Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗

Optimizing Phase Change Composite Thermal Energy Storage Using the Thermal Ragone Framework

The thermal Ragone framework can be applied to the design of thermal energy storage heat exchangers to identifying relationships between their power requirements and energy capabilities. This presentation focuses on the design of planar thermal energy storage heat exchangers with phase change materials and thermal conductivity additives. Finite-difference models were used to optimize thermal storage heat exchanger designs focusing on key design parameters of conductivity additive volume fraction, spacing between tubes, and the phase transition temperatures. Design trends were developed for optimal designs based on varying thermal power requirements. To aid in future device design, models of reduced complexity were developed with the ability to predict optimal designs with computational speeds up to 5,000 times faster than finite-difference models.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Thermal Extraction and Delivery from Advanced Reactor Systems

This document presents preliminary thermodynamic analysis of thermal extraction and delivery from advanced nuclear reactors. Light-water, high temperature gas, sodium fast, and molten salt reactors are templated and analyzed for thermal extraction from nominal steam production conditions. Uncontrolled, controlled, and partial admission steam extraction methods are described and analyzed to show the differences in system impact from the various methods. Thermal delivery modeling results show comparisons that have become possible through the computational capabilities of the thermal delivery model. Due to the significant degrees of freedom of the problem, specific cases are used to compare the thermodynamic costs of heat transport using various heat transfer fluids. All this work is done using Modelica models, allowing for the future application of models in dynamic analyses beyond the steady-state calculations presented in this report. Appendices describe additional capabilities and methods that can help users analyze complex problems using HYBRID models developed in Modelica.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Investigation of a Phase Change Material Charged Finned-Tube Heat Exchanger

Understanding different thermal performance aspects of phase change material heat exchangers (PCM-HX) is critical for designing future energy-efficient thermal energy storage systems. This paper presents an experimental performance analysis of a vertically oriented annular finned-tube PCM-HX in a cylindrical container tested under six different melting and solidification test conditions, varied by heat transfer fluid’s (HTF) inlet temperatures and flow directions. The PCM-HX structure with 20 evenly spaced fins was 3D printed in aluminum, and the PCM-HX container was 285 mm in height. The PCM-HX average porosity was 89.7%, where the PCM mass was 246.4 g. Water served as the HTF, and a PCM with a nominal phase change temperature of 35 °C was selected. Instead of opaque conventional insulation sheets, a combination of air-and-argon-filled see-through insulation cylinders was assembled with the PCM-HX to visualize the phase-change phenomena, while minimizing the uncertainties due to heat loss. In total, there were 78 T-type thermocouples installed in the test section which allows a more precise assessment of thermal mass and heat loss, which are often neglected in similar studies found in the literature. We validated the reliability of the test facility as the repeated test results had negligible deviations under the same test conditions. The energy balances between the estimated theoretical and experimentally calculated PCM storage, considering heat loss and thermal mass, were within ±9% deviation for all test conditions. From the experimental investigations, we made several following observations. It was found that the melting pattern of the finned-tube PCM-HX with small gaps between the container wall and the fins was largely affected by the HTF flow directions, unlike the typical straight annular tube PCM-HX. For effective charging and discharging processes, a combination of upward melting and downward solidification is recommended to shorten the test duration. However, an upward solidification should be considered to minimize the cavity formation between the fins caused by the PCM volume contraction during the solidification process.

25 ENERGY STORAGE↗

NASA Tech Briefs, April 2012

Topics include: Computational Ghost Imaging for Remote Sensing; Digital Architecture for a Trace Gas Sensor Platform; Dispersed Fringe Sensing Analysis - DFSA; Indium Tin Oxide Resistor-Based Nitric Oxide Microsensors; Gas Composition Sensing Using Carbon Nanotube Arrays; Sensor for Boundary Shear Stress in Fluid Flow; Model-Based Method for Sensor Validation; Qualification of Engineering Camera for Long-Duration Deep Space Missions; Remotely Powered Reconfigurable Receiver for Extreme Environment Sensing Platforms; Bump Bonding Using Metal-Coated Carbon Nanotubes; In Situ Mosaic Brightness Correction; Simplex GPS and InSAR Inversion Software; Virtual Machine Language 2.1; Multi-Scale Three-Dimensional Variational Data Assimilation System for Coastal Ocean Prediction; Pandora Operation and Analysis Software; Fabrication of a Cryogenic Bias Filter for Ultrasensitive Focal Plane; Processing of Nanosensors Using a Sacrificial Template Approach; High-Temperature Shape Memory Polymers; Modular Flooring System; Non-Toxic, Low-Freezing, Drop-In Replacement Heat Transfer Fluids; Materials That Enhance Efficiency and Radiation Resistance of Solar Cells; Low-Cost, Rugged High-Vacuum System; Static Gas-Charging Plug; Floating Oil-Spill Containment Device; Stemless Ball Valve; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Oxygen-Methane Thruster; Lunar Navigation Determination System - LaNDS; Launch Method for Kites in Low-Wind or No-Wind Conditions; Supercritical CO2 Cleaning System for Planetary Protection and Contamination Control Applications; Design and Performance of a Wideband Radio Telescope; Finite Element Models for Electron Beam Freeform Fabrication Process Autonomous Information Unit for Fine-Grain Data Access Control and Information Protection in a Net-Centric System; Vehicle Detection for RCTA/ANS (Autonomous Navigation System); Image Mapping and Visual Attention on the Sensory Ego-Sphere; HyDE Framework for Stochastic and Hybrid Model-Based Diagnosis; and IMAGESEER - IMAGEs for Education and Research.

Source record↗

Parallel 3D Mortar Element Method for Adaptive Nonconforming Meshes

High order methods are frequently used in computational simulation for their high accuracy. An efficient way to avoid unnecessary computation in smooth regions of the solution is to use adaptive meshes which employ fine grids only in areas where they are needed. Nonconforming spectral elements allow the grid to be flexibly adjusted to satisfy the computational accuracy requirements. The method is suitable for computational simulations of unsteady problems with very disparate length scales or unsteady moving features, such as heat transfer, fluid dynamics or flame combustion. In this work, we select the Mark Element Method (MEM) to handle the non-conforming interfaces between elements. A new technique is introduced to efficiently implement MEM in 3-D nonconforming meshes. By introducing an "intermediate mortar", the proposed method decomposes the projection between 3-D elements and mortars into two steps. In each step, projection matrices derived in 2-D are used. The two-step method avoids explicitly forming/deriving large projection matrices for 3-D meshes, and also helps to simplify the implementation. This new technique can be used for both h- and p-type adaptation. This method is applied to an unsteady 3-D moving heat source problem. With our new MEM implementation, mesh adaptation is able to efficiently refine the grid near the heat source and coarsen the grid once the heat source passes. The savings in computational work resulting from the dynamic mesh adaptation is demonstrated by the reduction of the the number of elements used and CPU time spent. MEM and mesh adaptation, respectively, bring irregularity and dynamics to the computer memory access pattern. Hence, they provide a good way to gauge the performance of computer systems when running scientific applications whose memory access patterns are irregular and unpredictable. We select a 3-D moving heat source problem as the Unstructured Adaptive (UA) grid benchmark, a new component of the NAS Parallel Benchmarks (NPB). In this paper, we present some interesting performance results of ow OpenMP parallel implementation on different architectures such as the SGI Origin2000, SGI Altix, and Cray MTA-2.

Feng, Huiyu↗

Operational Modes of a 2.0 MWth Chloride Molten-Salt Pilot-Scale System

The limit of traditional solar-salt thermal stability is around 600 °C with ambient air as the cover gas. Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered to be state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. However, decomposition challenges occur with these salts for operation beyond 600 C. Although slightly higher limits may be possible with solar salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, molten-salt technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative salt chemistry composition, such as chlorides. In this investigation a 2.0MWth Pilot-scale CSP plant design is developed to assess thermodynamic performance potential for operation up to 720 C. Here, an Engineering Equation Solver (EES) model is developed with respect to 14 state-points from the base of a solar tower at the Sandia National Laboratories, National Solar Thermal Test Facility (NSTTF), to solar receiver mounted 120 ft. above the ground. The system design considers a ternary chloride ternary chloride (20%NaCl/40%MgCl/40%KCl by mol%) salt as the HTF, with 6 hrs. of storage and a 1 MWth primary salt to sCO2 heat exchanger. Preliminary system modelling results indicate a minimum non-dimensional Cv of 60 required for both cold and hot-side throttle recirculation valves for the operational pump operating between speeds of 1800 and 2400 RPM. Further receiver comparison study results suggest that the ternary salt requires an average 15.2% higher receiver flux with a slightly lower calculated receiver efficiency when compared to a binary carnelite salt to achieve a 2.0 MWth desired input power design.

associated liquids↗

Numerical Study and Validation of Melting and Solidification in PCM Embedded Heat Exchangers with Straight Tube

Latent heat thermal energy storage (LHTES) systems have shown great potential to enable reliable use of renewable energy and load shifting. LHTES offer high storage density and release energy at near constant temperature because of its use of phase change materials (PCMs). The cylindrical PCM heat exchangers (PCMHX) are one of the most used technologies due to their simplicity. Numerical models for such PCMHX enable engineers to estimate their performance for different design parameters and operating conditions without having to test them all. However, modeling the phase change phenomena can be challenging. To better understand the difficulties involving accurate modeling of PCMHX, a cylindrical latent storage unit filled with PCM and water as in-tube heat transfer fluid (HTF) is numerically investigated. This paper presents a study based on a 2D-axisymmetric model of a straight tube embedded in PCM in a cylindrical container. CFD is used to study the charging (melting) and discharging (solidification) phenomena. The models are validated against experimental and numerical data from the literature. The predicted local PCM temperature profile over time agrees within 2K compared to the experimental values. The paper also presents a simple method to estimate the melting and solidification phase change temperature range from limited data provided by PCM manufacturers.

PCM, melting, solidification, CFD, heat exchanger↗

Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

Enhancement of EM Pump Performance through Modeling and Testing

Liquid sodium has seen development as a nuclear reactor coolant in the United States for over 50 years. While sodium has many desirable characteristics as a heat transfer fluid, its reactivity poses numerous engineering challenges for even the most basic plant components like pumps. Despite the challenges, mechanical pumps have seen success in sodium service albeit at the expense of simplicity and flexibility. In fact, significant failures of these pumps have been recorded which can be attributed to their complexity. Notwithstanding the complexity, mechanical pumps are still widely proposed for the main circuit pump of sodium cooled reactors. However, an alternative to mechanical pumps are Electromagnetic Induction Pumps (EMIPs) which use the principle of the Lorentz Force. EMIPs avoid mechanically moving parts in contact with sodium which simplifies the design by avoiding mechanical wear and seals. Therefore, these pumps are generally safer and more reliable than their mechanical counterparts. That being said, EMIPs suffer from relatively low efficiencies that range from 5% to 45%. Some of the inefficiencies are inherent to the EMIPs pumps; namely, inefficiencies arise in the form of resistive heating losses in the fluid itself. However, other inefficiencies arise from Edge Effects which include Finite Length and Finite Width effects. Due to the significant safety advantages EMIPs have compared to mechanical pumps, there is a strong motivation to integrate these technologies into the design of Generation IV liquid-metal-cooled nuclear power plants. However, EMIPs have low efficiencies partly attributed to Edge Effects. Much of the literature focusing on Edge Effects is dated or simply does not exist in the public domain. More recently, numerical models of EMIPs have shown promising results. However, these models are often custom solvers or use complex software suits which limit their application. This report describes the work completed to understand Edge Effects in two EMIPs designs. These designs are the Annular Linear Induction Pump (ALIP) and Permanent Magnet Induction Pump (PMIP) also known as a Moving Magnet Pump (MMP). The methodology developed during this project aim at measuring key performance parameters (pressure-flowrate and efficiency-slip performance) using high temperature liquid-sodium. Baseline experimental measurements were then used to verify the accuracy of numerical models developed in the software suit ANSYS/FLUENT. On the experimental side, instrumentation was developed to characterize the pressure-flowrate and efficiency-slip performance of both the ALIP and PMIP in high-temperature liquid-sodium. Additionally, instrumentation was developed to measure potential output pressure pulsations and the magnetic field distributions. Moreover, a specialized ALIP was constructed to study the impacts magnetic field tapering, also known as coil grading, on the Finite Length Effect. Lastly, experimental performance curves of the PMIP were collected at 300 oC and 600 oC and compared to analytical theory which accounted for Finite Width Effects. These results showed that the Finite Width Effect and non-uniform magnetic field in a PMIP impact the performance. On the numerical side, models were developed using the software suit FLUENT/ANSYS. These methods were initially compared against a simple MHD flow in a Permanent Magnet Electromagnet Flowmeter (PMEMFM). The results were significant in that they showed agreeance between the numerical model and demonstrated that PMEMFM’s could be calibrated numerically. These modeling methods were then applied to a prototypic PMIP. Results showed that this simple model provided reasonably accurate results of the PMIP p-Q performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY↗

Hydrogen Mitigation Process Testing at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) developed and installed a process that addresses the issue of hydrogen buildup in Acciona's Nevada Solar One power plant. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 10 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Laboratory testing at NREL showed that the sensor function had an accuracy of +/-7%, and the hydrogen extraction rate for separator function was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP completed installation and initial testing of a mitigation process at ASP's Nevada Solar One power plant in Boulder City, Nevada. In this paper, we report on the completed installation, initial testing, and plans to bring the process to full automation, so that it can be operated unattended on a daily schedule.

chemical elements↗

Maglev Facility for Simulating Variable Gravity

An improved magnetic levitation apparatus ("Maglev Facility") has been built for use in experiments in which there are requirements to impose variable gravity (including zero gravity) in order to assess the effects of gravity or the absence thereof on physical and physiological processes. The apparatus is expected to be especially useful for experiments on the effects of gravity on convection, boiling, and heat transfer in fluids and for experiments on mice to gain understanding of bone loss induced in human astronauts by prolonged exposure to reduced gravity in space flight. The maglev principle employed by the apparatus is well established. Diamagnetic cryogenic fluids such as liquid helium have been magnetically levitated for studying their phase transitions and critical behaviors. Biological entities consist mostly of diamagnetic molecules (e.g., water molecules) and thus can be levitated by use of sufficiently strong magnetic fields having sufficiently strong vertical gradients. The heart of the present maglev apparatus is a vertically oriented superconducting solenoid electromagnet (see figure) that generates a static magnetic field of about 16 T with a vertical gradient sufficient for levitation of water in normal Earth gravity. The electromagnet is enclosed in a Dewar flask having a volume of 100 L that contains liquid helium to maintain superconductivity. The Dewar flask features a 66-mm-diameter warm bore, lying within the bore of the magnet, wherein experiments can be performed at room temperature. The warm bore is accessible from its top and bottom ends. The superconducting electromagnet is run in the persistent mode, in which the supercurrent and the magnetic field can be maintained for weeks with little decay, making this apparatus extremely cost and energy efficient to operate. In addition to water, this apparatus can levitate several common fluids: liquid hydrogen, liquid oxygen, methane, ammonia, sodium, and lithium, all of which are useful, variously, as rocket fuels or as working fluids for heat transfer devices. A drop of water 45 mm in diameter and a small laboratory mouse have been levitated in this apparatus.

Liu, Yuanming↗

Iron surface corrosion in supercritical CO2 at atomic scale investigated by molecular dynamics simulations

Understanding the corrosion behavior of steels in supercritical carbon dioxide (S-CO2) is essential for ensuring the safe application of S-CO2 as a heat-transfer fluid in high-temperature energy systems, including advanced nuclear reactors. In this work, molecular dynamics (MD) simulations using ReaxFF potential are performed to explore the atomic-scale corrosion mechanisms of body-centered cubic iron (BCC-Fe) in S-CO2. The results show that CO2 molecules in S-CO2 decompose at the Fe surface, generating free C and O atoms that form Fe-C and Fe-O bonds and subsequently produce oxides and carbides. Concurrently, Fe atoms dissolve from the surface and diffuse into the S-CO2 region, resulting in interdiffusion of Fe, C and O atoms at the interface. The corrosion-layer thickness calculations show that high pressure and temperature induced by S-CO2 have stronger effects than surface orientation on the corrosion process. In addition, surface Fe atoms undergo substantial displacement under S-CO2 exposure, further accelerating corrosion. When a radiation-induced void is introduced near the Fe surface, the corrosion is enhanced. The void-matrix interface expands the reaction surface area and simultaneously induces corrosion reactions inside the bulk, resulting in a deeper penetration of C and O and thicker corrosion layers. All these results indicate that high-temperature, high-pressure and radiation-induced voids can seriously affect the corrosion of Fe in S-CO2, and must be considered to better use S-CO2 in nuclear facilities.

Li, Wenhua↗

Optimization of a Packed Particle Magnetocaloric Refrigerator: A Combined Experimental and Theoretical Study

Magnetocaloric refrigeration has strong potential towards achieving high efficiency hydrogen liquefaction. Optimising parameters such as particle size and operating cycles can have a significant impact on liquefaction performance. Here, this work reports on a room temperature magnetocaloric refrigeration prototype designed with helium as the heat transfer fluid and packed particle Gd 0.8875 Ce 0.1025 Si 0.84 Cr 0.19 as the refrigerant. The temperature spans and cooling power with three different particle sizes at two different operating cycles were measured. A maximum temperature span of 16.7 K and a maximum cooling power of 8.6 W·kg –1 were obtained. Reduction of performance in the faster cycle was observed in larger particles due to insufficient thermal diffusion time and its implications for cryogenic temperatures are discussed. A numerical model was developed based on the experimentally observed variation of the temperature span and cooling power with particle size and cycle duration. This model was then used to study the competing effects of viscous dissipation and thermal diffusion for different particle sizes and cycle durations.

08 HYDROGEN↗

Performance Analyses of Supercritical Carbon Dioxide-Based Parabolic Trough Collectors with Double-Glazed Receivers

Supercritical carbon dioxide is becoming a hot research topic as a potential heat transfer fluid in parabolic trough concentrators since it enables operating the solar system at high temperatures for a higher quality of energy. However, the corresponding inflated thermal losses necessitate alternative receiver designs. This work examines four double-glazed receivers, with each annular space being evacuated or non-evacuated, in terms of the absorber tube's diameter (53-80 mm) and the diameter ratios of the two glass shells (1.2-2.0). An analytical model is developed and validated for this purpose, and the four designs are further examined using ground-level solar and meteorological measurements. The results demonstrate higher performance in the case of fully evacuating the receiver and using the smallest possible diameters of the three concentric cylinders, where the energy and exergy efficiencies reach 65.3 and 40.3%, respectively. Yet, evacuating only the inner annular space is sufficient to achieve virtually the same performance level. This energy efficiency decreases to 62% in case of increasing the tube diameter to 80 mm. As the operating temperature increases from 423 to 850 K, the specific thermal losses increase by 3.98-4.34 folds, depending on the receiver design. Double glazing the receivers is favorable only at high operating temperatures of sCO2, where the reduction in thermal losses overcomes the drop in optical efficiency. For an inlet sCO2 temperature of 850 K, thermal losses are reduced by 33.64 and 53.92%, compared to evacuated and non-evacuated single-glazed receivers, respectively. Throughout the year, the fully evacuated and fully non-evacuated double-glazed receivers have energy efficiencies of 54.96 and 52.39%, exergy efficiencies of 33.64 and 32.06%, and thermal losses of 348.8 and 402.5 W/m, respectively.

analytical model↗

Novel textured surfaces for superior corrosion mitigation in molten carbonate salts for concentrating solar power

Corrosion of metals in contact with molten salts used for thermal energy storage and heat transport at high temperatures is a serious impediment to the development of next-generation concentrating solar thermal systems. Toward addressing this limitation, novel multiscale fractal-textured Ni coatings on a variety of substrate alloys are presented in this study for exceptional corrosion mitigation in molten carbonate salts at a high temperature. Strongly adherent, durable, single-layer, and double-layer multiscale fractal coatings were fabricated using the electrodeposition method. Corrosion performance of the coatings on SS310, SS316, SS347, and In800H was studied in molten carbonate salt (32% Li 2 CO 3 +33% Na 2 CO 3 +35% K 2 CO 3 ) at 750 °C. Single-layer coatings are stable up to 300 h immersion, whereas double-layer coatings are stable beyond 750 h. The corrosion rate of double-layer Ni coatings on ferrous alloys was reduced by as much as 60% from that of uncoated surfaces and was about 18% below that of higher cost, high Ni content Ha230. The study represents the first-ever report of corrosion characteristics of alloys in carbonate salts at 750 °C and the first demonstration of a means of dramatically reducing corrosion in carbonate salts at a high temperature. The article is significant in that it provides a viable approach for low-cost structural alloys to be corrosion-resistant to molten carbonate heat transfer fluids and storage media in high-temperature concentrating solar thermal applications. Furthermore, the corrosion-resistant coatings provide opportunities for the use of low-cost, ferritic alloys instead of the expensive nickel-based alloys in practice.

14 SOLAR ENERGY↗

Electrodeposited nickel coatings for exceptional corrosion mitigation in industrial grade molten chloride salts for concentrating solar power

Molten chloride salt eutectics are attractive candidates for use as thermal energy storage media and heat transfer fluids in generation-three concentrating solar thermal power (Gen3 CSP) plants. However, corrosion of alloys in molten chloride salts, especially at high temperatures, is an extremely challenging problem that studies focus on lower temperatures, shorter durations, or analytical grade, and high-purity, salts. To date, there has been no study on corrosion or corrosion mitigation in an industrial-grade salt at a high temperature such as 750 °C. To alleviate this knowledge gap, the study presents new multiscale fractal-textured Ni coatings on various alloy surfaces for effective corrosion mitigation at 750 °C in molten chloride salts. Using the electrodeposition method, durable double-layer textured coatings were formed on stainless steel alloys (SS316, SS310, and SS347) and In800H. The corrosion performance of the coatings is investigated in both analytical-grade purity and, for the first time, practically relevant industrial-grade chloride salts. Ni-coated ferrous alloys showed an exceptionally reduced corrosion rate in the range of 350–480 μm/y in analytical-grade salts, and between 450 and 490 μm/y in purified industrial-grade salts at 750 °C. Ni coatings on ferrous alloys reduced corrosion rates by as much as 70% compared to uncoated surfaces and were comparable to the expensive Ha230 alloy with a high Ni content. As a result, by the use of innovative fractal corrosion mitigation coatings, for the first time, low-cost structural alloys are rendered viable for use with industrial-grade chloride salts, which is profoundly beneficial in practical systems.

14 SOLAR ENERGY↗