Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating and cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Analysis of Heat Transfer from Local Heating and Cooling Sources at Cryogenic Temperatures

Understanding the dispersion of heat around a cryogenic fluid tank, specifically the interaction between the cryogenic fluid and the tank wall is critical in the analysis of long duration cryogen storage in microgravity. The heat transfer interaction between a cryogenic storage tank and heat sources from external spacecraft structures is also one of the many factors that determine how much heat enters a tank. Recent flight experiments with two-phase fluids have indicated that local concentrations of heat input (also known as “hot spots”) can cause unwanted affects including local boiling. Computational fluid dynamic (CFD) models can provide a detailed assessment of the heat transfer occurring across a cryogenic storage system. However, CFD modeling takes time to construct and run. A simpler approach that can act as initial guidance for later CFD modeling analyzes external “hot spots” as point or finite heat sources. A radial, finite element network or a local direct solution can effectively estimate the heat spread across a cryogenic storage tank by calculating the temperature and heat load as a function of distance from the heat source. This calculation accounts for the convective heat transfer between the cryogenic fluid and storage tank surface. Similar approaches can be used to determine the effectiveness of cooling from a cryocooler as a finite, local heat sink. This approach allows for quick approximations of the thermal map across a cryogenic tank as well as sensitivity analysis under a wide range of design parameters including gravitational fields as implied through natural convection coefficients.

Cryogenic Fluid Management↗

Preliminary studies on diversion and misuse for TRISO-fueled heat-pipe-cooled microreactors

Microreactors are being developed by multiple reactor designers to mass-produce nuclear facilities for worldwide deployment. Including microreactors in a country’s energy portfolio introduces new concerns for international safeguards regarding the number of reactor locations. Microreactors have smaller quantities of nuclear material compared to current light-water reactors, which makes diverting enough material for clandestine purposes difficult for a single reactor. Diversion or misuse of multiple microreactors to obtain a significant quantity introduces a new acquisition pathway. This work examines diversion and misuse scenarios for a realistic heat-pipe-cooled microreactor to understand how these scenarios would effect reactor operations to determine if monitoring key parameters could reduce the burden of inspection on monitoring agencies. Here, we determined misuse caused too drastic of an effect on core operations to be a valid acquisition pathway for the realistic heat-pipe-cooled microreactor. Diversion was explored across varying levels of severity, where potential diversion scenarios could yield one significant quantity of material from between six and eleven microreactors. Through examining the critical control drum angle, excess reactivity, control drum worth, and power distribution changes from nominal were detected over the operational lifetime, which could indicate a divergence from normal operations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Solar residential heating and cooling system

System has been placed in operation to verify technical feasibility of using solar energy to provide residential heating and cooling. Complete system analysis was performed to provide design information.

Melton, D. E.↗

Heating and cooling of the earth's plasma sheet

Magnetic-field models based on pressure equilibrium in the quiet magnetotail require nonadiabatic cooling of the plasma as it convects inward or a decrease of the flux tube content. Recent in situ observations of plasma density and temperature indicate that, during quiet convection, the flux tube content may actually increase. Thus the plasma must be cooled during quiet times. The earth plasma sheet is generally significantly hotter after the expansion phase of a substorm than before the plasma sheet thinning begins and cools during the recovery phase. Heating mechanisms such as reconnection, current sheet acceleration, plasma expansion, and resonant absorption of surface waves are discussed. It seems that all mechanisms are active, albeit in different regions of the plasma sheet. Near-earth tail signatures of substorms require local heating as well as a decrease of the flux tube content. It is shown that the resonant absorption of surface waves can provide both.

Goertz, C. K.↗

Aircraft electric motor having a stator heat pipe cooling scheme

Aircraft electric motors are described. The aircraft electric motors include a motor unit having a rotor and a stator, wherein the stator includes a plurality of windings and cooling channels arranged to provide cooling to the plurality of windings, a drive unit configured to drive operation of the motor unit, and a cooling system. The cooling system includes an oscillating heat pipe containing a first working fluid, wherein the oscillating heat pipe is arranged to pick up heat from at least one winding, the oscillating heat pipe having an evaporator section arranged in thermal contact with the at least one winding and a condenser section arranged away from the evaporator section and a heat pickup portion arranged to receive a second working fluid to remove heat from the condenser section of the oscillating heat pipe.

Saviers, Kimberly Rae↗

Solar heating and cooling system design and development

The progress of the program during the sixth program quarter is reported. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test. The William O'Brien single-family heating system was installed and is operational. The New Castle single-family heating residence is under construction. The Kansas University (KU) system is in the final design stages. The 25 ton cooling subsystem for KU is the debugging stage. Pressure drops that were greater than anticipated were encountered. The 3 ton simulation work is being finalized and the design parameters for the Rankine system were determined from simulation output.

Source record↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

The Solar Heating and Cooling Commercial Demonstration Program at Marshall Space Flight Center - Some problems and conclusions

The origin and evolution of the Solar Heating and Cooling Commercial Demonstration Program by the Department of Energy and the Marshall Space Flight Center activities supporting this program from its conception are defined and discussed. Problems are summarized in the design and financial areas. It is concluded that the program has significantly assisted the creation of a viable solar testing and cooling industry. The cost effective procedures evolving from the program are expected to make a major contribution to reducing the effective life cycle cost of solar installation.

Middleton, R. L.↗

Curve fits of predicted inviscid stagnation-point radiative heating rates, cooling factors, and shock standoff distances for hyperbolic earth entry

Curve-fit formulas are presented for the stagnation-point radiative heating rate, cooling factor, and shock standoff distance for inviscid flow over blunt bodies at conditions corresponding to high-speed earth entry. The data which were curve fitted were calculated by using a technique which utilizes a one-strip integral method and a detailed nongray radiation model to generate a radiatively coupled flow-field solution for air in chemical and local thermodynamic equilibrium. The range of free-stream parameters considered were altitudes from about 55 to 70 km and velocities from about 11 to 16 km.sec. Spherical bodies with nose radii from 30 to 450 cm and elliptical bodies with major-to-minor axis ratios of 2, 4, and 6 were treated. Powerlaw formulas are proposed and a least-squares logarithmic fit is used to evaluate the constants. It is shown that the data can be described in this manner with an average deviation of about 3 percent (or less) and a maximum deviation of about 10 percent (or less). The curve-fit formulas provide an effective and economic means for making preliminary design studies for situations involving high-speed earth entry.

Suttles, J. T.↗

Solar heating and cooling system design and development

The progress made in the manufacture, test, evaluation, installation, problem resolution, performance evaluation, and development of eight prototype solar heating and combined heating and cooling systems is described.

Source record↗

Transient motion of a confined rarefied gas due to wall heating or cooling

The direct Monte Carlo method is used to simulate the transient motion of a confined rarefied gas as a container wall is rapidly heated or cooled. Results show that, for the rapid wall temperature changes, the gas response is better measured by an acoustic, rather than conduction, timescale, with steady state conditions being achieved after about ten wave crossing times.

Wadsworth, Dean C.↗

Prototype solar heating and cooling systems including potable hot water

These combined quarterly reports summarize the activities from November 1977 through September 1978, and over the progress made in the development, delivery and support of two prototype solar heating and cooling systems including potable hot water. The system consists of the following subsystems: solar collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Source record↗

Adaptive shape control of wavefront-preserving X-ray mirrors with active cooling and heating

This article describes the development and testing of a novel, water cooled, active optic mirror system (called “REAL: Resistive Element Adjustable Length”) that combines cooling with applied auxiliary heating, tailored to the spatial distribution of the thermal load generated by the incident beam. This technique is theoretically capable of sub-nanometer surface figure error control even at high power density. Tests conducted in an optical metrology laboratory and at synchrotron X-ray beamlines showed the ability to maintain the mirror profile to the level needed for the next generation storage rings and FEL mirrors.

42 ENGINEERING↗

Waste-Heat-Driven Cooling Using Complex Compound Sorbents

Improved complex-compound sorption pumps are undergoing development for use as prime movers in heat-pump systems for cooling and dehumidification of habitats for humans on the Moon and for residential and commercial cooling on Earth. Among the advantages of sorption heat-pump systems are that they contain no moving parts except for check valves and they can be driven by heat from diverse sources: examples include waste heat from generation of electric power, solar heat, or heat from combustion of natural gas. The use of complex compound sorbents in cooling cycles is not new in itself: Marketing of residential refrigerators using SrCl2 was attempted in the 1920s and 30s and was abandoned because heat- and mass-transfer rates of the sorbents were too low. Addressing the issue that gave rise to the prior abandonment of complex compound sorption heat pumps, the primary accomplishment of the present development program thus far has been the characterization of many candidate sorption media, leading to large increases in achievable heat- and mass-transfer rates. In particular, two complex compounds (called "CC260-1260" and "CC260-2000") were found to be capable of functioning over the temperature range of interest for the lunar-habitat application and to offer heat- and mass-transfer rates and a temperature-lift capability adequate for that application. Regarding the temperature range: A heat pump based on either of these compounds is capable of providing a 95-K lift from a habitable temperature to a heat-rejection (radiator) temperature when driven by waste heat at an input temperature .500 K. Regarding the heat- and mass-transfer rates or, more precisely, the power densities made possible by these rates: Power densities observed in tests were 0.3 kilowatt of cooling per kilogram of sorbent and 2 kilowatts of heating per kilogram of sorbent. A prototype 1-kilowatt heat pump based on CC260-2000 has been built and demonstrated to function successfully.

Rocketfeller, Uwe↗