Controlling nanoscale tip‐induced material removal is crucial for achieving atomic‐level precision in tomographic sensing with atomic force microscopy (AFM). While advances have enabled volumetric probing of conductive features with nanometer accuracy in solid‐state devices, materials, and photovoltaics, limitations in spatial resolution and volumetric sensitivity persist. This work identifies and addresses in‐plane and vertical tip‐sample junction leakage as sources of parasitic contrast in tomographic AFM, hindering real‐space 3D reconstructions. Novel strategies are proposed to overcome these limitations. First, the contrast mechanisms analyzing nanosized conductive features are explored when confining current collection purely to in‐plane transport, thus allowing reconstruction with a reduction in the overestimation of the lateral dimensions. Furthermore, an adaptive tip‐sample biasing scheme is demonstrated for the mitigation of a class of artefacts induced by the high electric field inside the thin oxide when volumetrically reduced. This significantly enhances vertical sensitivity by approaching the intrinsic limits set by quantum tunneling processes, allowing detailed depth analysis in thin dielectrics. The effectiveness of these methods is showcased in tomographic reconstructions of conductive filaments in valence change memory, highlighting the potential for application in nanoelectronics devices and bulk materials and unlocking new limits for tomographic AFM.

36 MATERIALS SCIENCE↗

Surface processing and discharge-conditioning of high voltage electrodes for the Ra EDM experiment

The Ra EDM experiment uses a pair of high voltage electrodes to search for the atomic electric dipole moment of 225 Ra. We use identical, plane–parallel electrodes with a primary high gradient surface of 200 mm 2 to generate reversible DC electric fields. Our statistical sensitivity is linearly proportional to the electric field strength in the electrode gap. We adapted surface decontamination and processing techniques from accelerator physics literature to chemical polish and clean a suite of newly fabricated large-grain niobium and grade-2 titanium electrodes. Three pairs of niobium electrodes and one pair of titanium electrodes were discharge-conditioned with a custom high voltage test station at electric field strengths as high as +52.5 kV/mm and –51.5 kV/mm over electrode gap sizes ranging from 0.4 mm to 2.5 mm. One pair of large-grain niobium electrodes was discharge-conditioned and validated to operate at ±20 kV/mm with steady-state leakage current ≤ 25 pA (1σ) and a polarity-averaged 98 ± 19 discharges per hour. These electrodes were installed in the Ra EDM experimental apparatus, replacing a copper electrode pair, and were revalidated to ±20 kV/mm. Here, the niobium electrodes perform at an electric field strength 3.1 times larger than the legacy copper electrodes and are ultimately limited by the maximum output of our 30 kV bipolar power supply.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the effects of hydrogen and dose rate sensitivity in CMOS and bipolar technologies

Low dose rate (LDR) and high dose rate (HDR) experiments on field-oxide-field-effect-transistors (FOXFETs) and gated lateral pnp (GLPNP) bipolar transistors indicate that there is a dose rate enhancement factor (EF) associated with radiation-induced degradation. This EF is also affect by the presence of hydrogen in the oxide. In this work, we developed a one dimensional (1-D) numerical calculations code to investigate the key mechanisms that describe the dose rate sensitivity and the effect of hydrogen on dose rate effects. We used a finite-difference methodology for the numerical calculations that allow for computing solutions for the densities of the mobile species as well as for the electrostatic potential at nodes contained within a mesh superimposed on the solution domain. Results from calculations of damage EF indicate that oxide thickness, distribution of hole traps and hole capture cross-section affect dose rate sensitivity. In addition, calculations show that molecular hydrogen cracking at positively charged defects may be a key reaction relating hydrogen and dose rate response. Comparison to experimental data on bipolar and CMOS devices results in good agreement with the dose rate calculations of interface trap buildup

Barnaby, Hugh↗

Field Sensitivity Analysis of Turbulence Model Parameters for Flow Over a Wing

Reynolds-averaged-Navier-Stokes (RANS) turbulence models are a critical tool in computational-fluid-dynamics simulations of aerodynamic systems, but simulation results can be highly sensitive to RANS-model parameter choices. Sensitivity analysis can be used to quantify these impacts, and the objective of this study is to demonstrate field sensitivity analysis with respect to ten parameters in the 2003 Menter shear-stress-transport (SST) turbulence model. Here, the analysis is demonstrated for an application relevant to wind energy, namely, flow over a NACA 0015 wing at 12 degree angle of attack and a Reynolds number of 1.5 x 10 6 . We quantify sensitivity using Sobol indices and the mean-squared gradient, which are estimated using polynomial chaos and active subspace models, respectively. Our results indicate that there are substantial spatial variations in parameter sensitivities, with different sets of most-sensitive parameters near the wing, as well as in the downstream wake, consistent with the physical interpretations of the turbulence model inputs. We show that, for this particular turbulence model and flow, simultaneous dimension reduction is possible across all quantities of interest, enabling efficient exploration of model outcomes. Ultimately, this analysis provides new insights into turbulence model parameter sensitivities in incompressible flows, and also demonstrates the implementation of field sensitivity analysis for applications relevant to aerodynamics simulations.

17 WIND ENERGY↗

Ferromagnetic gyroscopes for tests of fundamental physics

Abstract A ferromagnetic gyroscope (FG) is a ferromagnet whose angular momentum is dominated by electron spin polarization and that will process under the action of an external torque, such as that due to a magnetic field. Here we model and analyze FG dynamics and sensitivity, focusing on practical schemes for experimental realization. In the case of a freely floating FG, we model the transition from dynamics dominated by libration in relatively high externally applied magnetic fields, to those dominated by precession at relatively low applied fields. Measurement of the libration frequency enables in situ determination of the magnetic field and a technique to reduce the field below the threshold for which precession dominates the FG dynamics. We note that evidence of gyroscopic behavior is present even at magnetic fields much larger than the threshold field below which precession dominates. We also model the dynamics of an FG levitated above a type-I superconductor via the Meissner effect, and find that for FGs with dimensions larger than about 100 nm the observed precession frequency is reduced compared to that of a freely floating FG. This is due to an effect akin to negative feedback that arises from the distortion of the field from the FG by the superconductor. Finally we assess the sensitivity of an FG levitated above a type-I superconductor to exotic spin-dependent interactions under practical experimental conditions, demonstrating the potential of FGs for tests of fundamental physics.

Physics↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

Increasing the Stability of Deep Blue Phosphor‐Sensitized OLEDs Using the Polariton‐Enhanced Purcell Effect

Abstract The stability of efficient, deep blue organic light‐emitting diodes (OLEDs) remains a major challenge in the field of organic electronics. Poor device stability originates from the high probability for destructive non‐radiative triplet exciton annihilation events. Phosphor‐sensitized fluorescence (PSF) is proposed to achieve an efficient, deep blue color by energy transfer from phosphors to fluorophores. Recently, the polariton‐enhanced Purcell (PEP) effect is introduced to decrease the triplet radiative lifetime and density, resulting in an increase in blue phosphorescent OLED lifetime. Here, the PEP effect is introduced to enhance the stability of the PSF‐OLEDs. It is shown that the PEP effect increases all radiative decay rates of the phosphors and fluorophores, leading to a reduction in the triplet annihilation events. Using a Pt‐complex phosphor sensitizer and a so‐called multi‐resonance fluorescent emitter in a PEP cavity, a 3.1‐fold lifetime increase is observed at a current density ofJ= 10 mA cm −2 , reduced EQE roll‐off and deep blue color with Commission Internationale de l'Eclairage coordinates of (0.13, 0.09). The PEP effect maximally extends PSF‐OLED lifetimes in devices with the highest triplet‐to‐singlet energy transfer rates. Moreover, this work suggests that the benefits of PEPs apply to all triplet‐based OLEDs.

Chemistry↗

In-Flight Performance of the Polarization Modulator in the CLASP Rocket Experiment

We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman‐alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman‐alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non‐uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.

CLASP↗