Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid upgrades”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Environmental life cycle assessment of treatment and management strategies for food waste and sewage sludge

A consequential life cycle assessment (LCA) was utilized to compare the environmental impacts of food waste and sewage sludge management strategies. The strategies included a novel two-phase anaerobic digestion (AD) system and alternatives including landfill, waste-to-energy, composting, anaerobic membrane bioreactor, and conventional AD (wet continuous stirred-tank reactor [CSTR]). The co-management of food waste with sewage sludge was also considered for the two-phase AD system and for a conventional AD reactor. Further, a multidimensional LCA approach was taken, considering the five-midpoint impact categories of global warming, smog, human health particulate, acidification, and eutrophication estimated using the U.S. EPA Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts. Co-management of food waste and sewage sludge using the novel two-phase AD system was shown to maximize energy recovery and had a net global warming benefit while reducing other environmental impacts compared with the alternative management strategies. It had similar relative environmental advantages across all categories as conventional AD, with the advantage of a smaller physical footprint. However, both approaches featured net environmental burdens when the background electric grid intensity fell below 0.25 kg CO 2 -eq kWh -1 , as could be expected in a decarbonized electric future. Upgrading the biogas produced from AD to renewable natural gas can displace the use of fossil natural gas for other non-electricity energy requirements that are difficult to decarbonize and may extend the time period of significant environmental benefits of utilizing AD for organic waste management. Treatment of the nutrient-rich supernatant generated by the novel two-phase AD system could be an obstacle for utilities with stringent nutrient discharge limits. Future research and full-scale implementation are needed to demonstrate the benefits of the two-phase AD system predicted through this analysis.

54 ENVIRONMENTAL SCIENCES↗

Planning for Resilient Power Distribution Systems using Risk-Based Quantification and Q-Learning

Grid hardening is one of the most effective approaches that reduce the component failures and restoration efforts thus increasing the resilience of the power systems against extreme events. However, hardening and upgrading the entire system is prohibitively expensive and hence the optimal design of a distribution network is challenging. This paper adopted a reinforcement learning algorithm to identify the optimal hardening strategy to enhance the resilience of power distribution systems. Adopting the Q-learning algorithm as the reinforcement learning technique, we found the sequential optimal action for hardening measures to enhance the grid's resilience for the given budget. To identify the optimal strategy through Q-learning, Conditional Value at Risk (CVaR) is used as a rewarding metric. A study on the IEEE 123-bus test feeder validate the effectiveness of the proposed model and show how to effectively allocate budget limited resources to plan a resilient power distribution network.

Paul, Shuva↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Generator Interconnection Cost Analysis in the Midcontinent Independent System Operator (MISO) territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data from interconnection studies for the Midcontinent Independent System Operator (MISO), representing nearly 50% of all projects requesting interconnection from 2010 to 2020. Project-level cost summary data are available for download on this page. We find: -Average interconnection costs have grown as the number of interconnection requests have escalated -Projects that have completed all required interconnection studies have the lowest cost compared to applicants still actively working through the interconnection process or those that have withdrawn. -Broader network upgrade costs are the primary driver of recent cost increase. -Potential interconnection costs for wind, storage, and solar are larger than for natural gas -Larger generators have greater interconnection costs in absolute terms, but economies of scale exist on a per kW basis. -Interconnection costs vary by location Berkeley Lab will publish a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Interconnection Cost Analysis in the PJM Territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data from interconnection studies for the PJM Territory, representing nearly 86% of all new unique generators requesting interconnection from 2000 to 2022. Project-level cost summary data are available for download on this page. We find: -Average interconnection costs have grown as the number of interconnection requests have escalated -Projects that have completed all required interconnection studies have the lowest cost compared to applicants still actively working through the interconnection process or those that have withdrawn. -Broader network upgrade costs are the primary driver of recent cost increase. -Potential interconnection costs for wind, storage, and solar are larger than for natural gas -Larger generators have greater interconnection costs in absolute terms, but economies of scale exist on a per kW basis. -Interconnection costs vary by location Berkeley Lab will publish a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generator Interconnection Cost Analysis in the Southwest Power Pool (SPP) Territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data for 845 projects from interconnection studies for the Southwest Power Pool (SPP) Territory. The studies were performed between 2002 and 2023 and include all of the most refined cost estimates available. Project-level cost summary data are available for download on this page. We find: -Project-specific interconnection costs can differ widely. -Average interconnection costs are stable for projects that complete all interconnection studies but have escalated for those that withdraw. -Broader network upgrade costs are the primary driver of recent cost increases, especially for withdrawn projects. -Potential interconnection costs of all solar and wind requests have been greater than those of storage and natural gas projects. -Economies of scale exist for completed wind and solar projects but not for other fuel types or withdrawn projects. -Interconnection costs vary by location. Berkeley Lab publishes a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interconnection Cost Analysis in ISO-New England

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data for 194 projects in New England from interconnection studies performed between 2010 and 2021. Project-level cost summary data are available for download on this page. We find: -Interconnection costs have grown over time, especially for projects that withdraw. -Interconnection costs are highest for onshore wind, followed by solar and storage. Natural gas and offshore wind projects tend to cost less to interconnect, in comparison. -Economies of scale exist for solar and possibly storage projects, but not for other resource types. -Wind and solar projects requesting capacity network resource interconnection service have higher interconnection costs, despite being evaluated using the same interconnection standard in the analyzed studies. -Low and high interconnection costs can be found throughout the ISO-NE footprint. -Costs are split fairly evenly between investments at the point of interconnection and within the broader network for active and withdrawn projects, while complete projects incur most costs at the point of interconnection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Editorial: Advanced water splitting technologies development: Best practices and protocols

As the level of deployment and utilization of renewable energy sources, including wind and solar, continues to rise, large-scale, long-term energy storage technologies that could accommodate weekly and seasonal energy fluctuations will play a significant role in the overall deployment of renewable energies in the future. Harnessing and storing renewable energy resources via electrochemical, photoelectrochemical, or thermochemical processes by converting renewable energy into sustainable (energy storage) fuels have the potential to meet the long-term, terawatt scale energy storage challenge. Renewable hydrogen production is the cornerstone for sustainable fuel production and deep decarbonization of multiple sectors in our society. Cost-competitive clean hydrogen provides value to applications, such as 1) in the transportation sector for fuel cell vehicles, 2) in the electric grid sector for system stability and load balancing, and 3) in the industrial sector with metal refineries, cement production, and biomass upgrading (carbon-free fertilizer production). In addition, coupling clean renewable hydrogen with the carbon and nitrogen cycles enables known and well-established thermal-chemical processes to generate renewable hydrocarbon fuels and ammonia. The Advanced Water Splitting Technologies (AWST): low temperature electrolysis (LTE), high temperature electrolysis (HTE), photoelectrochemical (PEC) and solar thermo-chemical hydrogen (STCH) provide four unique and parallel approaches to produce low cost, low greenhouse gas (GHG) emission hydrogen at scale (Figure 1). Cost competitive clean hydrogen production using these four technologies is a current high priority focus for governments and industry. In June of 2022, the U.S. Department of Energy (DOE) launched the first in a series of Earthshot Initiatives. The Hydrogen Shot, “1 1 1” aims to reduce the cost of clean hydrogen by more than 80% to one dollar per one kilogram in 1 decade ($\$$1/kg H 2 ). The European Green Deal and the International Energy Agency (IEA) have implemented a strong focus on green hydrogen production for a clean and secure energy future.

benchmarking, low temperature electrolysis↗

The Future of Zero Energy Buildings: Produce, Respond, Regenerate: Preprint

The zero energy buildings concept is more than 20 years old, and the paradigm shift from buildings as energy consumers to buildings as energy producers is underway. Buildings also consume land and material resources, however, with attendant environmental impacts. Another paradigm is emerging: a built environment that produces energy and is environmentally responsive and regenerative. This paper investigates an updated framework for thinking about zero energy buildings that includes discussions of prioritizing renewables; determining on-site versus off-site generation; exploring how and when buildings should use energy; and balancing renewables, storage, and energy efficiency. Buildings are typically connected to the utility grid and the utility grid develops largely in response to the built environment. If more buildings’ real time electricity use aligned with renewable generation, more renewables would be added to the grid. Ultimately, the goal for zero energy buildings will be to use 100% renewables, 100% of the time, matching loads with energy storage and renewable generation at each discrete timestep over a year. This target is beyond the current zero energy definitions, which focus on an annual balance of renewable supply and energy demand and use the grid to “store” excess production to make up for hours without sufficient on-site renewable generation. This paper expands this upgraded concept and outlines simple metrics to evaluate the alignment of renewable sources and storage with building loads. This process can provide insights on building design considerations, including the use of flexible loads and optimal resource management.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Achieving American Leadership in the Hydropower Supply Chain

In 2020, hydropower accounted for 36.7% of U.S. renewable electricity generation and 7.3% of total electricity generation. While the existing U.S. supply chain effectively supports the nation’s hydropower fleet—the fourth-largest in the world, alongside the third-largest pumped storage hydropower (PSH) fleet—refurbishments, upgrades, and new development are required to modernize and expand the fleet and facilitate a clean, emissions-free U.S. electricity grid by 2035. To achieve these goals, researchers compiled a report examining the U.S. hydropower energy supply chain, including raw materials, processed materials, components, subcomponents, and recycling.

Source record↗

Grid Utility Asset Vulnerability Assessment (GUAVA) Software Tool

Increasing demand and changes in generation portfolios is pushing power grid to operate towards the limit. However, due to lack of analytical tools for understanding various scales of impact on grid, it is becoming more vulnerable to wide scale power outages and blackouts. A vulnerable grid operating at its limit can be easily disrupted by asset failures caused by devastating hurricanes which has been known to damage transmission and distribution lines along its track. In this direction, researchers have focused on determining these assets by conducting Monte Carlo simulations of hurricanes with uncertainties and collected a large set of simulation data. To determine the infrastructure updates necessary for mitigating wide scale impact of hurricanes on the grid, we propose a software tool named “Grid Utility Asset Vulnerability Analysis” (GUAVA) framework. GUAVA presents a novel data-driven probabilistic analytical approach to (1) post-process hurricane failure scenarios, (2) identify/rank assets that are most vulnerable and critical to failing and are associated with highest impact/risk, and (3) to inform system upgrade decisions & prioritization. Based on the observed results and employed data-driven methodology, it is expected GUAVA can be adapted to provide power system planners with a recommendation engine for making informed decisions to improve resilience of grid.

Mahapatra, Kaveri↗

U.S. IMERG Status

The U.S. Science Team’s Integrated Multi-satellitE Retrievals for the Global Precipitation Measurement (GPM) mission (IMERG) product provides estimates of surface precipitation rate and related information on a global 0.1° half-hour grid. It is run three times at increasingly longer latency and higher information input to serve different communities. This presentation will briefly summarize the major upgrades included in Version 07. The Goddard Profiling (GPROF) algorithm (applied to passive microwave sensor data from the GPM virtual constellation) and the Combined Radar-Radiometer Algorithm (CORRA) that provide input to IMERG V07 are both improved, and the new Precipitation Estimation from Remotely Sensed Information Using Artificial Neural Networks–Dynamic Infrared Rain Rate (PDIR) algorithm is being applied to infrared data, which employs an additional, warmer infrared temperature threshold than the previous infrared scheme and a deep neural network. V07 has improved bias performance as a result of calibrations that now employ the entire swath widths of CORRA and GPROF GPM Microwave Imager precipitation estimates. As well, time continuity in precipitation features is improved as a result of changes to the Kalman filter that approximately preserve the local histogram of precipitation rates (Scheme for Histogram Adjustment with Ranked Precipitation Estimates in the Neighborhood, or SHARPEN), and that better account for differences in sensor performance. A long-standing bug in the geolocation that shifted grid values 0.1° to the east in the latitude band 70°N-S has been corrected. Other changes in V07 include a hierarchical selection among motion vector sources to address deficiencies in the precipitation propagation near orography, an update to the precipitation phase specification for improved consistency with current inputs, and a renewed effort to implement climatological gauge adjustment to the near-real-time Runs. Early evaluations of V07 IMERG show interesting behavior across the TRMM orbit boost that is highly relevant to the planned orbit boost for the GPM Core observatory.

GPM↗

Strategies for Flood Resilience and Grid Investment Among Iowa's Electric Distribution Utilities

Flooding poses a growing threat to Iowa's electric distribution system, yet utilities face significant data and modeling challenges in planning effective resilience investments. This report provides a foundational assessment of how distribution utilities in Iowa, investor-owned, municipal, and cooperative, approach resilience planning, with a focus on flood risk. It combines hazard characterization, review of state and utility practices, and application of NLR's Energy Resilience Analysis for Distribution Systems (ERAD) and Capacity Expansion Decision Support for Distribution Networks (CADET) tools. Using FEMA floodplains, Iowa Flood Center depth grids, and utility infrastructure data, the analysis quantifies asset exposure, simulates outage risks, and evaluates resilience strategies such as pole hardening, undergrounding, and substation protection. Results indicate that while feeder-level upgrades provide incremental benefits, the most significant reductions in outage risk are achieved through targeted substation interventions. The report highlights key data gaps, such as limited elevation data and fragility functions, and underscores the need for probability-weighted investment frameworks to address both frequent and catastrophic flood events. These insights aim to support utilities, state agencies, and federal partners in prioritizing resilience investments that safeguard Iowa's electric grid against future flooding.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emerging Pathways to Upgrade the US Housing Stock: A Review of the Home Energy Upgrade Literature

The residential buildings sector is responsible for about 20% of total US energy use. In order to achieve climate goals, we need ways to reduce carbon emissions and energy use in this sector. In addition, resiliency, electric grid stability, emergency survivability and other energy and building-related issues are becoming increasingly important challenges. New homes in most of the US meet various energy codes and are reasonably energy efficient. However, the vast majority of energy use is from existing homes that were not required to conform to energy performance requirements. It is becoming imperative to reach as many of these existing homes as possible and find ways to improve their energy-related performance. This must be done in such a way that it meets the needs and desires of homeowners and building occupants, as well as those of the contractors and design professionals engaged in doing the upgrades themselves. Energy retrofits of homes started in the 1970’s in response to the energy crisis, however, these retrofits were very limited in scope and relatively few homes were upgraded. Those homes that have been upgraded generally still have much scope for improvement. A huge effort is needed to get to scale to address the energy use in housing. The target population is effectively every home in the country, whether a large suburban single-family home, or a small downtown apartment. In order to provide a framework for analysis and the basis for plans to get to large-scale retrofits of homes, this literature review summarizes the state-of-the art in the US buildings industry. It identifies where more research, engineering, or technology is needed, as well as relevant industry trends, such as electrification, one-stop shop program design and others. It also examines other key topics, such as availability of financing, minimizing household disruption, and engaging home owners and occupants. This literature review builds on a similar review from several years ago (Less and Walker, 2014). The current review focuses on efforts in the intervening years. This literature review is part of a larger DOE study of deep energy upgrades that includes industry surveys and development of cost-stack analyses. For this review, we gathered data not just from the published literature, but also from practitioners in conjunction with other aspects of the larger DOE study. In some cases, we refer to comments from specific individuals or companies, or refer to specific products by name. This is not intended as an endorsement, but rather to provide clarity on sources of information and examples of relevant technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

OpenACC acceleration of an unstructured CFD solver based on a reconstructed discontinuous Galerkin method for compressible flows

Here, an OpenACC directive-based graphics processing unit (GPU) parallel scheme is presented for solving the compressible Navier–Stokes equations on 3D hybrid unstructured grids with a third-order reconstructed discontinuous Galerkin method. The developed scheme requires the minimum code intrusion and algorithm alteration for upgrading a legacy solver with the GPU computing capability at very little extra effort in programming, which leads to a unified and portable code development strategy. A face coloring algorithm is adopted to eliminate the memory contention because of the threading of internal and boundary face integrals. A number of flow problems are presented to verify the implementation of the developed scheme. Timing measurements were obtained by running the resulting GPU code on one Nvidia Tesla K20c GPU card (Nvidia Corporation, Santa Clara, CA, USA) and compared with those obtained by running the equivalent Message Passing Interface (MPI) parallel CPU code on a compute node (consisting of two AMD Opteron 6128 eight-core CPUs (Advanced Micro Devices, Inc., Sunnyvale, CA, USA)). Speedup factors of up to 24× and 1.6× for the GPU code were achieved with respect to one and 16 CPU cores, respectively. The numerical results indicate that this OpenACC-based parallel scheme is an effective and extensible approach to port unstructured high-order CFD solvers to GPU computing.

97 MATHEMATICS AND COMPUTING↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗

Load-Shifting Strategies for Cost-Effective Emission Reductions at Wastewater Facilities

Significant hourly variation in the carbon intensity of electricity supplied to wastewater facilities introduces an opportunity to lower emissions by shifting the timing of their energy demand. This shift could be accomplished by storing wastewater, biogas from sludge digestion, or electricity from on-site biogas generation. However, the life cycle emissions and cost implications of these options are not clear. Here, we present a multiobjective optimization framework for comparing cost- and emission-minimizing load-shifting strategies at a California case study facility with a relatively low carbon intensity grid and high spread in peak and off-peak electricity prices. We evaluate cost and emission trade-offs from the optimal flexible operation of both existing infrastructure and optimally sized energy flexibility upgrades. We estimate energy-related emission reductions of up to 9.0% with flexible operation of existing infrastructure and up to 16.8% with optimally sized storage upgrades. Only a fraction of these potential savings are realized under actual industrial energy tariffs and the EPA’s recommended social cost of carbon. Energy flexibility may hold promise as a short-term emission-saving solution for the wastewater sector, but the extent of savings is heavily dependent on the cost of carbon, electricity tariffs, and emission intensity of the regional electricity grid.

climate↗