Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

BAYESIAN ANALYSIS OF MULTIPLE HARMONIC OSCILLATIONS IN THE SOLAR CORONA

The detection of multiple mode harmonic kink oscillations in coronal loops enables us to obtain information on coronal density stratification and magnetic field expansion using seismology inversion techniques. The inference is based on the measurement of the period ratio between the fundamental mode and the first overtone and theoretical results for the period ratio under the hypotheses of coronal density stratification and magnetic field expansion of the wave guide. We present a Bayesian analysis of multiple mode harmonic oscillations for the inversion of the density scale height and magnetic flux tube expansion under each of the hypotheses. The two models are then compared using a Bayesian model comparison scheme to assess how plausible each one is given our current state of knowledge.

79 ASTRONOMY AND ASTROPHYSICS↗

A Numerical Modelling Study on Submerged Condensers for Heat Pump Water Heaters Using Low-GWP Refrigerants

Challenges to global warming require reduction of GHG emissions, and increased use of renewable energy. Heat pumps extract energy from renewable sources and convert them to more useable forms for space conditioning, space heating and for water heating. They can be powered by renewable sources of electricity and must be engineered to use low global warming potentials (GWP) refrigerants (e.g., propane, GWP = 3) for a sustainable economy. Therefore, an electric heat pump water heaters (HPWH) using propane as refrigerant are developed in Oak Ridge National Laboratory to replace water heaters using all electric resistance and natural gas. A submerged condenser directly contacting with water is employed in the HPWH, which eliminates heat transfer barrier of the tank wall, and also prevents heat loss from the condenser tubes to the surrounding air. In present work, a numerical model is developed to model the submerged condenser. A dynamic temperature distribution on the condenser tubes from experimental data is applied to the model to enhance the accuracy of the numerical model. The model is essential to guide the design of the submerged condenser to achieve the performance required by the HPWH.

Zhang, Mingkan↗

Damage modeling of power tower receiver tubes using the SRLIFE tool

Concentrating Solar Power (CSP) molten-salt central receivers are subject to high, transient incident flux during daily operation. The resulting creep-fatigue damage impacts the receiver’s reliability and restricts the permissible incident flux distribution for a given receiver. This paper aims to reduce CSP plants’ levelized cost of electricity by developing a methodology to predict lifetime and identifies the primary damage mechanism (creep vs fatigue) for any given fluid temperature and temperature gradient. Results are presented in the form of a damage map that serves as a valuable operation guide and design tool. Damage maps can be used to reduce maintenance costs by improving reliability and reduce receiver capital costs by better utilizing the receiver area. FEA simulation and damage modeling of tubes subject to asymmetrical flux conditions is performed in the open-source receiver design tool srlife. Parametric studies are performed over a range of inner tube temperatures and thermal gradients for A230, 316H, 740H, A282, A617, and 800H high temperature alloys. Damage maps are presented for each alloy. A parametric, FEA-based methodology is presented for comparison of fatigue-creep ratios and prediction of tube lifetime based on the critical thermal operating conditions. Fatigue is found to be negligible compared to creep for almost every case. Here, this finding suggests that fatigue effects associated with cloud events are insignificant compared to creep at these high temperature operating conditions. Additionally, lifetime predictions identify thermal conditions where small changes in operating conditions can result in large changes in predicted lifetime.

14 SOLAR ENERGY↗

Developing a Prototype Methodology to Rank CO2-EOR Wells and Assess Their Reuse Potential for Geologic Carbon Storage

This paper presents a prototype methodology to assess the possible transition of Class II carbon dioxide-enhanced oil recovery (CO2-EOR) wells to Class VI wells. The focus is on wellbore construction materials—casing, cement, tubing, and the packer—and includes comprehensive workflows to evaluate these materials, with primary emphasis on compliance with Environmental Protection Agency (EPA) Class VI well construction and conversion guidelines. These workflows systematically assess material properties and performance criteria to ensure regulatory compliance and optimize long-term wellbore integrity and functionality. Utilizing Python scripts and JavaScript Object Notation (JSON) representations, the study automates checks on digitized Texas Railroad Commission (TRRC) data to rank wells based on workflow criteria. By emphasizing critical factors such as casing integrity, cementing techniques, tubing compatibility, and packer selection, the methodology helps well owners and operators prioritize wells for potential reuse as CO2 injection wells. Given limitations in digitized data, manual user verification is required in some sections. Future improvements include integrating non-digitized data through web scraping and machine learning techniques. This research serves as a practical guide for stakeholders, supporting environmental compliance and sustainable well operations.

geologic carbon sequestration↗

Silicon Carbide Multilayer Piping for High Temperature sCO 2 Brayton Cycle

Efficiencies of greater than 50% in supercritical carbon dioxide (sCO 2 ) Brayton power cycle systems can be achieved only at turbine inlet temperatures of above 700°C. In support of the push to higher temperatures, a finite element model was developed by Materials Research & Design, Inc. (MR&D) with support from Ceramic Tubular Products, LLC. (CTP) to guide the refinement of CTP’s high temperature ceramic multilayer piping. The multilayer technology combines the advantages of a monolithic silicon carbide (SiC) tube and a SiOC f /SiOC ceramic matrix composite (CMC), the result of which is a material with high-temperature strength and stability, high mechanical and thermal shock resistance, and high corrosion resistance. In addition to fabricating test specimens to refine the finite element model, long-duration, high temperature CO 2 exposure tests were performed by Sandia National Laboratories (SNL) on two varieties of inner monolithic SiC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental validation of shock propagation through a foam with engineered macro-pores

The engineered macro-pore foam provides a new way to study thermonuclear burn physics by utilizing capsules containing deuterated (D) foam and filling tritium (T) gas in the engineered macro-pores. The implosion of a thermonuclear capsule filled with an engineered macro-pore foam will be complex due to the interaction of a shock wave with the engineered macro-pores. It is our goal to quantify how substantially complex foam structures affect the shape of shock and bulk shock speed. A cylinder-shape shock tube experiment has been designed and performed at the Omega Laser Facility. In order to examine how a foam structure will affect shock propagation, we performed several tests varying (1) engineered macro-pore size, (2) average foam density, and (3) with/without neopentane (C 5 H 12 ) gas. X-ray radiographic data indicate that shock speed through engineered macro-pore foams depends strongly on average foam density and less on pore size. In this work, experimental shock propagation data helped guide two numerical simulation approaches: (1) a 2D simulation with homogenizing foams rather than explicitly simulating engineered macro-pores and (2) a 2D toroidal-pore approximation adopting a toroidal-tube geometry to model engineered macro-pores.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polysiloxane coatings on microspheres based on Multiphase Flow with Interface Exchange-Discrete Element Modelling

Polysiloxane coatings on yttria stabilized zirconia (YSZ) microspheres of 500 μm were simulated in a spout fluidized bed coater using Multiphase Flow with Interface Exchange-Discrete Element Modelling (MFiX-DEM). In this work, two different coater configurations were developed to study the influence of gas velocity and its distribution on particle dynamics. The presence of the Wurster tube not only enhances the distribution but also increases the overall residence time of the particles. Investigations were also carried out with different Wurster tube positions (normal, 10% and 20% lowered from its initial position). Among these, 20% lowered Wurster tube position demonstrated the most effective coating process. The effects of gas inlet pressure on the average gas velocity and the distribution of particles were analyzed. More than 97% of the particles can be retained. The derived results, including average gas velocity, particle retention percentage, and distribution of particles with gas velocity, are being used to guide the experimental work in obtaining defect-free coatings for YSZ microspheres.

36 MATERIALS SCIENCE↗

LAMP Technical Readiness Evaluation Report (Rev. 1)

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed. Corresponding Technical Readiness Levels (TRLs) were also determined for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Only two subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗

Magnetic Particle Imaging Guided Real-Time Percutaneous Transluminal Angioplasty in a Phantom Model

PurposeTo investigate the potential of real-time magnetic particle imaging (MPI) to guide percutaneous transluminal angioplasty (PTA) of vascular stenoses in a phantom model.Materials and MethodsExperiments were conducted on a custom-built MPI scanner. Vascular stenosis phantoms consisted of polyvinyl chloride tubes (inner diameter 8 mm) prepared with a centrally aligned cable tie to form ~ 50% stenoses. MPI angiography for visualization of stenoses was performed using the superparamagnetic iron oxide nanoparticle-based contrast agent Ferucarbotran (10 mmol (Fe)/l). Balloon catheters and guidewires for PTA were visualized using custom-made lacquer markers based on Ferucarbotran. Stenosis dilation (n = 3) was performed by manually inflating the PTA balloon with diluted Ferucarbotran. An online reconstruction framework was implemented for real-time imaging with very short latency time.ResultsVisualization of stenosis phantoms and guidance of interventional instruments in real-time (4 frames/s, ~ 100 ms latency time) was possible using an online reconstruction algorithm. Labeling of guidewires and balloon catheters allowed for precise visualization of instrument positions.ConclusionReal-time MPI-guided PTA in a phantom model is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trailer shield assembly for a welding torch

This invention relates generally to trailer shields for gas shielded arc welding torches, and more particularly to a trailer shield assembly provided with a shield gas manifold for providing an even dispersion of shield gas to the interior of the shield assembly, which generally encloses a joint being welded and a welding trailing portion of hot welded metal. The novelty of the invention lies in providing trailer shield with a manifold tube having a plurality of openings from which shield gas is distributed. A gas manifold region ahead of the torch is also provided with shield gas from a tube to protect metal preheated by the torch. Further novelty lies in constructing portions of sides and housing and portions of side walls of the guide of stainless steel screen having a tight mesh.

Dyer, Gerald E.↗

Influence of oblique magnetic field on electron cross-field transport in a Hall effect thruster

The effects of the inclination of the magnetic field with respect to the channel walls in a Hall effect thruster are numerically studied with the use of a one-dimensional quasi-neutral Particle-In-Cell model with guiding center approximation of electron motion along magnetic lines. Parametric studies suggest that the incidence angle strongly influences electron transport across the magnetic field. In ion-focusing magnetic topologies, electrons collide predominantly on the side of the magnetic flux tube closer to the anode, thus increasing the electron cross-field drift. The opposite effect is observed in ion-defocussing topology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Momentum Users Guide

Momentum is software, written Mark Smith-Nelson, to analyze neutron list-mode data. It contains some features specific to the MC-15 and NPOD neutron multiplicity counters. The MC-15 contains 15 3 He tubes and electronics for recording, in list mode, the time and tube number for each neutron detection. The data depends on many different parameters, including the source material type, source mass and enrichment, alpha ratio, detection efficiency, and multiplication. If some minimum number of these parameters is known, then Momentum can be used to calculate the remaining parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guide for extrusion dies eliminates straightening operation

To prevent distortion of extruded metal, a guidance assembly is aligned with the die. As the metal emerges from the extrusion dies, it passes directly into the receiver and straightening tube system, and the completed extrusion is withdrawn.

Gyorgak, C. A.↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

SU-E-J-56: Static Gantry Digital Tomosynthesis From the Beam’s-Eye-View

Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beam CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L. Partain, J. Kwon, D. Boyd: NIH/SBIR R43CA192489-01. J. Rottmann, G. Zentai, R. Berbeco: NIH/NCI 1R01CA188446-01. R. Berbeco: E. Research Grant, Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Efficacy of Lower-Body Shielding in Computed Tomography Fluoroscopy-Guided Interventions

Purpose: Computed tomography (CT) fluoroscopy-guided interventions pose relevant radiation exposure to the interventionalist. The goal of this study was to analyze the efficacy of lower-body shielding as a simple structural method for decreasing radiation dose to the interventionalist without limiting access to the patient. Material and Methods: All examinations were performed with a 128-slice dual source CT scanner (12 Multiplication-Sign 1.2-mm collimation; 120 kV; and 20, 40, 60, and 80 mAs) and an Alderson-Rando phantom. Scatter radiation was measured with an ionization chamber and a digital dosimeter at standardized positions and heights with and without a lower-body lead shield (0.5-mm lead equivalent; Kenex, Harlow, UK). Dose decreases were computed for the different points of measurement. Results: On average, lower-body shielding decreased scatter radiation by 38.2% within a 150-cm radius around the shielding. This decrease is most significant close to the gantry opening and at low heights of 50 and 100 cm above the floor with a maximum decrease of scatter radiation of 95.9% close to the scanner's isocentre. With increasing distance to the gantry opening, the effect decreased. There is almost no dose decrease effect at {>=}150 above the floor. Scatter radiation and its decrease were linearly correlated with the tube current-time product (r{sup 2} = 0.99), whereas percent scatter radiation decrease was independent of the tube current-time product. Conclusion: Lower-body shielding is an effective way to decrease radiation exposure to the interventionalist and should routinely be used in CT fluoroscopy-guided interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging

Purpose: The purpose of this study is to develop a single-shot version of the grating-based phase contrast x-ray imaging method and demonstrate its capability of in vivo animal imaging. Here, the authors describe the principle and experimental results. They show the source of artifacts in the phase contrast signal and optimal designs that minimize them. They also discuss its current limitations and ways to overcome them. Methods: A single lead grid was inserted midway between an x-ray tube and an x-ray camera in the planar radiography setting. The grid acted as a transmission grating and cast periodic dark fringes on the camera. The camera had sufficient spatial resolution to resolve the fringes. Refraction and diffraction in the imaged object manifested as position shifts and amplitude attenuation of the fringes, respectively. In order to quantify these changes precisely without imposing a fixed geometric relationship between the camera pixel array and the fringes, a spatial harmonic method in the Fourier domain was developed. The level of the differential phase (refraction) contrast as a function of hardware specifications and device geometry was derived and used to guide the optimal placement of the grid and object. Both ex vivo and in vivo images of rodent extremities were collected to demonstrate the capability of the method. The exposure time using a 50 W tube was 28 s. Results: Differential phase contrast images of glass beads acquired at various grid and object positions confirmed theoretical predictions of how phase contrast and extraneous artifacts vary with the device geometry. In anesthetized rats, a single exposure yielded artifact-free images of absorption, differential phase contrast, and diffraction. Differential phase contrast was strongest at bone-soft tissue interfaces, while diffraction was strongest in bone. Conclusions: The spatial harmonic method allowed us to obtain absorption, differential phase contrast, and diffraction images, all from a single raw image and is feasible in live animals. Because the sensitivity of the method scales with the density of the gratings, custom microfabricated gratings should be superior to off-the-shelf lead grids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗