Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Lithium and potassium heat pipes for thermionic converters

A prototypic heat pipe system for an out-of-core thermionic reactor was built and tested. The emitter of the concentric thermionic converter consists of the condenser of a tungsten heat pipe utilizing a lithium working fluid. The evaporator section of the emitter heat pipe is radiation heated to simulate the thermal input from the nuclear reactor. The emitter heat pipe thermal transport is matched to the thermionic converter input requirement. The collector heat pipe of niobium, 1% zirconium alloy uses potassium as the working fluid. The thermionic collector is coupled to the heat pipe by a tapered conical joint designed to minimize the temperature drop. The collector heat flux matches the design requirements of the thermionic converter.

Miskolczy, G.↗

Lithium and potassium heat pipes for thermionic converters

A prototypic heat pipe system for an out-of-core thermionic reactor has been built and tested. The emitter of the concentric thermionic converter consists of the condenser of a tungsten heat pipe utilizing a lithium working fluid. The evaporator section of the emitter heat pipe is radiation heated to simulate the thermal input from the nuclear reactor. The emitter heat pipe thermal transport is matched to the thermionic converter input requirement. The collector heat pipe of niobium, 1%-zirconium alloy uses potassium as the working fluid. The thermionic collector is coupled to the heat pipe by a tapered conical joint designed to minimize the temperature drop. The area ratio of the evaporator to condenser is 16:1, which increases the radiation area. The composite wick structure consists of seven arteries and cylindrical wraps. The collector heat flux matches the design requirements of the thermionic converter.

Miskolczy, G.↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Improved Design Tools for Surface Water and Standing Column Well Heat Pump Systems (DE-EE0002961)

Ground-source heat pump (GSHP) systems are perhaps the most widely used “sustainable” heating and cooling systems, with an estimated 1.7 million installed units with total installed heating capacity on the order of 18 GW. They are widely used in residential, commercial, and institutional buildings. Standing column wells (SCW) are one form of ground heat exchanger that, under the right geological conditions, can provide excellent energy efficiency at a relatively low capital cost. Closed-loop surface water heat pump (SWHP) systems utilize surface water heat exchangers (SWHE) to reject or extract heat from nearby surface water bodies. For building near surface water bodies, these systems also offer a high degree of energy efficiency at a low capital cost. However, there have been few design tools available for properly sizing standing column wells or surface water heat exchangers. Nor have tools for analyzing the energy consumption and supporting economics-based design decisions been available. The main contributions of this project lie in providing new tools that support design and energy analysis. These include a design tool for sizing surface water heat exchangers, a design tool for sizing standing column wells, a new model of surface water heat pump systems implemented in EnergyPlus and a new model of standing column wells implemented in EnergyPlus. These tools will better help engineers design these systems and determine the economic and technical feasibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantity, Quality, and Availability of Waste Heat from United States Thermal Power Generation

Secondary application of unconverted heat produced during electric power generation has the potential to improve the life-cycle fuel efficiency of the electric power industry and the sectors it serves. Here this work quantifies the residual heat (also known as waste heat) generated by U.S. thermal power plants and assesses the intermittency and transport issues that must be considered when planning to utilize this heat. Combining Energy Information Administration plant-level data with literature-reported process efficiency data, we develop estimates of the unconverted heat flux from individual U.S. thermal power plants in 2012. Together these power plants discharged an estimated 18.9 billion GJ th of residual heat in 2012, 4% of which was discharged at temperatures greater than 90 °C. We also characterize the temperature, spatial distribution, and temporal availability of this residual heat at the plant level and model the implications for the technical and economic feasibility of its end use. Increased implementation of flue gas desulfurization technologies at coal-fired facilities and the higher quality heat generated in the exhaust of natural gas fuel cycles are expected to increase the availability of residual heat generated by 10.6% in 2040.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Solar energy workshop--Tucson, Arizona

Showplace for solar energy utilization includes complex solar heating and cooling system which supplies 95 percent of space heat requirements. Project utilized superior construction techniques and quality materials, and full time maintenance staff was assigned to keep systems operating.

Source record↗

Low-Cost Electrically-Heated Glass Panels

Inexpensive process converts architectural reflective-coated glass into electrically heated panels. Technique utilizes reflective layer as heating element in ordinary glass. Panels have many applications, including automobile windows, home-heating panels, temperature-controlled windows or containers, and food warming trays.

Shlichta, P. J.↗

Novel thin-film heat flux sensors

A new and simpler design for thin-film heat flux sensors for utilization in high heat flux environments is presented. The design of these sensors consists of a planar differential thermopile made up of a number of thermocouple pairs arranged in a circular array, two different thermal resistance layers deposited on the inside and outside junctions of the thermopile and a high emissivity coating. This design has shown good potential for measuring heat fluxes in severe environments of aerospace propulsion systems.

Bhatt, Hemanshu↗

Space vehicle thermal rejection system

A space vehicle thermal heat rejection system 10 utilizing separate optimized heat pipe components for the functions of heat acquisition, heat transport, and heat rejection. A honeycomb panel heat pipe evaporator section 20 performs the function of heat acquisition, and forms a closed thermodynamic system with a dual channel heat pipe transport section 30, which performs the function of heat transport. A plurality of truss or channel core heat pipe rejection fins 41 form the condenser section 40, which performs the function of heat rejection. A common wall 32 separates the condenser section 40 from the transport section 30. Using the above heat pipe components and having efficient interfacing between them results in high performance factors for the overall system.

Tanzer, Herbert J.↗

Conceptual System Design of a Supercritical CO{sub 2} cooled Micro Modular Reactor - 18492

Small modular reactor (SMR) concepts proposed in the past have compact size and a longer life reactor core than the conventional nuclear power plants. However, previous concepts based on the water-cooled technologies with a steam Rankine cycle have shown that the complete modularization is still technically challenging. This study suggests an innovative concept of a reactor directly cooled by supercritical carbon dioxide (S-CO{sub 2}) with S-CO{sub 2} Brayton cycle as a power conversion system, namely KAIST MMR (Micro Modular Reactor). To enhance neutron economy and maximize the fuel volume fraction of the core, a uranium carbide fuel controlled by drum type control rods was used in the fast-spectrum MMR. The core has long life (20 years) without refueling or reshuffling as well as inherent safety features. The reactor can be used as a distributed power source, and replace outdated fossil fuel power plants for small cities. Moreover, we propose a S-CO{sub 2} Brayton cycle as a power conversion system to achieve small, high performance and lightweight module. Thanks to the compact core and power conversion system, the entire system can be contained in a single module. The target of the system is to achieve small and compact system that can be transported via ground transportation of a single module containing the core and the power conversion system altogether. In order to meet this target single module s total weight is minimized in the order of 150 tons. The external size of a module is less than 7 m in length and 4 m in diameter. It produces 12 MWe electricity from 36 MWt reactor core. The S-CO{sub 2} Brayton cycle was optimized, and the cycle components were designed while maximizing the performance and minimizing the weight. A passive decay heat removal system utilizing shell and tube heat exchangers was also developed, and examined its performance with transient analysis code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The design of a solar energy collection system to augment heating and cooling for a commercial office building

Analytical studies supported by experimental testing indicate that solar energy can be utilized to heat and cool commercial buildings. In a 50,000 square foot one-story office building at the Langley Research Center, 15,000 square feet of solar collectors are designed to provide the energy required to supply 79 percent of the building heating needs and 52 percent of its cooling needs. The experience gained from the space program is providing the technology base for this project. Included are some of the analytical studies made to make the building design changes necessary to utilize solar energy, the basic solar collector design, collector efficiencies, and the integrated system design.

Basford, R. C.↗

Fundamental study of key issues related to advanced sCO 2 Brayton cycle: Prototypic HX development and cavitation

Diffusion bonded heat exchangers are the leading candidates for the sCO 2 Brayton cycles in next generation nuclear power plants. Commercially available diffusion bonded heat exchangers utilize set of continuous semi-circular zigzag micro channels to increase the heat transfer area and enhance heat transfer through increased turbulence production. Such heat exchangers can lead to excessive pressure drop as well as flow maldistribution in the case of poorly designed flow distribution headers. The goal of the current project is to fabricate and test potential discontinuous fin patterns for diffusion bonded heat exchangers; which can achieve desired thermal performance at lower pressure drops. Prototypic discontinuous offset rectangular and Airfoil fin surface geometries were chemically etched on to 316 stainless steel plate and sealed against an un-etched flat pate using O-ring seal emulating diffusion bonded heat exchangers. Thermal-hydraulic performance of these prototypic discontinuous fin geometries was experimentally evaluated and compared to the existing data for the continuous zigzag channels. The data generated from this project will serve as the database for future testing and validation of numerical models.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Biomass-Derived Distillate Fuel as Renewable Heating Oil

The utilization of advanced biofuels in stationary applications, such as home heating, is considered as an early entry point for biomass-derived fuels into the distillate fuel market sector. Two renewable fuels produced by a biomass fluidized catalytic cracking (BFCC) process, followed by hydroprocessing and fractionation, were tested. The evaluation was performed on a pure (100%) distillate fraction, 50% blend of the distillate fraction with petroleum-based heating oil, and 20% blend of a heavier gas oil fraction. Combustion experiments were carried out in a transparent quartz chamber and a typical oil-fired residential boiler. The flame stability, size, and shape produced by the fuels were examined. The flue gas was analyzed for O 2 , CO, NO x , and smoke. The elastomer compatibility test was performed with nitrile slabs at 43 °C for 1 month. Fuel stability was examined at 80 °C for 1 week. The results from the combustion studies suggest that the distillate fuel blends could be used as alternative fuels to No. 2 heating oil, even up to 100% without any operational issues. The distillate fuels were found to be stable. and the nitrile slab volume swell (~10%) suggests that the fuel could be compatible to legacy elastomers.

09 BIOMASS FUELS↗

High Performance Heat Pipe Power Transient Testing at SPHERE Facility

Microreactors are being researched, designed, and built at Idaho National Laboratory (INL). Microreactors are small reactors defined at less than 20MW of power. These reactor concepts are also being looked at throughout industry for various applications. An important aspect of these reactor designs is economic feasibility i.e. lower overnight capital cost. The driving factors for implementing microreactors are quick setup and takedown, minimal operators, and the ability to manufacture them readily and to fit in mid-sized containers for transport. A specific area of research to aid in successful integration of these factors within the designs is passive heat removal of the core’s thermal power. Interest in heat pipes to achieve this passive heat removal has been shown across multiple industry partners. Because of this interest, INL has developed a test facility to facilitate experimental tests for sodium filled heat pipes. INL has developed the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility to run experiments on high performance, sodium filled heat pipes. As mentioned above, heat pipes are passive heat transfer devices. Radially, heat pipes are broken up into an outer wall, a small annular gap, a wick structure, and a centerline gap. They function by utilizing latent heat transfer. Heat pipes are traditionally separated into three regions, an evaporator (heat input), an adiabatic region, and finally a condenser region (heat removal). As heat is being applied to the evaporator, the working fluid undergoes a phase change to a vapor. This phase change causes a differential pressure across the axial length of the pipe driving flow down the center gap of the heat pipe. The vapor flows down past the adiabatic region to the condenser where the heat is removed. This heat removal forces the working fluid to phase change back to a liquid. The wick structure is then utilized to drive the flow back towards the evaporator by capillary forces. This backflow is aided by the annular gap. Because this heat transfer mechanism functions with latent heat transfer, the heat pipe is close to isothermal down the axial length. Heat pipes can operate under a wide range of working fluids. Considerations for these working fluids are primarily driven by operating temperatures amongst other important factors based around overall performance. Sodium filled heat pipes operate from 450°C up to 900°C. This temperature range works well for the current microreactor designs. In conjunction with this experimental capability, INL has developed a modeling software to simulate heat pipe physics within reactor cores. This modeling software is called Sockeye and functions under the established INL Multiphysics Object Oriented Simulation Environment (MOOSE). SPHERE also supports Sockeye development by providing the modeling team with experimental data on an array of setups and operating parameters to support validation efforts. A power transient experiment was performed utilizing the SPHERE facility to continue to aid with Sockeye development. The testing followed a proposed test plan to ramp up and down the temperature of the heat pipe. Sockeye models steady state heat pipe operation with high accuracy, the data provided by the power transient testing aims to assist with the validation efforts and further enhance transient modeling capability of the tool [2].

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Treatment of Produced Water from Carbon Sequestration Sites for Water Reuse and Mineral Recovery

Southern Research along with Advanced Resources International, Inc. (ARI), Heartland Technology Partners, LLC (Heartland), New Logic Research, Inc. (New Logic), and Mr. Michael N. DiFilippo, Consultant developed a concept for an on-site strategy and design for management of produced water from CO 2 sequestration sites for maximum water reuse. When CO 2 is injected into deep saline aquifers, it may be necessary to produce water from the reservoir to reduce reservoir pressure. The New Logic Research, vibratory shear enhanced process (VSEP) membrane technology, and Heartland Technology Partners, low momentum-high turbulence (LM-HT) evaporation technology was selected for evaluation for treating this produced water from a 530 MW natural gas combined cycle (NGCC) power plant by utilizing waste heat from the plant to drive the evaporation process. The technology was also evaluated for application to a coal-fired power plant in lieu of the NGCC power plant. The results from the project show that the application of the proposed technology to the 530 MW NGCC power plant scenario could be feasible. The results indicate that formation water TDS has a very large impact on the technical and economic feasibility of the process. One advantage of formations with low TDS water is that the VSEP membrane can be utilized to pre-concentrate the produced water upstream of the LM-HT. The results indicate that a significant portion of the exhaust gas from the NGCC power plant will have to be utilized to provide waste heat for the LM-HT evaporator; however, less will be required with low-TDS formation water. The CAPEX costs for LM-HT for all three formations (97.8USD to 122.7USD MM/year) and VSEP plus LM-HT (106.6USD MM/year) for the Keg River formation is high in cost but lower than all technology compared including crystallization, VSEP plus crystallization, FO plus LM-HT, VCE plus LM-HT, and VCE plus crystallization. The OPEX for the LM-HT for all three formations (6.33USD to 7.97USD MM/year) and VSEP plus LM-HT (13.29USD MM/year) for the Keg River formation is lower than crystallization, VSEP plus crystallization, FO plus LM-HT, and FO plus crystallization. Only VCE plus LM-HT and VCE plus crystallization have a comparable OPEX costs to LM-HT for all three formation and VSEP plus LM-HT for the Keg River formation. The coal-fired power plant comparison showed that it is not feasible to apply the technology to that type of fossil fuel plant.

04 OIL SHALES AND TAR SANDS↗

Integrated hydrogen generator and compressor with related method

An integrated hydrogen generator and compressor (200) that includes a combined engine compressor (collectively 109, 110, 111) and steam-methane reformer (104) to produce high-pressure hydrogen from natural gas (methane). The reformer (104) combines methane, water, and heat under high pressure in the presence of an appropriate catalyst, to produce hydrogen utilizing waste heat from combustion cylinders of the combined engine compressor (collectively 109, 110, 111). Compression serves to pressurize two different gases (methane and hydrogen) in different compression cylinders including the compression cylinders (109a, 109b, 109c) of the combined engine compressor (collectively 109, 110, 111) alternatively and/or optionally combined with internal combustion engine (310) and/or gas compressor(s) (410) that are integrated thermally and via communication of compressed gases.

08 HYDROGEN↗

Unlocking the Path to Decarbonized Building Thermal Systems: Strategies for Designers and Contractors: Preprint

The design and construction community plays a pivotal role in facilitating the transition to decarbonized thermal systems that maintain human comfort while reducing building emissions. Through the U.S. Department of Energy Better Buildings initiative's Design and Construction Allies, a cohort of leading architecture, engineering, and construction firms have identified top ranked barriers that designers and contractors face when implementing solutions for building owners. These barriers to decarbonizing thermal - especially heating - systems include equipment availability; electrical capacity constraints; space allocations; complex system configurations; and lack of experience in designing, installing, and maintaining heat pumps. These impediments significantly amplify the risk and financial burden associated with the adoption of decarbonized solutions. The barriers also decrease the likelihood that designers, contractors, and owners will adopt decarbonization strategies without clear plans and guidance on how to implement these solutions, mitigate risk, and overcome the identified barriers. The National Renewable Energy Laboratory, the Design and Construction Allies, and the American Society of Heating, Refrigerating, and Air-Conditioning Engineers have developed "how to" thermal decarbonization guidance based on best practices. The subjects covered range from the role of energy efficiency in facilitating decarbonized heating solutions to strategies for decarbonizing new and existing heating, ventilating, and air-conditioning systems. The focus is on overcoming barriers so that energy-efficient, electrified buildings - both new and retrofit - become the industry standard. This paper outlines 1) the method used to collect and organize this guidance, 2) industry barriers to decarbonization, and 3) decarbonization techniques that have broad market applicability.

building heating↗

Current-Activated Reactive Ultrafast Joining (CARUJ)

We have demonstrated Current Activated Reactive Ultrafast Joining (CARUJ) as a novel approach for rapid fabrication of similar and dissimilar materials, such as ceramic-ceramic and ceramic-metal joint assemblies. The CARUJ technology utilizes resistive heating of carbon-based materials to apply localized heat at, (through or around) joint zones at rates of 10 1 -10 2 ˚C/min, enabling joining at time scales considerably shorter (several minutes as opposed to hours) than conventional approaches for similar systems. Herein, we present our findings while evaluating the CARUJ concept. Three methods of heat application were evaluated: (i) using carbon joule heating elements to apply heat directly through the joint interface; (ii) using flexible joule heating elements to locally apply heat around the assembly interface; and (iii) non-contact heating of the joint assembly using inductive power. Schemes (ii) and (iii) proved to be the most effective in producing mechanically sound reliable joints. We demonstrated single-step fabrication of dense SiC-SiC joints with a Si- SiC interface using minimal pressure (1–2 MPa) in under 30 minutes. Measured average joint strengths of about 15 MPa are initially achieved for joined bodies when tested in single lap offset (SLO) compressive shear, while tuning of the interfacial composition along with a reduction in interlayer thickness, results in improved joint strengths of approximately 43 MPa. We further demonstrated SiC-SiC joining using Active Brazing Alloys (ABAs) proof of concept joining of tubular geometries. The versatility of CARUJ is demonstrated by utilizing non-contact heating via induction, to join dissimilar materials systems of SiC, SS316 and MAX phase ceramics with ABA interlayers. The localized and rapid heat application realizes a versatile material joining technique that can be extended for joining components at the plant site.

36 MATERIALS SCIENCE↗